Continuous Ammonia Recovery from Wastewaters Using an

It is reported that the waste stream. 50 accounts for 18-21% of the N-fertilizers that are produced by industrial nitrogen fixation 10. 51 with the di...
11 downloads 0 Views 837KB Size
Subscriber access provided by University of Otago Library

Remediation and Control Technologies

Continuous Ammonia Recovery from Wastewaters Using an Integrated Capacitive Flow Electrode Membrane Stripping System Changyong Zhang, Jinxing Ma, Jingke Song, Calvin He, and T. David Waite Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.8b02743 • Publication Date (Web): 21 Nov 2018 Downloaded from http://pubs.acs.org on November 28, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 31

Environmental Science & Technology

1

Continuous Ammonia Recovery from Wastewaters Using an Integrated

2

Capacitive Flow Electrode Membrane Stripping System

3

Changyong Zhang,a Jinxing Ma,a Jingke Song,a,b Calvin He,a and T. David Waite*a

4

a UNSW

Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Sydney, NSW, 2052, Australia

5 6

bCollege

of Environmental Science and Engineering, State Key Laboratory of Pollution

7

Control and Resource Reuse, Tongji University, Shanghai, 200092, P.R. China; Shanghai

8

Institute of Pollution Control and Ecological Security, Shanghai, 200092, P.R. China

9

Email

addresses:

[email protected]

(Changyong

Zhang);

10

[email protected] (Jinxing Ma); jingke.song@ student.unsw.edu.au (Jingke Song);

11

[email protected] (Calvin He); [email protected] (T. David Waite)

__________________________________ 12

*Corresponding authors: Professor T. David Waite; [email protected]

ACS Paragon Plus Environment

Environmental Science & Technology

Page 2 of 31

13

ABSTRACT

14

We have previously described a novel flow-electrode capacitive deionization (FCDI) unit

15

combined with a hydrophobic gas-permeable hollow fiber membrane contactor (designated

16

“CapAmm”) and presented results showing efficient recovery of ammonia from

17

synthetic wastewaters (Zhang et al., ES&T Letters 2018, 5, 43–49). We extend this earlier

18

study here with description of an FCDI system with integrated flat sheet gas permeable

19

membrane with comprehensive assessment of ammonia recovery performance from both

20

dilute and concentrated wastewaters. The integrated CapAmm cell exhibited excellent

21

ammonia removal and recovery efficiencies (up to ~90% and ~80% respectively). The energy

22

consumptions for ammonia recovery from low-strength (i.e., domestic) and high-strength

23

(i.e., synthetic urine) wastewaters were 20.4 kWh kg−1 N and 7.8 kWh kg−1 N, respectively,

24

with these values comparable to those of more conventional alternatives. Stable ammonia

25

recovery and salt removal performance was achieved over more than two days of continuous

26

operation with ammonia concentrated by ~80 times that of the feed stream. These results

27

demonstrate that the integrated CapAmm system described here could be a cost-effective

28

technology capable of treating wastewaters and realizing both nutrient recovery and water

29

reclamation in a sustainable manner.

dilute

30 31

KEYWORDS

32

Ammonia recovery, flow electrode capacitive deionization, flat-sheet membrane, nitrogen

33

fertilizer, CapAmm

2 ACS Paragon Plus Environment

Page 3 of 31

Environmental Science & Technology

34

1. INTRODUCTION

35

While nitrogen gas constitutes about 78% of the terrestrial atmosphere, the availability of its

36

active forms (i.e., ammonium, nitrite and nitrate) as essential nutrients for agricultural plant

37

growth and other anthropogenic uses is limited.1 The invention of the Haber-Bosch process in

38

the early twentieth century enabled the manufacture of ammonia (an important raw material

39

for N-based fertilizers) on an industrial scale with the ready availability of this essential

40

nutrient dramatically enhancing global agricultural productivity and consequently economic

41

growth.1-3 However, the Haber-Bosch process involves the chemical combination of nitrogen

42

and hydrogen gas under high temperature (~500 ℃) and high pressure (200-300 atm)

43

conditions, accounting for about 2% of the world energy consumption and 1.6% of global

44

greenhouse gases emissions.4,

45

improvement in living standards, the demand for nitrogen fertilizer is projected to increase by

46

50% by 2050.6 Therefore, the development of more sustainable, efficient, and economic

47

routes for the production of ammonium-based fertlizers is of great significance.7-9

5

With the continuous increase in world population and

48

From a lifecycle perspective, most food proteins are degraded to ammonium ions and/or

49

urea in metabolic processes and end up in sewage. It is reported that the waste stream

50

accounts for 18-21% of the N-fertilizers that are produced by industrial nitrogen fixation

51

with the discharge of sewage containing even dilute concentrations of nitrogen into

52

waterbodies creating various negative environmental impacts including the deterioration of

53

water quality and loss of biodiversity.3, 11-13 While conventional wastewater treatment plants

54

might take advantage of nitrification/denitrification processes to convert reactive nitrogen

55

back to N2, this practice essentially attempts to reverse the ammonia production process from

56

which most of the sewage nitrogen is derived.14 Therefore, processes that enable the direct

57

recovery of ammonia from sewage/urine and effectively close the loop between fertilizer

58

production and wastewater treatment rather than using N2 as an intermediate have attracted 3 ACS Paragon Plus Environment

10

Environmental Science & Technology

59

increasing attention in view of the potential enormous economic and environmental benefits.

