routine analysis for highly complex mixtures. A separate quantitative determination of all components can often be made —whether they be hydrocarbons, inorganic gases, oxygenated or other organic derivatives.
you can do
control analysis
for specific components in plant control operations. When analyzing feed or product streams either completely or for key components, the factors of speed and accuracy are more than adequately provided by this instrument.
these
*7Ae Omptowed BARNSTEAD BANTAM The Convenient Water Demineralizer for Laboratories
exploratory analysis for both kbora
5 jobs
tory or plant requirements. Every volatile material present in a sample, in detectible concentration, registers on the mass spectrum. The presence of each component is thus made known—whether anticipated or not—and may supply important clues for further qualitative or quantitative analysis.
better
purity determinations.
Because
of
this instrument's exceptional sensitivity, low "background" contamination, and highly efficient recording system it is ideally suited for detecting minute traces (five parts per million in some cases) of contaminants in nearly pure gaseous and liquid compounds.
and
faster
fundamental research may be ac-
with the
celerated and simplified because of this instrument's complete flexibility. While operation is automatic for routine work, all variables can be adjusted at the will of the operator over wide ranges for special purposes in fundamental or applied research. No. 4837
Model
21-103
The Barnstead Bantam Water Demineralizer is unsurpassed as a practical and convenient source of pure water for laboratory use.
Consolidated Analytical
Mass
Spectrometer
Get this iti' formative bulletin describing the new Model 21-103 Mass Spectrometer. Ask for Bulletin CEC1800-X36.
A new direct reading purity indicator, calibrated both in specific resistance and parts per million, tells at a glance the quality of water produced. A l s o indicates when cartridge change can be expected. Improved high capacity cannister cartridge removes more than 1 1 0 0 grains of salts by ion exchange and has How rate of 5 to 8 gallons per hour. The sturdy cast base is practical for bench or shelf use and is removable for wall mounting. The Barnstead Bantam Demineralizer is supplied complete with closely adjustable needle valve for inlet water, drain petcock, rubber delivery tube, copper inlet pipe and electric cord. For 115 volt, 5 0 - 6 0 cycle operation. N o . 4837 B a r n s t e a d B a n t a m izer, less c a r t r i d g e N o . 4837-C Cartridges, each Lots of six c a r t r i d g e s
Demineral$83.00 12.00 57.60