Subscriber access provided by UNIVERSITY OF TOLEDO LIBRARIES
Applications of Polymer, Composite, and Coating Materials
A Novel Membrane Detector Based on Smart Nanogels for Ultrasensitive Detection of Trace Threat Substances Pei-Jie Yan, Fan He, Wei Wang, Shi-Yuan Zhang, Lei Zhang, Ming Li, Zhuang Liu, Xiao-Jie Ju, Rui Xie, and Liang-Yin Chu ACS Appl. Mater. Interfaces, Just Accepted Manuscript • DOI: 10.1021/acsami.8b12615 • Publication Date (Web): 27 Sep 2018 Downloaded from http://pubs.acs.org on September 28, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
A Novel Membrane Detector Based on Smart Nanogels for Ultrasensitive Detection of Trace Threat Substances Pei-Jie Yan,†,§ Fan He,†,§ Wei Wang,*,†,‡ Shi-Yuan Zhang,† Lei Zhang,† Ming Li,† Zhuang Liu,†,‡ Xiao-Jie Ju,†,‡ Rui Xie,†,‡ and Liang-Yin Chu*,†,‡
†
School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, P.
R. China ‡
State Key Laboratory of Polymer Materials Engineering, Sichuan University,
Chengdu, Sichuan 610065, P. R. China
KEYWORDS:
crown ether; host−guest complexation; membrane detectors; smart
nanogels; ultrasensitive detection
1 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ABSTRACT:
Page 2 of 40
A novel membrane detector is developed by a facile strategy
combining commercialized membrane and smart nanogels, for ultrasensitive and highly-selective real-time detection of trace threat substances.
Based on nanogel
filtration and polydopamine adhesion, the membrane detector is fabricated by simply immobilizing smart nanogels onto the multiple pores of a commercialized membrane as the nanosensors and nanovalves. Pb2+-responsive
This is demonstrated by incorporating
poly(N-isopropylacrylamide-co-acryloylamidobenzo-18-crown-6)
nanogels in the straight pores of a commercialized polycarbonate membrane for ultrasensitive and highly-selective real-time detection of trace Pb2+.
When
selectively recognizing the Pb2+ in solution, the smart nanogels in the membrane pores swell, which lead to trans-membrane flux change.
Quantitative detection of
Pb2+ concentration can be achieved by simply measuring the flow rate of the trans-membrane flow. Due to the multiple nanochannels of nanogel-immobilized pores in the membrane for Pb2+-sensing and flux regulating, ultrasensitive and highly-selective real-time detection of trace Pb2+ with concentration as low as 10-10 mol L-1 can be achieved.
The nanogel-immobilized membrane detector offers a
flexible platform to create versatile new membrane detectors by incorporating diverse smart nanogels for ultrasensitive and highly-selective real-time detection of different trace threat substances.
2 ACS Paragon Plus Environment
Page 3 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
INTRODUCTION Detection of trace chemical/biological substances, which are harmful to human health even with ultralow concentration, is critical for various applications such as diagnosis of diseases1,2 and protection of environment.3,4
For example, due to the easy
accumulation in human body, Pb2+ with even trace amount can cause renal and neurological damages as well as brain disorders, especially for children.
Thus,
required by the World Health Organization (WHO), Pb2+ concentration ([Pb2+]) in drinking water must be less than 4.83 × 10-8 mol L-1.
Thus, real-time detection of
these trace threat substances with ultra-sensitivity and high-selectivity is highly required.
For such detection, the key challenge is the efficient conversion and
amplification of the signal of trace threat substances into simply detectable output. Traditional techniques such as inductively-coupled plasma spectroscopy,5-8 atomic absorption spectroscopy,9-12 electrochemical method,13-16 and fluorescent probes,17-19 can convert the signals of trace threat substances into electrical and optical signals for detection.
However, these techniques suffer from expensive detection apparatus,
time-consuming sample preparation, and troublesome operation and analysis process. Moreover, although electrochemical methods are easy and low-cost, electrodes modified with inorganic materials usually cannot achieve highly-selective detection of threat substances such as Pb2+, due to the severe interference from other metal ions;14 while those modified with enzymes usually suffer from high-cost and poor store ability.13,16 Compared with the above-mentioned techniques, responsive polymeric materials that can change their physical/chemical properties in response to specific
3 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 4 of 40
stimuli,20-22 enable flexible conversion of the stimulus signals into diverse output signals.
Therefore, the responsive polymeric materials provide good flexibility in
signal conversion and amplification to develop advanced detection systems for detecting trace threat substances. Typically, several detection techniques have been developed based on responsive polymeric materials to convert the signal of trace threat substances into electrical, optical or flow-rate readouts for detection of such substances.
