Continuous Ammonia Recovery from Wastewaters Using an Integrated Capacitive Flow Electrode Membrane Stripping System Changyong Zhang, Jinxing Ma, Jingke Song, Calvin He, and T. David Waite Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.8b02743 • Publication Date (Web): 21 Nov 2018 Downloaded from http://pubs.acs.org on November 28, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 31
Environmental Science & Technology
1
Continuous Ammonia Recovery from Wastewaters Using an Integrated
2
Capacitive Flow Electrode Membrane Stripping System
3
Changyong Zhang,a Jinxing Ma,a Jingke Song,a,b Calvin He,a and T. David Waite*a
4
a UNSW
Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
5 6
bCollege
of Environmental Science and Engineering, State Key Laboratory of Pollution
7
Control and Resource Reuse, Tongji University, Shanghai, 200092, P.R. China; Shanghai
8
Institute of Pollution Control and Ecological Security, Shanghai, 200092, P.R. China
9
Email
addresses:
[email protected] (Changyong
Zhang);
10
[email protected] (Jinxing Ma); jingke.song@ student.unsw.edu.au (Jingke Song);
11
[email protected] (Calvin He);
[email protected] (T. David Waite)
__________________________________ 12
*Corresponding authors: Professor T. David Waite;
[email protected] ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 31
13
ABSTRACT
14
We have previously described a novel flow-electrode capacitive deionization (FCDI) unit
15
combined with a hydrophobic gas-permeable hollow fiber membrane contactor (designated
16
“CapAmm”) and presented results showing efficient recovery of ammonia from
17
synthetic wastewaters (Zhang et al., ES&T Letters 2018, 5, 43–49). We extend this earlier
18
study here with description of an FCDI system with integrated flat sheet gas permeable
19
membrane with comprehensive assessment of ammonia recovery performance from both
20
dilute and concentrated wastewaters. The integrated CapAmm cell exhibited excellent
21
ammonia removal and recovery efficiencies (up to ~90% and ~80% respectively). The energy
22
consumptions for ammonia recovery from low-strength (i.e., domestic) and high-strength
23
(i.e., synthetic urine) wastewaters were 20.4 kWh kg−1 N and 7.8 kWh kg−1 N, respectively,
24
with these values comparable to those of more conventional alternatives. Stable ammonia
25
recovery and salt removal performance was achieved over more than two days of continuous
26
operation with ammonia concentrated by ~80 times that of the feed stream. These results
27
demonstrate that the integrated CapAmm system described here could be a cost-effective
28
technology capable of treating wastewaters and realizing both nutrient recovery and water
29
reclamation in a sustainable manner.
dilute
30 31
KEYWORDS
32
Ammonia recovery, flow electrode capacitive deionization, flat-sheet membrane, nitrogen
33
fertilizer, CapAmm
2 ACS Paragon Plus Environment
Page 3 of 31
Environmental Science & Technology
34
1. INTRODUCTION
35
While nitrogen gas constitutes about 78% of the terrestrial atmosphere, the availability of its
36
active forms (i.e., ammonium, nitrite and nitrate) as essential nutrients for agricultural plant
37
growth and other anthropogenic uses is limited.1 The invention of the Haber-Bosch process in
38
the early twentieth century enabled the manufacture of ammonia (an important raw material
39
for N-based fertilizers) on an industrial scale with the ready availability of this essential
40
nutrient dramatically enhancing global agricultural productivity and consequently economic
41
growth.1-3 However, the Haber-Bosch process involves the chemical combination of nitrogen
42
and hydrogen gas under high temperature (~500 ℃) and high pressure (200-300 atm)
43
conditions, accounting for about 2% of the world energy consumption and 1.6% of global
44
greenhouse gases emissions.4,
45
improvement in living standards, the demand for nitrogen fertilizer is projected to increase by
46
50% by 2050.6 Therefore, the development of more sustainable, efficient, and economic
47
routes for the production of ammonium-based fertlizers is of great significance.7-9
5
With the continuous increase in world population and
48
From a lifecycle perspective, most food proteins are degraded to ammonium ions and/or
49
urea in metabolic processes and end up in sewage. It is reported that the waste stream
50
accounts for 18-21% of the N-fertilizers that are produced by industrial nitrogen fixation
51
with the discharge of sewage containing even dilute concentrations of nitrogen into
52
waterbodies creating various negative environmental impacts including the deterioration of
53
water quality and loss of biodiversity.3, 11-13 While conventional wastewater treatment plants
54
might take advantage of nitrification/denitrification processes to convert reactive nitrogen
55
back to N2, this practice essentially attempts to reverse the ammonia production process from
56
which most of the sewage nitrogen is derived.14 Therefore, processes that enable the direct
57
recovery of ammonia from sewage/urine and effectively close the loop between fertilizer
58
production and wastewater treatment rather than using N2 as an intermediate have attracted 3 ACS Paragon Plus Environment
10
Environmental Science & Technology
59
increasing attention in view of the potential enormous economic and environmental benefits.
