A Differential Moving Boundary Method for Transference Numbers

Publication Date: September 1943. ACS Legacy Archive. Cite this:J. Am. Chem. Soc. 65, 9, 1755-1765. Note: In lieu of an abstract, this is the article'...
0 downloads 0 Views 2MB Size
Sept., 1943

A DIFFERENTIAL MOVINGBOUNDARY METHOD FOR TRANSFERENCE NUMBERS 1755

hindrance weakens this bond and makes the compound unstable. If all four H’s are substituted by CHs, no bond can be established and the com-

[CONTRIBUTION FROM

THE

pound remains a monomeric free radical even in the solid state. NEWYORK, N. Y.

RECEIVED APRIL29, 1943

LABORATORIES OF THEROCKEFELLER INSTITUTE FOR MEDICAL RESEARCH ]

A Differential Moving Boundary Method for Transference Numbers BY L. G. LONGSWORTH

Introduction.-A boundary between two difterent concentrations, c’ and c”, of the same electrolyte, such as 0.2 N LiC1:0.5N LiC1, for example, will move, on passage of an electric current, if the corresponding cation transference numbers, T’ and T”,are different. The relation’ connecting these variables with the displacement, Av, of the boundary and the number, f, of coulombs passed is T” - T’ = Av(c” - c ’ ) f / F (1) or simply AT = A VAc if A V is the displacement per faraday, F. I n this expression c is in equivalents per milliliter if A I‘ is in milliliters. These “concentration” boundaries have been studied theoretically by Kohlrausch,2 Planck,* Miller4 and von Laue5 and experimentally by Smith.6 The latter investigation followed the boundary movement with the aid of the simple optical arrangements then in use in this field. As long as a boundary remains uniformly sharp, as do those characteristic of the direct moving boundary method, its movement may be followed accurately without difficulty. At a concentration boundary, on the other hand, the forces counteracting diffusion are relatively weak and, in general, an initially sharp boundary soon becomes indistinct due to the spreading effect of diffusion. By passing sufficiently heavy currents, Smith was able t o keep his boundaries visibly sharp during the period of observation and the displacements he observed were, in most instances, in the proper direction and of the right order of magnitude. Under the conditions of his experiments, however, errors due to convection may have been introduced. In the present investigation this diffi(1) For a derivation of this relation, together with a discussion of the various types of moving boundaries, see MacInnes, “The Principles of Electrochemistry,” Reinhold Publishing Corporation, New York, N. Y.,1939, p. 87. (2) Rohlrausch, Ann. PhysiR, 61, 209 (1897). (3) Planck, ibid., 40,561 (1890). ( 4 ) Miller, Z.ghysik. Chcm., 69, 486 (1909). (6) yon Laue, Z . anorg. Chcm., OS, 329 (1916). (6) Smith. Bur Sfandavds J Research. 6, 917 (1981)

culty has been overcome by recording photographically, with the aid of the schlieren scanning m e t h ~ d both , ~ the magnitude and the position of the refractive index gradients in the boundaries. Owing to the close proportionalitys of the refractive index to the salt concentration the electrolyte distribution may be computed readily from the refractive index gradient curve. As will be shown below, the position of a concentration boundary whose gradients may be spread over several centimeters can be defined with almost the same precision as one in which the change occurs within a small fraction of a millimeter. It is the purpose of this paper to show that this method may be used to determine, with accuracy, the change of the transference number with the concentration and that i t is of utility in cases in which the direct moving boundary method is difficult to apply.