For electrical
detection, field-effect transistor based on smart hydrogel can convert glucose concentration signals into electrical signals, due to the glucose-responsive change of hydrogel volume and surface charge, for detecting glucose (~2.8×10-3 mol L-1).23 For optical detection, smart hydrogel gratings can change their diffraction efficiency upon responsive volume changes for detecting Pb2+ (~10-6 mol L-1),24 human immunoglobulin-G (~6×10-6 mol L-1),25 and glucose (~2.3×10-5 mol L-1).26 When incorporated with fluorescent molecules and photonic crystals, smart microgels and hydrogels can convert their responsive volume changes into fluorescent intensity change,27-29 and diffraction peak shift,30,31 for detecting Pb2+ (~10-9 mol L-1),32,33 glucose (~2.5×10-3 mol L-1)34, Hg2+ (~10-8 mol L-1),32,35 DNA (~10-9 mol L-1)36 and 3-pyridinecarboxamid.37
Alternatively, smart hydrogel microcantilevers can bend
when recognizing specific ions, and then change the position of laser deflection for sensitive detection of heavy metal ions such as Pb2+ (~10-6 mol L-1),38 and CrO42(~10-10 mol L-1).39
However, although these techniques enable sensitive detection of
different substances, they usually require troublesome process for device fabrication
4 ACS Paragon Plus Environment
Page 5 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
and sample preparation, and sophisticated analyzing protocols, which restrict their applications for real-time detection.
The detection systems based on flow rate
measurement allow easy connection of the detector with solution-flowing pipeline, which provide an efficient way for real-time online detection of trace threat substances.
For example, microchip with smart microgel valve allows
[Pb2+]-dependent volume change to adjust the flowing area in microchannel for flow-rate change.
The microchip can be incorporated with water pipeline for
sensitive and real-time online detection of Pb2+ (10-9 mol L-1).40
However, the
microchip fabrication still requires troublesome and skillful manual assembly.
By
grafting Pb2+-responsive polymers in the pores of commercialized membranes, simple detection systems can be constructed for adjusting the trans-membrane flux for detecting Pb2+ (10-6 mol L-1).41
However, although the membrane detection system
provides a simple strategy for Pb2+ detection, it still suffers from limited control of the plasma-grafting process for fabricating the grafting membrane, and limited sensitivity for detecting trace Pb2+ at the level required by WHO (4.83×10-8 mol L-1).
Therefore,
development of a facile and efficient strategy to fabricate simple detection system for ultrasensitive and highly-selective real-time detection of trace threat substances is still highly desired. Here, a novel membrane detector, based on simple integration of commercialized porous membrane with smart nanogels, is developed for ultrasensitive and highly-selective real-time detection of trace threat substances.
The straight pores of
the membrane provide multiple nanochannels for flowing fluids.
5 ACS Paragon Plus Environment
The smart
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 6 of 40
nanogels, that can respond to specific stimulus, are anchored onto the pore nanochannels by simple filtration and polydopamine (PDA) adhesion (Figure 1a-c). This can create nanogel-immobilized membrane detection systems for ultrasensitive and highly-selective detection.
We demonstrate this by simply incorporating
Pb2+-responsive nanogels in the straight pores of commercialized polycarbonate (PC) membrane as nanosensors and nanovalves for ultrasensitive and highly-selective real-time
detection
of
trace
Pb2+.
The
nanogels
are
consisting
of
poly(N-isopropylacrylamide-co-acryloylamidobenzo-18-crown-6) (poly(NIPAM-co-AAB18C6)) (PNB) networks, with crown ether units for Pb2+ recognition and poly(N-isopropylacrylamide) (PNIPAM) backbone for actuation. When the crown ether groups recognize Pb2+ and form stable 18-crown-6/Pb2+ host-guest complexes, the volume phase transition temperature (VPTT1) shifts to a higher temperature (VPTT2) (Figure 1d).
When operated at an optimal detection
temperature (Td) between VPTT1 and VPTT2, the nanogels in the membrane pores can isothermally swell when [Pb2+] increases (Figure 1e,1f), leading to trans-membrane flux change for ultrasensitive [Pb2+] detection.
Since the nanogel-immobilized pores
of the membrane provide multiple nanochannels for Pb2+-sensing and flux regulating, ultrasensitive and highly-selective real-time detection of trace Pb2+ with concentration as low as 10-10 mol L-1 can be achieved.
The membrane detector based on
immobilized smart nanogels provides a versatile and advanced detection platform for ultrasensitive and highly-selective real-time detection of trace threat substances.
6 ACS Paragon Plus Environment
Page 7 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
EXPERIMENTAL SECTION Materials.
N-Isopropylacrylamide (NIPAM) (98%, TCI) was recrystallized using
a hexane/acetone mixture.
4’-Amino-benzo-18-crown-6 (AB18C6) was synthesized
from 4’-nitro-benzo-18-crown-6 (98%, TCI) based on our previous work.42 Ammonium persulfate, N,N’-methylene-bis-bisacrylamide, sodium dodecyl sulfate, acrylic acid (AAc) and tris(hydroxymethyl)aminomethane (Tris) were purchased from Chengdu Kelong Chemicals. hydrochloride Sigma-Aldrich.
