Background Concentrations of Polychlorinated Dibenzo-p-Dioxins

Aug 1, 2014 - To the best of our knowledge, this is the first coherent data set on the ..... K. C. Dioxins in the environment: A review of trend data ...
0 downloads 0 Views 6MB Size
Subscriber access provided by UniSA Library

Article

BACKGROUND CONCENTRATIONS OF POLYCHLORINATED DIBENZO-p-DIOXINS, DIBENZOFURANS AND BIPHENYLS IN THE GLOBAL OCEANIC ATMOSPHERE Laura Morales, Jordi Dachs, Belén González-Gaya, Gema Hernán, Manuela Abaos Abalos, and Esteban Abad Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/es5023619 • Publication Date (Web): 01 Aug 2014 Downloaded from http://pubs.acs.org on August 11, 2014

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 26

Environmental Science & Technology

1

Submitted to Environmental Science & Technology

2 3

BACKGROUND CONCENTRATIONS OF POLYCHLORINATED DIBENZO-p-

4

DIOXINS, DIBENZOFURANS AND BIPHENYLS IN THE GLOBAL OCEANIC

5

ATMOSPHERE

6 7

Laura Morales, Jordi Dachs, Belén González-Gaya, Gema Hernán, Manuela Ábalos,

8

Esteban Abad*

9

Department of Environmental Chemistry, IDAEA-CSIC, Barcelona, Catalunya, Spain

10

*Corresponding author email: [email protected]

11 12

Abstract

13

The remote oceans are among the most pristine environments in the world, away from sources

14

of anthropogenic persistent organic pollutants (POP), but nevertheless recipient of atmospheric

15

deposition of POPs that have undergone long range atmospheric transport (LRAT). In this work,

16

the background occurrence of gas and aerosol phase polychlorinated dibenzo-p-dioxins and

17

dibenzofurans (PCDD/Fs), and dioxin like polychlorinated biphenyls (dl-PCB) is evaluated for

18

the first time in the atmosphere of the tropical and subtropical Atlantic, Pacific and Indian

19

oceans. Thirty nine air samples were collected during the eight months Malaspina

20

circumnavigation cruise on board the R/V Hespérides. The background levels of dioxins and dl-

21

PCBs remained very low and in many cases very close or below the limit of detection.

22

Expectedly, the levels of PCBs were higher than dioxins being PCB#118 the most abundant

23

compound. In the particular case of dioxins, octachlorodibenzo-p-dioxin (OCDD) was the most

24

abundant PCDD/F congener. Distribution of dl-PCB is dominated by the gas phase, while for

25

PCDD/F the aerosol phase concentrations were higher, particularly for the more hydrophobic

26

congeners. The Atlantic Ocean presented on average the highest PCDD/F and dl-PCB

27

concentrations being lower in the southern hemisphere. The assessment of air mass back

28

trajectories show a clear influence of continental source regions, and lower concentrations when

29

the air mass has an oceanic origin. In addition, the samples affected by an oceanic air-mass are

30

characterized by a lower contribution of the less chlorinated dioxins in comparison with the

31

furans, consistent with the reported higher reaction rate constants of dibenzo-p-dioxins with OH

1 ACS Paragon Plus Environment

Environmental Science & Technology

Page 2 of 26

32

radicals than those of dibenzofurans. The total dry atmospheric deposition of aerosol-bound

33

∑PCDD/F and ∑dl-PCB to the global oceans was estimated to be 354 and 896 Kg/year,

34

respectively.

