Anion Sensing by Novel Triarylboranes Containing Boraanthracene

Mar 1, 2019 - Department of Chemical Sciences, Indian Institute of Science Education and Research Berhampur , Government ITI Campus, Engineering ...Mi...
6 downloads 0 Views 6MB Size
This is an open access article published under an ACS AuthorChoice License, which permits copying and redistribution of the article or any adaptations for non-commercial purposes.

Article Cite This: ACS Omega 2019, 4, 4505−4518

http://pubs.acs.org/journal/acsodf

Anion Sensing by Novel Triarylboranes Containing Boraanthracene: DFT Functional Assessment, Selective Interactions, and Mechanism Demonstration Haamid Rasool Bhat, Parth Sarthi Sen Gupta, Satyaranjan Biswal, and Malay Kumar Rana* Department of Chemical Sciences, Indian Institute of Science Education and Research Berhampur, Government ITI Campus, Engineering School Road, Ganjam, Berhampur 760010, Odisha, India

ACS Omega 2019.4:4505-4518. Downloaded from pubs.acs.org by 94.231.218.221 on 03/03/19. For personal use only.

S Supporting Information *

ABSTRACT: Analytical methods often involve expensive instrumentation and tedious sample pretreatment for an analyte detection. Being toxic and detrimental to human health, sensing of cyanide (CN−), fluoride (F−), chloride (Cl−), bromide (Br−), nitrate (NO3−), acetate (CH3COO−), and bisulfate (HSO4−) is performed by a boron-based molecular receptor, N,N,N,3,5-pentamethyl-4-{2-thia-9boratricyclo[8.4.0.03,8]tetradeca-1(10),3(8),4,6,11,13-hexaen9-yl}anili-nium (1), and the three newly designed receptors from it. Thermodynamics, electronic structure, and photophysical properties are computed by employing density functional theory (DFT) and time-dependent density functional theory (TD-DFT) to explore selective sensing of these anions and its mechanism. Free-energy changes (ΔG) and binding energies (ΔE) suggest that among these anions, only binding of CN− and F− is thermodynamically feasible with a very strong binding affinity with the receptors. Boron atoms containing positive natural charges act as the electrophilic centers to bind the anions involving a 2p−2p orbital overlap resulting in charge transfer. In the receptor−analyte complexes with CN− and F−, fluorescence is quenched due to the intramolecular charge transfer transitions (π−π* transitions in the case of the receptors lead to fluorescence), internal conversion, and associated configurational changes. Among the six tested functionals, CAM-B3LYP/6-31G(d) is found to be the most accurate one. The designed receptors are better fluorescent probes for F− and CN−, demonstrating their importance for the practical utility.



INTRODUCTION The deadly poisonous nature of the cyanide ion (CN−) makes it very toxic to human body.1 The binding between CN− and heme unit of cytochrome c causes paralysis of the cellular respiration and ultimately leads to serious central nervous system damages.2,3 As the versatility of cyanide reagents in industry is depicted by their role in synthesis, metallurgy, etc., their release into the environment is unavoidable.4,5 On the other hand, fluoride (F−) has so many beneficial effects like treating osteoporosis, protection of dental health, etc. when consumed in a controlled manner.6,7 But fluoride overdose causes pathological disorders like skeletal and tooth fluorosis, kidney failure, urolithiasis, and may even lead to death.8−10 Thus, World Health Organization (WHO) has fixed the maximum permitted limit at 0.07 and 1.5 mg/L, respectively, for CN− and F− in drinking water.11,12 In connection to these facts and due to the continuous discharge of F− and CN− into the environment, the development of a method for the accurate trace-level quantification of these anions is indispensable. Although various analytical methods like potentiometry, absorption spectrometry, inductively coupled plasma emission spectrometry, etc. are used for detection of trace levels of F− and CN− and other anions ( 1) absorption transitions; emission occurs involving IC with a significant geometrical change to the receptor−analyte complexes unlike the emission of the receptors, which is conceived as the reason for the fluorescence quenching (f ∼ 0.0001−0.0006) upon anion binding. Natural population analysis, hybrids, and MO plots provide a clear picture of receptor−analyte interactions. The anions bind to the boron centers having partial positive charges, leading to change of hybridization from sp2 to sp3 in 1−4. Such interactions involve 2p−2p orbital overlap between the boron centers of the receptors and the anions accompanied by anion → receptor charge transfer, quantified in ΔQ. There is greater degree of charge transfer in the case of CN− (e.g., in 1CN, ΔQ = −0.6829) than F− (e.g., 1F, ΔQ = −0.4504), which may be because of the electronegativity difference between fluorine and the carbon of the cyanide analyte. Among the six different DFT functionals used, CAM-B3LYP gives the best accuracy to reproduce experimental data (geometries, absorption and emission peaks) for its augmented largest exact exchange component. The PES scanning validates the optimized geometries considered in the ground and excited states, 4515

