A Nontargeted UHPLC-HRMS Metabolomics Pipeline for Metabolite

Dec 19, 2016 - ... the corresponding precolumn CSH C18 1.7 μm VanGuard (Waters, ..... under the auspice of the PREMMi project in the MitoVasc Institu...
0 downloads 0 Views 1MB Size
Subscriber access provided by Fudan University

Article

A non-targeted UHPLC-HRMS metabolomics pipeline for metabolite identification; application to cardiac remote ischemic preconditioning. Judith Kouassi Nzoughet, Cinzia Bocca, Gilles Simard, Delphine Prunier-Mirebeau, Juan Manuel Chao de la Barca, Dominique Bonneau, Vincent Procaccio, Fabrice Prunier, Guy Lenaers, and Pascal Reynier Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.6b04912 • Publication Date (Web): 19 Dec 2016 Downloaded from http://pubs.acs.org on December 23, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 21

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

A non-targeted UHPLC-HRMS metabolomics pipeline for metabolite identification; application to cardiac remote ischemic preconditioning

Judith Kouassi Nzoughet1*, Cinzia Bocca1, Gilles Simard1,2, Delphine Prunier-Mirebeau1,2, Juan Manuel Chao de la Barca1,2, Dominique Bonneau1,2, Vincent Procaccio1,2, Fabrice Prunier3,4, Guy Lenaers1, Pascal Reynier1,2. 1

PREMMi, Pôle de Recherche et d’Enseignement en Médecine Mitochondriale, Institut MITOVASC,

CNRS 6214, INSERM U1083, Université d'Angers, 4 rue Larrey, 49933 Angers cedex 9, France ; 2

Département de Biochimie et Génétique, Centre Hospitalier Universitaire, Angers, France ;

3

Institut MITOVASC, Laboratoire EA3860, Cardioprotection, remodelage et thrombose, Angers,

France ; 4

Département de Cardiologie, Centre Hospitalier Universitaire, Angers, France.

Abstract In recent years, the amount of investigations based on non-targeted metabolomics has increased, although often without thorough assessment of analytical strategies applied to acquire data. Following published guidelines for metabolomics experiments, we report a validated non-targeted metabolomics strategy with pipeline for unequivocal metabolites identification using the MSMLS™ molecule library. We achieved an in-house database containing accurate m/z values, retention times,

isotopic patterns, full MS and MS/MS spectra. A UHPLC-HRMS Q-Exactive™ method was developed and experimental variations were determined within and between 3 experimental days. The extraction efficiency as well as the accuracy, precision, repeatability, and linearity of the method were assessed, the method demonstrating good performances. The methodology was further blindly applied to plasma from Remote Ischemic Pre-Conditioning (RIPC) rats. Samples, previously analyzed by targeted metabolomics using completely different protocol, analytical strategy and platform, were submitted to our analytical pipeline. A combination of multivariate and univariate statistical analyses was employed. Selection of putative biomarkers from OPLS-DA model and S-plot was combined to jack-knife confidence intervals, metabolites VIP values and univariate statistics. Only variables with 1 ACS Paragon Plus Environment

Analytical Chemistry

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 21

strong model contribution and highly statistical reliability were selected as discriminated metabolites. Three biomarkers identified by the previous targeted metabolomics study were found in the current work, in addition to three novel metabolites, emphasizing the efficiency of the current methodology and its ability to identify new biomarkers of clinical interest, in a single sequence. The biomarkers were identified to level 1 according to the Metabolomics Standard Initiative and confirmed by both RPLC and HILIC-HRMS.

INTRODUCTION Metabolomics is defined as the comprehensive analysis of low-molecular-weight metabolites, typically 0.05

D (10) = 0.145, p>0.05

Glycine

D (10) = 0.133, p>0.05

D (10) = 0.144, p>0.05

Kynurenine

D (10) = 0.195, p>0.05

D (10) = 0.180, p>0.05

Ornithine

D (10) = 0.27, p