Detection of Cyanobacteria in Eutrophic Water ... - ACS Publications

Jan 5, 2018 - urement) and dry cell weight of preconcentrated cyanobacteria were then obtained ... massive harmful algal bloom on the surface of Lake ...
0 downloads 0 Views 2MB Size
Subscriber access provided by READING UNIV

Article

Detection of cyanobacteria in eutrophic water using a portable electrocoagulator and NanoGene assay Eun-Hee Lee, Beelee Chua, and Ahjeong Son Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b05055 • Publication Date (Web): 05 Jan 2018 Downloaded from http://pubs.acs.org on January 10, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 31

Environmental Science & Technology

1

Detection of cyanobacteria in eutrophic water using a

2

portable electrocoagulator and NanoGene assay

3 1

4

Eun-Hee Lee, 2,* Beelee Chua, 1,*Ahjeong Son

5 6

1

Department of Environmental Science and Engineering, Ewha Womans University, Seoul, Republic of Korea

7

2

School of Electrical Engineering, Korea University, Seoul, Republic of Korea

8 9 10

*Corresponding Author, Beelee Chua: Present address. 145 Anam-ro, Seongbuk-gu, Korea University, Seoul,

11

02841, Republic of Korea; E-mail. [email protected]; Phone. +82 (2) 3290-4639

12

*Corresponding Author, Ahjeong Son: Present address. 52 Ewhayeodae-gil, Seodaemun-gu, Ewha Womans

13

University, Seoul, 03760, Republic of Korea; E-mail. [email protected]; Phone. +82 (2) 3277-3339; Fax.

14

+82 (2) 3277-3275

15

1

ACS Paragon Plus Environment

Environmental Science & Technology

Page 2 of 31

16

ABSTRACT

17

We have demonstrated the detection of cyanobacteria in eutrophic water samples using a portable

18

electrocoagulator and NanoGene assay. The electrocoagulator is designed to pre-concentrate cyanobacteria from

19

water samples prior to analysis via NanoGene assay. Using Microcystis aeruginosa laboratory culture and

20

environmental samples (cell densities ranging from 1.7 × 105 to 4.1 × 106 and 6.5 × 103 to 6.6 × 107 cells·mL-1,

21

respectively), the electrocoagulator was evaluated and compared with a conventional centrifuge. Varying the

22

operation duration from 0 to 300 s with different cell densities was first investigated. Pre-concentration

23

efficiencies (obtained via absorbance measurement) and dry cell weight of pre-concentrated cyanobacteria were

24

then obtained and compared. For laboratory samples at cell densities from 3.2 × 105 to 4.1 × 106 cells·mL-1, the

25

pre-concentration efficiencies of electrocoagulator appeared to be stable at ~60%. At lower cell densities (1.7

26

and 2.2 × 105 cells·mL-1), the pre-concentration efficiencies decreased to 33.9 ± 0.2 and 40.4 ± 5.4%,

27

respectively. For environmental samples at cell densities of 2.7 × 105 and 6.6 × 107 cells·mL-1, the

28

electrocoagulator maintained its pre-concentration efficiency at ~60%. On the other hand, the centrifuge’s pre-

29

concentration efficiencies decreased to non-detectable and below 40%, respectively. This shows that the

30

electrocoagulator outperformed the centrifuge when using eutrophic water samples. Finally, the compatibility of

31

the electrocoagulator with the NanoGene assay was verified via the successful detection of the microcystin

32

synthetase D (mcyD) gene in environmental samples. The viability of the electrocoagulator as an in situ

33

compatible alternative to the centrifuge is also discussed.

34 35

Keywords: electrocoagulator; centrifuge; pre-concentrate; cyanobacteria; NanoGene assay; Microcystis

36

aeruginosa

37 38

INTRODUCTION 2

ACS Paragon Plus Environment

Page 3 of 31

Environmental Science & Technology

39

In the summer of 2014, a three-day tap water ban was imposed in Toledo, Ohio (population ~ 300,000), due to a

40

massive harmful algal bloom on the surface of Lake Erie, USA.1-3 In the following summer, a harmful algal

41

bloom along the coast of Washington state resulted in a loss of over 9 million US dollars in razor clam fisheries

42

alone.4 According to the National Oceanic and Atmospheric Administration,5 harmful algal blooms have so far

43

occurred in every coastal state in the USA. This is because they tend to proliferate in anthropologically altered

44

environmental conditions such as eutrophic waters fed by sewage and agricultural runoff.6

45

It is well documented that harmful algal blooms can cause acute morbidity and mortality of invertebrate

46

and fish species via oxygen depletion (hypoxia and anoxia).7-10 Harmful algal blooms are also responsible for the

47

clogging of screens, fouling of weirs, and interference of floc settling in water treatment plants.11-13 They are

48

also a source of taste and odor compounds such as geosmin and 2-methylisoborneol and therefore cause

49

malodorous and unpalatable drinking water. Most importantly, harmful algal blooms that are primarily

50

composed of cyanobacteria and certain common strains of algae are known to produce toxic secondary

51

metabolites and endotoxins such as neurotoxins, cytotoxins, dermatotoxins, irritant toxins (lipopolysaccharides),

52

and hepatotoxins.14 For example, the genera Microcystis, Anabaena, and Plankthotrix can produce microcystins

53

(i.e., hepatotoxins).6 Therefore, chronic and acute exposure to microcystins can result in liver failure and cancer.

54

In this regard, in situ cyanobacterial detection, particularly detection of the above-mentioned toxigenic

55

genera, would have an obvious benefit. The rapid identification and quantification of specific toxin-producing

56

strains during a bloom would be invaluable. It would allow authorities to restrict recreational activities in parks

57

and fisheries to protect their stocks and water treatment plants to accommodate a higher than usual toxin load in

58

a timely manner. However, existing cyanobacterial detection techniques are not particularly amendable for in

59

situ deployment. So far, they have been largely limited to the analysis of field samples using laboratory-based

60

equipment (e.g., microscopic inspection, chromatographic and spectroscopic analysis, and molecular biology

61

assays).14-18 3

ACS Paragon Plus Environment

Environmental Science & Technology

62

Page 4 of 31

Furthermore, prior to analysis, the field samples require pre-concentration followed by lysis and

63

purification. Currently, pre-concentration can be achieved using a centrifuge or by filtration via a fine membrane.