DOI: 10.1021/acsomega.8b03237 ACS Omega 2019, 4, 4505−4518

ACS Omega

Article

Parac noted a substantial failure while estimating excitation energies for lowest-lying π → π* states in oligoacenes by using standard hybrid functionals in TD-DFT (error > 0.5 eV).74 To address this unexpected and surprising failure of TD-DFT in these simple valence excitations, Wong and co-workers75,76 and Peng et al.77 showed that some range-separated functionals,78,79 which possess both an asymptotically correct contribution of Hartree−Fock (HF) exchange and a positiondependent admixture, yield significant improvements over the conventional hybrids in the excitations of oligoacenes and DNA complexes. They observed that all full-HF-exchange LC functionals gave similar results for the linear acenes upon employing several range-separated and LC functionals like CAM-B3LYP, LC-BOP, LC-PBE, LC-ωPBE, and LC-BLYP. The CAM-B3LYP functional as defined80 has a Coulombattenuating parameter of α + β = 0.65 and −0.65/r dependence for the exchange potential. Hence, the CAMB3LYP functional is principally different from other LC functionals considered in the work of Wong and Hsieh75 because at large interelectronic distances, it does not include a full 100% HF exchange. It is also found that the previously obtained systematic errors for the acene systems by Grimme and Parac74 is mainly due to the HF exchange component rather than the specific DFT correlation contribution used because similar results were obtained from other full-exchange LC functionals as well. As the CAM-B3LYP functional cannot capture the correct 100% asymptotic distance, it gives inaccurate results. Among all of the functionals employed herein, the CAM-B3LYP, however, has the highest exchange part (65% exchange and 35% correlation); thus, it gives the better accuracy and is more reliable comparatively. In both the ground and excited states, potential energy surface (PES) scanning was done along the angles over which maximum configurational change occurs in traversing from S0 to S1 state. It is worth mentioning that the configurations at the local minima of S0 and S1 potential energy surfaces are same as those of the corresponding optimized geometries attained at CAMB3LYP/6-31G(d), validating the structural choice of optimized ions and complexes given by this method. To take into account the effect of solvation in tetrahydrofuran (THF, ε = 7.58), conductor-like polarizable continuum model (CPCM) as implemented in Gaussian 09 was used in all of the calculations.81 Natural bond orbital (NBO) method using the NBO 3.1 version as implemented in Gaussian 09 program was exploited for performing the natural population analysis at the CAM-B3LYP/6-31G(d) level of theory.82 Binding energies (ΔE) and free-energy changes (ΔG) were calculated for complexes of 1, 2, 3, and 4 with the seven different anionic analytes considered herein with the following equations ΔE = Ecomplex − (Ereceptor + Eanion)

(1)

ΔG = Gcomplex − (Greceptor + Ganion)

(2)



AUTHOR INFORMATION

Corresponding Author

*E-mail: [email protected]. Tel: +916802227753. ORCID

Haamid Rasool Bhat: 0000-0003-3889-6044 Malay Kumar Rana: 0000-0002-1713-8220 Notes

The authors declare no competing financial interest.