60

Of the technologies available, air-stripping followed by acid adsorption is a well-

61

established process that has been intensively studied over the last decade. However, air-

62

stripping requires the addition of extra base (to raise the pH to 9.5-12) and/or heating to 25-

63

85 ℃ to covert ammonium (NH4+) to its volatile form (NH3), resulting in high energy

64

consumption (3.9-28.2 kWh kg−1 N).15,

65

ammonium ions first being selectively adsorbed (by materials such as zeolites, resins and

66

biochar) followed by chemical desorption to generate a concentrated ammonium stream.17, 18

67

The drawbacks of this technology relate to the need for a large amount of chemicals (such as

68

NaCl and NaOH) to regenerate the adsorbents. Recently, electrochemical ammonia removal

69

(and recovery) technologies have gained in popularity as a result of advantages such as

70

efficient ammonium enrichment driven by the electrical field and concomitant pH increase

71

that enables ammonia recovery (e.g., by methods such as membrane stripping). In a dual-

72

chamber electrochemical system, NH4+ migrates to the negatively charged chamber where it

73

is then transformed to NH3 and recovered as value added products, with an average energy

74

consumption ranging from 10 to 30 kWh kg−1 N.5, 19-23 Bio-electrochemical systems (BES),

75

which use bacteria at the anode to oxidize organic matter and produce electricity, can recover

76

ammonia at a lower energy demand (< 5 kWh kg−1 N) 24-28 though the recovery rate requires

77

further improvement.

16

Ion exchange is another recovery method with

78

Capacitive membrane stripping for ammonia recovery (CapAmm), first proposed by

79

Waite’s group,29 involves use of a flow-electrode capacitive deionization unit and a gas-

80

permeable membrane contactor. This technology allows simultaneous salt removal and

81

ammonia recovery from dilute wastewaters. While the mechanism involving NH4+ migration

82

and transformation are similar to those reported in conventional electrochemical systems,5 the

83

capacitive ion immobilisation and extraction from wastewaters as a result of the formation of 4 ACS Paragon Plus Environment

Page 4 of 31

Page 5 of 31

Environmental Science & Technology

84

electrical double layers on the charged flow-electrode sustains high coulombic efficiency in

85

the CapAmm system.29,

86

hollow-fibre membrane contactor, the CapAmm process could achieve an ammonium

87

recovery rate of ~60% with relatively low energy requirement.29 Although the CapAmm

88

process is, potentially, highly competitive with other technologies for the recovery of ammonia

89

from dilute wastewaters in view of its moderate operating conditions (e.g., low voltage and

90

temperature independence) and high energy efficiency, consideration should be given to (i)

91

simplification of the CapAmm configuration, (ii) optimisation of operating conditions, particularly

92

in relation to minimization of energy consumption, (iii) potential application of the CapAmm

93

process for ammonia recovery from high-strength wastewaters (e.g., urine, digestate and

94

landfill leachate) and (iv) the possibility of continuous (long-term) operation before this

95

method could be recommended as a viable choice for large-scale ammonia recovery from

96

wastewaters.

30

Results of our previous study showed that with the use of a

97

To facilitate achievement of the goals mentioned above, an integrated CapAmm system was

98

developed in this study (Figure 1). Compared to the previous configuration that requires ex-

99

situ ammonia stripping,29 a flat-sheet gas-permeable membrane was inserted

into an

100

electrochemical unit in the new design, thus providing a more compact and cost-effective

101

means of ammonia recovery. Impacts of different operating conditions on the performance of

102

this modified CapAmm process were evaluated in order to ascertain the effect of particular

103

parameters on ammonia recovery and energy demand. Continuous ammonia recovery (and

104

water desalination) was then carried out using the optimal operating conditions identified

105

with detailed analysis of the opportunities and challenges likely to be encountered in scaling

106

up the CapAmm process. The overarching goal of this study was to ascertain how to best

107

implement the CapAmm process such that ammonia and water recovery were maximized and

108

energy usage minimized. 5 ACS Paragon Plus Environment

Environmental Science & Technology

109

2. MATERIAL AND METHODS

110

2.1. Experiment Setup. The structure of the CapAmm apparatus is shown in Figure 1. It is a

111

four-chambered parallel plate reactor in which four square silicon gasket frames and three

112

membranes (i.e., anion exchange membrane (AEM), cation exchange membrane (CEM) and

113

flat-sheet gas membrane (FGM)) were bolted together between two acrylic end plates to

114

create the anode, desalination, cathode and acid chambers respectively (Figures 1a and b).

115

AEM-Type I and CEM-Type I were provided by FUJIFILM Europe and the FGM was

116

obtained from Ningbo Changqi Porous Membrane Technology Co., Ltd (Ningbo, China).

117

The effective contact area (Aeff) between flow electrode and the membrane was 58.0 cm2. The

118

desalination chamber (~2.5 mL) consisted of a nylon spacer sheet (100-mesh, 160 mm × 70

119

mm) residing within the silicone gasket (500 μm thickness) sandwiched between the AEM

120

and CEM.31,

121

channels and the circulation reservoirs (Figures 1a and c). Similar to the desalination chamber,

122

the acid chamber also consisted of a nylon spacer sheet (100-mesh, 160 mm × 70 mm) placed

123

within a silicone gasket (500 μm thickness) between the FGM and the acrylic end plate (Figure

124

1a).

