Carbon and Phosphorus Removal from Primary Municipal Wastewater

Oct 13, 2017 - In this work, recovery of aluminum from coagulated primary sludge and its reuse potential as secondary coagulant were investigated. The...
2 downloads 9 Views 852KB Size
Subscriber access provided by UNIV OF TEXAS ARLINGTON

Article

Carbon and phosphorous removal from primary municipal wastewater sludge using recovered aluminum Tulip Chakraborty, Michelle Gabriel, Ali Amiri, Domenico Santoro, John Walton, D. Scott Smith, Madhumita B. Ray, and George Nakhla Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b03405 • Publication Date (Web): 13 Oct 2017 Downloaded from http://pubs.acs.org on October 16, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 28

Environmental Science & Technology

1

Carbon and phosphorous removal from primary

2

municipal

3

aluminum

wastewater

sludge

using

recovered

4

Tulip Chakrabortya, Michelle Gabrielb, Ali Safarzadeh Amirib, Domenico Santoroa,b, John

5

Waltonc, Scott Smithd, Madhumita Raya*, George Nakhlaa*. a

6

- Department of Chemical and Biochemical Engineering. University of Western Ontario,

7

London, Ontario, Canada. b

8

- Trojan Technologies, London, Ontario, Canada. c

9 10

d

- USP Technologies, Atlanta, Georgia, USA.

- Department of Chemistry and Biochemistry, Wilfrid Laurier University, Waterloo, Ontario,

11

Canada.

12 13

KEYWORDS: chemically enhanced primary treatment, coagulant recovery, phosphorous

14

removal, primary sludge.

15

ACS Paragon Plus Environment

1

Environmental Science & Technology

Page 2 of 28

16

ABSTRACT: In this work, recovery of aluminum from coagulated primary sludge and its reuse

17

potential as secondary coagulant were investigated. The recovery process consisted of releasing

18

the particle-bounded aluminum from primary sludge by acidification (HCl or H2SO4), followed

19

by separation using centrifugation for dissolved coagulant recovery. The recovered coagulant

20

was then reused for treating primary wastewater and overall coagulation efficiency was

21

determined. While with fresh alum, the removal efficiencies of total suspended solids, chemical

22

oxygen demand, total phosphorous, and total nitrogen were 85%, 65%, 80% and 33%,

23

respectively, a drop in removal efficiency of total suspended solids and chemical oxygen demand

24

was observed for recovered aluminum (85% to 60% and 65% to 50%, respectively). Nitrogen

25

concentration remained almost constant with each cycle, while phosphorous in the effluent

26

increased by 1 mg/L and 3 mg/L in the first and second cycle, respectively. Precipitation of

27

various aluminum species was modelled for determining the recovery potential of aluminum at

28

low pH. Preliminary cost analysis indicates that optimum recovery of aluminum occurred at a pH

29

of 1.5 for both acids. Struvite precipitation effectively removed increased phosphorus solubilized

30

by acidification at the end of second cycle, however, it also decreased the amount of aluminum

31

available for recycle.

32

33

34

GRAPHICAL ABSTRACT

ACS Paragon Plus Environment

2

Page 3 of 28

Environmental Science & Technology

35

36

1. Introduction

37

The worldwide production of municipal wastewater exceeds 330 billion m3 per annum [1,2,3].

38

As municipal wastewater treatment plants focus on resource recovery and energy efficiency,

39

chemically enhanced primary treatment (CEPT) is re-gaining importance due to its enhanced

40

removal of organics, thus simultaneously increasing biogas production while reducing aeration

41

energy and excess biological sludge production. The added coagulant in the CEPT process

42

generates significant amounts of chemical sludge contributing up to 5% - 20% of the total solids

43

with ferric coagulant and 15% - 40% with alum [4,5,6]. Thus, treating these solids or sludge to

44

recover coagulants not only offsets the cost of disposal by decreasing chemical sludge volume

45

but also the cost of dosing fresh coagulant in wastewater [7,8,9]. Different separation techniques

46

such as acidification, basification, ion exchange and membrane processes have been tested to