ACKNOWLEDGMENTS The authors acknowledge IISER Berhampur and IIT Kanpur for the computational support. H.R.B. also sincerely acknowledges IISER Berhampur for providing him the Institute Postdoc Fellowship to carry out this work. H.R.B is also thankful to Dr. Prakash Chandra Jha, Central University of Gujarat, Gandhinagar, India for important discussions and suggestions.



REFERENCES

(1) Koenig, R. Wildlife Deaths Are a Grim Wake-Up Call in Eastern Europe. Science 2000, 287, 1737−1738. (2) Chen, Y.; Deterding, L. J.; Tomer, K. B.; Mason, R. P. Nature of the Inhibition of Horseradish Peroxidase and Mitochondrial Cytochrome c Oxidase by Cyanyl Radical. Biochemistry 2000, 39, 4415−4422. (3) Shiraishi, Y.; Nakamura, M.; Hayashi, N.; Hirai, T. CoumarinSpiropyran Dyad with a Hydrogenated Pyran Moiety for Rapid, Selective, and Sensitive Fluorometric Detection of Cyanide Anion. Anal. Chem. 2016, 88, 6805−6811. (4) Yan, Z.; Caib, M.; Shen, P. K. Low Temperature Formation of Porous Graphitized Carbon for Electrocatalysis. J. Mater. Chem. 2012, 22, 2133−2139. (5) Jiang, J.; Wang, X.; Zhou, W.; Gao, H.; Wu, J. Extraction of Gold from Alkaline Cyanide Solution by the Tetradecyldimethylbenzylammonium Chloride/Tri-n-Butyl Phosphate/n-Heptane System Based on a Microemulsion Mechanism. Phys. Chem. Chem. Phys. 2002, 4, 4489−4494. (6) Zheng, X.; Zhu, W.; Liu, D.; Ai, H.; Huang, Y.; Lu, Z. Highly Selective Colorimetric/Fluorometric Dual-Channel Fluoride Ion Probe, and Its Capability of Di Ff Erentiating Cancer Cells. ACS Appl. Mater. Interfaces 2014, 6, 7996−8000. (7) Kleerekoper, M. The Role of Fluoride in the Prevention of Osteoporosis. Endocrinol. Metab. Clin. North Am. 1998, 27, 441−452. (8) Ayoob, S.; Gupta, A. K. Fluoride in Drinking Water: A Review on the Status and Stress Effects. Crit. Rev. Environ. Sci. Technol. 2006, 36, 433−487. (9) Singh, P. P.; Barjatiya, M. K.; Dhing, S.; Bhatnagar, R.; Kothari, S.; Dhar, V. Evidence Suggesting That High Intake of Fluoride

where E and G refer to total energy and Gibbs free energy, respectively. For reducing the basis set superposition error (BSSE) in these energy terms, the Boys−Bernardi scheme was used to offer the counterpoise corrected energies.83



Calculated geometrical parameters for the fully optimized structures of 1−4, 1F−4F, and 1CN−4CN in the ground and excited states and the corresponding X-ray data; excitation and de-excitation energies calculated by employing different functionals; ground-state optimized structures of 1F−4F, 1CN−4CN; excited-state optimized structures of 1−4, 1F−4F, and 1CN−4CN; potential energy curves of the ground and excited states of 1F and 2CN; calculated FMOs and their corresponding energies involved in excitation and emission of 2−4, 2F−4F, and 2CN−4CN; molecular orbital diagrams of (I) 1, (II) F−, and (III) CN−; and schemes for the different mechanisms of fluorescence emission of 2−4, 2F−4F, and 2CN−4CN (PDF)

ASSOCIATED CONTENT

S Supporting Information *

The Supporting Information is available free of charge on the ACS Publications website at DOI: 10.1021/acsomega.8b03237. 4516