35 36

Introduction

37

Persistent organic pollutants (POPs) are a diverse group of organic substances which persist in

38

the environment, bioaccumulate and biomagnify in the food chain, are toxic, and prone to long-

39

range atmospheric transport.1-4 Several families of POPs have been regulated by the Stockholm

40

convention aiming at reducing or eliminating their production and use.5 Polychlorinated

41

dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF), commonly known as

42

dioxins, are among the most toxic POPs listed in the Stockholm Convention.6,7Some

43

polychlorinated biphenyls (PCB), also included in the Stockholm Convention, have similar

44

toxic properties to dioxins due to their similar structure and planarity, and are known as dioxin

45

like PCB (dl-PCB). While PCDD/F are ubiquitous contaminants released into the environment

46

as unintentional byproducts of chemical manufacturing and incineration processes,8-10 PCB were

47

produced on purpose since 1929 during several decades for diverse industrial activities till they

48

were generally banned over 30 years ago.11,12Although the use of PCBs is banned and PCDD/F

49

emissions have been reduced during the last decade,13-16 their persistence and potential for long-

50

range atmospheric transport (LRAT) account for the presence of PCDD/F and dl-PCB in remote

51

locations away from source regions.12,17-24 The PCDD/F and dl-PCB occurrence in background

52

terrestrial locations is widely documented,25-29however, there is a dearth of assessments forthe

53

marine environment. Previous studies have reported on the atmospheric PCDD/F occurrence in

54

coastal areas,30-32 and oceanic islands.33 To the best of our knowledge, only one study reported

55

on dioxins in the open Mediterranean Sea atmosphere, 34 and there are only two previous studies

56

on the dioxin atmospheric occurrence and fate in Atlantic Ocean north-south transects.16,35

57

Therefore, the occurrence of PCDD/F and dl-PCBs in the global oceanic atmosphere needs to be

58

comprehensively assessed in order to determine the background levels in the planetary

59

atmospheric boundary layer, and better understand the major drivers of the LRAT of dioxins.

60

The LRAT of semivolatile and hydrophobic POPs is affected by a number of processes, notably

61

degradation with OH radicals and atmospheric deposition.36 It is well accepted that oceanic

62

biogeochemical processes, such as the biological pump, play a critical role in controlling the

63

diffusive air-water exchange of PCBs and presumably dioxins.37-40However, most PCDD/Fs are

64

found mainly associated to the aerosol phase and thus are deposited to the ocean by dry and wet

65

deposition.34,41The aims of this study are: i) to assess for the first time the global atmospheric

66

background occurrence of gas- and aerosol-phase PCDD/F and dl-PCB in the Pacific, Indian

2 ACS Paragon Plus Environment

Page 3 of 26

Environmental Science & Technology

67

and Atlantic Oceans, ii) investigate on potential drivers of their LRAT, iii) estimate the

68

atmospheric dry deposition of PCDD/F to the ocean.

69

Materials and methods

70

Sample collection

71

High volume air samples were collected onboard the R/V Hespérides during the Malaspina

72

oceanographic circumnavigation campaign from December 2010 to July 2011. A total of thirty

73

nine air samples were collected from the tropical and subtropical oceans between 40oN and

74

35oS: 17 samples from the Atlantic Ocean, 8 from the Indian Ocean and 14 from the Pacific

75

Ocean. Sample locations are shown in Figure 1. The aerosol and gas phases were sampled

76

separately on quartz fiber filter (QFF) and polyurethane foams (PUF), respectively, using high

77

volume air samplers (MCV, Collbató, Spain) placed above the bridge deck (15m above sea

78

level).The sampled air volumes varied from 600 to 1300 m3. Wind direction was taken into

79

account in order to avoid ship contamination (exhausts fumes from the chimney) with a vane

80

which turned on the samplers when the relative wind direction was between 0º and 180º from

81

the direction of the ship (ship emissions located at 270º). PUFs and QFFs were kept wrapped in

82

aluminum foil and in two zip bags and stored frozen at -20ºCuntil their analysis in the

83

laboratory.

84

Chemical analysis

85

Gas and aerosol phase were separately analyzed from 19 atmospheric samples, while only the

86

gas phase was processed from the remaining 20 samples. Prior to extraction, samples were

87

spiked with known amounts of the surrogate mixtures 13C12 PCDD/F (EN-1948-ES, Wellington

88

Labs., Guelph, Canada) and 13C12 dl-PCB (P48-W-ES LCS, Wellington Labs., Guelph, Canada).