60
Of the technologies available, air-stripping followed by acid adsorption is a well-
61
established process that has been intensively studied over the last decade. However, air-
62
stripping requires the addition of extra base (to raise the pH to 9.5-12) and/or heating to 25-
63
85 ℃ to covert ammonium (NH4+) to its volatile form (NH3), resulting in high energy
64
consumption (3.9-28.2 kWh kg−1 N).15,
65
ammonium ions first being selectively adsorbed (by materials such as zeolites, resins and
66
biochar) followed by chemical desorption to generate a concentrated ammonium stream.17, 18
67
The drawbacks of this technology relate to the need for a large amount of chemicals (such as
68
NaCl and NaOH) to regenerate the adsorbents. Recently, electrochemical ammonia removal
69
(and recovery) technologies have gained in popularity as a result of advantages such as
70
efficient ammonium enrichment driven by the electrical field and concomitant pH increase
71
that enables ammonia recovery (e.g., by methods such as membrane stripping). In a dual-
72
chamber electrochemical system, NH4+ migrates to the negatively charged chamber where it
73
is then transformed to NH3 and recovered as value added products, with an average energy
74
consumption ranging from 10 to 30 kWh kg−1 N.5, 19-23 Bio-electrochemical systems (BES),
75
which use bacteria at the anode to oxidize organic matter and produce electricity, can recover
76
ammonia at a lower energy demand (< 5 kWh kg−1 N) 24-28 though the recovery rate requires
77
further improvement.
16
Ion exchange is another recovery method with
78
Capacitive membrane stripping for ammonia recovery (CapAmm), first proposed by
79
Waite’s group,29 involves use of a flow-electrode capacitive deionization unit and a gas-
80
permeable membrane contactor. This technology allows simultaneous salt removal and
81
ammonia recovery from dilute wastewaters. While the mechanism involving NH4+ migration
82
and transformation are similar to those reported in conventional electrochemical systems,5 the
83
capacitive ion immobilisation and extraction from wastewaters as a result of the formation of 4 ACS Paragon Plus Environment
Page 4 of 31
Page 5 of 31
Environmental Science & Technology
84
electrical double layers on the charged flow-electrode sustains high coulombic efficiency in
85
the CapAmm system.29,
86
hollow-fibre membrane contactor, the CapAmm process could achieve an ammonium
87
recovery rate of ~60% with relatively low energy requirement.29 Although the CapAmm
88
process is, potentially, highly competitive with other technologies for the recovery of ammonia
89
from dilute wastewaters in view of its moderate operating conditions (e.g., low voltage and
90
temperature independence) and high energy efficiency, consideration should be given to (i)
91
simplification of the CapAmm configuration, (ii) optimisation of operating conditions, particularly
92
in relation to minimization of energy consumption, (iii) potential application of the CapAmm
93
process for ammonia recovery from high-strength wastewaters (e.g., urine, digestate and
94
landfill leachate) and (iv) the possibility of continuous (long-term) operation before this
95
method could be recommended as a viable choice for large-scale ammonia recovery from
96
wastewaters.
30
Results of our previous study showed that with the use of a
97
To facilitate achievement of the goals mentioned above, an integrated CapAmm system was
98
developed in this study (Figure 1). Compared to the previous configuration that requires ex-
99
situ ammonia stripping,29 a flat-sheet gas-permeable membrane was inserted
into an
100
electrochemical unit in the new design, thus providing a more compact and cost-effective
101
means of ammonia recovery. Impacts of different operating conditions on the performance of
102
this modified CapAmm process were evaluated in order to ascertain the effect of particular
103
parameters on ammonia recovery and energy demand. Continuous ammonia recovery (and
104
water desalination) was then carried out using the optimal operating conditions identified
105
with detailed analysis of the opportunities and challenges likely to be encountered in scaling
106
up the CapAmm process. The overarching goal of this study was to ascertain how to best
107
implement the CapAmm process such that ammonia and water recovery were maximized and
108
energy usage minimized. 5 ACS Paragon Plus Environment
Environmental Science & Technology
109
2. MATERIAL AND METHODS
110
2.1. Experiment Setup. The structure of the CapAmm apparatus is shown in Figure 1. It is a
111
four-chambered parallel plate reactor in which four square silicon gasket frames and three
112
membranes (i.e., anion exchange membrane (AEM), cation exchange membrane (CEM) and
113
flat-sheet gas membrane (FGM)) were bolted together between two acrylic end plates to
114
create the anode, desalination, cathode and acid chambers respectively (Figures 1a and b).
115
AEM-Type I and CEM-Type I were provided by FUJIFILM Europe and the FGM was
116
obtained from Ningbo Changqi Porous Membrane Technology Co., Ltd (Ningbo, China).
117
The effective contact area (Aeff) between flow electrode and the membrane was 58.0 cm2. The
118
desalination chamber (~2.5 mL) consisted of a nylon spacer sheet (100-mesh, 160 mm × 70
119
mm) residing within the silicone gasket (500 μm thickness) sandwiched between the AEM
120
and CEM.31,
121
channels and the circulation reservoirs (Figures 1a and c). Similar to the desalination chamber,
122
the acid chamber also consisted of a nylon spacer sheet (100-mesh, 160 mm × 70 mm) placed
123
within a silicone gasket (500 μm thickness) between the FGM and the acrylic end plate (Figure
124
1a).