DOI: 10.1021/acsomega.8b03237 ACS Omega 2019, 4, 4505−4518

ACS Omega

Article

Provokes Nephrolithiasis in Tribal Populations. Urol. Res. 2001, 29, 238−244. (10) Gessner, B. D.; Beller, M.; Middaugh, J. P.; Whitford, G. M. Acute Fluoride Poisoning from a Public Water System. N. Engl. J. Med. 1994, 330, 95−99. (11) WHO. Guidelines for Drinking-Water Quality; World Health Organization: Geneva Switzerland, 2011; p 342. (12) Yiping, H.; Caiyun, W. Ion Chromatography for Rapid and Sensitive Determination of Fluoride in Milk after Headspace SingleDrop Microextraction with in Situ Generation of Volatile Hydrogen Fluoride. Anal. Chim. Acta 2010, 661, 161−166. (13) McCabe, J. F.; Carrick, T. E.; Sidhu, S. K. Determining Low Levels of Fluoride Released from Resin Based Dental Materials. Eur. J. Oral Sci. 2002, 110, 380−384. (14) Jackson, P. E. Determination of Inorganic Ions in Drinking Water by Ion Chromatography. TrAC, Trends Anal. Chem. 2001, 20, 320−329. (15) Kovács, M.; Nagy, M. H.; Borszéki, J.; Halmos, P. Indirect Determination of Fluoride in Aqueous Samples by Inductively Coupled Plasma Atomic Emission Spectrometry Following Precipitation of CeF 3. J. Fluorine Chem. 2009, 130, 562−566. (16) Matsunaga, H.; Kanno, C.; Yamada, H.; Takahashi, Y.; Suzuki, T. M. Fluorometric Determination of Fluoride Ion by Reagent Tablets Containing 3-Hydroxy-2 -Sulfoflavone and Zirconium ( IV ) Ethylenediamine Tetraacetate. Talanta 2006, 68, 1000−1004. (17) Lou, Z.; Li, P.; Han, K. Redox-Responsive Fluorescent Probes with Different Design Strategies. Acc. Chem. Res. 2015, 48, 1358− 1368. (18) Yu, F.; Li, P.; Wang, B.; Han, K. Reversible Near-Infrared Fluorescent Probe Introducing Tellurium to Mimetic Glutathione Peroxidase for Monitoring the Redox Cycles between Peroxynitrite and Glutathione in Vivo. J. Am. Chem. Soc. 2013, 135, 7674−7680. (19) Yu, F.; Li, P.; Li, G.; Zhao, G.; Chu, T.; Han, K. A Near-IR Reversible Fluorescent