89

Two h after spiking, the samples were Soxhlet extracted for ~24 h using 800 mL of toluene as

90

solvent. The organic extract was concentrated in a rotary evaporator and then transferred to n-

91

hexane. The clean-up and fractionation process was based on the sequential use of open

92

chromatographic multilayer silica, basic alumina and carbon columns. The first column of

93

multi-layer silica (top: 12 g acid silica modified with 44% sulphuric acid; bottom: 6 g basic

94

silica modified with 33% sodium hydroxide) was followed by an alumina column. Columns in

95

tandem were pre-eluted with 100 ml of n-hexane. After adding 90 mL n-hexane (Fraction 1) in

96

the tandem, multilayer silica column was removed and samples were eluted from the alumina

97

column with 75 mL of hexane:dichloromethane (9:1) (Fraction 2) containing dl-PCB and 120

98

mL of hexane:dichloromethane (1:1) (Fraction 3) containing PCDD/F. Fraction 3 was purified

99

using a carbon column (Carbopack C 80/100 at 18% with Celite 545), and dioxins were eluted

100

with 75 mL of toluene. The extracts were rotary concentrated, reduced to dryness by a gentle

3 ACS Paragon Plus Environment

Environmental Science & Technology

101 102

stream of nitrogen and reconstructed in a known amount of mixtures of 1948-IS, Wellington Labs., Guelph, Canada) and

Page 4 of 26

13

C12 PCDD/F (EN-

13

C12-dl-PCB (P48-RS, Wellington Labs.,

13

103

Guelph, Canada) used as internal standards ( C12 PCDD/F and dl-PCB added, listed in table S).

104

Finally, high resolution gas chromatography coupled to high resolution mass spectrometry

105

(HRGC-HRMS) was used for instrumental analysis. All analysis were performed on a Trace GC

106

ultra gas chromatograph (Thermo Fisher Scientific, Milan, IT) fitted with a 60m x 0.25 mm i.d.

107

x 0.25 µm film thickness DB-5ms fused silica column for PCDD/F and a 60m x 0.25 mm i.d. x

108

0.25 µm film thickness DB-XLB fused silica column for dl-PCB coupled to a high resolution

109

mass spectrometer (DFS, Thermo Fisher Scientific) with a Xcalibur data acquisition system.

110

The HRGC-HRMS was used with a positive electron ionization (EI+) source operating in the

111

multiple ion detection (MID) mode at 10.000 resolution (10% valley definition). Quantification

112

was carried out by isotopic dilution method, a common method in mass spectrometry42-45 and

113

extensively detailed in well accepted method such EPA 1613.46

114

Quality assurance and quality control (QA/QC)

115

All material employed for the sampling was rigorously cleaned and properly stored before the

116

sampling cruise. All sampling devices were also rinsed with acetone after and before sampling

117

to avoid potential contamination between different samples. Laboratory blanks covering the

118

whole methodology and field blanks, which include the transport and the storage during the

119

oceanographic campaign, were performed in parallel to the field samples. Expectedly, field

120

blanks presented slightly higher levels in comparison to those achieved for laboratory blanks,

121

especially for dl-PCB congeners. In most cases, analyte’s concentration in the blanks(field and

122

laboratory blanks) were below LOD, and only 5 over the 17 analyzed PCDD/Fs congeners were

123

detected in some blanks, corresponding to trace amounts of octa- and hepta- chlorinated dioxins

124

and furans (see Annex II for details).For the 5 dioxins detected in blanks, the levels in samples

125

were above the blank levels for 93 % of the samples PCB#118, PCB#105 and PCB#156 were

126

also detected in the blank samples. The levels of the few detected PCDD/Fs congeners in blanks

127

were considerably lower than the mean levels found in the oceanic samples. Blank

128

concentrations were around 25% of sample mean PCDD/F concentrations. Blank concentrations

129

were around 12% of the mean samples dl-PCB concentrations. Therefore, there is a lack of

130

contamination during handling, storage and analysis for most of the compounds and samples.