Experimental The solutions were prepared from reagent grade chemicals and their concentrations were checked conductometrically. The quantity of electricity was computed from observations of the time and current. Readings of the latter, determined as the potential drop across a known resistance, were made a t intervals durirg the experiment with a precision of 0.1%. I n contrast with the cell containing a regular moving boundary, the resistance of the cell with concentration boundaries changes but slightly during an experiment. These changes, due to polarization of the cell and the B batteries that supply the current, are quite regular and amount to only 1 or 2%. Consequently the averaged value for the current has essentially the same precision as the individual observations and the use of a constant current device is unnecessary. With the differential method described here the concentrations and electrical quantities do not need to be known as precisely as in the case of the direct moving boundary method and the procedure just outlined is adequate for the determination of transference number differences with a precision of *l X 10-4. The cell in which the boundaries are formed and nbservprl (7) Longsworth, Tms JOURNAL, 131,529 (1939). (8) Lamm, Nooo Acta Regiae Soc. Sci Ugsalicnsas. Ser. IV. 10, No. 6 (see p. 64) (1937)

L. G. LONGSWORTH is shown in Fig. 1 and, except for the top section A, will be recognized as the Tiselius cell9 for studying the electrophoresis of proteins. Since many of the boundary displacenients observed in the course of this work have been small, it has been necessary to elimiA nate the relatively minute volume changes in the closed side of the apparatus that result from an expansion, or contraction, of the \ rubber connections characteristic of the usual Tiselius a E assembly. This was accomplished by redesigning the top section to include the electrode cups as shown a t A in Fig. 1. For the same reason i t has been found necessary to use a 3b b E minimum of lubricant in I , Fig. 1.-The moving bound- assembling the cell. Otherwise the light pressure mainary cell. tained on the assembled cell and stopper slowly forces the excess lubricant out and causes disturbing volume changes. The cell is fdled and the boundaries are formed as in work with proteins.1° The bottom section, C, and the right-hand channel of the center section, B,are filled with the concentrated solution, the remainder of the cell being filled with the dilute solution. In practice the right-hand electrode vessel is closed, care being taken to avoid trapped air bubbles, by means of the ground-glass stopper, S. The silvex-silver chloride electrodes used in most of the experiments are of the same design as those previously described,ll although smaller in size. They have a capacity of 0.0075 faraday, i. e., 0.2 ampere-hour, and in order t o utilize this capacity it is necessary to immerse the electrodes in a rather concentrated chloride solution. Five ml. of a 1 N solution is sufficient in most cases and are introduced through the silver tubes, t and t’ of Fig. 1, that also serve to make electrical connection with the electrodes. A 1 N solution does not dissolve appreciable amounts of silver chloride. The boundaries are formed simultaneously a t a-a’ in the right-hand channel and a t b-b’ in the left-hand side. After forming, the boundaries are brought out from behind the opaque horizontal plates of the cell for a distance of about 2 cm. by slow injection of solutioii from the syringe, d. The piston of the latter is displaced at the desired rate with the aid of a small synchronous motor. The contents of thesyringe are then isolated by turning the stopcock, n1, to the position shown in Fig. 1, after which the poteutial is applied. For the first five or six minutes after icpplicaiiou of t,lie

- -____

‘9) Tiselius, Trans. Paraday S O L SB, , 624 (19371. 1 1 0 ) Longsworth, Chcni. Rev.. 80, 323 (1942). 1 1 ) Longsworth and Mnclnnes. { b i d , 24, 471 f I W ! i i

Vol. 65

potential the current through the cell increases as the steady state distribution of temperature is established and then changes but slowly, as previously noted. Small volume changes appear to accompany the attainment of the steady state. Consequently the first scanning photograph of the boundaries is not made until the current has been flowing for five or six minutes. All subsequent photographs are a150 made with the current passing. The movement of the boundary during the scanning interval of one to three minutes is small and introduces a negligible error if the time of the recording is taken as that at which the scanning is half completed. The author has adopted the practice of photographing the boundaries after electrolysis for about two hours and again after four hours. The current is then reversed and a fourth photograph taken after the boundaries have moved in the opposite direction for another interval of two hours. I n this manner three values for the velocity of the boundary in each side of the channel are obtained or a total of six values. The constancy of these values affords a check on the experiment that will be discussed later in this paper.