Probe Modulated by Selenium for Monitoring Peroxynitrite and Imaging in Living Cells. J. Am. Chem. Soc. 2011, 133, 11030−11033. (20) Hu, R.; Feng, J.; Hu, D.; Wang, S.; Li, S.; Li, Y.; Yang, G. A Rapid Aqueous Fluoride Ion Sensor with Dual Output Modes. Angew. Chem. 2010, 122, 5035−5038. (21) Zhu, B.; Yuan, F.; Li, R.; Li, Y.; Wei, Q.; Ma, Z.; Du, B.; Zhang, X. A Highly Selective Colorimetric and Ratiometric Fluorescent Chemodosimeter for Imaging Fluoride Ions in Living Cells. Chem. Commun. 2011, 47, 7098−7100. (22) Kubo, Y.; Yamamoto, M.; Ikeda, M.; Takeuchi, M.; Shinkai, S.; Yamaguchi, S.; Tamao, K. A Colorimetric and Ratiometric Fluorescent Chemosensor with Three Emission Changes: Fluoride Ion Sensing by a Triarylborane− Porphyrin Conjugate. Angew. Chem., Int. Ed. 2003, 42, 2036−2040. (23) El-Ballouli, A. O.; Zhang, Y.; Barlow, S.; Marder, S. R.; AlSayah, M. H.; Kaafarani, B. R. Fluorescent Detection of Anions by Dibenzophenazine-Based Sensors. Tetrahedron Lett. 2012, 53, 661− 665. (24) Lee, D. Y.; Singh, N.; Satyender, A.; Jang, D. O. An Azo DyeCoupled Tripodal Chromogenic Sensor for Cyanide. Tetrahedron Lett. 2011, 52, 6919−6922. (25) Li, G.-Y.; Zhao, G.; Liu, Y.; Han, K.; He, G. TD-DFT Study on the Sensing Mechanism of a Fluorescent Chemosensor for Fluoride: Excited-State Proton Transfer. J. Comput. Chem. 2010, 31, 1759− 1765. (26) Li, G.-Y.; Zhao, G.; Han, K.-L.; He, G.-Z. A TD-DFT Study on the Cyanide-Chemosensing Mechanism of 8-Formyl-7-Hydroxycoumarin. J. Comput. Chem. 2011, 32, 668−674. (27) Lee, J. H.; Reum Jeong, A.; Shin, I. S.; Kim, H. J.; Hong, J. I. Fluorescence Turn-on Sensor for Cyanide Based on a Cobalt(II)Coumarinylsalen Complex. Org. Lett. 2010, 12, 764−767. (28) Zou, Q.; Li, X.; Zhang, J.; Zhou, J.; Sun, B.; Tian, H. Unsymmetrical Diarylethenes as Molecular Keypad Locks with Tunable Photochromism and Fluorescence via Cu 2 + and CN À Coordinations W. Chem. Commun. 2012, 48, 2095−2097.