131

Sample congener concentrations below mean blank congener were considered below detection

132

limit and not reported. For dl-PCB, this affected mainly the aerosol phase samples due to the

133

low levels in this matrix. Individual LODs achieved for all samples are provided as Supporting

134

Information in TablesS2a and S2b.The overall reliability of the analytical procedure was

135

assured by using labeled compounds in each sample to identify unequivocally the different

4 ACS Paragon Plus Environment

Page 5 of 26

Environmental Science & Technology

136

congeners and also obtain the surrogate recoveries (TablesS2c and S2d of Supporting

137

Information) which had a median recovery value of 92%. All the samples satisfied the minimum

138

requirements described in well accepted methods such as UNE-EN 1948 or EPA 1613.46,47 The

139

efficiency of the method was also checked by analyzing certified reference materials (CRM) for

140

PCDD/F and internal reference materials for dl-PCBs. Complementary, the laboratory is in

141

continuous participation with inter-laboratory studies to ensure the quality of the protocols

142

used.48,49

143 144

Results and discussion

145

Occurrence of PCDD/F in the global oceanic atmosphere

146

Figures 1 and 2 show the global distribution of PCDD/Fs, and Table S3a summarizes the

147

PCDD/F congener specific mean and range of concentrations, and toxic equivalents, in both the

148

gas and aerosol phases for all the oceans. Figure 3 shows the characteristic patterns of

149

PCDD/Fs. In the gas phase, concentrations ranged between 1 and 27 fg/m3 for ∑PCDFs, and

150

between 3 and 41 fg/m3 for ∑PCDDs. The toxic equivalent of ∑PCDD/Fs was between 0.1 and

151

7.2 fg I-TEQ/m3. Octachlorodibenzo-p-dioxin (OCDD) was the most abundant congener, and it

152

was detected in all, except one, of the analyzed samples. The highest concentration of OCDD

153

was found in the North Pacific with gas phase concentrations reaching 25 fg/m3. The maximum

154

OCDD concentration for the North Atlantic was 13 fg/m3 (Table S3a), consistent with the

155

concentration of10.6fg/m3reported at Barbados in 1999,33 but one order of magnitude lower

156

than the maximum OCDD found at the same latitudes in 1998 (230fg/m3).35It is possible that

157

PCDD/F concentrations over the open ocean have decreased by more than one order of

158

magnitude during the last decade due to reduced emissions in source regions as suggested

159

previously.16The lowest concentration of PCDD/Fs was measured for TCDD in the South

160

Atlantic (0.1 fg/m3). TCDD and pentachloro dibenzo-p-dioxin (PCDD) could only be quantified

161

in 31% of the analyzed gas phase samples due to levels below detection limits.

162

In the aerosol phase, the concentration varied from 2 to 21 fg/m3 for ∑PCDFs and from 3 to 92

163

fg/m3 for ∑PCDDs fg/m3, while the toxic equivalent was between 0.3 and 5.6 fg I-TEQ/m3.

164

Three congeners were detected in almost all of the aerosol phase samples: OCDD,

165

Heptachlorodibenzo-p-dioxin (HpCDD) and 1,2,3,4,6,7,8-heptachlorodibenzofuran (HpCDF).

166

The highest concentration for OCDD was reported in the South Atlantic (64 fg/m3), with a mean

167

concentration for the global ocean of 14 fg/m3. This is comparable with the aerosol phase

168

concentrations of 8.4fg/m3 reported at Barbados.33These concentrations were 2 orders of

169

magnitude lower than those reported previously, with values as high as 210fg/m3 for OCDD for

5 ACS Paragon Plus Environment

Environmental Science & Technology

Page 6 of 26

170

samples taken in 1998.35 Tetrachlorinated dibenzofuran (TCDF) and tetrachlorinated dibenzo-p-

171

dioxin (TCDD) could only be detected in 20% of the aerosol phase samples; their

172

concentrations were generally low, with a minimum concentration range of 0.2-0.6 fg/m3 for

173

TCDD, and 0.3-0.8 fg/m3for TCDF.