125

2.2. Operating Conditions. In this study, aqueous solutions for the saline wastewater and

126

flow-electrode electrolyte were prepared using 18.2 MΩ cm Milli-Q water (Millipore) and

127

NaCl and NH4Cl solutes (>99.0%, ACS grade) from Sigma Aldrich. The effects of

128

operational parameters (carbon contents, current densities, HRTs and operational modes)

129

were first investigated with the CapAmm operated in single-pass mode with synthetic dilute

130

wastewater containing ~1000 mg L−1 NaCl and ~43 mg L−1 NH4+-N (similar to that of real

131

AnMBR effluent) running through the desalination chamber at different flow rates with

132

corresponding hydraulic retention times (HRT) of 0.98, 1.48, 1.96, and 2.94 min. The

133

electrical conductivity of the treated wastewater was continuously monitored with the use of

32

The flow electrodes were continuously cycled between the graphitic flow

6 ACS Paragon Plus Environment

Page 6 of 31

Page 7 of 31

Environmental Science & Technology

134

a conductivity meter (CON-BTA, Vernier) connected to a data acquisition system

135

(SensorDAQ, Vernier). To evaluate the effect of carbon content on CapAmm performance,

136

three carbon mass loadings (of 2, 5, and 10 wt%) were chosen and tested. Before all

137

experiments, the flowable electrodes were continually mixed using a magnetic stirrer to

138

achieve homogeneous carbon suspensions.32 A 40 mL receiving solution (0.5 M sulfuric acid)

139

was continuously recirculated at 50 mL min−1 between the acid chamber and a stirred acid

140

reservoir (Figure 1a).

141

In this study, ammonia removal and recovery in CapAmm were carried out at a constant

142

current density (1.8-10.4 A m−2) using a DC power supply. The performance in two

143

operational modes, i.e., isolated closed-cycle (ICC) and short-circuited closed-cycle (SCC)

144

modes (Figure 1c) were compared as reported previously.33-35 In ICC mode, 40 mL positively

145

and negatively charged flow electrodes were individually recirculated between the CapAmm

146

cell and two stirred reservoirs. A 2-hour charging stage was followed by reverse-current

147

discharging (~0.3 h) to regenerate the electrodes and recover part of the energy. In SCC mode,

148

80 mL carbon suspension was pumped in parallel through the anodic and cathodic flow

149

channels and then returned and mixed in the reservoir with this approach resulting in charge

150

neutralization and regeneration of the electrodes (Figure 1c). However, the acid and base

151

produced by Faradaic reactions in the flow-electrode chamber will also be neutralized,

152

resulting in a stable solution pH of around 7. Therefore, when operated in SCC mode, 0.5 mL

153

2 M NaOH solution was periodically added into the flow electrodes to maintain an average

154

pH value around 11 (a similar pH to that achieved in ICC mode). Control experiments were

155

conducted under similar conditions but without addition of NaOH solutions.

156

Real wastewater collected from a local AnMBR wastewater treatment plant was then

157

treated by CapAmm under the optimal conditions obtained from the studies on synthetic

158

wastewater. The water quality of the real wastewater used is provided in Table S1. 7 ACS Paragon Plus Environment

Environmental Science & Technology

159

Meanwhile, the possibility of ammonia recovery from high-strength wastewaters (in this case

160

synthetic urine) using CapAmm was also tested. In order to achieve better removal/recovery

161

performance, lower current density (27.2 A m−2) and longer HRT (5.88 min) were applied.

162

Finally, continuous operation of the CapAmm was conducted in ICC mode over 50

163

hours (25 cycles) of operation. Each cycle involved the sequence of (i) 2-h charging for

164

electrosorption at a constant current density, (ii) regeneration of the electrodes by mixing the

165

charged slurry and replacement of part of the electrolyte after sedimentation, and (iii) equal

166

division of the mixed electrodes into the reservoirs. The analytical methods and calculations

167

are presented in Supporting Information.

168

3. RESULTS AND DISCUSSION

169

3.1. Integrated Design of CapAmm. In this study, we developed an innovative and compact

170

electrochemical system for ammonia recovery (and N-based fertilizer production) from

171

wastewaters. Graphite plates carved with cut-through serpentine flow path channels (3 mm

172

wide and 3 mm deep) (Figure 1d) were used as current collectors. This design allows efficient

173

electron transfer between the flow electrodes and current collectors on the side walls of the

174

flow channels. Meanwhile, in the cathode chamber, the flow electrode can readily contact

175

with both a CEM and flat-sheet gas membrane (FGM) in the flow channels with the

176

arrangement providing an effective pathway for ammonium migration from the desalination

177

chamber to the cathode chamber followed by transport into the acid chamber during in-situ

178

membrane stripping (Figure 1b). The FGM used in this study was comprised of a thin

179

expanded polytetrafluoroethylene (ePTFE) active layer and a non-woven fabric support layer with

180

a total membrane thickness of 80 μm. The average pore size and porosity of the ePTFE active

181

layer were 0.45 µM and 90% (Figure 1e), respectively. The FGM was highly hydrophobic

182

with a contact angle of approximate 127.8 degrees (Figures 1f and g), indicating the ability of

183

allowing the migration of ammonia across the membrane whilst preventing the permeation of 8 ACS Paragon Plus Environment

Page 8 of 31

Page 9 of 31

Environmental Science & Technology

184

water, dissolved ions and carbon particles, thus guaranteeing the production of high purity

185

ammonia in the receiving solution.

186

With regard to the essential transformation of ammonium ions to volatile ammonia

187

(NH3) in the cathode chamber prior to the recovery process (Figure 1b), at room temperature

188

(i.e., 293 K), pH is the key factor determining the fraction of NH3 in the total ammonia

189

nitrogen (TAN) present ([NH3]/[TAN] = 10pH/(e21.3+10pH)).36 While elevated pHs (pH >11)

190

have been reported in the recirculation tank of the cathode in CapAmm as a result of

191

concomitant Faradaic reactions,37 it should be noted that the local pH near the current

192

collector (and flow channels) can be much higher than that of the bulk carbon suspension in

193

the recirculation tank. Therefore, it is expected that the integrated design will favour the

194

transformation and subsequent recovery of ammonia in-situ.

