AMERICAN INSTRUMENT CO., INC

to Fluorescence News sent on request. Write for Portfolio 2392AC-5. AMERICAN ... Circle No. 107 on Readers'Service Card. 94 A ·. ANALYTICAL CHEMISTRY...
2 downloads 0 Views 112KB Size
The SPF's ability to show superior sensitivity and high resolution simultaneously is shown in the curve. See data block for details. κ»

EXCITATION i EMISSION SPECTRA SAMPLE: SOLVENT: Anthracene in Cyctohewne CONCENTRATION: 1 ppb mg. p f m l MM: .003 SENSITIVITY: 50 PM TUBE: 1P21 LAMP: Xe Standard TEMP. °K

βο

DATE: 7-28-67

βο

OBSERVER: C. Schwartz

SUT * " SHUTTER Î 52 Β 5.0 C 0.5 D 5.0 Ε 1.0 ] SAMPLE TUBE REMARKS: Excitation at 250 π m

το

ζ

PORTS 'OPENING » ' » mm I.D.

Ζ ~ βο



3 «-ο so

4

20

ΙΟ 200

NEW

2 SO

SOO

3 BO

400

4SO BOO BBO WAVELENGTH—M1LLI MICRONS

βΟΟ

«SO

700

7BO

βΟΟ

R E A S O N S WHY THE AMINCO-BOWMAN S P F IS BETTER THAN ANY OTHER SPECTROPHOTOFLUOROMETER NOW AVAILABLE Increased Sensitivity: 17 times the sensitivity of the closest competitive instrument (the old Aminco-Bowman SPF) while still maintaining high resolution. Limits of detection are now 3 parts per trillion for quinine sulfate when excited at 350 nm and 2 parts per trillion when excited at 250 nm—an unprecedented UV sensitivity. Limit of detection for antracene when excited at 250 nm is 4 parts per trillion. The above sensitivities are measured with a signal-to-noise ratio of 10:1, with the noise level less than 0 . 5 % of full scale. Greater Resolution: Adjustable monochromator mirrors focus at the defining slit of each monochromator, giving each of them a resolution of 0.65 nm. Previous monochromators were focused in the sample cell. When 0.1 mm slits are used the overall resolution is less than 1 nm, while still maintaining high sensitivity.

3.

Complete Temperature Stability: New standard constant-temperature cell compartment may be connected to accessory constant-temperature baths or customer's liquid or gas coolant source to maintain desired temperature in sample cell. Improved lamp housing maintains the lamp at an optimum temperature for increased ultraviolet life.

4.

Less Noise: A new power supply reduces instrument's 0 . 2 5 % down to 0 . 1 % in xenon pulsing and arc wander. A modular the instrument, allowing the new power 12 feet.

Product bulletin, actual curves showing the sensitivity and linearity described to Fluorescence News sent on request. Write for Portfolio 2392AC-5.

AMINCO



ANALYTICAL CHEMISTRY

above and a complementary

subscription

AMERICAN INSTRUMENT CO., INC. 8 0 3 0 Georgia Avenue, Silver Spring, Maryland 2 0 9 1 0 Circle No. 107 on Readers' Service Card

94 A

AC ripple from the previous the new SPF, and reduces striker can be mounted near supply to be stored within