BEL-ART PRODUCTS PEQUANNOCK

Write or phone for complete details. new! from... BEL-ART. DISPOSABLE. CHROMATOGRAPHIC. TUBES. These disposable polypropylene chromatographic tubes, o...
1 downloads 10 Views 214KB Size
imew!

Flash! And you've got a sample of an "intractable" in 3 minutes !

from...

B E L - A R T DISPOSABLE

CHROMATOGRAPHIC TUBES

NEW BARNES P Y - 2 PYROLYZER SAVES HOURS IN PREPARATION TIME If you're using slow, old-fashioned test tube methods to obtain readable sam­ ples of tough-to-analyze materials like carbon-filled rubbers and some plastics -here's a brand new time-saver for you. Generally, burning in a test tube, or dissolving a stubborn sample, takes at least 45 minutes . . . often more. The new Barnes PY-2 Pyrolyzer will do the job for you in three minutes. Here's all you do: Put a snippet of material-or a micro-spoonful of pow­ der, if that's what you're sampling-on the heating unit in the Pyrolyzer's va­ porizing chamber. Seal the chamber. Set a timer. Select your temperature. New Barnes

PY-2 Pyrolyzer,

Evacuate the chamber automatically. And flash! Your sample is volatilized and ready for analysis. In 3 minutes, instead of 45 or more, you're running a spectrum. Heat range on the new PY-2: variable to 1250°C. Timing range: from 1 to 15 seconds, or bypass the timer. Power: 115 VAC 60 cycles. Three kinds of pyrolysis chambers are available: Transmission conden­ sate cell, ATR condensate cell, trans­ mission vapor cell and holder. If you want to get more done in busy days . . . save time with the new Barnes PY-2 Pyrolyzer. Write or phone for complete details. showing

types of pyrolysis

chambers

available.

These disposable polypropylene chromatographic tubes, or columns, are excellent for all types of qualita­ tive, semi-qualitative and many quanti­ tative analyses. The pore size of the support disc is 1/64" diameter. The columns may be used for continuous flow processes with or without fraction collector as shown.

Tube is 5 / 8 " I.D. χ 6" long and holds 30 ml; fittings ac­ cept 1/4" to 3 / 8 " I.D. tub­ ing. Replacement columns are available separately with­ out end fittings. No need to buy additional end fittings.

Special plastic clamp is available to hold tube verti­ cal on support rod. Available at your local laboratory supply house. Send for our catalog supplement listing many NEW items . . . just off tfie press! For your FREE copy write Dept. A-2

BARNES ENGINEERING COMPANY INSTRUMENT

DIVISION/30

Commerce

Rd. /Stamford,

Circle No. 81 on Readers' Service Card

182 A

.

ANALYTICAL CHEMISTRY

Conn. / Telephone

BEL-ART PRODUCTS PEQUANNOCK, N . J . 0 7 4 4 0

203 348-5381 Circle No. 86 on Readers' Service Card