195

3.2. Optimisation of CapAmm System

196

3.2.1. The Effects of Carbon Content in Flow Electrode. Figure 2 and Figures S1-5

197

summarise the ion removal and ammonia recovery performance using flow electrodes of

198

different carbon contents. Under a constant charging current density of 6.8 A m−2 and HRT of

199

1.48 min, an increase in the carbon content has a positive effect on ion removal with much

200

lower steady-state effluent conductivity (1) in the influent stream.45 In contrast, our

347

CapAmm cell only required 20.6 kWh kg−1 N of electrical energy under optimal operating

348

conditions. The average electrical energy consumption for desalination of the wastewater was

349

only 0.54 kWh m−3, much lower than other similar technologies in treating dilute streams.

350

When it comes to handling high-strength wastewaters such as urine, digestate, landfill

351

leachate and animal waste, there are a number of competitive approaches. These methods

352

generally include an electrochemical unit (i.e., bioelectrochemical systems (BESs),

353

electrodialysis or capacitive deionization) to transport ammonium ions towards the cathode

354

(where pH automatically increases without base addition) and an ammonia separation unit

355

(i.e., air stripping system, gas membrane contactor or air cathode) to selectively recover

356

ammonia. BES-based processes (i.e., MFC, MEC and MDC), which produce electricity from

357

the microbial oxidation of organic matter, concentrate ammonia in the cathode enabling

358

ammonia recovery at extremely low energy consumption (< 5 kWh kg−1 N).24, 15 ACS Paragon Plus Environment

46-48

These

Environmental Science & Technology

Page 16 of 31

359

technologies have emerged as a promising pathway for simultaneously treating wastewater

360

(COD removal), harvesting electricity and recovering resources. The low ammonia nitrogen

361

flux obtained in MFCs can be increased by converting the system to a MEC as a result of the

362

higher bio-current generated.26 Other non-biological electrochemical systems (ESs) are capable of

363

providing higher current densities (10-100 A m−2) and enabling larger nitrogen fluxes (>100 g N

364

m−2 d−1).49, 50 Electricity energy demand and nitrogen flux for these ESs can range from 6 to 25

365

kWh kg−1 N, depending on the applied current densities (Figure S12) and wastewater type. It

366

should be noted that the ammonia separation unit will also require either extra chemicals

367

(such as sulfuric acid) or additional electricity consumption. Ammonia separation via a gas

368

membrane contactor is expected to be a better option due to the fact that only small amounts

369

of additional chemicals are required, whereas air stripping not only needs sulfuric acid for

370

ammonia adsorption but requires extra electrical energy for aeration. Our CapAmm system,

371

which combines FCDI with a gas membrane, exhibited a competitive performance with other

372

similar alternatives; at a current density of 27.2 A m−2, an electrical energy demand of 7.8

373

kWh kg−1 N was required with an ammonia flux of 264 g N m−2 d−1 and recovery efficiency

374

of 58%.

375

4. ENVIRONMENTAL IMPLICATIONS

376

Domestic wastewater is increasingly being considered as a potential resource (i.e., a source of

377

energy, fertilizing nutrients and reclaimed water) rather than as a waste. One approach that

378

appears feasible involves the use of AnMBR for COD removal and biogas production

379

(energy recovery) followed by the use of CapAmm for nitrogen and phosphate capture

380

(fertilizing nutrients recovery) and salt removal (water recovery). While this approach is

381

relatively complex and the electric energy input high, it does enable maximum resource

382

recovery

from

16 ACS Paragon Plus Environment

wastewaters.

Page 17 of 31

Environmental Science & Technology

383

An alternative approach we consider worthy of further investigation involves the

384

recovery of nitrogen and phosphate directly from high-strength streams (e.g. source separated

385

urine) using CapAmm followed by biological treatment (e.g. AnMBR, A/A/O) for organic

386

matter degradation. This approach appears more attractive because the high ammonia

387

concentrations and low concentrations of competing ions (Na+, K+ and Ca2+) in urine result in

388

much lower electrical energy consumption.21, 27, 53 In this scenario, as most of the nutrients from

389

urine (accounting for ~80% of the nutrient input in municipal WWTP) have been recovered before

390

the waste stream enters the WWTP, it may beneficially impact the cost of domestic wastewater

391

treatment as there will be little need for further N removal.

392

One major limitation of the FCDI approach is the poor electrical conductivity of the

393

carbon flow electrodes (several orders of magnitude lower than conventional static

394

electrodes)54, 55 with this restricting the ion removal/recovery efficiency and increasing the

395

internal resistance and, ultimately, resulting in higher energy consumption. In addition,

396

pumping of the flow carbon particles consumes energy, which must be taken into account in

397

the overall energy budget of the technology.56 Scale-up from small bench size units to full-

398

sized modules will also obviously be required. It is envisaged that CapAmm cells could be

399

stacked together to provide the required throughput but challenges will need to be overcome,

400

particularly with regard to optimizing flow electrode composition (i.e., electrolyte, carbon

401

loading and active electrode materials), flow cell design (i.e., channel geometry and current

402

collector materials) and operating strategy (i.e., slurry flow rate, charging/discharging time

403

control). Of particular attraction however is the low voltage, direct current requirements of

404

the technology rendering it suitable for direct use of photovoltaic power supply with

405

associated reduction in energy costs.

