A simple electronic interface for wireless chemical data communications

Apr 1, 1988 - Bits and pieces, 37. A brief note on a simple electronic interface for wireless chemical data communications...
0 downloads 0 Views 2MB Size
of oreanic solvents. dissociation constants of acids, indicator pH ;nges, transport number of H+, molar ionic conductivities. standard half cell potentials, solubilities, and activity coefficients. The database is menu driven, each new additional table heing added to the contents display and becoming accessible to all future users of the database. The students are marked on accuracy of the tabulated data, whle layout, inclusion of correct units, mention of any relevant conditions, and reference to the source of the data. Thus not only does the exercise provide an opportunity to apply programming skills but it also serves as an introduction to computerized databases; i t combines library work with experience in selecting appropriate data and accurately reporting all relevant conditions applying to the data, and also it acts as a prompt to encourage making reference to literature values in their laboratory reports. The author will be pleased to supply further details on request.

A Microcomputer-Based Temperature Probe Chla-yu Lil and Oun-meng Zhuang East Carolina University Greenville, NC 27834 A circuit interfacing a temperature probe with an APPLE IIe comauter has been develoaed. The maior com~onents used in {he circuit consist of adheatstone bridge, twb operational amalifiers. an eiebt-bit intenratinn analoeue-to-dipitalconveier, anda pro&ammable 6520~&iphe&Ilnterf&e Adapter. A silicon transistor whose metal casing is used as the temperature sensing probe forms one arm of the Wheatstone bridge. The impedance between the collector and emitter of the transistor varies as temperature changes, thus creating an imbalance of the bridge. The hridge output is amplified by the op amps and digitized by the ADC before it is sent to the computer's peripheral I/O slot. The temperature response between 0 and 100 OC is extremely linear (correlation coefficient = 0.99994) with a resolution of 0.39 "Clstea. Better resolution can be achieved if calibrated with a narrdwer temperature range. The device has been successfullv used for the determination of the specific beats of metals. The same circuit can also be used as a digital data acquisition device for low-frequency analogue signals (maximum sampling rate 2 mshyte). Short machine language programs, whichare callable by BASIC,are required to drive the interface circuit. Full details are available from Project SERAPHIM.

Microcomputer-Controlled Automated Sampler Shahrokh Ghaftari Mount Mary College Yankton, SD 57078 As a Dart of a microcom~uter-AFinterfacinn proiect, an automa'ted sampler for t h e nebulizer of an atomic fluorescence s~ectrometerwas desinned. This sampler is designed fur a two-solution system (hiank/sarnple) and is ideal when alternate blank/sample measurements are desired. The introduction of each solution into the flame is controlled by the software. The system is simple and easy to build and has applirations in other interfacing projects such as an auto-buret for titration or for introductionof reactants into a cell for a reaction study. The three parts, A, B, and C (Fig. 2) are installed inside a 5" X 8" X 4" aluminum box; no other parts except tubing are required. Auihor to whom correspondence should be addressed. 344

Journal of Chemical Education

Flgure 2. Schematic of components for automated sampler. A. SPST microcube solidstaterelay switch: Grayhill, Inc.. 561-T Hill Grove Ave.. Box 10373, La Grange, IL 60525. 8. Three-way solenoid valve: Serlal number H02-726 Skinner Precision Ind.. Inc.. 95 Edgewwd Ave., New Britain, CT 06050. C. Three-way slide valve: Dianex Co., P. 0.Box 3603, Sunnyvale,CA 94088.

Figure 2 shows a single-pole single-throw relay switch is used to turn on and off the ac power to the three-way solenoid valve. The solid-state relay is controlled by one 1iO line, which goes through a TRI-STATE buffer (not shown) before going to the contiol input of the relay. A logic 1signal on the I10 line switches on the relay and hence the solenoid valve that directs air (-40 PSI) to a three-way slide valve. The slide valve moves, and this causes the output of the slide valve to be connected to innut 1 (blank). The output of the valve is connected to the b k e r nebul'er with 0:5 mm i d . tubinn. When a loaic 0 sianal is connected to the control input; the output of the solenoid valve is connected to the atmosphere and the output of the slide valve is connected to position 2 (sample) through action of a spring.

A Simple Electronic Interface for Wlreless Chemical Data Communications Lee Hln-Fat, Hln-Cheung Lee, Kuen-Cheong Au-Yeung, and Hon-Tsang Chan Hong Kong Baptist College 224 Waterloo Road. Kowloon, Hong Kong Many undergraduate students may be interested in learnine the orinciales and the aoolications of electronic interfaces in wireless chemical data communication. A preliminary project that attempts to satisfy this interest has been carried out by our students. Data obtained from an iodine clock reaction were transmitted in the form of electromannetic waves to an Apple I1 microcomputer that had been connected to a wave receiver through an interface. The computer then calculated the order of the reaction. In order to make the svstem as inexpensive as possible, a minimum number of materials were &ed. The items involved included a phototransistor, a radio transmitter, and servo, all of which can be readily purchased from model or hobby shops. The output of the phototransistor was connected to a commercially purchased radio transmitter (Fig 3). The trimmer was set such that the output of the phototransistor under maximum ore-set lieht intensitv was eaual to that of " the maximum transmitter trimmer soltage. As a result, the trimmer of the ~hototransistortook over the function of the transmitter trimmer in the radio control. We used the signal intended to drive the motor in the servo as the inputio the receiver interface. The range of the input was e4V. The IC74CS14 interface used for this work was connected to one channel of the receiver as shown in Figure 4; neither amplification nor attenuation of the signal was necessary. In combination with the laboratory location where the preliminary transmission work was done, our system proved virtually impervious to interference that could

-

..