174

The global background atmospheric concentration (gas + aerosol phase) of ∑PCDD/Fs over the

175

ocean is of 43fg/m3, or 3.8 fg I-TEQ/m3, and these varied from 15 to 126 fg/m3 for ∑PCDD/Fs,

176

and from 1to 10fg I-TEQ/m3. There are only few studies reporting the atmospheric

177

concentrations of ∑PCDD/Fs over the ocean, and these only cover the Atlantic Ocean16,35and

178

the Mediterranean Sea.34Mean, median and range of ∑PCDD/Fs(gas + aerosol phase) in

179

Atlantic Ocean studies were collected in the table S3i from the Supporting Information.

180

Malaspina concentrations were comparable to those measured in Nizzetto et al. (2008),16 but

181

one order of magnitude higher than those measured in 1998.35The ∑PCDD/Fs levels reported

182

here are one order of magnitude lower than those described for the open Mediterranean Sea in

183

2006-2007 (60-1040fg/m3),34 which is highly influenced by the proximate highly populated

184

regions. Therefore, it is possible that there has been a decrease of concentrations of PCDD/F

185

during the late 90’s15 and the following decade, but that this decreasing trend has been stopped.

186

This could be consistent with a lack of further decrease in the primary sources of PCDD/Fs, and

187

that secondary sources of PCDD/Fs are becoming increasingly important buffering the decrease

188

of PCDD/Fs. Time trends of PCDD/F in the Baltic Sea, thus close to primary sources, also show

189

a lack of significant decrease during the last years.50

190

The pattern of PCDD/F in the gas and aerosol phase (Figure 3) showed profiles consistent with

191

those reported for rural and remote areas28,32,51-53 for most of the samples. In the particular case

192

of samples affected by air masses coming from proximate land (samples 120, 121, 41), a

193

slightly different pattern was observed with a lower OCDD contribution to the total

194

concentration contribution. Classical anthropogenic sources.54,55use to have a profile without

195

OCDD levels standing out so much above the rest in contrast with those reported for rural areas

196

with a major OCDD contribution to the total concentration. These samples also showed a higher

197

contribution of the less chlorinated congeners, which are degraded by OH radicals during

198

atmospheric transport. As expected, the aerosol phase is enriched with the most hydrophobic

199

congeners such as those having 7-8 Chlorines. 1,2,3,7,8,9-Hexachlorodibenzofuran presented

200

the highest percentages in the aerosol phase (average of 90%). Otherwise, tetrachlorinated

201

dioxins and furans were predominantly found in the gas phase, with an average of 80% for

202

TCDF. The overall levels of ∑PCDD/F were similar for the gas and aerosol phases, except in

203

some regions such as off the coast of Brazil, where the aerosol phase concentrations were the

204

highest (see below for a discussion on air-mass back trajectories).

6 ACS Paragon Plus Environment

Page 7 of 26

Environmental Science & Technology

205 206

Occurrence of dl-PCB in the global oceanic atmosphere

207

Figure 4 shows the global distribution of dl-PCBs, and Table S3b summarizes the mean and

208

range of the concentrations for each one of the 12 dl-PCB congeners. Most of the dl-PCB were

209

detected in all the gas phase samples. ∑dl-PCB concentrations in the gas phase ranged from 385

210

to 9227 fg/m3. Expressed as TEQ units, concentrations were between 0.1 and 8.4 fg WHO-

211

TEQ2005/m3. PCB118 was the most abundant congener, with a maximum concentration of 3330

212

fg/m3, followed by PCB105, PCB156, PCB77 and PCB156. Conversely, PCB81 was detected

213

only in 23% of the analyzed gas phase samples. The lowest concentration was obtained for

214

PCB169, 1fg/m3 in a gas phase sample from the South Pacific.