406 407

17 ACS Paragon Plus Environment

Environmental Science & Technology

408

ASSOCIATED CONTENT

409

Supporting Information

410

The Supporting Information is available: Details on the analytical methods and calculations,

411

and further experimental data such as temporal variation of effluent conductivity using

412

different carbon content, temporal variation of cathode pH in different operation scenario,

413

variation of NH3-N (and NH4+) concentration in cathode chamber and acid chamber,

414

distribution of ammonia, treatment of real domestic wastewater, urine and long-term

415

operation results of CapAmm (Figure S1-12 and Table S1).

416 417

AUTHOR INFORMATION

418

Corresponding Author

419

*Phone/fax: +61-2-9385-5060. E-mail: [email protected]

420

ORCID:

421

Changyong Zhang: 0000-0002-9288-627X

422

Jinxing Ma: 0000-0002-5087-3972

423

T. David Waite: 0000-0002-5411-3233

424

Notes

425

The authors declare no competing financial interest.

426

ACKNOWLEDGEMENT

427

We gratefully acknowledge funding support from the Australian Research Council through

428

ARC Linkage Grant LP170101180. Support for Dr Jinxing Ma through a UNSW Vice

429

Chancellor’s Postdoctoral Fellowship is gratefully acknowledged.

18 ACS Paragon Plus Environment

Page 18 of 31

Page 19 of 31

Environmental Science & Technology

430

REFERENCES

431

1. Gruber, N.; Galloway, J. N., An Earth-system perspective of the global nitrogen cycle. Nature 2008, 451,

432

293.

433

2. Galloway, J. N.; Townsend, A. R.; Erisman, J. W.; Bekunda, M.; Cai, Z.; Freney, J. R.; Martinelli, L. A.;

434

Seitzinger, S. P.; Sutton, M. A., Transformation of the nitrogen cycle: recent trends, questions, and potential

435

solutions. Science 2008, 320, 889-892.

436

3. Erisman, J. W.; Sutton, M. A.; Galloway, J.; Klimont, Z.; Winiwarter, W., How a century of ammonia

437

synthesis changed the world. Nat. Geosci. 2008, 1, 636.

438

4. Zhou, F.; Azofra, L. M.; Ali, M.; Kar, M.; Simonov, A. N.; McDonnell-Worth, C.; Sun, C.; Zhang, X.;

439

MacFarlane, D. R., Electro-synthesis of ammonia from nitrogen at ambient temperature and pressure in ionic

440

liquids. Energy Environ. Sci. 2017, 10, 2516-2520.

441

5. Luther, A. K.; Desloover, J.; Fennell, D. E.; Rabaey, K., Electrochemically driven extraction and recovery of

442

ammonia from human urine. Water Res. 2015, 87, 367-77.

443

6. Sutton, M. A.; Bleeker, A., Environmental science: the shape of nitrogen to come. Nature 2013, 494, 435.

444

7. Guo, C.; Ran, J.; Vasileff, A.; Qiao, S.-Z., Rational design of electrocatalysts and photo(electro)catalysts for

445

nitrogen reduction to ammonia (NH3) under ambient conditions. Energy Environ. Sci. 2018, 11, 45-56.

446

8. Sengupta, S.; Nawaz, T.; Beaudry, J., Nitrogen and phosphorus recovery from wastewater. Curr. Pollut. Rep.

447

2015, 1, 155-166.

448

9. Luo, Z.; Hu, S.; Chen, D.; Zhu, B., From production to consumption: A coupled human-environmental

449

nitrogen flow analysis in China. Environ. Sci. Technol. 2018, 52, 2025-2035.

450

10. Mulder, A., The quest for sustainable nitrogen removal technologies. Water Sci. Technol. 2003, 48, 67-75.

451

11. Zhao, Y.; Xia, Y.; Ti, C.; Shan, J.; Li, B.; Xia, L.; Yan, X., Nitrogen removal capacity of the river network

452

in a high nitrogen loading region. Environ. Sci. Technol. 2015, 49, 1427-35.

453

12. Duce, R.; LaRoche, J.; Altieri, K.; Arrigo, K.; Baker, A.; Capone, D.; Cornell, S.; Dentener, F.; Galloway,

454

J.; Ganeshram, R., Impacts of atmospheric anthropogenic nitrogen on the open ocean. Science 2008, 320, 893-

455

897.

456

13. Larsen, T. A.; Udert, K. M.; Lienert, J., Source separation and decentralization for wastewater management.

457

IWA Publishing: 2013.

458

14. Galloway, J. N.; Dentener, F. J.; Capone, D. G.; Boyer, E. W.; Howarth, R. W.; Seitzinger, S. P.; Asner, G.

459

P.; Cleveland, C. C.; Green, P.; Holland, E. A., Nitrogen cycles: past, present, and future. Biogeochemistry

19 ACS Paragon Plus Environment

Environmental Science & Technology

460

2004, 70, 153-226.

461

15. Antonini, S.; Paris, S.; Eichert, T.; Clemens, J., Nitrogen and phosphorus recovery from human urine by

462

struvite precipitation and air stripping in Vietnam. Clean - Soil, Air, Water 2011, 39, 1099-1104.

463

16. Başakçilardan-Kabakci, S.; İpekoğlu, A. N.; Talinli, I., Recovery of ammonia from human urine by stripping

464

and absorption. Environ. Eng. Sci. 2007, 24, 615-624.

