Automated Online Optical Biosensing System for Continuous Real

Mar 20, 2013 - State Key Joint Laboratory of ESPC, School of Environment, ... automated online optical biosensing system (AOBS) was developed for the ...
2 downloads 0 Views 1MB Size
Article pubs.acs.org/est

Automated Online Optical Biosensing System for Continuous RealTime Determination of Microcystin-LR with High Sensitivity and Specificity: Early Warning for Cyanotoxin Risk in Drinking Water Sources Han-Chang Shi,*,† Bao-Dong Song,† Feng Long,*,‡ Xiao-Hong Zhou,† Miao He,† Qing Lv,§ and Hai-Yang Yang† †

State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing, China School of Environment and Natural Resources, Renmin University of China, Beijing, China § Suzhou Environmental Monitor Centre, Suzhou City, Jiangsu, China ‡

S Supporting Information *

ABSTRACT: The accelerated eutrophication of surface water sources and climate change have led to an annual occurrence of cyanobacterial blooms in many drinking water resources. To minimize the health risks to the public, cyanotoxin detection methods that are rapid, sensitive, real time, and high frequency must be established. In this study, an innovative automated online optical biosensing system (AOBS) was developed for the rapid detection and early warning of microcystin-LR (MC-LR), one of the most toxic cyanotoxins and most frequently detected in environmental water. In this system, the capturing molecular MC-LR-ovalbumin (MCLR-OVA) was covalently immobilized onto a biochip surface. By an indirect competitive detection mode, samples containing different concentrations of MC-LR were premixed with a certain concentration of fluorescence-labeled anti-MC-LR-mAb, which binds to MC-LR with high specificity. Then, the sample mixture was pumped onto the biochip surface, and a higher concentration of MC-LR led to less fluorescence-labeled antibody bound onto the biochip surface and thus to lower fluorescence signal. The quantification of MCLR ranges from 0.2 to 4 μg/L, with a detection limit determined as 0.09 μg/L. The high specificity and selectivity of the sensor were evaluated in terms of its response to a number of potentially interfering cyanotoxins. Potential interference of the environmental sample matrix was assessed by spiked samples, and the recovery of MC-LR ranged from 90 to 120% with relative standard deviation values 20 μg/L, no obvious fluorescence was observed, indicating that most of the antibody active sites had been occupied by free MC-LR and few antibodies bound to the MC-LR immobilized onto the biochip surface. These results demonstrated a high ability of the biochip for detecting the binding between specific antibody and MCLR, and also proved that the nonspecific adsorption of antibody onto the biochip surface was negligible. The main advantage of biosensing assays over other immnunological methods (e.g., ELISA) is the better regeneration and binding properties of the sensing surface, which is critical to the practical application of a biosensing system and the accuracy of detection results.18,19 In the present study, the stability and activity of an MC-LR conjugate immobilized immunosurface was evaluated through a large number of immunoassays (Figure S4). In these assays, the immobilized recognition element retained at least 100 successive assays devoid of any significant loss of performance (