Recording and Locating the Boundary.-The schlieren scanning camera used in this research is the same as that for the electrophoresis of proteins and has been described elsewhere.I2 Exposures were made on Eastrnan CTC panchromatic plates with the light from an H4 mercury lamp and a Wratten E filter. Prints of typical boundary patterns, obtained with the aid of this camera during the electrolysis of 0.1 N : 0 . 2 N solutions of calcium chloride, are shown in Fig. 2 . I a The edge between the light and dark areas of such a pattern is a plot of the refractive index gradient in a thin layer of solution in the cell as ordinate against the height of the layer as abscissa. The edge of the pattern represents the shadow cast by the schlieren diaphragm. Since the latter is not focussed on the photographic plate, a diffraction pattern appears in the illuminated area at the edge. This is illustrated in Fig. 3, which is a microphotometer tracing, obtained through the courtesy of Dr. E. G. Pickels, from the area enclosed by the circle in Fig. 2. Whereas ho of Fig. 3 represents the position of the geometrical edge of the shadow,I4 and hence the height in the cell at which the gradient has the value given by the ordinate of ho, it has beeii found experimentally that the position h of the first diffraction minimum can be located with greater precision than h+. With the method for locating diffuse boundaries given below the errors b u s JOURNAL, 63, 705 (1940) (13) The vertical and horizontal striae in the patterns of Fig. 2 are due to traces of dirt, or scratches, on the cell windows and to imper ( 1 2) Longsworth and MacInneu,

fections in the plate movement, respestively. (14) Wood, “Physical Optics.” The Macmillan CL, rz ’r’, 1 ~ 2 4p, 192

New Yurk

n

Fig. 2 . - ~ l ? I i c r w scanning patterns of the boundaries between 11.1 arid 0.2 N solutions of calcium chloride.

introduced by usiiig h instead of ho are largely cancelled.

n Pig. 4.

I

h Fig. 3.

IL

h"

Microphotometer tracing of the edge of pattern.

B schlieren

The maximum gradient of a boundary which remains uniformly sharp during its motion may, without error, be taken as the correct location of the boundary. If, however, the relative distribution of the gradients is changing, the boundary position requires careful definition. This may be illustrated with the aid of Fix. 4. Tn this figure the gradient curve, Fig. -la, for a typical boundary

has been integrated to give the corresponding integral curve, Fig. 4b, of the refractive index wersus the height in the cell. The axis of ordinates for the integral curve has been taken as the refractive index, n', in the body of the dilute solution. The refractive index, n",in the body of the concentrated solution is then n." - n' or An. If an initially sharp boundary between the two solutions started at h = 0, for example, and acquired the distribution shown in Fig. 4b on passage of the current, the net quantity of salt transported by the latter would be proportional to the area, ndh, under the integral curve. Moreover, if

Jrn

the transport had been effected without sacrificing the sharpness of the original boundary the latter would be at the position, E, given by the relation hAn =

fndk

(2)

With this definition of the shaded areas of Fig. 4b cancel each other. It may be noted that there is no net transport of material by diffusion alone.

L. G. LONGSWORTH

17.58

1t is, however, unnecessary to construct the integral curve in order to locate h. The righthand term of equation {2) may be integrated by

I'arts to give h h

= --

(I" hdn -I-ah]:

.

Since

/I

and n vanish at 0 and a, respectively, the last term is zero and this equation may be written h An =

-

tntal area,

1171

is given by the

(d?r/dh)di?, under

the gradient

h(dn/dh)dh.

-La

Since

('Iirve. Pig. -La, the expression for

becomes

'I'he correct boundary position is thus the position of the first moment or centroidal ordinate of the gradient curve and several methods for its evaluation are available.15 The one adopted was its follows. The photographic plate is placed in a two coijrdinate coniparator16 with the base line of the pattern parallel to one of the axes. The ordinates of a number oi chords, say five, are located, 011 one scale of the comparator, a t equal iiitervals between the base line and the niaxiniuni, as shown in Fig. 4a. 0 1 1 the other scale the abscissas, h/ aiid Ill", oi' the ends of each chord, together with the correspoiiciing abscissa, hie, of the edge of the pattern, are then determined. The abscissa, h i , oi the midpoint of a chord is thus ('1~: It:),?. If the distances hi - h i , are the same for each chord the gradients in the boundary are syninietrical about the ordinate through the maximum and h -- he is the position of the boundary referred to a fixed point on the cell since the vertical edge of the pattern corresponds to one em1 of the chaiinel. If the distances to the centers of the c1ic)rds are riot equal, the boundary is "skew." If this skewness is not too great, the following relation, which is equivalent to equation {3), may he used: A =: &Ahi (& -- hie)/XiAhi. In this expression Ah, is the length, h:' h;, of the i-th chord. In cstreine cases, such as the rising boundary of Fig. 9, more tedious inethods must, however, be employed. With such a boundary a large Iiurn-