64

Portable centrifuges (such as the Portable Centrifuge Kit by Healthrow Scientific) are electrical power intensive

65

(requiring a power adaptor) as well as costly (> 300 USD). Given the small size of cyanobacteria, the use of

66

filtration via a fine membrane requires a pump with high operating head and hence is also power intensive and

67

costly. Therefore, neither approach is amenable for in situ operation.

68

Inspired by the use of electrocoagulation in water treatment and algae harvesting,19-23 we have

69

developed a pocket-size portable electrocoagulator suitable for in situ cyanobacterial detection with the

70

NanoGene assay. Electrocoagulation is a well-known process that uses electricity to dissolve metal in order to

71

supply the ions required for coagulation of colloids including microorganism.24-25 In this study, aluminium was

72

used as both anode and cathode in the electrocoagulation process. At the anode surface where oxidation occurs,

73

the major products are H+, Al3+, and O2 gas. The corresponding oxidative half reactions are as follows.

74

Al → Al3+ + 3e-

(1a)

75

2H2O → O2 + 4H+ + 4e-

(1b)

76

2OH- → O2 + 2H+ + 4e-

(1c)

77

At the cathode surface where the reduction occurs, the major products are OH-, and H2 gas. The corresponding

78

reductive half reactions are as follows.

79

2H2O + 2e- → H2 + 2OH-

(2a)

80

2H+ + 2e- → H2

(2b)

81

Aluminium ions (Al3+) are generated at the anode and they form aluminium hydroxide (Al(OH)3). The

82

subsequent hydration of Al(OH)3 will further produce a variety of macro ions or gelatinous precipitates, which

4

ACS Paragon Plus Environment

Page 5 of 31

Environmental Science & Technology

83

will facilitate the coagulation of colloids such as microorganisms. In addition, gases trapped in coagulated

84

microorganisms will cause them to float to the surface.

85

The NanoGene assay is a bio-assay based on magnetic beads, dual quantum dots as well as DNA hybridization.

86

It is well known for its inhibitor resistance, sensitivity, selectivity, and in-situ compatibility for detecting

87

microorganisms.26-29 It also has an accompanying ozone-based in situ compatible lysis technique.30, 31 More

88

importantly, we have recently demonstrated that the NanoGene assay is as a viable method for detection of

89

Microcystis aeruginosa (M. aeruginosa).32

90

Using M. aeruginosa as the target cyanobacterium, we evaluated the performance of the

91

electrocoagulator with both laboratory and environmental samples (i.e., river water with a range of

92

eutrophication). Cell densities ranged from 1.7 × 105 to 4.1 × 106 and 6.5 × 103 to 6.6 × 107 cells·mL-1,

93

respectively. M. aeruginosa was chosen because the genus Microcystis is abundant and widespread in freshwater

94

bodies.33,

95

measurement were employed to evaluate the pre-concentration efficiency for both varying cell densities and

96

operation duration. The NanoGene assay was used to quantify the microcystin synthetase D, or mcyD gene, in

97

both laboratory and environmental samples that were pre-concentrated by the electrocoagulator. The results were

98

compared to those pre-concentrated by a centrifuge. Zeta potential measurements were also performed to further

99

elucidate the degree of pre-concentration in the environmental samples. In this way, we could establish the

100

suitability of the electrocoagulator as an in situ compatible alternative to the centrifuge for cyanobacterial

101

detection.

34

The absorbance ratio (before and after pre-concentration), as well as the dry cell weight

102 103

EXPERIMENTAL SECTION

104

Design and operation of the electrocoagulator. The electrocoagulator consisted of a pair of electrolysis

105

electrodes, a modified vial, trapping gauze and aspiration outlet (Figure 1a and 1b). The electrodes were 5

ACS Paragon Plus Environment

Environmental Science & Technology

Page 6 of 31

106

commercial off-the-shelf aluminum tubing (KS Aluminum Tubing #8100, Chicago, Illinois, USA) cut into

107

lengths of 60 mm. They were suspended (3.5 mm apart with a silicone spacer) inside a 4-mL modified vial with

108

an aspiration outlet at its base. The overall size of the electrocoagulator is ~2 × 3 × 10 cm with a weight of ~16 g

109

(without battery), and the materials cost less than 3 US dollars.

110

Prior to operation, the trapping gauze (a loosely woven cloth with average pore size > 0.2 mm as shown

111

in the insert of Figure 1b) was secured over the aspiration outlet. During operation, 4.5 VDC (~70 mA, 300 mW)

112

was applied between the electrolysis electrodes to enable electrocoagulation of cyanobacteria in the sample.

113

Note that the electrical power may be supplied by three AA size batteries. Gases generated from the resulting

114

electrolysis were allowed to vent freely. After operation, a syringe was used to manually aspirate the culture

115

broth from the electrocoagulator via the aspiration outlet. In this way, the electrocoagulated cyanobacteria were

116

collected on the trapping gauze and this completed the pre-concentration of the samples. The pre-concentrated

117

cyanobacteria from the gauze were subjected to genomic DNA (gDNA) extraction for the NanoGene assay. The

118

pre-concentrated cyanobacteria from the gauze were subjected to genomic DNA (gDNA) extraction for the

119

NanoGene assay. The captured cyanobacteria were first extracted from the gauze by a tweezer. The remaining

120

cyanobacteria on the gauze was further extracted by soaking it in the lysis buffer (DNA extraction kit). It is

121

important to note that unlike conventional filtration using a fine membrane, a pump with high operating head is

122

not required. In this case, manual aspiration of the culture broth via a syringe sufficed and this was only possible

123

due to the large pore size of the trapping gauze.