465

17. Wang, S.; Peng, Y., Natural zeolites as effective adsorbents in water and wastewater treatment. Chem. Eng.

466

J. 2010, 156, 11-24.

467

18. Tarpeh, W. A.; Udert, K. M.; Nelson, K. L., Comparing ion exchange adsorbents for nitrogen recovery from

468

source-separated urine. Environ. Sci. Technol. 2017, 51, 2373-2381.

469

19. Desloover, J.; Woldeyohannis, A. A.; Verstraete, W.; Boon, N.; Rabaey, K., Electrochemical resource

470

recovery from digestate to prevent ammonia toxicity during anaerobic digestion. Environ. Sci. Technol. 2012,

471

46, 12209-16.

472

20. Rodriguez Arredondo, M.; Kuntke, P.; Ter Heijne, A.; Hamelers, H. V.; Buisman, C. J., Load ratio

473

determines the ammonia recovery and energy input of an electrochemical system. Water Res. 2017, 111, 330-

474

337.

475

21. Kuntke, P.; Rodriguez Arredondo, M.; Widyakristi, L.; Ter Heijne, A.; Sleutels, T. H.; Hamelers, H. V.;

476

Buisman, C. J., Hydrogen gas recycling for energy efficient ammonia recovery in blectrochemical systems.

477

Environ. Sci. Technol. 2017, 51, 3110-3116.

478

22. Matassa, S.; Batstone, D. J.; Hulsen, T.; Schnoor, J.; Verstraete, W., Can direct conversion of used nitrogen

479

to new feed and protein help feed the world? Environ. Sci. Technol. 2015, 49, 5247-54.

480

23. Desloover, J.; De Vrieze, J.; Van de Vijver, M.; Mortelmans, J.; Rozendal, R.; Rabaey, K., Electrochemical

481

nutrient recovery enables ammonia toxicity control and biogas desulfurization in anaerobic digestion. Environ.

482

Sci. Technol. 2015, 49, 948-55.

483

24. Kuntke, P.; Smiech, K. M.; Bruning, H.; Zeeman, G.; Saakes, M.; Sleutels, T. H.; Hamelers, H. V.;

484

Buisman, C. J., Ammonium recovery and energy production from urine by a microbial fuel cell. Water Res.

485

2012, 46, 2627-36.

486

25. Zamora, P.; Georgieva, T.; Ter Heijne, A.; Sleutels, T. H. J. A.; Jeremiasse, A. W.; Saakes, M.; Buisman, C.

487

J. N.; Kuntke, P., Ammonia recovery from urine in a scaled-up microbial electrolysis cell. J. Power Sources

488

2017, 356, 491-499.

489

26. Kuntke, P.; Sleutels, T. H. J. A.; Saakes, M.; Buisman, C. J. N., Hydrogen production and ammonium

20 ACS Paragon Plus Environment

Page 20 of 31

Page 21 of 31

Environmental Science & Technology

490

recovery from urine by a microbial electrolysis cell. Int. J. Hydrogen Energy 2014, 39, 4771-4778.

491

27. Ledezma, P.; Jermakka, J.; Keller, J.; Freguia, S., Recovering nitrogen as a solid without chemical dosing:

492

bio-electroconcentration for recovery of nutrients from urine. Environ. Sci. Technol. Lett. 2017, 4, 119-124.

493

28. Ma, J.; Wang, Z.; Zhang, J.; Waite, T. D.; Wu, Z., Cost-effective Chlorella biomass production from dilute

494

wastewater using a novel photosynthetic microbial fuel cell (PMFC). Water Res. 2017, 108, 356-364.

495

29. Zhang, C.; Ma, J.; He, D.; Waite, T. D., Capacitive membrane stripping for ammonia recovery (CapAmm)

496

from dilute wastewaters. Environ. Sci. Technol. Lett. 2017, 5, 43-49.

497

30. Zhang, C.; He, D.; Ma, J.; Tang, W.; Waite, T. D., Faradaic reactions in capacitive deionization (CDI) -

498

problems and possibilities: A review. Water Res. 2018, 128, 314-330.

499

31. Tang, W.; Kovalsky, P.; He, D.; Waite, T. D., Fluoride and nitrate removal from brackish groundwaters by

500

batch-mode capacitive deionization. Water Res. 2015, 84, 342-9.

501

32. Ma, J.; He, D.; Tang, W.; Kovalsky, P.; He, C.; Zhang, C.; Waite, T. D., Development of redox-active flow

502

electrodes for high-performance capacitive deionization. Environ. Sci. Technol. 2016, 50, 13495-13501.

503

33. Jeon, S.-i.; Yeo, J.-g.; Yang, S.; Choi, J.; Kim, D. K., Ion storage and energy recovery of a flow-electrode

504

capacitive deionization process. J. Mater. Chem. A 2014, 2, 6378.

505

34. Doornbusch, G. J.; Dykstra, J. E.; Biesheuvel, P. M.; Suss, M. E., Fluidized bed electrodes with high carbon

506

loading for water desalination by capacitive deionization. J. Mater. Chem. A 2016, 4, 3642-3647.

507

35. He, C.; Ma, J.; Zhang, C.; Song, J.; Waite, T. D., Short-circuited closed-cycle operation of flow-electrode

508

CDI for brackish water softening. Environ. Sci. Technol. 2018.

509

36. Ahn, Y. T.; Hwang, Y. H.; Shin, H. S., Application of PTFE membrane for ammonia removal in a

510

membrane contactor. Water Sci. Technol. 2011, 63, 2944.

511

37. Nativ, P.; Badash, Y.; Gendel, Y., New insights into the mechanism of flow-electrode capacitive

512

deionization. Electrochem. Commun. 2017, 76, 24-28.