+

(16) Running, "8rnpiricai Forniulat," Johii \Vile> aud Soli\, h r . , New 'iork. N. Y.,1917, p. Ilk (16) The cumparatur .;cdea, :it right iiiiglcs t u eacii other, re graduated i l l millimetw. i i i i d provided with 1 0 ( l i k i 4 o I i vernier5 Readings are interpolated t o the nearest 0.02 mm The comparator microscope gives a magnification o f 1 2 X . The eyepiece contains a ,tale whose central line is used as the reference mark. The author takes this opportunity of expressing his appreciation t u Mr. J u s d Mum of The Korkefellrl Imstitule instriiment shop for t h e P R T C atld ,,*ion uith uhtrh i h : , ci,ini,:~rntor IW. I I I : + C I ~

Vol. 65

ber of chords, or ordinates, must be ineiisured and it is not permissible to use the first diffractioii minimum mentioned above since the slight errors iiivolved do not quite cancel. The base line of a pattern is the lower edge that the pattern would have if no boundaries were present in the cell when the scanning photograph was made. The base lines of the patterns recorded in the course of this work are straight but in some instances deviate slightly from the vertical in the focus of the camera If the plate is improperly oriented in the comparator this type 01 distortion may introduce errors into the locatioii 01 the midpoints of the chords. These errors are eliminated by placing the pattern in the conipirator with the base line parallel to one of the J Y ~ Sof the latter. The edge of the pattern then iii,ibcs a small angle, F3 of Fig. 4, with the other comparator axis and the measured boundary displacements should be multiplied by cosine 8. +illowatice should also be inade for the enlargeineiit factor for the camera if this is not unity. Results. -The experimental results are given 111 Table I. The salt is listed in the first columii of this table and the concentrations, in equivaleiits per niilliliter, of the two solutions forming the bouiidaries are given iii the next two columns. I'he current passed through the cell is recorded in the fourth column. The boundary displacement per faraday, given in column 3 IS thc mean of the six values obtained as described above. Allsoincluded in this column is the aver,tge deviation from the mean. If the boundary mo\ es with the current the displacement, A JTk>, I > positive The correction, A 16, for the volume clianges due to the electrode processes is recorded in column 6 and will be discussed later in this paper. The transference number increment, i. e . . 1'I = ( A Vb - AVe) Ac, is recorded in column 7 , m i , for comparison, the last two columns 01 'Table I contain values of A T computed from existiiig traiisfereiice data obtained by the direct moving boundary and Hittorf methods, respecti vel!, Discussion If the average deviation of the individual x dhes of A I ' from the niean niay be taken as measure of the precisiori of the differential method, it is of the order of 1 or 2 units in the fourth decirial place. This compares favorably with the precision of the direct moving boundary method. I n this study oi thc differential method a thermo-

TABLE I TRANSFERENCE NUMBER DIFFERENCESFOR AQUEOUSSOLUTIONS O F SOME SALTS 2

1 Salt

KC1 KC1 NaCl NaCl NaCl LiCl KBr KBr CaCl2 BaCl? CdIz CdIz CdIz LaCh Lac13 Lac13 LaCla LaCls LaCla LaCla

C"

1759

A DIFFERENTIAL MOVING BOUNDARY METHOD FOR TRANSFERENCE N UMBERS

Sept., 1943

x

3 io4

0.500 ,500 ,200 ,500 ,500 .!5025 .200 ,500 ,201 ,200 ,100 ,200 ,300

.loo ,200 ,200 ,200 .400 .604 ,805

c'

x

108

0.200 ,200 ,100 ,100 .200 .200 .050 .200 ,1005 ,100 .050 ,100 .200 ,050 ,050

.loo ,400 ,600 .805 1.006

4

5

6

Ma.