47

separate various coagulants from sludge [8]. While membrane processes (pressure filtration

48

membranes) have been tested in purification of the recovered coagulant [10,11], their inability to

49

adequately remove dissolved contaminants, coupled with membrane fouling is a significant

50

limitation. Precipitation due to basification has shown recovery of aluminate salts at a pH of 11.4

51

[12], however, the cost of sodium hydroxide, twice that of sulphuric acid coupled with recovery

52

at high concentrations (950 mg/L Al) makes it a challenging process [13]. While other alternate

53

base such as calcium hydroxide (cheaper than sodium hydroxide) was used, only 50% recovery

54

of aluminum at a pH of 11.4 was possible due to the lower solubility of calcium salts compared

55

to aluminate salts [14]. Ion-exchange processes require organic solvents for regeneration and

ACS Paragon Plus Environment

3

Environmental Science & Technology

Page 4 of 28

56

their marginal cost benefit for low value coagulants make them unfavourable [13]. The most

57

efficient and cost-effective method to recover coagulant from the chemical sludge has been

58

found to be acidification, which involves neutralizing the flocs of hydroxide precipitant to

59

release the coagulant salt into solution [15,16,17]. The reused coagulant was able to remove

60

turbidity, chemical oxygen demand (COD), total suspended solids (TSS), and total nitrogen (TN)

61

from wastewater [18,19,20,5,6]. Unfortunately, acidification is not selective and at low pH other

62

contaminants such as organic matter, metals, nitrogen, and phosphorous can also be dissolved

63

[15,8].

64

Previous studies have focussed on coagulant recovery and their reuse in drinking water

65

treatment [21,22]. However, dosing recycled coagulants into the drinking water process resulted

66

in higher levels of disinfection by- products (DBP) formation due to higher dissolved organic

67

carbon (DOC) at the final chlorination step. Hence, in the case of drinking water applications it is

68

not advisable to use the recovered coagulant directly without subjecting the coagulant to further

69

purification.

70

Addition of the coagulated sludge without any further processing was evaluated on various

71

types of waste streams. Chu [23] demonstrated the use of recycled alum sludge as a coagulant to

72

remove dyes from textile dying wastewater. While the recycled sludge reduced the hydrophobic

73

dye, addition of fresh coagulant to supplement the recycled coagulant was necessary to remove

74

hydrophilic dye, which was detrimental for the recycled water quality.

75

Published research on aluminum recovery from biosolids (generated from primary wastewater

76

treatment) is limited [8,17,24] mostly due to the complex nature of wastewater as compared to

77

drinking water and other effluents. While Xu et al [8] and Ishikawa et al [17] focussed on

78

aluminum recovery from wastewater and clarifier sludge, they did not elucidate the effect of

ACS Paragon Plus Environment

4

Page 5 of 28

Environmental Science & Technology

79

organics on subsequent cycles due to coagulant recovery. Jiménez et al [24] investigated the

80

secondary sludge stabilization with sulphuric acid and the effects on various mixing aspects

81

while focussing on inactivation of microorganisms. These studies mainly focussed on the

82

recovery of coagulants and did not investigate the effect of the recycled coagulant on other water

83

quality parameters such as dissolved organics and nutrients. Therefore, the main objective of this

84

study was to assess the impact of recycled aluminum on the removal efficiency of the various

85

water quality parameters like total phosphorous (TP), soluble phosphorous (sP), COD, soluble

86

chemical oxygen demand (sCOD), TSS and TN and to address the organic loading. The optimum

87

acidification pH for the maximum recovery of alum coagulant was established, and the impact of

88

recycled aluminum on the fractionation of additional organic loading in terms of TSS, TP, sP,

89

COD, sCOD and TN was characterized.

90

[2] Methods and Materials:

91

[2.1] Aluminium sulphate dose optimization

92

The different water quality parameters such as TP, sP, TN, TSS, COD and sCOD of the PI

93

collected from the Pottersburg water pollution control plant (WPCP) located in London, Ontario,

94

Canada were measured. A 10% aluminium sulphate [Al2 (SO4)3.18H2O] stock solution in

95

deionized water was used to treat 1L of PI with a phosphorous: aluminum molar ratio of 1:2.