124 125

Laboratory sample preparation. The target cyanobacterium M. aeruginosa strain UTEX 2388 was obtained

126

from the Culture Collection of Algae at the University of Texas, Austin, USA. It was inoculated into a 250-mL

127

Erlenmeyer flask containing 100 mL modified Bold 3N medium in which soil water was eliminated. The flask

128

was subsequently incubated at ambient temperature with shaking at 100 rpm to facilitate aeration. Continuous 6

ACS Paragon Plus Environment

Page 7 of 31

Environmental Science & Technology

129

illumination at 20,000 lux (30 W, SL230D, City E.L.G., Incheon, Korea) was also employed. M. aeruginosa

130

culture broth in early exponential phase was used for the laboratory samples in subsequent experiments.

131

The calibration curve (Figure S1) of laboratory sample cell density (cells·mL-1) versus absorbance (as

132

optical density or OD) at 680 nm was obtained via a counting chamber under a light microscope and

133

spectrofluorometer (SpectraMax M2, Molecular Devices, Sunnyvale, USA), respectively.

134 135

Environmental sample sites and sample preparation. Environmental samples were obtained from 2 negative

136

control sites (NC1 and NC2) and 4 study sites (S1, S2, S3 and S4) from the Han River, Korea, in August 2016

137

(Figure 2). Han River is a major river of South Korea that has a river basin of 26,018 km2 of basin and 514.8 km

138

of stems, respectively. Together they supply water to more than 10 million people in the Seoul metropolitan area.

139

The area is also prone to recurring harmful algal blooms.35, 36

140

As shown in Figure 2b and c, the waters in the NC1 and NC2 negative control sites were clear and

141

sedimentary bottom was visible. On the other hand as shown in Figure 2d, e, f and g, the waters of the S1, S2,

142

S3, and S4 study sites were increasingly turbid and a harmful algal bloom was visible in both study sites S3 and

143

S4.

144

Sampling was performed during hot weather with an average water temperature of ~29ºC. No rainfalls

145

was reported during the sampling period. At each sampling site, 2 L of water was drawn from a depth of 30 cm.

146

The water quality data for the environmental negative control and test samples are given in the Supplementary

147

Information (Table S1). The dominant algal species in the samples were identified via microscopic examination

148

(Table 1). The genus Microcystis was predominant in samples S3 and S4.

149

Environmental positive control samples (PC1 and PC2) were prepared by spiking M. aeruginosa culture

150

broth into the NC1 and NC2 samples to achieve final cell densities of 7.4 × 105 cells·mL-1 (equivalent to OD680

151

nm =

0.41) and 6.8 × 105 cells·mL-1 (equivalent to OD680 nm = 0.39), respectively. 7

ACS Paragon Plus Environment

Environmental Science & Technology

Page 8 of 31

152

Cell densities of environmental samples were determined by counting cells with a counting chamber

153

under a light microscope (Figure S2a). The corresponding chlorophyll-a concentration for environmental

154

samples is shown in Figure S2b.

155 156

Comparison of electrocoagulator and centrifuge. The samples (laboratory and environmental) in aliquots of 3

157

mL were first transferred to the modified 4-mL vial of the electrocoagulator. After electrocoagulation and

158

aspiration of the culture broth, the trapping gauze was removed from the electrocoagulator. Subsequently, the

159

electrocoagulated sample on the trapping gauze was dried at 80ºC overnight for dry cell weight measurement. In

160

order to visualize the samples before and after electrocoagulation, additional aliquots of 3 mL were also

161

electrocoagulated in cuvettes separately.

162

Similarly, 3-mL test samples were transferred to the 15-mL centrifuge tubes. The centrifuge (Model

163

1248, LaboGene, Seoul, Korea) was operated at 2,500 rpm (1,224 relative centrifugal force or RCF) for a given

164

duration. The supernatant was then discarded, and the centrifuged pellet in the tubes was also dried at 80ºC

165

overnight.

166

Afterwards, the gram-dry cell weight per liter (g-DCW·L-1) of the sample was determined by weighing

167

the pellet. The pre-concentration efficiency was estimated via the culture broth’s absorbance at 680 nm before

168

(ODt0) and after (ODt1) pre-concentration as follows:

169 170

Pre-concentration Efficiency (%) =

 

× 100



The background absorbance (culture broth only) was subtracted from both ODt0 and ODt1.

171

The experiments were performed at 4.5 V for varying operation durations from 0 to 300 s at a cell

172

density of 4.1 × 105 cells·mL-1, where OD680 nm = ~0.27. They were also performed for varying cell densities

173

from 1.7 × 105 to 4.1 × 106 cells·mL-1, where OD680 nm ranged from 0.08 to 1.1, with an operation duration of

174

180 s. All experiments were performed in biological triplicates unless otherwise stated. Note that uncoagulated 8

ACS Paragon Plus Environment

Page 9 of 31

Environmental Science & Technology

175

laboratory samples were also subjected to culture broth aspiration in the electrocoagulator. This was to establish

176

the inability of the trapping gauze to capture cyanobacteria without electrocoagulation.

177 178

Analysis of pre-concentrated samples via NanoGene assay. Briefly, the NanoGene assay consisted of

179

magnetic beads (MB) and dual quantum dot nanoparticles (QD).26-28, 32 The aminated MB (2 × 107 beads·mL-1,

180

Dynabead M270, Invitrogen, Carlsbad, USA) were coupled with carboxyl QD565 (2 µmole·L-1, Invitrogen,

181

Carlsbad, USA) through an amide bond formation to form the MB-QD565 conjugate. It was further conjugated

182

with the probe DNA (100 µmole·L-1, Bioneer, Daejeon, Korea) to form the MB-QD565-probe DNA complex. The

183

signaling DNA (100 µmole·L-1, Bioneer) was separately immobilized on the surface of QD655 (2 µmole·L-1,

184

Invitrogen, Carlsbad, USA) nanoparticles to form the signaling DNA-QD655 complex. During DNA

185

hybridization, the MB-QD565 complex was tethered to the signaling DNA-QD655 complex via the target mcyD

186

gene through complementary base pairing. After rinsing to remove untethered complexes, the target mcyD gene

187

could be quantified by the normalized fluorescence of QD655 with respect to that of QD565.