125
2.2. Operating Conditions. In this study, aqueous solutions for the saline wastewater and
126
flow-electrode electrolyte were prepared using 18.2 MΩ cm Milli-Q water (Millipore) and
127
NaCl and NH4Cl solutes (>99.0%, ACS grade) from Sigma Aldrich. The effects of
128
operational parameters (carbon contents, current densities, HRTs and operational modes)
129
were first investigated with the CapAmm operated in single-pass mode with synthetic dilute
130
wastewater containing ~1000 mg L−1 NaCl and ~43 mg L−1 NH4+-N (similar to that of real
131
AnMBR effluent) running through the desalination chamber at different flow rates with
132
corresponding hydraulic retention times (HRT) of 0.98, 1.48, 1.96, and 2.94 min. The
133
electrical conductivity of the treated wastewater was continuously monitored with the use of
32
The flow electrodes were continuously cycled between the graphitic flow
6 ACS Paragon Plus Environment
Page 6 of 31
Page 7 of 31
Environmental Science & Technology
134
a conductivity meter (CON-BTA, Vernier) connected to a data acquisition system
135
(SensorDAQ, Vernier). To evaluate the effect of carbon content on CapAmm performance,
136
three carbon mass loadings (of 2, 5, and 10 wt%) were chosen and tested. Before all
137
experiments, the flowable electrodes were continually mixed using a magnetic stirrer to
138
achieve homogeneous carbon suspensions.32 A 40 mL receiving solution (0.5 M sulfuric acid)
139
was continuously recirculated at 50 mL min−1 between the acid chamber and a stirred acid
140
reservoir (Figure 1a).
141
In this study, ammonia removal and recovery in CapAmm were carried out at a constant
142
current density (1.8-10.4 A m−2) using a DC power supply. The performance in two
143
operational modes, i.e., isolated closed-cycle (ICC) and short-circuited closed-cycle (SCC)
144
modes (Figure 1c) were compared as reported previously.33-35 In ICC mode, 40 mL positively
145
and negatively charged flow electrodes were individually recirculated between the CapAmm
146
cell and two stirred reservoirs. A 2-hour charging stage was followed by reverse-current
147
discharging (~0.3 h) to regenerate the electrodes and recover part of the energy. In SCC mode,
148
80 mL carbon suspension was pumped in parallel through the anodic and cathodic flow
149
channels and then returned and mixed in the reservoir with this approach resulting in charge
150
neutralization and regeneration of the electrodes (Figure 1c). However, the acid and base
151
produced by Faradaic reactions in the flow-electrode chamber will also be neutralized,
152
resulting in a stable solution pH of around 7. Therefore, when operated in SCC mode, 0.5 mL
153
2 M NaOH solution was periodically added into the flow electrodes to maintain an average
154
pH value around 11 (a similar pH to that achieved in ICC mode). Control experiments were
155
conducted under similar conditions but without addition of NaOH solutions.
156
Real wastewater collected from a local AnMBR wastewater treatment plant was then
157
treated by CapAmm under the optimal conditions obtained from the studies on synthetic
158
wastewater. The water quality of the real wastewater used is provided in Table S1. 7 ACS Paragon Plus Environment
Environmental Science & Technology
159
Meanwhile, the possibility of ammonia recovery from high-strength wastewaters (in this case
160
synthetic urine) using CapAmm was also tested. In order to achieve better removal/recovery
161
performance, lower current density (27.2 A m−2) and longer HRT (5.88 min) were applied.
162
Finally, continuous operation of the CapAmm was conducted in ICC mode over 50
163
hours (25 cycles) of operation. Each cycle involved the sequence of (i) 2-h charging for
164
electrosorption at a constant current density, (ii) regeneration of the electrodes by mixing the
165
charged slurry and replacement of part of the electrolyte after sedimentation, and (iii) equal
166
division of the mixed electrodes into the reservoirs. The analytical methods and calculations
167
are presented in Supporting Information.
168
3. RESULTS AND DISCUSSION
169
3.1. Integrated Design of CapAmm. In this study, we developed an innovative and compact
170
electrochemical system for ammonia recovery (and N-based fertilizer production) from
171
wastewaters. Graphite plates carved with cut-through serpentine flow path channels (3 mm
172
wide and 3 mm deep) (Figure 1d) were used as current collectors. This design allows efficient
173
electron transfer between the flow electrodes and current collectors on the side walls of the
174
flow channels. Meanwhile, in the cathode chamber, the flow electrode can readily contact
175
with both a CEM and flat-sheet gas membrane (FGM) in the flow channels with the
176
arrangement providing an effective pathway for ammonium migration from the desalination
177
chamber to the cathode chamber followed by transport into the acid chamber during in-situ
178
membrane stripping (Figure 1b). The FGM used in this study was comprised of a thin
179
expanded polytetrafluoroethylene (ePTFE) active layer and a non-woven fabric support layer with
180
a total membrane thickness of 80 μm. The average pore size and porosity of the ePTFE active
181
layer were 0.45 µM and 90% (Figure 1e), respectively. The FGM was highly hydrophobic
182
with a contact angle of approximate 127.8 degrees (Figures 1f and g), indicating the ability of
183
allowing the migration of ammonia across the membrane whilst preventing the permeation of 8 ACS Paragon Plus Environment
Page 8 of 31
Page 9 of 31
Environmental Science & Technology
184
water, dissolved ions and carbon particles, thus guaranteeing the production of high purity
185
ammonia in the receiving solution.
186
With regard to the essential transformation of ammonium ions to volatile ammonia
187
(NH3) in the cathode chamber prior to the recovery process (Figure 1b), at room temperature
188
(i.e., 293 K), pH is the key factor determining the fraction of NH3 in the total ammonia
189
nitrogen (TAN) present ([NH3]/[TAN] = 10pH/(e21.3+10pH)).36 While elevated pHs (pH >11)
190
have been reported in the recirculation tank of the cathode in CapAmm as a result of
191
concomitant Faradaic reactions,37 it should be noted that the local pH near the current
192
collector (and flow channels) can be much higher than that of the bulk carbon suspension in
193
the recirculation tank. Therefore, it is expected that the integrated design will favour the
194
transformation and subsequent recovery of ammonia in-situ.
