arthur h. thomas co. - ACS Publications

47 A. 60 A. 67 A-2. 75 A-1. 84 A-1. 89 A-1. AmOi-McCRONE. MICRO COLD STAGE. For use in micro fusion studies over the range —100°C to +70°C. MICRO ...
6 downloads 14 Views 165KB Size
READERS' INFORMATION SERVICE Refractometers, Chromatographic . 86 A-l Regulators, Voltage 86 A-2 Shakers 27 A-l Spectrographs 90 A-2 Spectrometers 88 A Spectrophotometers 3 A, 41 A, 46 A-l, 54 A, 80 A Stirrers 27 A-3, 34 A-2 Syringes 72 A-2 Transformers 31A Tubing, Plastic 82 A Valves, Globe 85 A-2 Voltage Regulators 34 A-l Voltage Stabilizers 73 A-2 X-ray Diffraction Unit 33 A

Carbon Monoxide Chemicals Cleaners Film Filter Paper Samplers Filters Filters, Ultra Lithium Compounds Nitric Acid Organic Chemicals Thioacetamide

40 A-2 90 A-l 65 A-2 62 A 37 A 62 A 37 A 75 A 8A 62 A 19 A

^OftS&t-McCRONE

MICRO COLD STAGE

MISCELLANEOUS CHEMICALS AND MATERIALS Adsorbents Bromine

Infrared Solvent Reprints Instrument Publications Scientific Books

69 A 12 A

46 A-3 46 A-4 61 A

For use in micro fusion studies over the range — 100°C to +70°C MICRO COLD STAGE (Micro Melting Point Apparatut), Thomai-McCrone Thermometer

Reading Model. Based on the design described in Analytical Chemistry, Vol. 28, No. 6 (June, 1956), p. 10S8. Provides close temperature control within a working range of -100°C to + 70°C. Bevelled cut-out in top of stage takes a standard 10 X objective. Simplified for convenient insertion of sample and reproducible placement of interchangeable, low temperature thermometers. Heating is by means of a Pyrex brand E-C Radiant Glass plate. Voltage on the heating unit should not exceed 80 volts and a special Variable Transformer is included with the Stage. The manipulator rod for seeding, etc., is inserted into the working chamber through a ball joint. Thermometers are inserted from the side. In use, a stream of inert, precooled gas is passed over the sample and escapes from the stage through a small annular space around the objective. Moisture is removed from the gas stream in a simple Cooling Device, thus minimizing possible icing of the objective.

FIRST CLASS PERMIT NO. 1538 (Sec. 34.9, P.L.&R.) NEW YORK, Ν. Υ.

BUSINESS REPLY CARD NO POSTAGE STAMP NECESSARY IF MAILED IN THE UNITED STATES

READERS' INFORMATION SERVICE Analytical Chemistry 430 Park Avenue s ε m V

a Ζ

!

New York 22, Ν. Υ.

I

READERS' INFORMATION CARD—ANALYTICAL CHEMISTRY NEW PRODUCTS

1

2

3

NEW CHEMICALS

12

13

14

15

MANUFACTURERS' LITERATURE

16 27

17 28

18 29

19 30

ADVERTISED PRODUCTS 3 A 24 A 6 A 26 A 7 A 27 A - 1 8 A 27 A - Ï 10 A 27 A - 3 12 A 28 A-1 14 A 28 A - 2 16 A 29 A 18 A 30 A 19 A 32 A 20 A 33 A 21 A 34 A-1 22 A 34 A - 2 23 A 35 A PRODUCT CAPSULES 3 A 22 A 28 6 A 23 A - 1 30 8 A 23 A - 2 31 10 A 24 A-1 31 12 A 24 A - 2 32 14 A 24 A - 3 32 16 A 24 A - 4 33 17 A 25 A 34 18 A 26 A - 1 35 19 A 26 A - 2 37 20 A 27 A - 1 37 21 A 27 A - 2 38

37 38 39 40 40 41 42 43 43 43 44 45 45 46

A A A-1 A-2 A-1 A-2 A A A A-1 A-2 A

A A A A-1 A-2 A A A-1 A-2 A-3 A A-1 A-2 A-1

39 40 41 42 43 43 44 45 45 45 46 47

46 46 46 47 48 51 52 54 55 55 56 57 58 59

A A A A A-1 A-2 A A-1 A-2 A-3 A A

A-2 A-3 A-4 A A A A A A-1 A-2 A A A A

48 48 48 49 53 54 56 56 57 58 59 60

A-1 A-2 A-3 A A A A-1 A-2 A A A A

4

5

JUNE 1 9 5 7 — V a l i d through Nov. 1957 6

20 31

61 62 64 64 65 65 66 66 67 68 68 68 69 70

61 62 64 64 65 65 65 65 66 66 67 67

21 32

A A A-1 A-2 A-1 A-2 A-1 A-2 A A-1 A-2 A-3 A A-1

A A A-1 A-2 A-1 A-2 A-3 A-4 A-1 A-2 A-1 A-2

7

70 71 71 72 72 73 73 74 74 75 76 78 79 79

68 70 71 72 72 73 73 73 74 74 74 75

A A A A-1 A-2 A-1 A-2 A-3 A-1 A-2 A-3 A-1

8 22 33

9 23 34

A-2 A-1 A-2 A-1 A-2 A-1 A-2 A-1 A-2 A A A A-1 A-2

75 76 76 76 76 78 79 80 80 82 83 84

80 82 83 84 84 85 85 85 86 86 87 87 87 88

A-2 A-1 A-2 A-3 A-4 A A A-1 A-2 A A A-1

24 35

10

ft

25 36

26

A A A A-1 A-2 A-1 A-2 A-3 A-1 A-2 A-1 A-2 A-3 A

89 A - 1 89 A - 2 89 A - 3 90 A-1 90 A - 2 91 A-1 91 A - 2 94 A 2nd Cover 3rd Cover 4th Cover

84 84 84 85 86 86 87 87 87 87 88 89

89 A - 2 89 A - 3 89 A - 4 90 A - 1 90 A - 2 91 A-1 91 A - 2 2nd Covtf 3rd Cov«r 4th Cover

A-2 A-3 A-4 A A-1 A-2 A-1 A-2 A-3 A-4 A A-1

6892-6. Micro Cold Stage (Micro Melting Point Apparatus), Thomas-McCrone, with manipulator rod; two thermometers; extra E-C Radiant Glass heating unit; Powerstat voltage transformer; and 6-ft.cord and plug. For use on 115 volts, 60 cycles, a.e. only 179.25 6893-N. "Fusion Method· in Chemical Microscopy", by Walter C. McCrone f/nferscience Publishers, Inc., 1957), 328-pp. Includes techniques for Thomas-McCrone Cold Stage 6.75

More detailed information sent upon request

ARTHUR H. THOMAS CO. Laboratory Apparatus and

Reagents

VINE ST. A T THIRD

PHILADELPHIA 5, PA. More and more laboratories « I V ON THOMAS Circle No. 71A on Readers' Service Card, page 77 A