188

The pre-concentrated samples (laboratory and environmental) from both the electrocoagulator and

189

centrifuge were first subjected to gDNA extraction. This was performed in duplicate using the NucleoSpin Plant

190

II DNA extraction kit (Macherey-Nagel, Düren, Germany) in accordance with the manufacturer’s instructions.

191

The extracted gDNA was eluted in 100 µL of elution buffer, and duplicate gDNA samples were pooled together.

192

The concentration of the pooled gDNA extracts was spectrophotometrically measured at OD260

193

NanoDropTM 2000 (Thermo Fisher, Wilmington, USA). The gDNA extracts were then denatured at 95ºC for 20

194

min prior to DNA hybridization.

nm

using a

195

DNA hybridization was initiated by adding 5 µL of denatured gDNA extracts to 300 µL of DIG Easy

196

Hybridization buffer (Roche, Basel, Switzerland). The mixture also contained MB-QD565-probe DNA and

197

QD655-signaling DNA complexes. This was followed by the incubation at 37ºC for 15 h with a gentle tilt rotation. 9

ACS Paragon Plus Environment

Environmental Science & Technology

Page 10 of 31

198

After incubation, the sample was rinsed 3 times with 0.1 mole·L-1 phosphate buffer (pH 7.4). The fluorescence

199

intensities of QD565 and QD655 were measured on black 96-microplates (Thermo Fisher Scientific) using a

200

SpectraMax M2 spectrofluorometer with emission wavelengths at 570 and 660 nm, respectively, and an

201

excitation wavelength of 360 nm. Normalized fluorescence was calculated as the ratio of measured fluorescence

202

QD655/QD565.

203

The negative control for the NanoGene assay was in the form of ultrapure deionized water

204

(DNase/RNase/Protease free, Intron Biotechnology, Gyeonggi, Korea) added to the DNA hybridization reaction

205

instead of denatured gDNA.

206

A standard curve for the NanoGene assay (Figure S3) was established using the amplified mcyD gene

207

fragment (297 bp) of M. aeruginosa (mcyD gene copy numbers ranging from 6.5 × 100 to 6.5 × 1010). It was

208

prepared by PCR using the gDNA of M. aeruginosa and the primer set of mcyDF2 and mcyDR2.37 The PCR

209

mixture and thermocycling conditions were described previously in detail.31 The mcyD gene copy numbers were

210

calculated using Avogadro’s number (i.e., 6.022 × 1023 molecules·mole-1) and the DNA weight in Daltons, with

211

the assumption that the average weight of a base pair (bp) is 650 Daltons. The limit of quantification for the

212

NanoGene assay was 7 mcyD gene copy number·mL-1 (Figure S3).

213 214

Zeta potential measurement. Zeta potential measurement was performed by laser Doppler velocimetry using

215

the zeta potential and particle size analyzer ELSZ-2000 (Otsuka Electronics, Osaka, Japan). The zeta potential (ζ)

216

of the environmental samples was measured before and after pre-concentration (by electrocoagulator and

217

centrifuge). Three milliliters of the environmental sample was transferred to the zeta flow cells (Otsuka

218

Electronics) and measured. Electrophoretic analysis was carried out in technical triplicates.

219 220

RESULTS AND DISCUSSION 10

ACS Paragon Plus Environment

Page 11 of 31

Environmental Science & Technology

221

Pre-concentration and NanoGene assay analysis of laboratory samples. Using the electrocoagulator in the

222

absence of applied voltage at the electrolysis electrodes, there was no electrocoagulation of cyanobacteria. As

223

expected, no cyanobacteria were observed on the trapping gauze after aspiration (Figure 3a). This means that in

224

the absence of electrocoagulation, the cyanobacteria in the laboratory samples were sufficiently small to simply

225

pass through the trapping gauze with near zero percent pre-concentration efficiencies for cell densities ranging

226

from 1.4 × 105 to 4.1 × 106 cells·mL-1 (Figure 3b). This is because the size of individual M. aeruginosa cells was

227

too small (~10 to 40 µm) to be captured by the trapping gauze (average pore size > 0.2 mm). However, with

228

operation durations of 60 s and higher, initial visual observations suggested that it was possible to pre-

229

concentrate the laboratory samples for the given range of cell densities (Figure 3c and 3d). A visible increase in

230

the amount of cyanobacterial cells captured by the trapping gauze could be seen with an increase in operation

231

duration (60 – 300 s).

232

With varying operation durations (Figure 4a and 4b), both the pre-concentration efficiency and dry cell

233

weight resulting from the electrocoagulator were slightly lower if not comparable to that of the centrifuge (cell

234

density at 4.1 × 105 cells·mL-1). At an operation duration of 180 s, the electrocoagulator and centrifuge achieved

235

similar pre-concentration efficiencies of 59.1 ± 3.7% and 61.9 ± 2.6% (p-value = 0.342, as determined by a t-test,

236

Table S2), respectively. Their corresponding dry cell weights were also near identical at 0.14 ± 0.02 and 0.14 ±

237

0.05 g-DCW·L-1 (p-value = 1.000, Table S2), respectively. Increasing the operation duration of the

238

electrocoagulator from 180 to 300 s of the electrocoagulator resulted in a marginal increase in pre-concentration

239

efficiency to 62.8 ± 9.9% (~3% increase). Therefore, the nominal operation duration of the electrocoagulator for

240

subsequent experiments was set at 180 s.