96

Using a jar test apparatus (Phipps & Bird PB-900), the solution was mixed at a fast rate (100

97

rpm) for 1 minute followed by a slow rate (30 rpm) for 20 minutes. The flocs were allowed to

98

settle for 30 minutes and the effluent was analyzed for TSS, TN, TP and COD.

99

[2.2] Aluminum recovery and reuse:

100

The coagulated water from the jar test was centrifuged at 3500 rpm for 5 min and the sludge

101

was collected. The alum was recovered by acidifying the sludge to a pH of 0.5, 1.5 or 2.5 with

ACS Paragon Plus Environment

5

Environmental Science & Technology

Page 6 of 28

102

concentrated H2SO4 (36N) or HCl (12N). The acidified sludge was mixed using a magnetic

103

stirrer at 170 rpm for 60 min, and then centrifuged at 3700 rpm for 10 min. The supernatant was

104

removed and was analyzed for aluminum concentration using ICP-MS (ICP-OES Vista Pro

105

Axial, Varian, Australia). The recovered aluminum from the supernatant of the centrifuged

106

sludge was then reused to dose a fresh sample of PI and the procedures described above were

107

repeated. There was no significant effect on the pH of PI by the addition of recovered coagulant

108

due to the large difference in volume of the recovered coagulant and PI, decreasing it slightly

109

from 7.1 to 6.9.

110

[2.1.1] Analytical Methods:

111

Solution pH was measured with a digital pH-meter (HACH, HQ11d). COD (method 8000),

112

sCOD (solution filtered through 0.45 µm) (method 8000), TP (method 10209), sP (method

113

10209), TN (method 10242) were measured using HACH methods. TSS was measured

114

according to standard APHA methods (method 2540d) [25]. ICP-MS (ICP OES Vista Pro Axial,

115

Varian, Australia) was used to measure aluminum concentration.

116

[2.1.2] Characterization of sludge:

117

The sludge obtained from the centrifugation of PI dosed with alum was characterized for

118

sludge volume index (SVI). To quantify the amount of residual aluminum (after acidification) in

119

the sludge (denoted henceforth as waste sludge), it was digested with nitric acid for 2 hr and

120

analyzed by ICP-MS.

121

[3] Results and discussions:

122

[3.1] Characteristics of the influent wastewater:

123

PI was collected from the Pottersburg WPCP. The sampling was conducted on heavy rainy as

124

well as bright sunny days; as a result, water quality varied considerably and the average values of

ACS Paragon Plus Environment

6

Page 7 of 28

Environmental Science & Technology

125

TSS, TP, sP, COD, sCOD, TN and pH were 240 ± 87 mg/L, 6 ± 2 mg/L, 2.9 ± 0.64 mg/L, 480 ±

126

37 mg/L, 230 ± 21 mg/L and 7.4 ± 0.5, respectively (Table S1).

127

The phosphorous in the PI was measured and the aluminum-to-phosphorous molar ratio was

128

set to 2:1 for dosing of aluminium sulphate in PI. For data analysis, the TP concentrations in the

129

water were divided into 3 groups: 3.3 – 4.9 mg/L, 5.2 – 6.5 mg/L and 6.9 – 8.2 mg/L. The effects

130

of coagulant dosing on the different water quality parameters i.e. TSS, COD, TN and TP were

131

studied for each phosphorous concentration and are presented in Table 1. The percentage

132

removal of suspended solids in the PI marginally increased (2% - 3%) in the different TP levels

133

(Table 1). The particulate phosphorous (PP) was removed by enmeshment in the solids. COD

134

removal at three different phosphorus concentrations showed no significant difference. Since on

135

an average the soluble COD accounted for 50% of the total COD, removal efficiencies of ~ 65%

136

for total COD are noticeably high when compared to an average of 85% TSS removal. This is

137

possibly due to the removal of sCOD by adsorption on freshly formed aluminum hydroxide [26].