513

38. Hatzell, K. B.; Eller, J.; Morelly, S. L.; Tang, M. H.; Alvarez, N. J.; Gogotsi, Y., Direct observation of active

514

material interactions in flowable electrodes using X-ray tomography. Faraday Discuss. 2017, 199, 511-524.

515

39. Presser, V.; Dennison, C. R.; Campos, J.; Knehr, K. W.; Kumbur, E. C.; Gogotsi, Y., The electrochemical

516

flow capacitor: A new concept for rapid energy storage and recovery. Adv. Energy Mater. 2012, 2, 895-902.

517

40. Tran, A. T. K.; Zhang, Y.; Lin, J.; Mondal, P.; Ye, W.; Meesschaert, B.; Pinoy, L.; Van der Bruggen, B.,

518

Phosphate pre-concentration from municipal wastewater by selectrodialysis: Effect of competing components.

519

Sep. Purif. Technol. 2015, 141, 38-47.

21 ACS Paragon Plus Environment

Environmental Science & Technology

520

41. Zhou, F.; Gao, T.; Luo, M.; Li, H., Preferential electrosorption of anions by C/Na0.7MnO2 asymmetrical

521

electrodes. Sep. Purif. Technol. 2018, 191, 322-327.

522

42. Galama, A. H.; Post, J. W.; Cohen Stuart, M. A.; Biesheuvel, P. M., Validity of the boltzmann equation to

523

describe Donnan equilibrium at the membrane-solution interface. J. Membr. Sci. 2013, 442, 131-139.

524

43. Ma, J.; He, C.; He, D.; Zhang, C.; Waite, T. D., Analysis of capacitive and electrodialytic contributions to

525

water desalination by flow-electrode CDI. Water Res. 2018, 144, 296-303.

526

44. Yang, Y.; Shin, J.; Jasper, J. T.; Hoffmann, M. R., Multilayer heterojunction anodes for saline wastewater

527

treatment: design strategies and reactive species generation mechanisms. Environ. Sci. Technol. 2016, 50, 8780-

528

7.

529

45. Ren, S.; Li, M.; Sun, J.; Bian, Y.; Zuo, K.; Zhang, X.; Liang, P.; Huang, X., A novel electrochemical reactor

530

for nitrogen and phosphorus recovery from domestic wastewater. Front. Environ. Sci. Eng. 2017, 11.

531

46. Sotres, A.; Cerrillo, M.; Vinas, M.; Bonmati, A., Nitrogen recovery from pig slurry in a two-chambered

532

bioelectrochemical system. Bioresour. Technol. 2015, 194, 373-82.

533

47. Zhang, Y.; Angelidaki, I., Submersible microbial desalination cell for simultaneous ammonia recovery and

534

electricity production from anaerobic reactors containing high levels of ammonia. Bioresour. Technol. 2015,

535

177, 233-9.

536

48. Zhang, Y.; Angelidaki, I., Recovery of ammonia and sulfate from waste streams and bioenergy production

537

via bipolar bioelectrodialysis. Water Res. 2015, 85, 177-84.

538

49. Tarpeh, W. A.; Barazesh, J. M.; Cath, T. Y.; Nelson, K. L., Electrochemical stripping to recover nitrogen

539

from source-separated urine. Environ. Sci. Technol. 2018, 52, 1453-1460.

540

50. Kuntke, P.; Sleutels, T.; Rodriguez Arredondo, M.; Georg, S.; Barbosa, S. G.; Ter Heijne, A.; Hamelers, H.

541

V. M.; Buisman, C. J. N., (Bio)electrochemical ammonia recovery: progress and perspectives. Appl. Microbiol.

542

Biotechnol. 2018, 102, 3865-3878.

543

51. Zhang, C.; He, D.; Ma, J.; Waite, T. D., Active chlorine mediated ammonia oxidation revisited: Reaction

544

mechanism, kinetic modelling and implications. Water Res. 2018, 145, 220-230.

545

52. Hou, D.; Iddya, A.; Chen, X.; Wang, M.; Zhang, W.; Ding, Y.; Jassby, D.; Ren, Z. J., Nickel-based

546

membrane electrodes enable high-Rate electrochemical ammonia recovery. Environ. Sci. Technol. 2018, 52,

547

8930-8938.

548

53. Tarpeh, W. A.; Barazesh, J. M.; Cath, T. Y.; Nelson, K. L., Electrochemical stripping to recover nitrogen

549

from source-separated urine. Environ. Sci. Technol. 2018.

22 ACS Paragon Plus Environment

Page 22 of 31

Page 23 of 31

Environmental Science & Technology

550

54. Xu, P.; Drewes, J. E.; Heil, D.; Wang, G., Treatment of brackish produced water using carbon aerogel-based

551

capacitive deionization technology. Water Res. 2008, 42, 2605-17.

552

55. Porada, S.; Weingarth, D.; Hamelers, H. V. M.; Bryjak, M.; Presser, V.; Biesheuvel, P. M., Carbon flow

553

electrodes for continuous operation of capacitive deionization and capacitive mixing energy generation. J.

554

Mater. Chem. A 2014, 2, 9313.

555

56. Hatzell, K. B.; Hatzell, M. C.; Cook, K. M.; Boota, M.; Housel, G. M.; McBride, A.; Kumbur, E. C.;

556

Gogotsi, Y., Effect of oxidation of carbon material on suspension electrodes for flow electrode capacitive

557

deionization. Environ. Sci. Technol. 2015, 49, 3040-7.