(EDC)
and
1-(3-(Dimethylamino)propyl)-3-ethyl carbodiimide dopamine-hydrochloride
were
purchased
from
Deionized water (18.2 MΩ, 25 °C) from a Milli-Q Plus water
purification system (Millipore) was used throughout this work. Fabrication of PNB Nanogels.
PNB nanogels were prepared by first
synthesizing poly(N-isopropylacrylamide-co-acrylic acid) (P(NIPAM-co-AAc)) (PNA) nanogels (Figure S1), followed by AB18C6 modification (Figure S2).
First, for
preparing the PNA nanogels, monomers NIPAM (2.26g) and AAc (0.6171g), initiator ammonium persulfate (0.0651g), crosslinker N,N’-methylene-bis-acrylamide (0.044g) and surfactant sodium dodecyl sulfate (0.0329g) were dissolved in 250 mL deionized water.
The solution was then bubbled with nitrogen for 30 min to remove the
dissolved oxygen.
Next, the solution was heated to 70 oC and reacted for 4 h under
nitrogen atmosphere.
After the reaction, the solution was cooled down to room
temperature, followed with filtration and dialysis to obtain purified suspension of PNA nanogels.
7 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 40
Second, PNB nanogels were prepared by modifying the PNA nanogels with AB18C6 via condensation reaction using EDC as dehydration catalysts, based on our previous work.42
Briefly, an aqueous solution containing PNA nanogels and
AB18C6 was mixed with another aqueous solution containing EDC, and then reacted at 4 oC under stirring and nitrogen atmosphere for 24 h.
After the reaction, the
solution was dialyzed against deionized water for 1 week to obtain suspension of purified PNB nanogels. A piece of commercialized
Preparation of Nanogel-Immobilized Membranes.
PC membrane (ATTP, Millipore) (Diameter = 47 mm) with pore diameters of 800 nm (PC-800) was used for immobilization of the PNB nanogels via filtration and PDA-based adhesion. Meanwhile, another piece of PC membrane, with same size, but with pore diameters of 220 nm (PC-220) was attached on the bottom of PC-800 membrane to hold up the nanogels (Figure 1a).
For nanogel immobilization, the
combined two pieces of PC membranes were fixed inside an ultrafiltration cup (MSC050, MOSU).
Aqueous suspension of PNB nanogels (2 mg mL-1) was filtrated
through the combined membranes with pressure of 0.1 MPa at 50 oC (Figure 1b). After that, the PC-800 membrane was detached from the PC-220 membrane and cooled down to 10 oC to let the PNB nanogels swell.
Then, the PC-800 membrane
was placed in Tris solution (10 mL, pH=8.5) containing dopamine (DA) (2 mg mL-1) and shaken for 2 h at 25 oC for immobilization of PNB nanogels (Figure 1c).
At last,
the nanogel-immobilized PC membrane was further washed with deionized water to remove un-immobilized PNB nanogels and unreacted DA.
8 ACS Paragon Plus Environment
Page 9 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Construction of Membrane Detector for Pb2+-Detection.
To construct the
Pb2+-detection system, the nanogel-immobilized PC membrane was incorporated into a filter and then enveloped by a heating jacket for temperature control.
A
microfluidic control system (MFCS-FLEX 3C, Fluigent), coupled with a buffer tank, was used to inject the solution into the membrane detector at a constant pressure. The flow rate of flows that passed through the nanogel-immobilized membrane was measured by a flowmeter (FLU_L, Fluigent) coupled with a computer for data analysis (Figure 2). Chemical Composition and Morphological Characterization of PNB Nanogels and Nanogel-Immobilized Membranes.
The chemical composition of PNB
nanogels was characterized by Fourier transform infrared spectrometry (FT-IR) (IR Prestige-21, Shimadzu).
The sample for FT-IR characterization was freeze-dried and
tested by KBr disk technique.
The morphology of PNB nanogels in dried state was
observed by atomic force microscope (AFM) (MM8, BRUKER).
The sample for
AFM characterization was dried at room temperature. The morphologies of PC-800 membrane and nanogel-immobilized PC membrane were observed by scanning electron microscope (SEM) (TM3030, HITACHI).
The
membrane samples were treated with liquid nitrogen and then fractured mechanically for cross-section observation.
All the membrane samples for SEM observation were
sputter-coated with gold for 120 s. Study on the Pb2+-Responsive Properties of PNB Nanogels.
To investigate the
Pb2+-responsive properties of PNB nanogels at different temperatures, their
9 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
[Pb2+]-dependent diameter changes in aqueous solutions at temperatures ranging from 13 oC to 64 oC were measured by dynamic light scattering (DLS) (Zetasizer Nano ZS90, Malvern).
The highly diluted nanogels-containing dispersion was equilibrated
for 180 s at each predetermined temperature.