195
3.2. Optimisation of CapAmm System
196
3.2.1. The Effects of Carbon Content in Flow Electrode. Figure 2 and Figures S1-5
197
summarise the ion removal and ammonia recovery performance using flow electrodes of
198
different carbon contents. Under a constant charging current density of 6.8 A m−2 and HRT of
199
1.48 min, an increase in the carbon content has a positive effect on ion removal with much
200
lower steady-state effluent conductivity (1) in the influent stream.45 In contrast, our
347
CapAmm cell only required 20.6 kWh kg−1 N of electrical energy under optimal operating
348
conditions. The average electrical energy consumption for desalination of the wastewater was
349
only 0.54 kWh m−3, much lower than other similar technologies in treating dilute streams.
350
When it comes to handling high-strength wastewaters such as urine, digestate, landfill
351
leachate and animal waste, there are a number of competitive approaches. These methods
352
generally include an electrochemical unit (i.e., bioelectrochemical systems (BESs),
353
electrodialysis or capacitive deionization) to transport ammonium ions towards the cathode
354
(where pH automatically increases without base addition) and an ammonia separation unit
355
(i.e., air stripping system, gas membrane contactor or air cathode) to selectively recover
356
ammonia. BES-based processes (i.e., MFC, MEC and MDC), which produce electricity from
357
the microbial oxidation of organic matter, concentrate ammonia in the cathode enabling
358
ammonia recovery at extremely low energy consumption (< 5 kWh kg−1 N).24, 15 ACS Paragon Plus Environment
46-48
These
Environmental Science & Technology
Page 16 of 31
359
technologies have emerged as a promising pathway for simultaneously treating wastewater
360
(COD removal), harvesting electricity and recovering resources. The low ammonia nitrogen
361
flux obtained in MFCs can be increased by converting the system to a MEC as a result of the
362
higher bio-current generated.26 Other non-biological electrochemical systems (ESs) are capable of
363
providing higher current densities (10-100 A m−2) and enabling larger nitrogen fluxes (>100 g N
364
m−2 d−1).49, 50 Electricity energy demand and nitrogen flux for these ESs can range from 6 to 25
365
kWh kg−1 N, depending on the applied current densities (Figure S12) and wastewater type. It
366
should be noted that the ammonia separation unit will also require either extra chemicals
367
(such as sulfuric acid) or additional electricity consumption. Ammonia separation via a gas
368
membrane contactor is expected to be a better option due to the fact that only small amounts
369
of additional chemicals are required, whereas air stripping not only needs sulfuric acid for
370
ammonia adsorption but requires extra electrical energy for aeration. Our CapAmm system,
371
which combines FCDI with a gas membrane, exhibited a competitive performance with other
372
similar alternatives; at a current density of 27.2 A m−2, an electrical energy demand of 7.8
373
kWh kg−1 N was required with an ammonia flux of 264 g N m−2 d−1 and recovery efficiency
374
of 58%.
375
4. ENVIRONMENTAL IMPLICATIONS
376
Domestic wastewater is increasingly being considered as a potential resource (i.e., a source of
377
energy, fertilizing nutrients and reclaimed water) rather than as a waste. One approach that
378
appears feasible involves the use of AnMBR for COD removal and biogas production
379
(energy recovery) followed by the use of CapAmm for nitrogen and phosphate capture
380
(fertilizing nutrients recovery) and salt removal (water recovery). While this approach is
381
relatively complex and the electric energy input high, it does enable maximum resource
382
recovery
from
16 ACS Paragon Plus Environment
wastewaters.
Page 17 of 31
Environmental Science & Technology
383
An alternative approach we consider worthy of further investigation involves the
384
recovery of nitrogen and phosphate directly from high-strength streams (e.g. source separated
385
urine) using CapAmm followed by biological treatment (e.g. AnMBR, A/A/O) for organic
386
matter degradation. This approach appears more attractive because the high ammonia
387
concentrations and low concentrations of competing ions (Na+, K+ and Ca2+) in urine result in
388
much lower electrical energy consumption.21, 27, 53 In this scenario, as most of the nutrients from
389
urine (accounting for ~80% of the nutrient input in municipal WWTP) have been recovered before
390
the waste stream enters the WWTP, it may beneficially impact the cost of domestic wastewater
391
treatment as there will be little need for further N removal.
392
One major limitation of the FCDI approach is the poor electrical conductivity of the
393
carbon flow electrodes (several orders of magnitude lower than conventional static
394
electrodes)54, 55 with this restricting the ion removal/recovery efficiency and increasing the
395
internal resistance and, ultimately, resulting in higher energy consumption. In addition,
396
pumping of the flow carbon particles consumes energy, which must be taken into account in
397
the overall energy budget of the technology.56 Scale-up from small bench size units to full-
398
sized modules will also obviously be required. It is envisaged that CapAmm cells could be
399
stacked together to provide the required throughput but challenges will need to be overcome,
400
particularly with regard to optimizing flow electrode composition (i.e., electrolyte, carbon
401
loading and active electrode materials), flow cell design (i.e., channel geometry and current
402
collector materials) and operating strategy (i.e., slurry flow rate, charging/discharging time
403
control). Of particular attraction however is the low voltage, direct current requirements of
404
the technology rendering it suitable for direct use of photovoltaic power supply with
405
associated reduction in energy costs.