558

23 ACS Paragon Plus Environment

Environmental Science & Technology

559

Figure 1. Schematic representations of (a) the integrated capacitive membrane stripping

560

process for ammonia recovery (CapAmm), (b) ammonia migration, transformation and

561

recovery in the CapAmm system, and (c) isolated closed-cycle (ICC) and short-circuited

562

closed-cycle (SCC) operation of the flow-electrode. (d) A photograph of the graphite current

563

collector carved with cut-through serpentine flow channels. (e) SEM image of the active layer

564

surface of the FGM. (f) A photograph of small water droplets on the surface of the FGM with

565

the contact angle shown in (g). AEM, CEM and FGM represent anion exchange membrane,

566

cation exchange membrane and flat-sheet gas membrane respectively.

24 ACS Paragon Plus Environment

Page 24 of 31

Environmental Science & Technology

+

Na

+

80 60 40 20

(b)

100

Current efficiency (%)

Ion removal efficiency (%)

(a)

NH4 -N

100

90

40

80 30 70 20

60

10

50 40

0 0

2

5

10

0 0

Carbon content (wt%)

50

2

4

6

8

10

Electricity consumption (kwh kg-1 N)

Page 25 of 31

Carbon content (wt%)

567

Figure 2. The variations of (a) average removal efficiencies of NH4+ and Na+ and (b)

568

dynamic current efficiency (Λ) and electric energy consumption for ammonia recovery as a

569

function of carbon content in the flow electrode (i.e., 0 wt%, 2 wt%, 5 wt% and 10 wt%). All

570

experiments were performed in ICC mode at a constant current density of 6.8 A m−2 and HRT

571

of 1.48 min.

25 ACS Paragon Plus Environment

80

(c)

70 60 50 40 30 20 10 0 1.8

3.4

6.8

10.4

Electricity consumption (kWh kg-1 N)

Electricity consumption (kWh kg-1 N)

Environmental Science & Technology

100

Page 26 of 31

(d)

80

60

40

20

0 0.98

-2

1.48

1.96

2.94

HRT (min)

Current density (A m )

572

Figure 3. Fate and distribution of ammonia in the CapAmm system at different (a) current

573

densities with a constant HRT of 1.48 min and (b) HRTs with a constant current of 6.8 A m−2.

574

Variations of electric energy consumption as a function of (c) current densities at constant

575

HRT of 1.48 min and (d) HRTs at a constant current density of 6.8 A m−2.

26 ACS Paragon Plus Environment

Page 27 of 31

Environmental Science & Technology

13

(a) ICC

12

pH

11 SCC_pH adjustment

10 9 8

SCC_no pH adjustment

7 6 0

20

40

60

80

100

120

(c)

ICC SCC_pH adjustment SCC_no pH adjustment

2.5

Voltage (V)

2.0 1.5 1.0 0.5 0.0 -0.5 -1.0 0

20

40

60

80

100 120 140

Electricity consumption (kWh kg-1 N)

Time (min) 3.0

80

(d)

60

40

20

0

Time (min)

ICC

SCC_pH adjustment

SCC_no pH adjustment

576

Figure 4. The variations of (a) pH in the cathode (or pH in the combined flow electrode in

577

SCC mode), (b) ammonia distribution, (c) cell voltage and (d) electrical energy consumption

578

in three different operation modse (i.e., ICC mode and SCC operation with/without pH

579

adjustment of the flow electrode). Experimental conditions: carbon content = 5 wt%, current

580

density = 6.8 A m−2 at the charging stage (current density = -6.8 A m−2 at the discharging stage,

581

if applicable) and HRT = 1.48 min.

27 ACS Paragon Plus Environment

Environmental Science & Technology

(a)

(b)

582 583

Figure 5. A comparison of (a) proportion of major cation ions transported across the CEM

584

and (b) CEM nitrogen flux, FGM nitrogen flux, energy consumption and current efficiency

585

when treating three different wastewaters (i.e., synthetic domestic wastewater, real domestic

586

wastewater and synthetic urine) using CapAmm system.

587

28 ACS Paragon Plus Environment

Page 28 of 31

Page 29 of 31

Environmental Science & Technology

2.0

(a)

Voltage (V)

1.6 1.2 0.8

Cathode pH

0.4

(b)

12 10 8

NH3-N (and NH4+-N) (mg L-1)

6

588

4000

(c)

3000 2000 1000 0 0

400

800

1200

1600

2000

2400

2800

3200

Time (min)

589

Figure 6. The variation of (a) cell voltage, (b) cathode pH and (c) ammonia concentration in

590

the acid chamber during the 25 cycles (50 hours in total) operation. The shade area represents

591

the pH range >9.3, indicating the deprotonation of NH4+ to NH3. Experimental conditions:

592

carbon content = 5 wt%, current density = 6.8 A m−2 at the charging stage and HRT = 1.48

593

min.

29 ACS Paragon Plus Environment

Environmental Science & Technology

594 595

Table 1 Comparison of energy consumption and ammonia removal/recovery performance using different methods aimed at ammonia removal/recovery from wastewaters. Methods Electrochemical oxidation Electrochemical oxidation CDI-like electrochemical reactor CapAmm CapAmm CapAmm CapAmm (with energy recovery)

Synthetic domestic Synthetic domestic

Current density (A m−2) 250 30

Nitrogen flux across CEM (g N m−2 d−1) n.a. n.a.

NH4+-N removal/recovery efficiency (%) ~100 95

Electricity consumption for ammonia recovery (kWh kg−1 N) 383.0 39.9

Electricity consumption for water treatment (kWh m−3) a 64.3 1.9

Synthetic domestic

2.1

7.8