+ 5 volts I

Figure 4. Schematicdiagram of receiver and computw imerface.

Figure 3. Schematic diagram of delenor and Iransminer have led to the unreliahility of data transmission. It should also he noced that theschmitt trinner naveeitherarerostate or one state, dependingupon whetherthe input was larger or smaller than a threshold voltage. Therefore, for a quantitative measurement of an analog input signal, an AD converter card is needed.

The Group-ot-Three Phenomenon: Does It Work With Computers? Gem Rayner-Canham

Sir Wilfred Grenfeli College Corner Brook. NF, A2H 6P9, Canada During the use of our computer-assisted drill program (14). we received requests from students to be permitted to work in pairs. This h a s to allow them to discuss problemsolving methods with each other. We noted that a three-way interaction seemed to develop hetween the two students and the computer. A similar observation of group work has been made concerning a drill program in biology (15). This threeway interaction brought to mind some previous work that showed students work best in groups of three (16). It is possible that the same principle is working in our case, but with the computer being the third component.

The concept of students working individually a t terminals seems to be generally accepted. Perhaps this is due to the "loner3'-type personalities of earlier computer enthusiasts. The student-nair method warrants further investieation. Not only did seem to promote learning, but it also seemed to overcome the reticence of comauter-nhobic students. who no longer had to face the machine alone.4

ii

Literature Clted 1. Mmre,J. W.;Brwks.D.W.:Fuller.R.G.:Jensen,D.D. J. Chem.Educ. 1977,54,276. 2. Johnson,K. J;Vm Willia, W.;Seely,O., Jr.; Moore, J. W.J. Chem.Edue.1981.58.177. 3. Aikens.D.A.:Baiiey,R.A.:Giaehino,0.0.:Moore, J.A.:Tomkins,K.P.T.Inregrorod Ezperimenfm Chamisfry: Allyn & Bseon: Boston. 1976;Vol. 2. Chapter 52.

4. Shoemaker, D.; Gsr1and.C. W.; Steinfe1d.J. I.; Nibler, J. W. Experiments inPhysied Chemistry, 4th ed.: MeGrsw-Hill: Near York, 1961: Chapter 8. 5. nanieb,~.: w i ~ l i ~~ .~ ;~B, ~~ ~. ~ ~ ~ , P . ; A I ~ ~ ~ ~ ~ , RJ.E. .A.:c~~~~~I ExpmimentdPhy8tcal Chemistry. 7thed.:McGrav-Hill: Near York, 1970: Chapter 6. 6. Ref. 3, Chapter 22. 7. Ref. 4. Chanter 7. 6. Ref.5;chapter 4. 9. Ref. 3, Chapter 26. 10. Herbrsndaan. K. F. J. Chem. Edue. 1971,48,706. 11. Ref. 3,Chapter35. 12. Young,J. A,; Zefo,R.J. J. Cham.Educ. 1958.35.146. 13. Lehmao, J. R. J. Chsm. Educ. l985.62(6), 49fA99. 14. bynor-Csnhsm, G. W.: Dickie, W.J. Computers Moth 15. Capri0.M. W.J. Co1l.S~;. Teach. 1985.15.87. 16. Taylor, T. E.J. Coll. Sei. Teach. 1976.5, 320.

A s pointedout by areviewer,there will still be those who preferto work one-on-one with the computer. In fact, it would be interesting to correlate personality type and academic ability with preference for single or pair working.

Expanded MlCROgram Newsletter Now Available The EPIE Institute has announced thst they have expanded their existing newsletter, MICROgram, to indude monthly information on up to 175newly cataloged programs that they have added to the EPIE data base in previous weeks. This change was necessitated hy the rapid growth in computer programs thst originally were described on an annual basis in the EPIE publication TESS(The Educational Software Selector). The MICROgram software descriptions include suhjeet area, program type, grade level, computer compatibility, price, summary of operation, and ordering information, In addition, the expanded MICROgrom continues to report on current topics and issues in computer-oriented education and offers subscribers the opportunity to order EPIE PROIFILE's, comprehensive individual evaluations of selected courseware. Also, the new MICROgrarn contains a listing of citations to software reviews by other reviewing agencies newly added to EPIE's database and the option for subscribers to send for the full text of reviews. Subscriptions to MICROgram are $55 or $50 if purchased with the four-volume 1988-1989 edition of TESS-The Educational Software Selector. TESS is EPIE's comprehensive guide to educational software programs and publishers. For further information or to place an order, write EPIE Institute, P.O. Box 839, Water Mill, NY 11976. Or call (516) 2834922.

Volume 65

Number 4

April 1988

345