215

As expected, the concentrations of dl-PCB were significantly lower in the aerosol-phase than in

216

the gas phase consistent with other reports of PCBs in the oceanic atmosphere.40,56,57Theaerosol

217

phase concentrations of ∑dl-PCB ranged from 1 to 2675 fg/m3, while their associated TEQ

218

values varied between 0.01 and 4.5 fg WHO-TEQ2005/m3.Similarly to the gas phase, the most

219

abundant PCB congeners were PCB#118, PCB#105 and PCB#156, while PCB#81 was the less

220

abundant, only detected in 15% of the aerosol phase samples, followed by PCB#126 and

221

PCB#114 which were detected in less than 25% of the samples. The highest aerosol phase

222

concentrations of dl-PCBs were found in the South Atlantic Ocean close to the Brazilian coast,

223

and in the south Western Indian Ocean close to South Africa (Figure 4).

224

The profiles of dl-PCB in both the gas and aerosol phase do not vary significantly for the

225

different oceanic regions, and the congener distribution is similar to those reported in the

226

literature for the continental/coastal atmosphere32,51-53 being the PCB#118 the predominant,

227

followed by PCB#105 and PCB#156 (Figure 3). To the best of our knowledge, this is the first

228

coherent data set on the atmospheric oceanic occurrence of dl-PCB, with the exception of a

229

report for the Mediterranean Sea atmosphere.56 Previous efforts35on dl-PCB occurrence in

230

oceanic atmosphere were affected by ship contamination58. Only PCB#118 (commonly reported

231

as ICES PCB as well as dl-PCB)has a notable body of literature on their occurrence in the

232

tropical-subtropical oceans since ICES PCB were reported in some oceanic studies.59-63The

233

mean atmospheric concentrations (gas + aerosol) of PCB#118 are similar but in the lower range

234

than those reported previously (See Table S3j for the comparison).

235 236

Influence of air mass back trajectories on PCDD/F and dl-PCB occurrence

7 ACS Paragon Plus Environment

Environmental Science & Technology

Page 8 of 26

237

There is a notable variability of the atmospheric concentrations of both PCDD/F and dl-PCB

238

globally (Figures 1, 2 and 4). Concentrations in the Pacific Ocean lie generally in the low-end of

239

the global background levels, except for the samples south west of California (USA), Mexico

240

and Central America. The variability in concentrations is higher in the other oceanic regions.

241

Significant differences between oceans can be stated if we compare the more abundant

242

congeners from samples from the different oceans (excluding those influenced by land-based air

243

masses). In general, South Pacific Ocean has the lower PCDD/F concentrations while North

244

Atlantic has the higher dl-PCB concentrations. The higher concentrations East of Brazil, close

245

to South Africa, Australia and off West Africa (Figures 1, 2 and 4) suggest that the air-mass

246

back-trajectories (BTs) could influence the observed spatial patterns by driving higher

247

concentrations in areas influenced by adjacent source regions. The BTs were obtained from the

248

Hysplit model from Air Resources Laboratory of the National Oceanic and Atmospheric

249

Administration (NOAA).64The sample specific BTs during the Malaspina circumnavigation

250

cruise reflect the general oceanic pattern of a clock-wise subtropical gyre in the north Atlantic

251

and north Pacific, and counter-clock wise gyre in the Southern Atlantic, Pacific and Indian

252

oceans (Figure S1b). In the Northern Atlantic, the ship traversed the trade winds (from ~30ºN to

253

near the inter-tropical convergence zone, ITCZ) with winds coming from the northeast (samples

254

4 and 11) or the East-north East(samples126-142). Samples 4 and 11 (NE Atlantic) show high

255

concentrations of dl-PCBs, and to less extent PCDD/F. This is consistent with the high

256

concentrations of PCBs, and other pollutants, described for this region reflecting inputs from

257

source regions in North West Africa and South Eastern Europe.59,60,62 In the rest of the samples

258

from the north Atlantic (samples 126-142), the levels of dl-PCB and PCDD/F are low for those

259

located in the north Atlantic subtropical gyre, while higher levels are observed in the Caribbean

260

due to proximate land or coastal seawater as sources. In the North Pacific, levels are generally

261

low due to BT showing that the air mass had travelled over the ocean for several days (samples

262

92-120), except some sampling events showing higher concentrations of PCDD/F, which are

263

affected by air mass BT originating in Mexico and central America, especially in sample 121,

264

but also other samples in this region (samples 121-125).