AVb, ml.

A V e , ml.

1.2*0.3 10.1*0.5 27.5*1.1 - 14.9*0.4 11.610.4 - 28.211.1 - 0.3*1.3 2.0.tO.6 - 97.6*1.8 - 87.011.0 -1998 1 9 -1282 *6 - 731 *1.7 - 209.0*1.8 - 159.712.3 - 139.6.tl.2 85.2*0.9 - 57.3*0.8 - 43.5.tl.O - 34.311.1

1.3 -7.4 9.2 9.3 9.3 9.7 2.4 2.4 11.3 9.9 20 0 27.1 12.5 11.6 11.6 11.8 11.9 12.1 12.2

36 32 25 25 35 32 13 36 37 33 7 12 12 16 12 30 37 41 42 35

-

-

+

-

stat temperature of 0.5' was selected in order to reduce the disturbing effects of heat convection. At a temperature of, say 25', i t would doubtless be necessary to use smaller currents than a t the lower temperature. The spread of a boundary due to diffusion would thus be greater for a given displacement and the precision of the method might be decreased somewhat as a result. A single experiment a t 25' with 0.1 N:0.2 N solutions of lanthanum chloride gave AT = -152 * 2.2 X and it will be noted that the average deviation is greater than that, 1.2 X for the same experiment a t 0.5". In addition to the constancy of the boundary velocity as a check on the experiment, the transference number differences should also be additive, i. e., the sum of the differences for two consecutive concentration intervals should be the same as the difference for the total interval. Sufficient data are given in Table I to permit two tests of this principle. For 0.1 N:0.2 N and 0.2 .V: 0.5 N solutions of sodium chloride the values of AT are -0.0037 and -0.0063, respectively, and the sum, -0.0100, may be compared with the value, -0.0097, for the 0.1 N : 0 . 5 N solutions. Similarly, the sum of the values of AT for 0.05 N : 0.1 N and 0.1 N : 0 . 2 N solutions of lanthanum chloride is -0.0262 whereas that for the 0.05 N :0.2 N solutions is - 0.0257. The deviation from additivity in these two examples indicates a somewhat larger experimental error than does the con-

7

AT

-

x

-

0.5' 9

8 104

7.t0.9

8*1.5

37*1.1 97*1.6 63.t1.2 11513.3 412.0 111.8 - 109*1.8 - 97.t1.0 -100915 -128216 - 75811.7 11110.9 - 257*3.5 - 151*1.2 - 19411.8 138*1.6 112*2.0 - 93*2.2

-

AT

AT^^^

x

104

AT&

IX

- 6 - 6 - 33

-117

+ 10 -

- 119

107

- 91

- 107 -249 142 - 198

-

- 130 -296 - 165 -206 - 142 -112 - 96

stancy of the boundary velocity. It may be noted however, that in both cases the average deviation of AT from the mean, as given in Table I, is greatest for the wide concentration interval. Possibly because of the great disparity between the amounts of heat generated in two solutions whose concentrations differ widely, it does not appear desirable to have too great a difference of concentration a t the boundary. The recent precise measurements of Allgood and Gordon" for sodium chloride indicate that transference number differences are not very sensitive to the temperature although their absolute values may change appreciably with that variable. Consequently the comparison between values of AT valid for 0.5', column 7 of Table I, and those valid a t 25', columns 8 and 9, is justified. The values of column 8 are from the author's earlier and those of column 9 are due to Jones and his associates.20~21~22 The Hittorf values for lanthanum chloride were computed from the equation of Jones and Prendergast.22 In general the differential method yields values in good agreement with those obtained by the direct moving boundary or Hittorf methods. The apparent exception in the case of solutions of potassium bromide may be due to the fact that the mini(17) Allgood and Gordon, J . Chcm. P h y s . , 10, 124 (1942). JOURNAL, 51, 1185 (1935). (18) Longsworth, THIS (19) Longsworth and MacInnes, ibid., 60, 3070 (1938). (20) Jones and Bradshaw, ibid., 64, 138 (1932). (21) Jones and Dole, ibid.. 61, 1073 (1929). f22) Jones and Prendergast, t6id , 58, 147fj (1!13(;).