241

With varying cell densities (Figure 4c and 4d), both the pre-concentration efficiency and dry cell weight

242

from the electrocoagulator were also slightly lower if not comparable to that of the centrifuge (nominal

243

operation duration of 180 s). For cell densities from 3.2 × 105 to 4.1 × 106 cells·mL-1, the pre-concentration 11

ACS Paragon Plus Environment

Environmental Science & Technology

Page 12 of 31

244

efficiencies of electrocoagulator appeared to be stable at ~60% which was consistent with the earlier experiment.

245

They were slightly lower than that of the centrifuge (~70%).

246

At lower cell densities (2.2 × 105 and 1.7 × 105 cells·mL-1), the pre-concentration efficiencies decreased

247

to 40.4 ± 5.4 and 33.9 ± 0.2%, respectively. This trend was also observed with the centrifuged samples where the

248

pre-concentration efficiencies also decreased to 53.1 ± 0.9 and 37.5 ± 1.8% for these cell densities, respectively.

249

As shown in Figure 4e and 4f, the pre-concentrated samples from the electrocoagulator were analyzed

250

successfully with the NanoGene assay. As expected, the normalized fluorescence and mcyD gene copy number

251

increased with cell density for both the electrocoagulator and centrifuge. At 2.5 × 106 cells·mL-1, pre-

252

concentration via electrocoagulator and centrifuge yielded comparable normalized fluorescence of 4.49 ± 0.46

253

and 5.04 ± 0.51, respectively. The mcyD gene copy numbers from the electrocoagulator and centrifuge were not

254

significantly different (p-value > 0.05, as determined by a t-test, Figure 4f and Table S2).

255 256

Pre-concentration of environmental samples. As expected, using the electrocoagulator and centrifuge (Figure

257

5a and 5b) both yielded pre-concentrated cyanobacteria in PC1 and PC2 (positive control) but not in NC1 and

258

NC2 (negative control). There were also no visible pre-concentrated cyanobacteria obtained from S1 and S2.

259

However, the electrocoagulator appeared to be able to pre-concentrate S3 and S4 as well as, if not more

260

effectively, than the centrifuge. As shown in the dotted boxes in Figure 5a and 5b, S3 formed a well-defined

261

layer after electrocoagulation while remained dispersed after centrifugation. Similarly, the electrocoagulator was

262

able to form a well-defined layer of cyanobacteria in S4. More specifically, the electrocoagulator was able to

263

pre-concentrate S3 (at 57.8 ± 5.1%) with corresponding dry cell weight of 0.33 ± 0.06 g-DCW·L-1 while the

264

centrifuge was unable to do so (Figure 6, p-value ± 30 mV indicate well dispersed particles with no

285

aggregation.42 After pre-concentration by the electrocoagulator and centrifuge, their zeta potentials were reduced

286

as expected. Similarly, the zeta potential for S4 was reduced after pre-concentration, but by a lesser amount than

287

expected. This could be due to the 10-fold dilution that was necessary for zeta potential measurement. With the

288

electrocoagulator, the zeta potential of S3 was reduced significantly from -16.51 ± 1.02 to -5.05 ± 1.05 mV (p13

ACS Paragon Plus Environment

Environmental Science & Technology

Page 14 of 31

289

value = 0.008, Table S4). However, with the centrifuge, it was marginally reduced to -14.32 ± 0.86 mV (p-value

290

= 0.333, Table S4). Therefore the electrocoagulator was able to pre-concentrate S3 more effectively than the

291

centrifuge.

292 293

NanoGene assay analysis of pre-concentrated environmental samples. With reference to Figure 7, M.

294

aeruginosa in the environmental samples pre-concentrated by the electrocoagulator were successfully quantified

295

via the NanoGene assay. The normalized fluorescence for S3, S4, PC1 and PC2 was 3.0 ± 0.7, 4.8 ± 0.6, 4.2 ±

296

0.3 and 4.3 ± 0.3 (Figure 7a), and these corresponded to 3.5 × 103, 5.6 × 106, 1.2 × 105, and 2.0 × 105 mcyD gene

297

copy number (Figure S3 and 7c). More importantly, it demonstrates that the electrocoagulator is also compatible

298

with the NanoGene assay for environmental samples, as it was for the laboratory samples shown earlier.

299

However, with the centrifuge, the normalized fluorescence for S4, PC1 and PC2 was 4.4 ± 0.3, 4.8 ± 0.2 and 4.3

300

± 0.6 (Figure 7b) and these corresponded to 2.6 × 105, 1.2 × 106, and 5.1 × 105 mcyD gene copy number (Figure

301

7d).

302

The viability of the electrocoagulator as an alternative to the centrifuge could be further highlighted by

303

comparing its NanoGene analysis results to the environmental samples’ cell density (Figure S2a) and

304

chlorophyll a concentrations (Figure S2b). The environmental samples’ cell density for S1, S2, S3 and S4 were

305

8.6 × 103, 6.5 × 103, 2.7 × 105 and 6.6 × 107 cells·mL-1. Both the electrocoagulator and centrifuge were not able

306

to pre-concentrate S1 and S2 (cell density less than 104 cells·mL-1). However the electrocoagulator was able to

307

pre-concentrate both S3 and S4. On the other hand, the centrifuge was only able to pre-concentrate S4.

308

The successful NanoGene assay analysis of the environmental samples pre-concentrated by the

309

electrocoagulator verified the compatibility of these technologies. The electrocoagulator has been shown to be

310

an in situ compatible alternative to the centrifuge. More importantly, the electrocoagulator is also small, light

311

weight and low cost. In accordance with the World Health Organization 2003 guidelines for safe recreational 14

ACS Paragon Plus Environment

Page 15 of 31

Environmental Science & Technology

312

water environments, the operational cell density limit of the electrocoagulator at ~105 cells·mL-1 also

313

corresponded to the moderate probability of adverse health effects.43 This means the electrocoagulator can be

314

used on environmentally relevant concentration of cyanobacteria. In other words, the electrocoagulator has

315

advanced the possibility of in situ cyanobacterial detection in eutrophic waters by reducing the size, weight and

316

cost associated with pre-concentration of cyanobacteria.