406 407
17 ACS Paragon Plus Environment
Environmental Science & Technology
408
ASSOCIATED CONTENT
409
Supporting Information
410
The Supporting Information is available: Details on the analytical methods and calculations,
411
and further experimental data such as temporal variation of effluent conductivity using
412
different carbon content, temporal variation of cathode pH in different operation scenario,
413
variation of NH3-N (and NH4+) concentration in cathode chamber and acid chamber,
414
distribution of ammonia, treatment of real domestic wastewater, urine and long-term
415
operation results of CapAmm (Figure S1-12 and Table S1).
416 417
AUTHOR INFORMATION
418
Corresponding Author
419
*Phone/fax: +61-2-9385-5060. E-mail:
[email protected] 420
ORCID:
421
Changyong Zhang: 0000-0002-9288-627X
422
Jinxing Ma: 0000-0002-5087-3972
423
T. David Waite: 0000-0002-5411-3233
424
Notes
425
The authors declare no competing financial interest.
426
ACKNOWLEDGEMENT
427
We gratefully acknowledge funding support from the Australian Research Council through
428
ARC Linkage Grant LP170101180. Support for Dr Jinxing Ma through a UNSW Vice
429
Chancellor’s Postdoctoral Fellowship is gratefully acknowledged.
18 ACS Paragon Plus Environment
Page 18 of 31
Page 19 of 31
Environmental Science & Technology
430
REFERENCES
431
1. Gruber, N.; Galloway, J. N., An Earth-system perspective of the global nitrogen cycle. Nature 2008, 451,
432
293.
433
2. Galloway, J. N.; Townsend, A. R.; Erisman, J. W.; Bekunda, M.; Cai, Z.; Freney, J. R.; Martinelli, L. A.;
434
Seitzinger, S. P.; Sutton, M. A., Transformation of the nitrogen cycle: recent trends, questions, and potential
435
solutions. Science 2008, 320, 889-892.
436
3. Erisman, J. W.; Sutton, M. A.; Galloway, J.; Klimont, Z.; Winiwarter, W., How a century of ammonia
437
synthesis changed the world. Nat. Geosci. 2008, 1, 636.
438
4. Zhou, F.; Azofra, L. M.; Ali, M.; Kar, M.; Simonov, A. N.; McDonnell-Worth, C.; Sun, C.; Zhang, X.;
439
MacFarlane, D. R., Electro-synthesis of ammonia from nitrogen at ambient temperature and pressure in ionic
440
liquids. Energy Environ. Sci. 2017, 10, 2516-2520.
441
5. Luther, A. K.; Desloover, J.; Fennell, D. E.; Rabaey, K., Electrochemically driven extraction and recovery of
442
ammonia from human urine. Water Res. 2015, 87, 367-77.
443
6. Sutton, M. A.; Bleeker, A., Environmental science: the shape of nitrogen to come. Nature 2013, 494, 435.
444
7. Guo, C.; Ran, J.; Vasileff, A.; Qiao, S.-Z., Rational design of electrocatalysts and photo(electro)catalysts for
445
nitrogen reduction to ammonia (NH3) under ambient conditions. Energy Environ. Sci. 2018, 11, 45-56.
446
8. Sengupta, S.; Nawaz, T.; Beaudry, J., Nitrogen and phosphorus recovery from wastewater. Curr. Pollut. Rep.
447
2015, 1, 155-166.
448
9. Luo, Z.; Hu, S.; Chen, D.; Zhu, B., From production to consumption: A coupled human-environmental
449
nitrogen flow analysis in China. Environ. Sci. Technol. 2018, 52, 2025-2035.
450
10. Mulder, A., The quest for sustainable nitrogen removal technologies. Water Sci. Technol. 2003, 48, 67-75.
451
11. Zhao, Y.; Xia, Y.; Ti, C.; Shan, J.; Li, B.; Xia, L.; Yan, X., Nitrogen removal capacity of the river network
452
in a high nitrogen loading region. Environ. Sci. Technol. 2015, 49, 1427-35.
453
12. Duce, R.; LaRoche, J.; Altieri, K.; Arrigo, K.; Baker, A.; Capone, D.; Cornell, S.; Dentener, F.; Galloway,
454
J.; Ganeshram, R., Impacts of atmospheric anthropogenic nitrogen on the open ocean. Science 2008, 320, 893-
455
897.
456
13. Larsen, T. A.; Udert, K. M.; Lienert, J., Source separation and decentralization for wastewater management.
457
IWA Publishing: 2013.
458
14. Galloway, J. N.; Dentener, F. J.; Capone, D. G.; Boyer, E. W.; Howarth, R. W.; Seitzinger, S. P.; Asner, G.
459
P.; Cleveland, C. C.; Green, P.; Holland, E. A., Nitrogen cycles: past, present, and future. Biogeochemistry
19 ACS Paragon Plus Environment
Environmental Science & Technology
460
2004, 70, 153-226.
461
15. Antonini, S.; Paris, S.; Eichert, T.; Clemens, J., Nitrogen and phosphorus recovery from human urine by
462
struvite precipitation and air stripping in Vietnam. Clean - Soil, Air, Water 2011, 39, 1099-1104.
463
16. Başakçilardan-Kabakci, S.; İpekoğlu, A. N.; Talinli, I., Recovery of ammonia from human urine by stripping
464
and absorption. Environ. Eng. Sci. 2007, 24, 615-624.
465
17. Wang, S.; Peng, Y., Natural zeolites as effective adsorbents in water and wastewater treatment. Chem. Eng.
466
J. 2010, 156, 11-24.
467
18. Tarpeh, W. A.; Udert, K. M.; Nelson, K. L., Comparing ion exchange adsorbents for nitrogen recovery from
468
source-separated urine. Environ. Sci. Technol. 2017, 51, 2373-2381.