(29) Jo, J.; Olasz, A.; Chen, C.; Lee, D. Interdigitated Hydrogen Bonds: Electrophile Activation for Covalent Capture and Fluorescence Turn-On Detection of Cyanide. J. Am. Chem. Soc. 2013, 135, 3620−3632. (30) Goswami, S.; Manna, A.; Paul, S.; Das, A. K.; Aich, K.; Nandi, P. K. Resonance-Assisted Hydrogen Bonding Induced Nucleophilic Addition to Hamper ESIPT: Ratiometric Detection of Cyanide in Aqueous Media. Chem. Commun. 2013, 49, 2912−2914. (31) Cheng, X.; Zhou, Y.; Qin, J.; Li, Z. Reaction-Based Colorimetric Cyanide Chemosensors: Rapid Naked- Eye Detection and High Selectivity. ACS Appl. Mater. Interfaces 2012, 4, 2133−2138. (32) Pramanik, S.; Bhalla, V.; Kumar, M. Hexaphenylbenzene-Based Fluorescent Aggregates for Ratiometric Detection of Cyanide Ions at Nanomolar Level: Set−Reset Memorized Sequential Logic Device. ACS Appl. Mater. Interfaces 2014, 6, 5930−5939. (33) Lim, B.; Lee, J. A Peptoid-Based Fluorescent Sensor for Cyanide Detection. Molecules 2016, 21, 339−351. (34) Sukato, R.; Sangpetch, N.; Palaga, T.; Jantra, S.; Vchirawongkwin, V.; Jongwohan, C.; Sukwattanasinitt, M.; Wacharasindhu, S. New Turn-on Fluorescent and Colorimetric Probe for Cyanide Detection Based on BODIPY-Salicylaldehyde and Its Application in Cell Imaging. J. Hazard. Mater. 2016, 314, 277−285. (35) Badugu, R.; Lakowicz, J. R.; Geddes, C. D. Fluorescence Intensity and Lifetime-Based Cyanide Sensitive Probes for Physiological Safeguard. Anal. Chim. Acta 2004, 522, 9−17. (36) Kumari, N.; Jha, S.; Bhattacharya, S. Colorimetric Probes Based on Anthraimidazolediones for Selective Sensing of Fluoride and Cyanide Ion via Intramolecular Charge Transfer. J. Org. Chem. 2011, 76, 8215−8222. (37) Li, Q.; Cai, Y.; Yao, H.; Lin, Q.; Zhu, Y. R.; Li, H.; Zhang, Y. M.; Wei, T. B. A Colorimetric and Fluorescent Cyanide Chemosensor Based on Dicyanovinyl Derivatives: Utilization of the Mechanism of Intramolecular Charge Transfer Blocking. Spectrochim. Acta, Part A 2015, 136, 1047−1051. (38) Bauman, A. Natriumtriphenylcyanoborat– Caisignost– Ein Selektives Reagens Zur 137Cs-Trennung in Umweltproben. Mikrochim. Acta 1977, 69−72. (39) Parab, K.; Venkatasubbaiah, K.; Jackle, F. Luminescent Triarylborane-Functionalized Polystyrene: Synthesis, Photophysical Characterization, and Anion-Binding Studies. J. Am. Chem. Soc. 2006, 128, 12879−12885. (40) Matsumoto, T.; Wade, C. R.; Gabbaï, F. P. Synthesis and Lewis Acidic Behavior of a Cationic 9-Thia-10-Boraanthracene. Organometallics 2010, 29, 5490−5495. (41) Yang, Z.; Liu, Z.; Chen, Y.; Wang, X.; He, W.; Lud, Y. A New Ratiometric and Colorimetric Chemosensor for Cyanide Anion Based on Coumarin−hemicyanine Hybrid. Org. Biomol. Chem. 2012, 10, 5073−5076. (42) Li, G.; Song, P.; He, G. TDDFT Study on Different Sensing Mechanisms of Similar Cyanide Sensors Based on Michael Addition Reaction. Chin. J. Chem. Phys. 2011, 24, 305−310. (43) Mahapatra, A. K.; Maiti, K.; Maji, R.; Manna, S. K.; Mondal, S.; Ali, S. S.; Manna, S. Ratiometric Fluorescent and Chromogenic Chemodosimeter for Cyanide Detection in Water and Its Application in Bioimaging†. RSC Adv. 2015, 5, 24274−24280. (44) Konidena, R. K.; Thomas, K. R. J. Selective Naked-Eye Cyanide Detection in Aqueous Media Using a Carbazole-Derived Fluorescent Dye. RSC Adv. 2014, 4, 22902−22910. (45) Bhat, H. R.; Jha, P. C. Cyanide Anion Sensing Mechanism of 1,3,5,7-Tetratolyl Aza-BODIPY: Intramolecular Charge Transfer and Partial Configuration Change. Chem. Phys. Lett. 2017, 669, 9−16. (46) Bhat, H. R.; Jha, P. C. Intramolecular Charge Transfer: Mechanism Behind Cyanide Anion Sensing of 3,5-DiformylBorondipyrromethene. ChemistrySelect 2017, 2, 2732−2739. (47) Gutberlet, A.; Schwaab, G.; Birer, Ö .; Masia, M.; Kaczmarek, A.; Forbert, H.; Havenith, M.; Marx, D. Aggregation-Induced Dissociation of HCl(H2O)4 Below 1K: The Smallest Droplet of Acid. Science 2009, 1545−1548. 4517