138

Table 1. Removal of TSS, COD, sP, PP due to alum coagulation at different initial total

139

phosphorous concentrations. TP (mg/L)

TSS removal (%)

COD removal (%)

sP removal (%)

PP removal (%)

TN removal (%)

3.3 – 4.9

84 ± 6.4

64 ± 7.2

82 ± 0.64

63 ± 7.1

15 ± 5.8

5.2 – 6.5

86 ± 1.1

64 ± 7.3

82 ± 0.4

68 ± 2.2

25 ± 5.6

6.9 – 8.2

86 ± 1.7

65 ± 2.7

94 ± 0.05

80 ± 0.16

20 ± 2.7

140 141

Table 1 shows increasing removal of phosphorus with higher initial concentrations.

142

Conducting ANOVA analysis (with a 95% confidence level) on particulate and soluble

143

phosphorous, the differences in soluble phosphorous removal efficiencies at different initial TP

ACS Paragon Plus Environment

7

Environmental Science & Technology

Page 8 of 28

144

concentrations were deemed as insignificant and the removal of the particulate fraction as

145

significant. A slight variation in the removal of TN was observed probably due to the varying

146

particulate nitrogen concentrations in the wastewater.

147

After coagulation, the effluent was analyzed for different water quality parameters (aluminum,

148

TP, sP, TN, COD, sCOD and TSS), and was centrifuged to separate the sludge from the effluent.

149

The sludge was then treated with acid for repeated recovery of aluminum (refer to the graphical

150

abstract).

151

[3.2] Aluminum recovery at different pH

152

In this research, concentrated HCl and H2SO4 were used separately to acidify the sludge to pH

153

0.5, 1.5 and 2.5. The recovery of aluminum from the acidified sludge at three different pH values

154

is shown in

155

Figure 1.

156

The recovery of aluminum shown in

157

Figure 1 represents the aluminum present in acidified sludge (obtained from coagulation of PI,

158

and as determined by ICP) and not inclusive of the aluminum present in the effluent and the

159

spent sludge. The total mass balance on aluminum includes its concentration in the effluent (1.4

160

± 0.1%) and the spent sludge (21 ± 3.1%).

ACS Paragon Plus Environment

8

Page 9 of 28

Environmental Science & Technology

161 162

Figure 1. Recovery of aluminum from acidified sludge at different pH

163

It is well-established that at low pH, solubility of metals in water increases [27]. It is also

164

worth mentioning that addition of concentrated acid helped in the reduction of sludge volume

165

considerably. Acidification with both HCl and H2SO4 achieved very similar recoveries as both

166

acid anions, i.e. sulphate and chloride, complex weakly with aluminum. At a pH of 0.5, about 84

167

± 2.2% of the aluminum from the sludge was released using H2SO4, while HCl was able to

168

release about 86 ± 1.3% of the aluminum. At a pH of 1.5, aluminum recovery using H2SO4 and

169

HCl was 77 ± 3.1% and 76 ±3 %, respectively, while at pH 2.5, recovery was only 48 ± 13% and

170

55 ± 7%, respectively. As stated earlier, the addition of acid would not only help in releasing the

171

bound aluminum but also various other metals present in the sludge. The concentrations of

172

released metals from the sludge by acidification with either of the acids (HCl or H2SO4) were

173

measured using ICP-MS (Figure S3).

174

Xu et al [9] reported that while recovering aluminum from the sludge, there is a high

175

possibility of recovering other metals likes iron, magnesium, manganese, copper, which is

176

confirmed in this work. The average concentrations of copper, manganese and iron in the

ACS Paragon Plus Environment

9

Environmental Science & Technology

Page 10 of 28

177

recovered coagulant were 1.2 mg/L, 1.8 mg/L, and 78 mg/L, respectively. The concentrations of

178

heavy metals like arsenic, lead and cadmium was 0.1 mg/L, 0.7 mg/L, and 0.05 mg/L,

179

respectively. Although there was a minor accumulation of the heavy metals, there was no

180

significant increase (