265

Other samples with high PCDD/F concentrations in the gas phase were sample 41, and samples

266

41 and 46 for the aerosol phase, with air masses coming from south of Cape of Good Hope

267

(South Africa), thus reflecting the influence of proximate land. For the aerosol phase, the

268

highest concentrations of PCDD/F and dl-PCB were achieved in samples taken off-shore the

269

Brazilian coast (samples 23 and 24). High levels of polycyclic aromatic hydrocarbons have also

270

been described for these samples.6 The BT for the lower atmosphere show an oceanic influence

271

(from the East); however, the air masses for the upper boundary layer (800-100 m height) show

272

an influence from the proximate Brazilian coast. Therefore, it is possible that the aerosol phase

8 ACS Paragon Plus Environment

Page 9 of 26

Environmental Science & Technology

273

concentration of PCDD/F and dl-PCB is affected by aerosol particles deposited from this upper

274

air mass. This would also explain the fact that such an increase is not observed for the gas phase

275

PCDD/F and dl-PCB concentrations of-shore Brazil.

276

In the southern hemisphere and in the open ocean, the ship crossed regions with trade winds

277

from the southeast (samples 16-35, 58-63, 81-88). Between 30 and 35 degrees south, there are

278

the subtropical highs, a region under a ridge pressure which has variable winds mixed with calm

279

periods (samples 39-51, 67-71) (Figure S1bBTs graphics in the Supporting Information). At

280

Open Ocean, the PCDD/F and dl-PCB concentrations in the gas and aerosol phases are

281

generally low reflecting the oceanic origin of the BT for the few days before the sampling event.

282

Exceptionally, in some cases it is not possible to justify from the BT for the low atmospheric

283

boundary layer the unexpected relative higher levels for PCDD/F such as in sample from Indian

284

Ocean. The BT in the upper boundary layer are more variable, with episodes of air masses

285

coming from the NE65and particles may have reached the lower boundary layer by deposition.

286

In addition, there is presumably a volatilization of PCDD/F and PCBs in this region, enhanced

287

by the high wind speeds during and before these sampling events. Volatilization of PCBs has

288

been described for the oligotrophic oceanic gyres.16,61Therefore, regarding the influence of BT

289

on the global distribution of dl-PCB, the different patterns between the gas and aerosol

290

phasesare remarkable (Figure3). In the gas phase, the Atlantic Ocean had the highest values of

291

dl-PCB and a decreasing tendency from North to South is observed as a reflection of historic

292

emissions impact and the influence of emissions from SW Europe and NW Africa. The Pacific

293

and Indian Oceans presented generally the lowest dl-PCB levels except for 2 samples previously

294

discussed. Besides, the aerosol phase levels are also generally low (background) with the

295

exception of the commented influence of Brazil and South Africa on the proximity of the

296

sampling sites which are influenced by BT in the lower and at the upper levels of the boundary

297

layers.

298 299

Atmospheric deposition and degradation affecting the background occurrence of PCDDF/

300

and dl-PCBs

301

The background oceanic concentrations of PCDD/F reported here are not only among the lowest

302

ever reported in the literature consistent with the remoteness of the studied regions, but the first

303

PCDD/F data for large regions of the world ocean. During atmospheric transport, PCDD/F and

304

dl-PCB will be subject to a number of removal processes, basically atmospheric deposition and

305

OH degradation. Diffusive air-water exchange is usually considered the main atmospheric

306

deposition process for PCBs, but not for most dioxins.20,34,37-41 However, because PCDD/Fs and

9 ACS Paragon Plus Environment

Environmental Science & Technology

Page 10 of 26

307

dl-PCBs were not measured in the dissolved phase, the magnitude and direction of this process

308

cannot be elucidated here. Nevertheless, Jurado et al. have estimated that for most PCDD/Fs,

309

atmospheric dry deposition is the main depositional process for the open ocean,38,41 and Castro-

310

Jiménez and collaborators have reached the same conclusions from measurements performed in

311

the Mediterranean Sea.34 The dry aerosol deposition fluxes (FDD, pg/m2d) can be estimated from

