Associated Electrical Industries Limited Instrumentation Division

May 18, 2012 - Associated Electrical Industries Limited Instrumentation Division. Anal. Chem. , 1964, 36 (3), pp 102A–102A. DOI: 10.1021/ac60209a792...
1 downloads 0 Views 392KB Size
Something new — s p a r k s o u r c e m a s s s p e c t r o s c o p i c a n a l y s i s off p o w d e r s Shown above are mass spectra of three t i t a n i u m dioxide samples. T i t a n i u m Dioxide, widely used as a pigment base and plastics filler must have m a x i m u m freedom f r o m deleterious impurities w h i c h might cause physical degradation of the finished product. These three spectra are of samples from different sources. The impurities can be seen and measured quite readily; sample ' C is the purest. Compound electrode t e c h n i q u e s have opened up new f elds of application for the AEI MS7 Spark Source mass spectrometer. Now for the first time t h e purity of a c o m p o u n d in powder form can be determined and measured to 0.01 ppm by this method. The t e c h n i q u e is simple, and an analyst can be trained in a f e w days both to operate the MS7 and interpret his results. Equal amounts of the powder and spectroscopic grade graphite are c o m p o u n d e d and formed into homogeneous electrodes; o n sparking, ions for analysis are formed that are truly representative of the sample. A s the tolerance level in impurities in materials falls, quick and economical methods of analysis become more and more important. To find out more about how your time and money can be saved please ask for technical information sheets about the

AEI MS7 SPARK SOURCE MASS SPECTROMETER In t h e U S A , t e c h n i c a l l i t e r a t u r e o n A E I Mass S p e c t r o m e t e r s NEW

is available f r o m

NUCLEAR A N D A N A L Y T I C A L D I V I S I O N , PICKER X-RAY CORPORATION, W H I T E PLAINS,

YORK, U.S.A. Elsewhere w r i t e to A E I I N S T R U M E N T A T I O N DIVISION, SCIENTIFIC A P P A R A T U S DEPARTMENT, B A R T O N D O C K R O A D , U R M S T O N , MANCHESTER, ENGLAND

AEI)

Associated Electrical Industries Limited

"***• « * ^

Instrumentation Division Circle No. 19 on Readers' Service Card

196α CATALOG

now available Includes such items as: \ \

';,

A Continuous Refractive Index Monitors Β McCarter Sublimers C Rotary Spray Evapo-

Call or write for your copy today. NESTER/FAUST manufacturing corporation 2401 OGLETOWN RD. • NEWARK, DELAWARE PHONE 302-368-9146

N E S T E R F A U S T

Circle No. 162 on Readers' Service Card 102 A

·

ANALYTICAL CHEMISTRY

Circle No. 68 on Readers' Service Card

?-