317 318

ASSOCIATED CONTENT

319

Supporting Information

320

The supporting information is available free of charge on the ACS Publication website. This includes cell

321

density of laboratory cultures (Microcystis aeruginosa), chlorophyll-a concentrations of environmental samples,

322

the calibration curve of the NanoGene assay, and water quality data of environmental test samples.

323 324

ACKNOWLEDGEMENTS

325

This work was supported by the National Research Foundation of Korea (NRF-2017R1A2B4005133 and NRF-

326

2015R1D1A1A01060317).

327

15

ACS Paragon Plus Environment

Environmental Science & Technology

Page 16 of 31

328

REFERENCES

329

(1) Ho, J. C.; Michalak, A. M. Challenges in tracking harmful algal blooms: A synthesis of evidence from Lake

330

Erie. J. Great Lakes Res. 2015, 41, (2), 317-325.

331

(2) Michalak, A. M.; Anderson, E. J.; Beletsky, D.; Boland, S.; Bosch, N. S.; Bridgeman, T. B.; Chaffin, J. D.;

332

Cho, K.; Confesor, R.; Daloglu, I.; DePinto, J. V.; Evans, M. A.; Fahnenstiel, G. L.; He, L. L.; Ho, J. C.; Jenkins,

333

L.; Johengen, T. H.; Kuo, K. C.; LaPorte, E.; Liu, X. J.; McWilliams, M. R.; Moore, M. R.; Posselt, D. J.;

334

Richards, R. P.; Scavia, D.; Steiner, A. L.; Verhamme, E.; Wright, D. M.; Zagorski, M. A. Record-setting algal

335

bloom in Lake Erie caused by agricultural and meteorological trends consistent with expected future conditions.

336

P. Natl. Acad. Sci. USA 2013, 110, (16), 6448-6452.

337

(3) Wilson, E. K. Danger from microcystins in Toledo water unclear. Chem. Eng. News 2014, 92, (32), 9.

338

(4) NOAA, West coast harmful algal bloom, May 2016. https://oceanservice.noaa.gov/news/sep15/westcoast-

339

habs.html

340

(5) NOAA, U. Harmful algal blooms. https://oceanservice.noaa.gov/hazards/hab/

341

(6) Wiegand, C.; Pflugmacher, S. Ecotoxicological effects of selected cyanobacterial secondary metabolites a

342

short review. Toxicol. Appl. Pharm. 2005, 203, (3), 201-218.

343

(7) Paerl, H. W.; Otten, T. G. Harmful cyanobacterial blooms: Causes, consequences, and controls. Microb. Ecol.

344

2013, 65, (4), 995-1010.

345

(8) Landsberg, J. H. The effects of harmful algal blooms on aquatic organisms. Rev. Fish. Sci. 2002, 10, (2), 113-

346

390.

347

(9) Van Dolah, F. M. Effects of harmful algal blooms. Marine mammal research: conservation beyond crisis.

348

Reynolds III J. E., Perrin, W. F., Reeves, R. R., Montgomery, S., Ragen, T. J., Eds.; Johns Hopkins University

349

Press, Baltimore, Maryland 2005, 85-99.

350

(10) Pretty, J. N.; Mason, C. F.; Nedwell, D. B.; Hine, R. E.; Leaf, S.; Dils, R. Environmental costs of freshwater 16

ACS Paragon Plus Environment

Page 17 of 31

Environmental Science & Technology

351

eutrophication in England and Wales. Environ. Sci. Technol. 2003, 37, (2), 201-208.

352

(11) Babel, S.; Takizawa, S. Microfiltration membrane fouling and cake behavior during algal filtration.

353

Desalination 2010, 261, (1-2), 46-51.

354

(12) Babel, S.; Takizawa, S. Chemical pretreatment for reduction of membrane fouling caused by algae.

355

Desalination 2011, 274, (1-3), 171-176.

356

(13) Weinrich, L.; Haas, C. N.; LeChevallier, M. W. Recent advances in measuring and modeling reverse

357

osmosis membrane fouling in seawater desalination: a review. J. Water Reuse Desal. 2013, 3, (2), 85-101.

358

(14) Chorus, I.; Bartram, J. Toxic cyanobacteria in water: A guide to their public health consequences,

359

monitoring and management. Spon Press: 1999.

360

(15) Ouellette, A. J. A.; Handy, S. M.; Wilhelm, S. W. Toxic Microcystis is widespread in Lake Erie: PCR

361

detection of toxin genes and molecular characterization of associated cyanobacterial communities. Microb. Ecol.

362

2006, 51, (2), 154-165.

363

(16) Kaushik, R.; Balasubramanian, R. Methods and approaches used for detection of cyanotoxins in

364

environmental samples: A review. Crit. Rev. Env. Sci. Tec. 2013, 43, (13), 1349-1383.

365

(17) Nübel, U.; Garcia-Pichel, F.; Muyzer, G. PCR primers to amplify 16S rRNA genes from cyanobacteria.

366

Appl. Environ. Microb. 1997, 63, (8), 3327-3332.

367

(18) Spoof, L.; Vesterkvist, P.; Lindholm, T.; Meriluoto, J. Screening for cyanobacterial hepatotoxins,

368

microcystins and nodularin in environmental water samples by reversed-phase liquid chromatography–

369

electrospray ionisation mass spectrometry. J. Chromatogr. A 2003, 1020, (1), 105-119.

370

(19) Bleeke, F.; Quante, G.; Winckelmann, D.; Klöck, G. Effect of voltage and electrode material on

371

electroflocculation of Scenedesmus acuminatus. Bioresour. Bioprocess. 2015, 2, (1), 36.