469
19. Desloover, J.; Woldeyohannis, A. A.; Verstraete, W.; Boon, N.; Rabaey, K., Electrochemical resource
470
recovery from digestate to prevent ammonia toxicity during anaerobic digestion. Environ. Sci. Technol. 2012,
471
46, 12209-16.
472
20. Rodriguez Arredondo, M.; Kuntke, P.; Ter Heijne, A.; Hamelers, H. V.; Buisman, C. J., Load ratio
473
determines the ammonia recovery and energy input of an electrochemical system. Water Res. 2017, 111, 330-
474
337.
475
21. Kuntke, P.; Rodriguez Arredondo, M.; Widyakristi, L.; Ter Heijne, A.; Sleutels, T. H.; Hamelers, H. V.;
476
Buisman, C. J., Hydrogen gas recycling for energy efficient ammonia recovery in blectrochemical systems.
477
Environ. Sci. Technol. 2017, 51, 3110-3116.
478
22. Matassa, S.; Batstone, D. J.; Hulsen, T.; Schnoor, J.; Verstraete, W., Can direct conversion of used nitrogen
479
to new feed and protein help feed the world? Environ. Sci. Technol. 2015, 49, 5247-54.
480
23. Desloover, J.; De Vrieze, J.; Van de Vijver, M.; Mortelmans, J.; Rozendal, R.; Rabaey, K., Electrochemical
481
nutrient recovery enables ammonia toxicity control and biogas desulfurization in anaerobic digestion. Environ.
482
Sci. Technol. 2015, 49, 948-55.
483
24. Kuntke, P.; Smiech, K. M.; Bruning, H.; Zeeman, G.; Saakes, M.; Sleutels, T. H.; Hamelers, H. V.;
484
Buisman, C. J., Ammonium recovery and energy production from urine by a microbial fuel cell. Water Res.
485
2012, 46, 2627-36.
486
25. Zamora, P.; Georgieva, T.; Ter Heijne, A.; Sleutels, T. H. J. A.; Jeremiasse, A. W.; Saakes, M.; Buisman, C.
487
J. N.; Kuntke, P., Ammonia recovery from urine in a scaled-up microbial electrolysis cell. J. Power Sources
488
2017, 356, 491-499.
489
26. Kuntke, P.; Sleutels, T. H. J. A.; Saakes, M.; Buisman, C. J. N., Hydrogen production and ammonium
20 ACS Paragon Plus Environment
Page 20 of 31
Page 21 of 31
Environmental Science & Technology
490
recovery from urine by a microbial electrolysis cell. Int. J. Hydrogen Energy 2014, 39, 4771-4778.
491
27. Ledezma, P.; Jermakka, J.; Keller, J.; Freguia, S., Recovering nitrogen as a solid without chemical dosing:
492
bio-electroconcentration for recovery of nutrients from urine. Environ. Sci. Technol. Lett. 2017, 4, 119-124.
493
28. Ma, J.; Wang, Z.; Zhang, J.; Waite, T. D.; Wu, Z., Cost-effective Chlorella biomass production from dilute
494
wastewater using a novel photosynthetic microbial fuel cell (PMFC). Water Res. 2017, 108, 356-364.
495
29. Zhang, C.; Ma, J.; He, D.; Waite, T. D., Capacitive membrane stripping for ammonia recovery (CapAmm)
496
from dilute wastewaters. Environ. Sci. Technol. Lett. 2017, 5, 43-49.
497
30. Zhang, C.; He, D.; Ma, J.; Tang, W.; Waite, T. D., Faradaic reactions in capacitive deionization (CDI) -
498
problems and possibilities: A review. Water Res. 2018, 128, 314-330.
499
31. Tang, W.; Kovalsky, P.; He, D.; Waite, T. D., Fluoride and nitrate removal from brackish groundwaters by
500
batch-mode capacitive deionization. Water Res. 2015, 84, 342-9.
501
32. Ma, J.; He, D.; Tang, W.; Kovalsky, P.; He, C.; Zhang, C.; Waite, T. D., Development of redox-active flow
502
electrodes for high-performance capacitive deionization. Environ. Sci. Technol. 2016, 50, 13495-13501.
503
33. Jeon, S.-i.; Yeo, J.-g.; Yang, S.; Choi, J.; Kim, D. K., Ion storage and energy recovery of a flow-electrode
504
capacitive deionization process. J. Mater. Chem. A 2014, 2, 6378.
505
34. Doornbusch, G. J.; Dykstra, J. E.; Biesheuvel, P. M.; Suss, M. E., Fluidized bed electrodes with high carbon
506
loading for water desalination by capacitive deionization. J. Mater. Chem. A 2016, 4, 3642-3647.
507
35. He, C.; Ma, J.; Zhang, C.; Song, J.; Waite, T. D., Short-circuited closed-cycle operation of flow-electrode
508
CDI for brackish water softening. Environ. Sci. Technol. 2018.
509
36. Ahn, Y. T.; Hwang, Y. H.; Shin, H. S., Application of PTFE membrane for ammonia removal in a
510
membrane contactor. Water Sci. Technol. 2011, 63, 2944.
511
37. Nativ, P.; Badash, Y.; Gendel, Y., New insights into the mechanism of flow-electrode capacitive
512
deionization. Electrochem. Commun. 2017, 76, 24-28.