DOI: 10.1021/acsomega.8b03237 ACS Omega 2019, 4, 4505−4518

ACS Omega

Article

(48) Kiyabu, S.; Lowe, J. S.; Ahmed, A.; Siegel, D. J. Computational Screening of Hydration Reactions for Thermal Energy Storage: New Materials and Design Rules. Chem. Mater. 2018, 2006−2017. (49) Plasser, F.; Dreuw, A. High-Level Ab Initio Computations of the Absorption Spectra of Organic Iridium Complexes. J. Phys. Chem. A 2015, 119, 1023−1036. (50) Davidson, R. S. The Chemistry of Excited Complexes: A Survey of Reactions. Adv. Phys. Org. Chem. 1983, 19, 1−130. (51) Zhao, G. J.; Han, K. Hydrogen Bonding in the Electronic Excited State. Acc. Chem. Res. 2012, 45, 404−413. (52) Zhao, G. J.; Han, K. Role of Intramolecular and Intermolecular Hydrogen Bonding in Both Singlet and Triplet Excited States of Aminofluorenones on Internal Conversion, Intersystem Crossing, and Twisted Intramolecular Charge Transfer. J. Phys. Chem. A 2009, 113, 14329−14335. (53) Zhao, G.; Han, K. Time-Dependent Density Functional Theory Study on Hydrogen-Bonded Intramolecular Charge-Transfer Excited State of 4-Dimethylamino-Benzonitrile in Methanol. J. Comput. Chem. 2008, 29, 2010−2017. (54) Zhao, G. J.; Han, K. PH-Controlled Twisted Intramolecular Charge Transfer ( TICT ) Excited State via Changing the Charge Transfer Direction. Phys. Chem. Chem. Phys. 2010, 12, 8914−8918. (55) Qian, X.; Lusby, P. J.; Qian, X.; Xiao, Y.; Xu, Y.; Guo, X. ‘“Alive”’ Dyes as Fluorescent Sensors: Fluorophore, Mechanism, Receptor and Images in Living Cells. Chem. Commun. 2010, 46, 6418−6436. (56) Fidder, H.; Rini, M.; Nibbering, E. T. J. The Role of Large Conformational Changes in Efficient Ultrafast Internal Conversion: Deviations from the Energy Gap Law. J. Am. Chem. Soc. 2004, 126, 3789−3794. (57) Lou, Z.; Li, P.; Pan, Q.; Han, K. A Reversible Fluorescent Probe for Detecting Hypochloric Acid in Living Cells and Animals: Utilizing a Novel Strategy for Effectively Modulating the Fluorescence of Selenide and Selenoxide. Chem. Commun. 2013, 49, 2445−2447. (58) Kasha, M. Characterization of Electronic Transitions in Complex Molecules. Discuss. Faraday Soc. 1950, 9, 14−19. (59) Wen, Z.; Jiang, Y. Ratiometric Dual Fluorescent Receptors for Anions under Intramolecular Charge Transfer Mechanism. Tetrahedron 2004, 60, 11109−11115. (60) Frisch, M. J.; Trucks, G. W.; Schlegel, H. B.; Scuseria, G. E.; Robb, M. A.; Cheeseman, J. R.; Scalmani, G.; Barone, V.; Mennucci, B.; Petersson, G. A.;et al. Gaussian 09; Gaussian Inc: Wallingford, CT, 2009. (61) Furche, F.; Ahlrichs, R. Adiabatic Time-Dependent Density Functional Methods for Excited State Properties. J. Chem. Phys. 2002, 117, 7433−7447. (62) Scalmani, G.; Frisch, M. J.; Mennucci, B.; Tomasi, J.; Cammi, R.; Barone, V. Geometries and Properties of Excited States in the Gas Phase and in Solution: Theory and Application of a Time-Dependent Density Functional Theory Polarizable Continuum Model Geometries and Properties of Excited States in the Gas Phase and in Solution. J. Chem. Phys. 2006, 124, No. 094107. (63) Jacquemin, D.; Planchat, A.; Adamo, C.; Mennucci, B. TDDFT Assessment of Functionals for Optical 0-0 Transitions in Solvated Dyes. J. Chem. Theory Comput. 2012, 8, 2359−2372. (64) Santoro, F.; Jacquemin, D. Going beyond the Vertical Approximation with Time- Dependent Density Functional Theory. Wiley Interdiscip. Rev.: Comput. Mol. Sci. 2016, 460−486. (65) Jacquemin, D.; Wathelet, V.; Perpe, E. A.; Adamo, C. Extensive TD-DFT Benchmark: Singlet-Excited States of Organic Molecules. J. Chem. Theory Comput. 2009, 5, 2420−2435. (66) Peach, M. J.; Benfield, P.; Helgaker, T.; Tozer, D. J. Excitation Energies in Density Functional Theory: An Evaluation and a Diagnostic Test. J. Chem. Phys. 2008, 128, No. 044118. (67) Francl, M. M.; Pietro, W. J.; Hehre, W. J.; et al. Self-Consistent Molecular Orbital Methods. XXIII. A Polarization-Type Basis Set for Second-Row Elements. J. Chem. Phys. 1982, 77, 3654−3665.