372

(20) Mollah, M. Y.; Schennach, R.; Parga, J. R.; Cocke, D. L. Electrocoagulation (EC)-science and applications.

373

J. Hazard. Mater. 2001, 84, (1), 29-41. 17

ACS Paragon Plus Environment

Environmental Science & Technology

Page 18 of 31

374

(21) Vandamme, D.; Pontes, S. C.; Goiris, K.; Foubert, I.; Pinoy, L. J.; Muylaert, K. Evaluation of electro-

375

coagulation-flocculation for harvesting marine and freshwater microalgae. Biotechnol. Bioeng. 2011, 108, (10),

376

2320-9.

377

(22) Valero, E.; Alvarez, X.; Cancela, A.; Sanchez, A. Harvesting green algae from eutrophic reservoir by

378

electroflocculation and post-use for biodiesel production. Bioresour. Technol. 2015, 187, 255-62.

379

(23) Alfafara, C. G.; Nakano, K.; Nomura, N.; Igarashi, T.; Matsumura, M. Operating and scale-up factors for

380

the electrolytic removal of algae from eutrophied lakewater. J. Chem. Technol. Biot. 2002, 77, (8), 871-876.

381

(24) Lee, A.K., Lewis, D.M., Ashman, P.J. Harvesting of marine microalgae by electroflocculation: The

382

energetics, plant design, and economics. Applied Energy 2013, 108, 45-53.

383

(25) Vandamme, D.,

384

Coagulation-Flocculation for harvesting marine and freshwater microalgae. Biotechnol. Bioeng. 2011, 108,

385

2320-2329.

386

(26) Kim, G. Y.; Son, A. Development and characterization of a magnetic bead-quantum dot nanoparticles based

387

assay capable of Escherichia coli O157:H7 quantification. Anal. Chim. Acta. 2010, 677, (1), 90-96.

388

(27) Kim, G. Y.; Wang, X. F.; Ahn, H.; Son, A. Gene quantification by the NanoGene assay is resistant to

389

inhibition by humic acids. Environ. Sci. Technol. 2011, 45, (20), 8873-8880.

390

(28) Kim, G. Y.; Wang, X. F.; Son, A. Inhibitor resistance and in situ capability of nanoparticle based gene

391

quantification. J. Environ. Monitor. 2011, 13, (5), 1344-1350.

392

(29) Mitchell, K. A.; Chua, B.; Son, A. Development of first generation in-situ pathogen detection system

393

(Gen1-IPDS) based on NanoGene assay for near real time E. coli O157:H7 detection. Biosens. Bioelectron. 2014,

394

54, 229-236.

395

(30) Lee, E. H.; Chua, B.; Son, A. Micro corona discharge based cell lysis method suitable for inhibitor resistant

396

bacterial sensing systems. Sensor. Actuat. B-Chem. 2015, 216, 17-23.

Pontes, S.C.V., Goiris, K., Foubert, I., Pinoy, L.J.J., Muylaert, K. Evaluation of Electro-

18

ACS Paragon Plus Environment

Page 19 of 31

Environmental Science & Technology

397

(31) Lee, E.-H.; Lim, H. J.; Son, A.; Chua, B. A disposable bacterial lysis cartridge (BLC) suitable for an in situ

398

water-borne pathogen detection system. Analyst 2015, 140, (22), 7776-7783.

399

(32) Lee, E. H.; Cho, K. S.; Son, A. Detection and quantification of toxin-producing Microcystis aeruginosa

400

strain in water by NanoGene assay. J. Microbiol. Biotechnol. 2017, 27, (4), 808-815.

401

(33) Kardinaal, W. E. A.; Janse, I.; Kamst-van Agterveld, M.; Meima, M.; Snoek, J.; Mur, L. R.; Huisman, J.;

402

Zwart, G.; Visser, P. M. Microcystis genotype succession in relation to microcystin concentrations in freshwater

403

lakes. Aquat. Microb. Ecol. 2007, 48, (1), 1-12.

404

(34) Znachor, P.; Jurczak, T.; Komarkova, J.; Jezberova, J.; Mankiewicz, J.; Kastovska, K.; Zapomelova, E.

405

Summer changes in cyanobacterial bloom composition and microcystin concentration in eutrophic Czech

406

reservoirs. Environ. Toxicol. 2006, 21, (3), 236-243.

407

(35) Kim, B. H.; Hwang, S. J.; Park, M. H.; Kim, Y. J. Relationship between cyanobacterial biomass and total

408

microcystin-LR levels in drinking and recreational water. B. Environ. Contam. Tox. 2010, 85, (5), 457-462.

409

(36) Srivastava, A.; Ahn, C. Y.; Asthana, R. K.; Lee, H. G.; Oh, H. M. Status, alert system, and prediction of

410

cyanobacterial bloom in South Korea. BioMed Res. Int. 2015, 2015, 584696.

411

(37) Kaebernick, M.; Neilan, B. A.; Borner, T.; Dittmann, E. Light and the transcriptional response of the

412

microcystin biosynthesis gene cluster. Appl. Environ. Microb. 2000, 66, (8), 3387-92.

413

(38) Dervaux, J.; Mejean, A.; Brunet, P. Irreversible collective migration of cyanobacteria in eutrophic

414

conditions. PloS One 2015, 10, (3), e0120906.

415

(39) Aparicio Medrano, E.; Uittenbogaard, R. E.; van de Wiel, B. J. H.; Dionisio Pires, L. M.; Clercx, H. J. H.

416

An alternative explanation for cyanobacterial scum formation and persistence by oxygenic photosynthesis.

417

Harmful Algae 2016, 60, 27-35.