1 7tio 0.46

Vol. ($5

I

I

I

-1

In this respect the differential method is supplementary to the direct method s i i i c e the application of the latter to concentrated solutions has met with tlifliculties A study of concentrated solutions with the aid of the differential method is illustrated by the data of Table I for lanthanum chloI-idc. If the transference numbers of a 0.1 1%' solution of this salt is assumed to have the same value, 0.4375. a t 0.5 as a t 2 5 O , the differential method yields the values indicated by the circles i i i Fig 3. These values fall on a smooth curve that also includes the directly measured transfertwce numbers, the latter being indicated by the dots. The crosses of Fig. 5 are the Hittorf values of Jorics arid Prendergast. Although they differ , I I ! I somewhat i i i inagnitutle from the moving bounI j i dary results, they yield essentially the same slope 0.36 I as the i n o v i n g boundary methods above a con0.2 0.4 0.6 0.8 I I1 centration of about 0.1 dconcentration. Owiiig to the tlifticulty of finding sufficiently Fig. 5.--Transference numbers of lanthanum chloritic as a function of the square root of the concentration: slow indicator ions it is doubtful if the direct rnovt- , Jones and Prendergast; 0 , direct moving boundary ing boundary method could be applied to solumethod; 0, differential moving boundary method. tions of cadmium iodide. Concentration bouridaries, on the other hand, yield quite satisfactory mum in the T vs. c curve for this salt occurs a t a hloreover, the rapid change of the trati5resultc. higher concentration at 0 than a t 25'. f'ereiice iiurnber with the concentration of this Although difficulties have been encountered i i i material gives rise t o a phenomenon a t one of the the application of the differential method at coliboundaries, namely, the movement of the bouricentrations of 0.02 N and below,23the upper limit tlary ;iq a steady state, that will be discussed later 129) The following results for 0.2 N : 0 . 1 iv solutions of lithium

I

I

Ii

ot cnnceiitration hds not yet been found.

Y

~

chloride a t 0.021 amp. are typiml of those obtained with dtliite sohi,iri:l tions. The successive values of AVb were - 2 3 8 4 , -'A!> - 5 4 t for the boundary in one side of the channel and - - < ! O t . 94 and - 1 7 2 4 for that in the other side, the current habini: been reversed after the second interval. The arrows indicate thc direction in which t h e boundary moved. The mean of these figure, I S -- 142, with an average deviation of 63, whereas the correct \ - ~ i I i i e ii,ongsworth, THIS JOURNAL, 64, 2741 (1932)) is about - lr!7 ml p w faraday. These deviations from normal behavior, which are dur t o convection, may be explained as follows. Convective circulation is due both t o the heating effect o f the ciirrent and electro-osmosis. Since streaming due t o electro-osmosis de pends upon the direction of the current, while that due t o heat doc., not, the two effects enhance each other in one side of the channel and tend t o cancel in the other side. Owing t o the vertical density gradi. ent a boundary is able t o restrict the circulation t o the hornogeneouh ~.olutionsabove and nelow but In so doing tends t o br "eroded" b! the circulation. I n the case of concentration boundaries convection is most pronounced in t h e poorly conducting dilute solution above the boundary. The topmost layers of t h e latter are, therefore, the fir.1 t o be disturbed and the more concentrated solution in these layers ih carried npward and mixed with the homogeneous solution abovr. As already noted experimentally, the boundary in one side of the channel thus descetlds too rapidly while t h a t in the other side rises too slowly. Moreoyer, the resulting errors do not cancel because of the inequality of the convection in the dilute solution in the two sideq of the channel. Experiments with 0.02 N : 0.1 N solutions of lithium chloride a t other currents, and also in a narrow channel of 1.5 X 2 5 mm. cross section, indicate t h a t the contribution of electro-osmosis to the convection is a n important one in dilute solutions. The downward displacement of a concentration bounddry due to FvJsion of its upper layers by convection may even exceed t h a t dur t u I n this e! e n t a boundarq descends reKardlci., ui t h e di! h e ciirrent