(68) Kumar, G. R.; Thilagar, P. Dicyanovinyl Substituted Triarylboranes: A Rational Approach to Distinguish Fluoride and Cyanide Ions. Dalton Trans. 2014, 43, 7200−7207. (69) Parab, K.; Venkatasubbaiah, K.; Jäkle, F. Luminescent Triarylborane-Functionalized Polystyrene: Synthesis, Photophysical Characterization, and Anion-Binding Studies. J. Am. Chem. Soc. 2006, 128, 12879−12885. (70) Song, K. C.; Kim, H.; Mun, K.; Sup, Y.; Do, Y.; Hyung, M. Ratiometric Fluorescence Sensing of Fluoride Ions by Triarylborane− phenanthroimidazole Conjugates. Sens. Actuators, B 2013, 176, 850− 857. (71) Li, G.; Chu, T. TD-DFT Study on Fluoride-Sensing Mechanism of 2-(2′-Phenylureaphenyl)Benzoxazole: The Way to Inhibit the ESIPT Process. Phys. Chem. Chem. Phys. 2011, 13, 20766− 20771. (72) Bhat, H. R.; Jha, P. C. Selective Complexation of Cyanide and Fluoride Ions with Ammonium Boranes: A Theoretical Study on Sensing Mechanism Involving Intramolecular Charge Transfer and Configurational Changes. J. Phys. Chem. A 2017, 121, 3757−3767. (73) Bhat, H. R.; Jha, P. C. A Theoretical Study on Anion Sensing Mechanism of Multi-Phosphonium Triarylboranes: Intramolecular Charge Transfer and Configurational Changes. Phys. Chem. Chem. Phys. 2017, 19, 14811−14820. (74) Grimme, S.; Parac, M. Substantial Errors from TimeDependent Density Functional Theory for the Calculation of Excited States of Large p Systems. ChemPhysChem 2003, 4, 292−295. (75) Wong, B. M.; Hsieh, T. H. Optoelectronic and Excitonic Properties of Oligoacenes: Substantial Improvements from RangeSeparated Time-Dependent Density Functional Theory. J. Chem. Theory Comput. 2010, 6, 3704−3712. (76) Raeber, A. E.; Wong, B. M. The Importance of Short- and Long-Range Exchange on Various Excited State Properties of DNA Monomers, Stacked Complexes, and Watson−Crick Pairs. J. Chem. Theory Comput. 2015, 11, 2199−2209. (77) Peng, W.; Chai, J. Assessment of Asymptotically Corrected Model Potentials for Charge-Transfer-like Excitations in Oligoacenes. Phys. Chem. Chem. Phys. 2014, 16, 21564−21569. (78) Leininger, T.; Stoll, H.; Werner, H.; Savin, A. Combining LongRange Configuration Interaction with Short-Range Density Functionals. Chem. Phys. Lett. 1997, 275, 151−160. (79) Sato, T.; Tsuneda, T.; Hirao, K. Van Der Waals Interactions Studied by Density Functional Theory. Mol. Phys. 2005, 103, 1151− 1164. (80) Yanai, T.; Tew, D. P.; Handy, N. C. A New Hybrid ExchangeCorrelation Functional Using the Coulomb-Attenuating Method (CAM-B3LYP). Chem. Phys. Lett. 2004, 393, 51−57. (81) Tomasi, J.; Persico, M. Molecular Interactions in Solution: An Overview of Methods Based on Continuous Distributions of the Solvent. Chem. Rev. 1994, 94, 2027−2094. (82) Reed, A. E.; Curtiss, L.; Weinhold, F. Intermolecular Interactions from a Natural Bond Orbital, Donor-Acceptor Viewpoint. Chem. Rev. 1988, 88, 899−926. (83) Boys, S. F.; Bernardi, F. The Calculation of Small Molecular Interactions by the Differences of Separate Total Energies. Some Procedures with Reduced Errors. Mol. Phys. 1970, 19, 553−566.

4518

DOI: 10.1021/acsomega.8b03237 ACS Omega 2019, 4, 4505−4518