Similarly, the Pb2+-dependent diameter
changes of PDA-coated PNB nanogels at different temperatures were measured by DLS, to investigate the influence of dopamine on the Pb2+-responsive property of PNB nanogels.
For preparing the PDA-coated PNB nanogels, briefly, dried PNB
nanogels (0.003 g) were dispersed in Tris solution (3 mL) with pH = 8.5, followed with dissolution of DA (2 mg mL-1).
The PNB-nanogel-containing solution was
shaken for 2 h to modify the PNB nanogels with a PDA coating, and finally purified by centrifugation at 10000 rpm.
Moreover, to study the effect of DA on the
Pb2+-responsive property of PNB nanogels, absorption spectra of DA-containing solution, Pb2+-containing solution, and aqueous solutions containing both DA and Pb2+ were also tested by UV-vis spectrometer (UV-1700, Shimadzu), with a wavelength range from 200 nm to 350 nm.
The concentration of DA in the aqueous
solutions was 0.25 mg L-1, and the [Pb2+] was varied from 10-9 mol L-1 to 10-6 mol L-1. Study on the Optimal Detection Temperature and Sensitivity of Membrane Detector.
The optimal detection temperature (Td) of the membrane detector for
ultrasensitive Pb2+-detection was determined by studying the effects of temperature and [Pb2+] on the trans-membrane flux.
The temperature, at which the most
significant change of trans-membrane flux is obtained, is defined as the optimal detection temperature. Briefly, Pb2+-containing solution with a certain [Pb2+] was
10 ACS Paragon Plus Environment
Page 10 of 40
Page 11 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
supplied into the membrane detector under a constant pressure of 0.015 MPa by the microfluidic control system.
The [Pb2+] in the Pb2+-containing solution was varied
from 10-10 mol L-1 to 10-6 mol L-1.
With a fixed [Pb2+], the flows were equilibrated
for 20 min at each predetermined temperature, and the equilibrated flow rate of flows that went through the membrane at different temperatures in the range from 30 oC to 50 oC was measured by the flowmeter. Study on the Repeatability and Selectivity of Membrane Detector.
To
investigate the performance of the membrane detector for highly-selective [Pb2+] detection, their trans-membrane flux in aqueous solutions containing interfering ions at optimal detection temperature was measured.
Each of the solutions contains one
type of different interfering ions, including K+, Na+, Ba2+, Ca2+, Mg2+, and Sr2+.
The
concentration of the interfering ion in each solution was 10-6 mol L-1. Since the Pb2+-detection was based the reversible volume phase transitions of PNB nanogels for flux control, to evaluate the repeated Pb2+-detection performance, the flow rate changes of membrane detector during repeated swelling/shrinking upon heating (50 oC) and cooling (10 oC) cycles were measured.
RESULTS AND DISCUSSION Choice of Materials. Among the materials usually used for specific detection of Pb2+ (Table S1), the 18-crown-6 units can provide crown ether cavities to selectively recognize specific metal ions and form stable host-guest complexes.
Due to the
largest complex constant between 18-crown-6 and Pb2+ as compared to other metal
11 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 40
ions, here 18-crown-6 is employed as the sensor for Pb2+ recognition.
PNIPAM, a
thermo-responsive polymer that allows volume phase transition when changing its hydrophilic/hydrophobic equilibrium, is used as the actuator.
When combining
PNIPAM with 18-crown-6 by using AAc via first co-polymerization and then condensation reaction, PNB nanogels that can isothermally swell in response to Pb2+ can be obtained as the nanosensors and nanovalves.
Commercialized low-cost PC
membrane with regular straight pores, is used to provide multiple microchannels for incorporating the PNB nanogels.
Combination of the PC membrane and PNB
nanogels based on the adhesion property of PDA can simply produce the nanogel-immobilized membrane for detection of Pb2+. Preparation of Pb2+-Responsive PNB Nanogels.
Pb2+-responsive PNB nanogels
used as the Pb2+-responsive sensors in the membrane detector are synthesized by precipitation copolymerization of NIPAM and AAc, followed with AB18C6 modification via condensation reaction.
Figure 3a shows the FT-IR spectra of PNB
nanogels, with PNIPAM nanogels and PNA nanogels as the control groups.
For
PNIPAM nanogels, the peak at 1670 cm-1 is attributed to the carbonyl groups, while the ones at 1387 cm-1 and 1375 cm-1 are attributed to the isopropyl groups.
Both
peaks from the isopropyl groups can be observed for PNA nanogels and PNB nanogels, confirming the existence of PNIPAM backbones in PNA and PNB nanogels. For PNA nanogels, the peak at 1710 cm-1 is attributed to the carboxylic groups.
This
peak disappears after modification of PNA nanogels with AB18C6, indicating the conversion of the carboxylic groups via the condensation reaction.
