ALBERENE STONE

difference to range in any given case yielded a value which could be ex ceeded by chance alone less than 10% of the time, the observation was desig na...
0 downloads 0 Views 313KB Size
difference to range in any given case yielded a value which could be ex­ ceeded by chance alone less than 10% of the time, the observation was desig­ nated as inconsistent with the rest and therefore not used for evaluation of the performance of the analyst for the par­ ticular method. Each individual tested received at least three different concentration levels on the nine test samples for each method. All test samples were supplied by the Standards Laboratory which is in a Group of the Analytical Section, su­ pervised independently from the Shift Control Laboratory. Where experi­ enced personnel were tested, these sam­ ples were used for the current quality control program. Single determinations for each sample were made and reported; however, enough sample was supplied for duplicates, in case a spill or loss of sample during pipetting made it neces­ sary to repeat the analysis. Table I is a list of methods (7) in­ cluded in the program. All methods used in the laboratory were not included in this program since techniques used in some methods are the same as those used in others. Be­ cause of the unstable nature, it was im­ possible to prepare testing samples ac­ curately for several methods; therefore, they were not included in this program. Statistical Analysis Results. Ex­ perienced employees were tested on methods which they were routinely using. New employees are trained, using a known standard. The stand­ ard is processed nine different times. Answers from these standards are evalu­ ated statistically and satisfactory results must be obtained before a new employee is allowed to analyze unknown test samples. As complete sets of data on a method were obtained for an individual, they were statistically analyzed. The following information was reported to laboratory supervision as a result of the statistical analysis on each set of data submitted by an analyst.

Table I.

1. 2. 3. 4. 5. 6.

Methods Included in Training and Testing Program

Colorimetric determination of uranium Fluorophotometric determina­ tion of uranium Isotopic dilution determination of uranium Titrimetric determination of Hg(II) Titrimetric determination of aluminum Potentiometric determination of free acid

INCREASED PRODUCTION THE GEORGIA MARBLE COM­ PANY— the most efficient stone and marble producer in the U.S. A.—is now in full charge of p r o d u c t i o n in the ALBERENE STONE quarries and mills at Schuyler, Va. Greatly stepped-up output now permits us to say, "Let's talk immediate deliveries!"

Immediate Deliveries! Alberene Stone can be shipped normally in 60 days—or even sooner to meet very special circumstances. W e can schedule our deliveries to meet all reasonable requirements of contractors a n d laboratory equipment manufacturers. Further, the supply of Alberene Stone is inexhaustible. New veins are constantly being located in company owned quarries in Albemarle and Nelson Counties, Va. Alberene Stone is the only natural silicate stone with the surface that goes all the way thru. It can be cut, drilled, tongueand-grooved, refinished and reused almost indefinitely — while providing the best obtainable chemical resistance ! For information and technical assistance, address: Alberene Stone Corporation, 419 Fourth Avenue, New York 16, Ν . Υ.

ALBERENE provides

LOW ABSORBENCY

protection

For further information, circle number 21 A on Readers' Service Card, page 73 A VOL. 2 9 , N O . 8 , AUGUST 1 9 5 7

·

21

A