513
38. Hatzell, K. B.; Eller, J.; Morelly, S. L.; Tang, M. H.; Alvarez, N. J.; Gogotsi, Y., Direct observation of active
514
material interactions in flowable electrodes using X-ray tomography. Faraday Discuss. 2017, 199, 511-524.
515
39. Presser, V.; Dennison, C. R.; Campos, J.; Knehr, K. W.; Kumbur, E. C.; Gogotsi, Y., The electrochemical
516
flow capacitor: A new concept for rapid energy storage and recovery. Adv. Energy Mater. 2012, 2, 895-902.
517
40. Tran, A. T. K.; Zhang, Y.; Lin, J.; Mondal, P.; Ye, W.; Meesschaert, B.; Pinoy, L.; Van der Bruggen, B.,
518
Phosphate pre-concentration from municipal wastewater by selectrodialysis: Effect of competing components.
519
Sep. Purif. Technol. 2015, 141, 38-47.
21 ACS Paragon Plus Environment
Environmental Science & Technology
520
41. Zhou, F.; Gao, T.; Luo, M.; Li, H., Preferential electrosorption of anions by C/Na0.7MnO2 asymmetrical
521
electrodes. Sep. Purif. Technol. 2018, 191, 322-327.
522
42. Galama, A. H.; Post, J. W.; Cohen Stuart, M. A.; Biesheuvel, P. M., Validity of the boltzmann equation to
523
describe Donnan equilibrium at the membrane-solution interface. J. Membr. Sci. 2013, 442, 131-139.
524
43. Ma, J.; He, C.; He, D.; Zhang, C.; Waite, T. D., Analysis of capacitive and electrodialytic contributions to
525
water desalination by flow-electrode CDI. Water Res. 2018, 144, 296-303.
526
44. Yang, Y.; Shin, J.; Jasper, J. T.; Hoffmann, M. R., Multilayer heterojunction anodes for saline wastewater
527
treatment: design strategies and reactive species generation mechanisms. Environ. Sci. Technol. 2016, 50, 8780-
528
7.
529
45. Ren, S.; Li, M.; Sun, J.; Bian, Y.; Zuo, K.; Zhang, X.; Liang, P.; Huang, X., A novel electrochemical reactor
530
for nitrogen and phosphorus recovery from domestic wastewater. Front. Environ. Sci. Eng. 2017, 11.
531
46. Sotres, A.; Cerrillo, M.; Vinas, M.; Bonmati, A., Nitrogen recovery from pig slurry in a two-chambered
532
bioelectrochemical system. Bioresour. Technol. 2015, 194, 373-82.
533
47. Zhang, Y.; Angelidaki, I., Submersible microbial desalination cell for simultaneous ammonia recovery and
534
electricity production from anaerobic reactors containing high levels of ammonia. Bioresour. Technol. 2015,
535
177, 233-9.
536
48. Zhang, Y.; Angelidaki, I., Recovery of ammonia and sulfate from waste streams and bioenergy production
537
via bipolar bioelectrodialysis. Water Res. 2015, 85, 177-84.
538
49. Tarpeh, W. A.; Barazesh, J. M.; Cath, T. Y.; Nelson, K. L., Electrochemical stripping to recover nitrogen
539
from source-separated urine. Environ. Sci. Technol. 2018, 52, 1453-1460.
540
50. Kuntke, P.; Sleutels, T.; Rodriguez Arredondo, M.; Georg, S.; Barbosa, S. G.; Ter Heijne, A.; Hamelers, H.
541
V. M.; Buisman, C. J. N., (Bio)electrochemical ammonia recovery: progress and perspectives. Appl. Microbiol.
542
Biotechnol. 2018, 102, 3865-3878.
543
51. Zhang, C.; He, D.; Ma, J.; Waite, T. D., Active chlorine mediated ammonia oxidation revisited: Reaction
544
mechanism, kinetic modelling and implications. Water Res. 2018, 145, 220-230.
545
52. Hou, D.; Iddya, A.; Chen, X.; Wang, M.; Zhang, W.; Ding, Y.; Jassby, D.; Ren, Z. J., Nickel-based
546
membrane electrodes enable high-Rate electrochemical ammonia recovery. Environ. Sci. Technol. 2018, 52,
547
8930-8938.
548
53. Tarpeh, W. A.; Barazesh, J. M.; Cath, T. Y.; Nelson, K. L., Electrochemical stripping to recover nitrogen
549
from source-separated urine. Environ. Sci. Technol. 2018.
22 ACS Paragon Plus Environment
Page 22 of 31
Page 23 of 31
Environmental Science & Technology
550
54. Xu, P.; Drewes, J. E.; Heil, D.; Wang, G., Treatment of brackish produced water using carbon aerogel-based
551
capacitive deionization technology. Water Res. 2008, 42, 2605-17.
552
55. Porada, S.; Weingarth, D.; Hamelers, H. V. M.; Bryjak, M.; Presser, V.; Biesheuvel, P. M., Carbon flow
553
electrodes for continuous operation of capacitive deionization and capacitive mixing energy generation. J.
554
Mater. Chem. A 2014, 2, 9313.
555
56. Hatzell, K. B.; Hatzell, M. C.; Cook, K. M.; Boota, M.; Housel, G. M.; McBride, A.; Kumbur, E. C.;
556
Gogotsi, Y., Effect of oxidation of carbon material on suspension electrodes for flow electrode capacitive
557
deionization. Environ. Sci. Technol. 2015, 49, 3040-7.