12 ACS Paragon Plus Environment
Meanwhile, for
Page 13 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
PNB nanogels, the peaks at 1516 cm-1 and 1130 cm-1 are attributed to the C=C skeletal stretching vibration of phenyl ring and the C-O-C asymmetric stretching vibration of R-O-R', respectively.
The results confirm the successful incorporation
of 18-crown-6 groups in the PNA nanogels for preparing PNB nanogels.
Moreover,
as shown in the AFM images (Figure 3b), the PNB nanogels in dried state exhibit uniform spherical shapes, with an average diameter of 450 nm. Pb2+-Responsive Properties of PNB and PDA-Coated PNB Nanogels.
The
PNB nanogels enable volume phase transitions in response to [Pb2+] changes. Meanwhile, due to the thermo-responsive PNIPAM backbone, the PNB nanogels show different Pb2+-responsive volume phase transition behaviors at different temperatures.
As shown in Figure 4a, when placed in aqueous solution with
[Pb2+]=0 mol L-1, the diameter of PNB nanogels decreases from 831.4 nm to 330.9 nm, with increasing temperature from 13 oC to 64 oC.
Similar volume shrinking
behaviors can be obtained upon increasing temperature when placing the PNB nanogels in Pb2+-containing solutions with fixed [Pb2+].
Meanwhile, with a fixed
temperature, the diameter of PNB nanogels increases with increasing [Pb2+] from 0 mol L-1, 10-4 mol L-1, to 10-3 mol L-1, indicating the excellent Pb2+-responsive volume phase transition behavior.
Such Pb2+-induced volume changes of PNB nanogels
allow regulation of the pore size when they are incorporated into the membrane pores, for converting the [Pb2+] signal into detectable flux changes. To evaluate the Pb2+-induced volume changes of PNB nanogels at each temperature, Pb2+-induced swelling ratio (R1), defined by Equation (1), is used.
13 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
R1 =
DPb2+
Page 14 of 40
(1)
Dwater
where DPb 2+ and Dwater are respectively the diameters of PNB nanogels or PDA-coated PNB nanogels in Pb2+-containing solution and pure water at the same temperature.
As shown in Figure 4b, for PNB nanogels in Pb2+-containing solutions
with [Pb2+] of 10-3 mol L-1 and 10-4 mol L-1, both of the R1 values first increase with increasing temperature from 13 oC to 37 oC, and then decrease with increasing temperature from 37 oC to 64 oC.
The maximum R1 value at 37 oC means that, at 37
o
C, the PNB nanogels in water can achieve largest volume change when responding to
[Pb2+] changes. To decorate the PNB nanogels onto the membrane pore surface, DA is utilized as the binding agents for the nanogel immobilization.
The versatile adhesion property
of DA on diverse materials during self-polymerization,43-45 ensures the tight binding between PNB nanogels and the pore surface of PC membrane. the Pb2+-responsive property of PNB nanogels is investigated.
Effect of the DA on Firstly, the absorption
spectra of DA-containing solution, Pb2+-containing solutions and DA/Pb2+ mixed solutions are tested by UV-vis spectrometer.
As shown in Figure S3, there are
absorption peaks for DA-containing solution, but no absorption peaks appear for the Pb2+-containing solutions with different [Pb2+].
Meanwhile, for the DA/Pb2+ mixed
solutions with different [Pb2+], no additional absorption peaks appear as compared with the one of DA solution, indicating no influence of DA on the complexation between the crown ether and Pb2+.
14 ACS Paragon Plus Environment
Page 15 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Figure 5a shows the excellent volume phase transitions of PDA-coated PNB nanogels in response to temperature and [Pb2+].
In pure water, with increasing
temperature from 13 oC to 64 oC, the diameter of PNB nanogels decreases from 634.2 nm to 343.2 nm.
As compared with PNB nanogels, due to the coating of the PDA
layer on the nanogel surface, the PDA-coated PNB nanogels show a slightly decreased diameter at each temperature.
Meanwhile, with fixed temperature, the
diameter of PDA-coated PNB nanogels increases when increasing [Pb2+] from 0 mol L-1, 10-4 mol L-1, to 10-3 mol L-1, indicating excellent Pb2+-responsive volume changes. Moreover, for PNB nanogels in solutions with [Pb2+] of 10-3 mol L-1 and 10-4 mol L-1, both of their R1 values first increase and then decrease with increasing temperature, showing a maximum value at 40 oC (Figure 5b).
As compared with that of the PNB
nanogels (Figure 4b), such an increase in the optimal detection temperature is resulted from the VPTT shift caused by the incorporation of hydrophilic PDA units in the crosslinked hydrogel networks.46
The excellent Pb2+-responsive volume phase
transition behaviors of the PDA-coated PNB nanogels ensure the good performance of the immobilized nanogels for regulating pore size for flux control. Construction of Nanogel-Immobilized Membrane Detector.
To construct the
nanogel-immobilized membrane detector, the PNB nanogels, used as Pb2+-sensors are incorporated into the commercialized PC membrane.
