ducing water comparable to triple dis tilled and the other for water compar able to single distilled. No electrical controls are required. The mixed resins used change color as the exchange capacity of the unit be comes exhausted. Units can be easily replaced and can be mounted on labora tory stands or in a permanent bracket.
ACE
ACE Sintered Glass Filters
N e w Increased HARDNESS Gives L-o-n-g-e-r
Life
No Contamination due to detachment of Filter Particles
15 Laboratory Washer
Fisher Scientific Co.'s improved Charlab Washer handles a wide variety of glassware ranging from micropipets to odd-shaped apparatus and large-size graduates. Large pieces are locked directly in place by a combination of rods and screens and smaller units can be placed in accessory baskets. Revolving disks dip the glassware into hot wash water, soak it, then empty it as they rotate at 8 to 9 r.p.m. Both steam- and electrically heated models are available. 16
8610 6130
Homogenizer
A portable, high pressure homoge nizer has been developed by C. W. Logeman Co. for labora tory processing of ma terials in a closed system. The appa ratus handles quanti ties from 1 ml. to 25 gallons per hour at pressures to 3000 pounds per square inch. Stainless steel is used for all metal parts coming into contact with the product, which is completely separated from the drive mechanism. No packing or stuffing boxes are required, nor water or waste connections. The homogenizer head can be completely removed for autoclaving. The complete unit includes pressure gage, reservoir, plastic tubing, and 3 A-hp. a.c. motor. 17
, , 8562
STANDARD UNIFORMITY Each Filter Plate Is Individually Tested For Porosity and Hardness
8575
Filter Discs POROSITY CHART Porosity
Max. Pore Oia
Description
(Microns)
A
145-175
Β
70-100
C
25-
50
D
10-
20
Ε
4-
8
In trie following Miffirneter Sizes 10-25-30-40-50-65-90-120-150
Diffusion Pump Oil
Purified, - distilled-in-glass di(2-ethylhexyl) phthalate is being sold by Cen tral Scientific Co. for use as diffusion pump oil. According to Cenco, it can be used in a single-stage, nonfractionating pump in producing a vacuum of the order of 7 X 10 ~e mm. of mercury at 25° C. without use of a liquid air or charcoal trap. Cencoil Β is stable under normal con ditions and permits operation at rela-
Available
ACE GLASS VINELAND
For further information, see coupon on page 43 A V O L U M E 2 6, NO. 3, M A R C H
iront
Stock
Send for Complete Brochure Listing the ACE Line of Sintered Glass Filters and other filter media DEP'T SF- Ε
1954
INCORPORATED NEW JERSEY 47 A