558
23 ACS Paragon Plus Environment
Environmental Science & Technology
559
Figure 1. Schematic representations of (a) the integrated capacitive membrane stripping
560
process for ammonia recovery (CapAmm), (b) ammonia migration, transformation and
561
recovery in the CapAmm system, and (c) isolated closed-cycle (ICC) and short-circuited
562
closed-cycle (SCC) operation of the flow-electrode. (d) A photograph of the graphite current
563
collector carved with cut-through serpentine flow channels. (e) SEM image of the active layer
564
surface of the FGM. (f) A photograph of small water droplets on the surface of the FGM with
565
the contact angle shown in (g). AEM, CEM and FGM represent anion exchange membrane,
566
cation exchange membrane and flat-sheet gas membrane respectively.
24 ACS Paragon Plus Environment
Page 24 of 31
Environmental Science & Technology
+
Na
+
80 60 40 20
(b)
100
Current efficiency (%)
Ion removal efficiency (%)
(a)
NH4 -N
100
90
40
80 30 70 20
60
10
50 40
0 0
2
5
10
0 0
Carbon content (wt%)
50
2
4
6
8
10
Electricity consumption (kwh kg-1 N)
Page 25 of 31
Carbon content (wt%)
567
Figure 2. The variations of (a) average removal efficiencies of NH4+ and Na+ and (b)
568
dynamic current efficiency (Λ) and electric energy consumption for ammonia recovery as a
569
function of carbon content in the flow electrode (i.e., 0 wt%, 2 wt%, 5 wt% and 10 wt%). All
570
experiments were performed in ICC mode at a constant current density of 6.8 A m−2 and HRT
571
of 1.48 min.
25 ACS Paragon Plus Environment
80
(c)
70 60 50 40 30 20 10 0 1.8
3.4
6.8
10.4
Electricity consumption (kWh kg-1 N)
Electricity consumption (kWh kg-1 N)
Environmental Science & Technology
100
Page 26 of 31
(d)
80
60
40
20
0 0.98
-2
1.48
1.96
2.94
HRT (min)
Current density (A m )
572
Figure 3. Fate and distribution of ammonia in the CapAmm system at different (a) current
573
densities with a constant HRT of 1.48 min and (b) HRTs with a constant current of 6.8 A m−2.
574
Variations of electric energy consumption as a function of (c) current densities at constant
575
HRT of 1.48 min and (d) HRTs at a constant current density of 6.8 A m−2.
26 ACS Paragon Plus Environment
Page 27 of 31
Environmental Science & Technology
13
(a) ICC
12
pH
11 SCC_pH adjustment
10 9 8
SCC_no pH adjustment
7 6 0
20
40
60
80
100
120
(c)
ICC SCC_pH adjustment SCC_no pH adjustment
2.5
Voltage (V)
2.0 1.5 1.0 0.5 0.0 -0.5 -1.0 0
20
40
60
80
100 120 140
Electricity consumption (kWh kg-1 N)
Time (min) 3.0
80
(d)
60
40
20
0
Time (min)
ICC
SCC_pH adjustment
SCC_no pH adjustment
576
Figure 4. The variations of (a) pH in the cathode (or pH in the combined flow electrode in
577
SCC mode), (b) ammonia distribution, (c) cell voltage and (d) electrical energy consumption
578
in three different operation modse (i.e., ICC mode and SCC operation with/without pH
579
adjustment of the flow electrode). Experimental conditions: carbon content = 5 wt%, current
580
density = 6.8 A m−2 at the charging stage (current density = -6.8 A m−2 at the discharging stage,
581
if applicable) and HRT = 1.48 min.
27 ACS Paragon Plus Environment
Environmental Science & Technology
(a)
(b)
582 583
Figure 5. A comparison of (a) proportion of major cation ions transported across the CEM
584
and (b) CEM nitrogen flux, FGM nitrogen flux, energy consumption and current efficiency
585
when treating three different wastewaters (i.e., synthetic domestic wastewater, real domestic
586
wastewater and synthetic urine) using CapAmm system.
587
28 ACS Paragon Plus Environment
Page 28 of 31
Page 29 of 31
Environmental Science & Technology
2.0
(a)
Voltage (V)
1.6 1.2 0.8
Cathode pH
0.4
(b)
12 10 8
NH3-N (and NH4+-N) (mg L-1)
6
588
4000
(c)
3000 2000 1000 0 0
400
800
1200
1600
2000
2400
2800
3200
Time (min)
589
Figure 6. The variation of (a) cell voltage, (b) cathode pH and (c) ammonia concentration in
590
the acid chamber during the 25 cycles (50 hours in total) operation. The shade area represents
591
the pH range >9.3, indicating the deprotonation of NH4+ to NH3. Experimental conditions:
592
carbon content = 5 wt%, current density = 6.8 A m−2 at the charging stage and HRT = 1.48
593
min.
29 ACS Paragon Plus Environment
Environmental Science & Technology
594 595
Table 1 Comparison of energy consumption and ammonia removal/recovery performance using different methods aimed at ammonia removal/recovery from wastewaters. Methods Electrochemical oxidation Electrochemical oxidation CDI-like electrochemical reactor CapAmm CapAmm CapAmm CapAmm (with energy recovery)
Synthetic domestic Synthetic domestic
Current density (A m−2) 250 30
Nitrogen flux across CEM (g N m−2 d−1) n.a. n.a.
NH4+-N removal/recovery efficiency (%) ~100 95
Electricity consumption for ammonia recovery (kWh kg−1 N) 383.0 39.9
Electricity consumption for water treatment (kWh m−3) a 64.3 1.9
Synthetic domestic
2.1
7.8