Typically, for the nanogel
decoration, two pieces of PC membranes (Diameter = 47 mm), one with pore diameter of 800 nm (PC-800) and another one with pore diameter of 220 nm (PC-220) are combined together.
As shown in Figure 6a and 6b, the PC-800 membrane
15 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
exhibits porous structures with straight pores.
Page 16 of 40
By filtrating the swollen PNB
nanogels through the PC-800 membrane at a temperature lower than VPTT, the PNB nanogels can be well remained in the pores of PC-800 membrane, due to the holding up of nanogels by the PC-220 membrane (Figure 1a,b).
After the PDA coating for
nanogel adhesion, the PC-800 membrane is decorated with PNB nanogels (Figure 1c). The SEM images in Figure 6c-f confirm the successful immobilization of PNB nanogels on the top surface (Figure 6c,d) and pore surface (Figure 6e,f) of the PC-800 membranes after PDA coating.
To construct the membrane detector for Pb2+
detection (Figure 2), the nanogel-immobilized membrane is incorporated into a filter covered with a heating jacket, and then integrated with a microfluidic control system, a flowmeter, and a buffer tank. Nanogel-Immobilized Membrane Detector for Ultrasensitive Detection of Trace Pb2+.
The ability of nanogel-immobilized membrane detector for
ultrasensitive detection is based on volume phase transitions of PNB nanogels in response to different [Pb2+] values.
Such [Pb2+]-dependent volume changes allow
manipulation of the size of membrane pores to convert [Pb2+] signals into simply-detectable trans-membrane flux changes.
When flowed with Pb2+-containing
solution, the PNB nanogels in the membrane detector swell due to the complexation between the crown ether groups and Pb2+.
This swelling of nanogels decreases the
pore size and leads to reduced trans-membrane flux.
For detection of [Pb2+], first,
the trans-membrane fluxes (J) at different temperatures and [Pb2+] are measured to determine the optimal detection temperature (Figure 7a).
16 ACS Paragon Plus Environment
With increasing
Page 17 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
temperature, the values of J at different [Pb2+] all increase due to the thermo-induced shrinking of PDA-coated PNB nanogels.
Meanwhile, with fixed temperature, the
value of J decreases with increasing [Pb2+] from 0 mol L-1 to 10-6 mol L-1, due to the Pb2+-induced swelling of PDA-coated PNB nanogels.
The Pb2+-induced change of J
is evaluated by using Pb2+-induced flux-changing ratio (R2), which is defined by Equation (2):
R2 = where
J Pb 2+
and
J water
J Pb2+
(2)
J water
are the trans-membrane flux of nanogel-immobilized
membrane in Pb2+-containing solution with a certain [Pb2+] and in pure water at the same temperature, respectively. The R2 first decreases and then increases with increasing temperature from 30 oC to 50 oC, showing a minimum value at 40 oC (Figure 7b).
This tendency means that, at
40 oC, the [Pb2+] change can lead to largest decrease of trans-membrane flux.
This
result is coincident with that the PDA-coated PNB nanogels can achieve largest Pb2+-induced volume swelling at 40 oC (Figure 5b).
Moreover, at 40 oC, even in
Pb2+-containing solution with [Pb2+] as low as 10-10 mol L-1, the membrane detector can still exhibit an obvious Pb2+-induced reduce of trans-membrane flux with R2 = 0.88.
Such a flux reduce can be easily detected by the flowmeter, indicating that the
[Pb2+] detection limit is as low as 10-10 mol L-1.
Based on the [Pb2+]-dependent R2
values at 40 oC (Figure 7b), the quantitative relationship between the R2 value and [Pb2+] can be obtained (Figure 7c) and described by Equation (3): Pb 2 + = 72.83e −4.74 R2
17 ACS Paragon Plus Environment
(3)
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 18 of 40
Thus, the [Pb2+] value can be simply calculated by using R2 values based on the measured trans-membrane flux of the Pb2+-containing solution and pure water at 40 o
C.
Thus, the membrane detector enables highly-sensitive detection of trace Pb2+.
Based on these results, for Pb2+ detection, aqueous solution without Pb2+ can be first injected through the membrane detector via a pump at 40 oC, followed with injection of Pb2+-containing sample solution.
Then, the value of flow rate change after the
solution switch can be simply measured by a flowmeter, and then easily converted into [Pb2+] values based on the simple and quantitative relationship between flow rate changes and [Pb2+] for Pb2+ detection.
The [Pb2+] values based on flow rate changes
can be directly read by using self-made and low-cost App on smart phone, requiring no professional data analysis, as we demonstrated in our previous work.40 Moreover, the membrane detector based on flowing solutions can be directly connected into the solution-flowing pipelines such as water pipelines for real-time online detection of Pb2+ pollution.
Nanogel-Immobilized Membrane Detector for Highly-Selective Detection of Trace Pb2+.