418

(40) Mendoza-Lera, C.; Federlein, L. L.; Knie, M.; Mutz, M. The algal lift: Buoyancy-mediated sediment

419

transport. Water Resour. Res. 2016, 52, (1), 108-118. 19

ACS Paragon Plus Environment

Environmental Science & Technology

Page 20 of 31

420

(41) Komárek, J. Coccoid and colonial cyanobacteria A2 - WEHR, JOHN D. In Freshwater Algae of North

421

America, Sheath, R. G., Ed. Academic Press: Burlington, 2003; pp 59-116.

422

(42) 4187-82, A. S. D. Zeta potential of colloids in water and wastewater; American Society for Testing and

423

Materials: Conshohocken, PA, 1985.

424

(43) Guidelines for safe recreational water environments; Volume 1 Coastal and fresh waters; World Health

425

Organization: Geneva, Switzerland, 2003; pp. 150, Table 8.3, ISBN 9241545801

426 427

20

ACS Paragon Plus Environment

Page 21 of 31

Environmental Science & Technology

428

FIGURE CAPTIONS

429

Figure 1. (a) Schematic of the portable electrocoagulator for in situ cyanobacterial detection with the NanoGene

430

assay. (b) Photo of the electrocoagulator with insert showing the trapping gauze.

431

Figure 2. (a) Sampling site map. Negative control sites (b) NC1 (c) NC2. Study sites (d) S1 (e) S2 (f) S3 (g) S4.

432

Figure 3. (a) Photo of the trapping gauze when used with the uncoagulated laboratory samples. (b)

433

Experimental plot of the pre-concentration efficiency (%) versus cell density (cells·mL-1) for uncoagulated

434

laboratory samples for varying cell densities (1.4 × 105 to 4.0 × 106 cells·mL-1). (c) Laboratory samples (4.1 ×

435

105 cells·mL-1) pre-concentrated via the electrocoagulator with varying duration 0 – 300 s at 4.5 VDC. (d)

436

Laboratory samples of varying cell densities (1.7 × 105 to 4.1 × 106 cells·mL-1) pre-concentrated via the

437

electrocoagulator at 4.5 VDC for duration of 180 s.

438

Figure 4. Pre-concentration and dry cell weight of laboratory samples via electrocoagulator and centrifuge for

439

(a)(b) varying operation durations at a cell density of 4.1 × 105 cells·mL-1 and (c)(d) varying cell densities with

440

an operation duration of 180 s. (e)(f) NanoGene assay analysis of laboratory samples pre-concentrated using

441

electrocoagulator and centrifuge.

442

Figure 5. Photos of environmental samples before and after pre-concentration using (a) electrocoagulator and (b)

443

centrifuge. Pre-concentration of S3 and S4 (eutrophic water samples) was more effective using the

444

electrocoagulator as compared to the centrifuge (dotted box).

445

Figure 6. (a)(b) Pre-concentration efficiency and (c)(d) dry cell weight of environmental samples via

446

electrocoagulator and centrifuge. ND stands for non-detectable.

447

Figure 7. NanoGene assay analysis of pre-concentrated environmental samples via electrocoagulator and

448

centrifuge. (a)(b) Normalized fluorescence (QD655/QD565) and (c)(d) mcyD gene copy numbers. ND stands for

449

non-detectable.

450 21

ACS Paragon Plus Environment

Environmental Science & Technology

(a)

(b)

Figure 1

22

ACS Paragon Plus Environment

Page 22 of 31

Page 23 of 31

Environmental Science & Technology

(a) Sampling Site Map

(b) NC1

(c) NC2

(d) S1

(e) S2

(f) S3

(g) S4

Figure 2 23

ACS Paragon Plus Environment

Environmental Science & Technology

(a)

(b)

(d)

(c)

Figure 3

24

ACS Paragon Plus Environment

Page 24 of 31

Page 25 of 31

Environmental Science & Technology

(a)

(b)

(c)

(d)

(e)

(f)

Figure 4

25

ACS Paragon Plus Environment

Environmental Science & Technology

(a)

(b)

Figure 5

26

ACS Paragon Plus Environment

Page 26 of 31

Page 27 of 31

Environmental Science & Technology

(a)

(b)

(c)

(d)

Figure 6

27

ACS Paragon Plus Environment

Environmental Science & Technology

(a)

(b)

(c)

(d)

Figure 7

28

ACS Paragon Plus Environment

Page 28 of 31

Page 29 of 31

Environmental Science & Technology

Table 1. Dominant species of cyanobacteria in environmental test samples.

Environmental samples

Dominant algal species

NC1

ND

NC2

ND

S1

Euglena

S2

Scenedesmus, Euglena

S3

Microcystis, Chlamydomonas, Eudonina, Euglena, Spirulina, Anabaena, Closterium, Cosmarium

S4

Microcystis, Chlamydomonas, Euglena, Cosmarium

ND denotes non-detectable

29

ACS Paragon Plus Environment

Environmental Science & Technology

Page 30 of 31

Table 2. Zeta potential measurements of environmental samples before and after pre-concentration (via electrocoagulator and centrifuge).

Environmental samples

Raw water sample (mV)

Electrocoagulator (mV)

Centrifuge (mV)

NC1

6.63 ± 1.45

NA

NA

NC2

6.58 ± 0.21

NA

NA

S1

6.46 ± 0.73

NA

NA

S2

4.94 ± 1.31

NA

NA

S3

-16.51 ± 1.02

-5.05 ± 1.05

-14.32 ± 0.86

S4a

-21.48 ± 1.20

-16.97 ± 2.47

-17.65 ± 1.64

PC1

-32.18 ± 0.03

-19.99 ± 0.29

-20.55 ± 1.38

PC2

-35.09 ± 0.54

-27.83 ± 0.42

-23.54 ± 0.31

Values represent the mean ± SD (n = 3). NA denotes not applicable. S4a sample was ten-fold diluted with distilled water.

30

ACS Paragon Plus Environment

Page 31 of 31

Environmental Science & Technology

Electrocoagulation as pre-concentration technique for cyanobacterial detection by NanoGene assay.

ACS Paragon Plus Environment