312

the measured aerosol phase concentrations by

313

[1]

314

Where vD is the overall aerosol dry deposition velocity (cms-1), and Cp is the concentration of

315

the compound in the aerosol phase (pg/m3).33,66 During the Malaspina Cruise, the dry deposition

316

fluxes of PAHs were measured and an empirical parameterization has been suggested to predict

317

the vD values of semivolatile organic compounds at the open ocean,65

318

(2)

319

Where U10 is the wind speed at 10m above sea level (m s-1), Chls is the surface chlorophyll

320

concentration (mg m-3), and PL is the compound’s vapor pressure (Pa), which was calculated as

321

suggested elsewhere.67 The vD values for PCDD/F and dl-PCB during the Malaspina cruise

322

ranged from 0.01 to0.2 cms-1, which is of the same order of magnitude than those estimated

323

from models(0.05 to 0.5 cms-1) by Jurado et al.38 The uncertainty associated to the estimation of

324

vD by equation 2 is of a factor of 3 (335%) as estimated by Gonzalez-Gaya et al.(2014).65

325

Dry deposition fluxes of PCDD/F and dl-PCBs to the global oceans show a large geographical

326

variability depending on aerosol size distribution, atmospheric turbulence and atmospheric

327

stability.38 Figure 5 shows the average dry deposition fluxes of PCDD/F and dl-PCBs for the

328

different oceanic basins. The dry deposition fluxes of PCDD/F are lower than those reported for

329

the Mediterranean Sea, a difference driven by the lower PCDD/F concentrations in the open

330

ocean, and the lower vD values in this study. The Atlantic and Pacific Oceans receive most of

331

the dry deposition input of PCDD/F to the global ocean, 130 and 170 kg/yr respectively, while

332

60 Kg PCDD/F/yr were estimated for the Indian Ocean. Overall, the integrated dry deposition

333

flux of ∑PCDD/F to the global oceans is of 360 Kg/yr. This figure is significantly lower than

334

the 2400 Kg /yr estimated previously,68 but which was based from the higher PCDD/F

335

concentrations measured in 1998.35

336

As expected, mean dry aerosol deposition fluxes for dl-PCB for the oceans (Figure5) were

337

considerably higher than PCDD/F deposition fluxes. Atlantic Ocean received the highest input

338

with more 630 Kg of dl-PCB per year accounting up to 70% of the total dry dl-PCB deposition.

339

Secondly, 190 Kg/yr were estimated for Indian Ocean followed by Pacific Ocean with only 80

10 ACS Paragon Plus Environment

Page 11 of 26

Environmental Science & Technology

340

Kg/yr. The total dry aerosol deposition of ∑dl-PCB to the main oceans is estimated to be 900

341

Kg/yr. It is likely that this represents a small fraction of the dl-PCBs exchange between the

342

atmosphere and ocean, because diffusive exchange may be one order of magnitude higher than

343

dry deposition in the case of PCBs.

344

It has been suggested that atmospheric degradation, due to reaction with OH radicals, is the

345

main removal mechanism of dioxins from the atmosphere.68 This removal process will affect

346

mainly the PCDD/F found in the gas phase. The reaction rate constants of PCDD/F with OH

347

radicals are higher for the less chlorinated congeners, and are significantly higher for PCDD

348

than for PCDFs.68-70 Therefore, the comparison of the ratio TCDF/TCDD in the gas-phase could

349

provide information on whether this loss process induces a change in the pattern of PCDD/F by

350

removing some congeners faster than others during atmospheric transport. Figure 6 shows the

351

TCDF/TCDD ratio, together with the BTs during the sampling period for all samples in which

352

both compounds were detected (11 samples out of the 39 analyzed gas phase samples). A

353

remarkable finding is that samples affected by oceanic air masses are quite different from those

354

with air masses coming from land or marine coastal regions. The TCDF/TCDD ratio in samples

355

from oceanic air masses presented higher values of TCDF/TCDD (>1) than the samples affected

356

by land air masses (