Based on the high selectivity of PNB nanogels for recognizing Pb2+,40
the nanogel-immobilized membrane detector enables highly-selective Pb2+ detection. The highly-selective Pb2+ detection is investigated by using aqueous solutions, each containing one type of interfering ions for trans-membrane flux measurement.
To
evaluate the trans-membrane flux changes induced by different ions, the ion-induced flux change (∆J), defined by Equation (4), is used.
∆J = Jwater - Jion
18 ACS Paragon Plus Environment
(4)
Page 19 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
where Jwater and Jion are the trans-membrane flux of water (210 µL min-1) and ion-containing solution with ion concentration of 10-6 mol L-1, respectively.
The
Jwater and Jion are all measured at 40 oC under a constant pressure of 0.015 MPa.
As
shown in Figure 7d, the ∆J induced by each of the ions, including K+, Na+, Ba2+, Ca2+, Mg2+, and Sr2+, are all less than 9 µL min-1.
Meanwhile, the ∆J induced by Pb2+ is
96.5 µL min-1, which is much larger than those induced by other ions, due to the higher binding constant between 18-crown-6 groups and Pb2+ as compared with other ions.47
Generally, the formation and stability of the complexes between 18-crown-6
groups and the metal ions are dominated by the size/shape matching between the cavity of 18-crown-6 groups and metal ions.
According to the literature,48 the order
of complex constant of 18-crown-6 with metal ions is: Pb2+ > Ba2+ > other ions (such as K+, Na+, Ba2+, Ca2+, Mg2+, and Sr2+); thus, the swelling extent of PNB nanogels as well as the ∆J induced by Ba2+, are larger than other interference ions, but still negligible as compared with Pb2+.
All the results show the high selectivity of the
membrane detector for Pb2+-detection.
Moreover, for more complex samples that
contain various pollutants such as ions, microparticles, oil, proteins and microorganisms, pre-purification of the sample solutions by methods such as filtration is required to avoid blocking of the membrane pores by pollutants.
Nanogel-Immobilized Membrane Detector for Repeatable Detection of Trace Pb2+.
For Pb2+ detection, the conversion of [Pb2+] to simply-detectable flux changes
is achieved by using the responsive volume phase transitions of PNB nanogels for controlling the size of membrane pores.
To demonstrate such a control on the pore
19 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 20 of 40
size for flux regulation, here the reversible swelling/shrinking volume changes of PNB nanogels in the membrane detector is simply achieved by using heating (50 oC) and cooling (10 oC) cycles (Figure 8a).
Under a constant pressure of 0.015 MPa, the
J values of pure water show repeated changes during the heating/cooling cycles. The ratio of water flux at 50 oC to that at 10 oC remains ~40 within eight heating/cooling cycles, indicating the firm immobilization of PNB nanogels in the membrane detector and their excellent performance for flux control.
Since such
reversible volume changes can also be realized when responding to different [Pb2+] changes,40 the membrane detector can show excellent performance for repeated [Pb2+] detection.
Moreover, to demonstrate the good reproducibility of our strategy for
fabricating the membrane detector, the performances of nanogel-immobilized membrane detectors fabricated from different batches for detection of trace Pb2+ are also studied.
As shown in Figure 8b, at 40 oC, the membranes fabricated from three
batches all exhibit a similar flux at [Pb2+] with a fixed value.
These results indicate
good repeatability of the membrane detector for detecting trace Pb2+, and good reproducibility of our strategy for fabricating the membrane detector.
CONCLUSIONS In summary, a novel membrane detector is created by a facile strategy combining commercialized
membranes
and
smart
nanogels,
highly-selective detection of trace threat substances.
for
ultrasensitive
and
The membrane detector is
fabricated by simply immobilizing smart nanogels onto the multiple nanochannels of
20 ACS Paragon Plus Environment
Page 21 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
pores in a commercialized membrane based on filtration and PDA adhesion.
This is
demonstrated by incorporating Pb2+-responsive nanogels in the straight pores of commercialized PC membrane for ultrasensitive and highly-selective real-time detection of trace Pb2+, with detection limit as low as 10-10 mol L-1.
Future study
needs to focus on the detection performances and anti-fouling properties of the membrane detector for more complex real samples, and on the size match between nanogels and pores for further improving the responsive flow rate change as well as the detection performances.
Based on the diverse stimuli-responsive materials for
creating smart nanogels,42,49-53 the nanogel-immobilized membrane detector, together with our simple fabrication strategy, provides a flexible platform for creating versatile new
smart-nanogel-immobilized
membrane
detectors
for
ultrasensitive
highly-selective detection of different trace threat substances.
and
The membrane
detectors show great power for myriad applications such as disease treatment and environment protection.
AUTHOR INFORMATION Corresponding Authors *E-mail:
[email protected] (L.-Y. C.)