4

t

ll

0. 1

0.2

o.:i

0.4

Concentration. Fig. G--'l'ransference numbers of cadmium iodide as a function of the concentration: 0, Redlich; X , Noyes and Falk's iiiterpolation of Redlich's data; 0 , differential moving boundary method. .- .

rsction of the current. This phenomenon has been observed with The solutions of potasqium chloride hy both Smith and myself disturbance of the boundaries by convection i.s also evident trom the appearence of t h e schlieren bands 'The edges of the latter are no1 horizontal for those portion. o t tlic boiindary into which the circulalion pcnctrates.

Sept ., 19-13

A DIFFERENTIALMOVINGBOUNDARY METHODFOR TRANSFERENCE NUMBERS 1761

in this report. The data of Table I for cadmium iodide are indicated by the dots in Fig. 6, 0.3040 having been taken as the transference number of a 0.1 N solution of this salt. The curve of the figure was drawn through these points and extrapolates smoothly t o Redlich’s value a t 0.5 N . The value 0.3040 was selected on the basis of Redlich’sZ4data a t 18’. The latter are indicated by the circles in Fig. 6. Although most of Redlich’s values are reasonably consistent with the concentration boundary results, i t is difficult to draw a smooth curve through the data that includes his value a t 0.25 N . The crosses of Fig. 6 are the values interpolated by Koyes and Falk26 from the data of Redlich and reproduced in the “International Critical Tables.” Noyes and Falk apparently gave considerable weight to Redlich’s value a t 0.25 N which now appears to be in error. The Volume Correction.-As in the direct method, the boundary displacement, Avb, is observed with respect to the cell. The displacement required, however, is that with respect to the solvent. Due t o the volume changes a t the electrodes the solvent itself undergoes a displacement, Ave-taken as positive if the solvent moves with the current-and this must be subtracted from Avb to give Av of equation (1). If one electrode chamber is closed only the volume changes in this side of the cell need to be considered. For a silver-silver halide cathode in a halide solution of a z-valent cation, X, the changes, per faraday, are ab’, = V A ~ Y V..ig - T ’ ’ ~ X Y ~ / Z

VAg and, , , iT are the atomic and molecular volumes of silver and silver halide, respectively. T” is the cation transference number of the more concentrated of the two solutions forming the boundaries. The partial molal volume of the salt, I/xys, corresponds to the concentration of this solution around the electrode. As previously notedzCthis concentratiorl changes during electrolysis and there is some uncertainty as to the precise value to be used. In the present investigation this uncertainty is slight since V changes relatively slowly with concentration in the strong solutions bathing the electrodes. The relations of Table 11, determined from the best available density data a t O o , were used (24) Redlich, Z. physik Chem , 37, 700 (lYU1) ( 1 5 ) Noyes and Falk, THISJOURNAL, 33, 1436 (1911) 126) I ongsworth i b i d , 64, 2741 11932)

in computing the values of AV, recorded in column 6 of Table 1. TABLE I1 PARTIAL MOLAL VOLUMES, AT

o“,

OF SOME SALTS I N

AQUEOUSSOLUTION KCl 7 = 23.66 3.75 fi (1) NaCl LiCl KBr CaC12 BaC12 CdIz Lacla

+ + 3.24 4% (1) + 2.85 4% (3.2) = 30.22 + 3.42 4% (1) = 13.42 + 10.77 4% (2.5) = 19.85 + 9.78 fi (1.2) = 13.35 = 15.40

= 46.40 = 8.87

+ 37.20 4 Z + 22.65