*E-mail:
[email protected] (W. W.) Author Contributions The manuscript was written through contributions of all authors. given approval to the final version of the manuscript. 21 ACS Paragon Plus Environment
All authors have
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
§
P.-J. Y. and F. H. contributed equally to this work.
Notes The authors declare no competing financial interest.
ACKNOWLEDGMENTS
The authors gratefully acknowledge support from the National Natural Science Foundation of China (21490582, 21576167), the Program for Changjiang Scholars and Innovative Research Team in University (IRT15R48) and the State Key Laboratory of Polymer Materials Engineering (sklpme2014-1-01).
REFERENCES
(1) Kosaka, P. M.; Pini, V.; Ruz, J. J.; da Silva, R. A.; Gonzalez, M. U.; Ramos, D.; Calleja, M.; Tamayo, J., Detection of Cancer Biomarkers in Serum Using a Hybrid Mechanical and Optoplasmonic Nanosensor. Nat. Nanotechnol. 2014, 9, 1047-1053.
(2) Huber, F.; Lang, H. P.; Backmann, N.; Rimoldi, D.; Gerber, C., Direct Detection of a BRAF Mutation in Total RNA from Melanoma Cells Using Cantilever Arrays. Nat. Nanotechnol. 2013, 8, 125-129.
22 ACS Paragon Plus Environment
Page 22 of 40
Page 23 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
(3) Giannoukos, S.; Brkic, B.; Taylor, S.; Marshall, A.; Verbeck, G. F., Chemical Sniffing Instrumentation for Security Applications. Chem. Rev. 2016, 116, 8146-8172.
(4) Duong, T. Q.; Kim, J. S., Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens. Chem. Rev. 2010, 110, 6280-6301.
(5) Ashoka, S.; Peake, B. M.; Bremner, G.; Hageman, K. J.; Reid, M. R., Comparison of Digestion Methods for ICP-MS Determination of Trace Elements in Fish Tissues. Anal. Chim. Acta 2009, 653, 191-199.
(6) Verma, R.; Gupta, B. D., Detection of Heavy Metal Ions in Contaminated Water by Surface Plasmon Resonance based Optical Fibre Sensor Using Conducting Polymer and Chitosan. Food Chem. 2015, 166, 568-575.
(7) Zhao, L.; Zhong, S.; Fang, K.; Qian, Z.; Chen, J., Determination of Cadmium(II), Cobalt(II), Nickel(II), Lead(II), Zinc(II), and Copper(II) in Water Samples Using Dual-Cloud Point Extraction and Inductively Coupled Plasma Emission Spectrometry. J. Hazard. Mater. 2012, 239-240, 206-212.
(8) Otero-Romani, J.; Moreda-Pineiro, A.; Bermejo-Barrera, P.; Martin-Esteban, A., Inductively Coupled Plasma-Optical Emission Spectrometry/Mass Spectrometry for the Determination of Cu, Ni, Pb and Zn in Seawater after Ionic Imprinted Polymer based Solid Phase Extraction. Talanta 2009, 79, 723-729.
23 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 24 of 40
(9) Pohl, P., Determination of Metal Content in Honey by Atomic Absorption and Emission Spectrometries. Trac-Trend. Anal. Chem. 2009, 28, 117-128.
(10) Mahmoud, M. E.; Kenawy, I. M. M.; Hafez, M. A. H.; Lashein, R. R., Removal, Preconcentration and Determination of Trace Heavy Metal Ions in Water Samples by AAS via Chemically Modified Silica Gel N-(1-carboxy-6-hydroxy) Benzylidenepropylamine Ion Exchanger. Desalination 2010, 250, 62-70.
(11) Tarley, C. R.; Andrade, F. N.; de Oliveira, F. M.; Corazza, M. Z.; de Azevedo, L. F.;
Segatelli,
M.
G.,
Synthesis
and
Application
of
Imprinted
Polyvinylimidazole-Silica Hybrid Copolymer for Pb2+ Determination by Flow-injection Thermospray Flame Furnace Atomic Absorption Spectrometry. Anal. Chim. Acta 2011, 703, 145-151.
(12) Shah, F.; Kazi, T. G.; Naeemullah; Afridi, H. I.; Soylak, M., Temperature Controlled
Ionic
Liquid-Dispersive
Liquid
Phase
Microextraction
for
Determination of Trace Lead Level in Blood Samples Prior to Analysis by Flame Atomic Absorption Spectrometry with Multivariate Optimization. Microchem. J.
2012, 101, 5-10.
(13) Pelossof, G.; Tel-Vered, R.; Willner, I., Amplified Surface Plasmon Resonance and Electrochemical Detection of Pb2+ Ions Using the Pb2+-Dependent DNAzyme and Hemin/G-quadruplex as a Label. Anal. Chem. 2012, 84, 3703-3709.
24 ACS Paragon Plus Environment
Page 25 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
(14) Cui, L.; Wu, J.; Ju, H., Electrochemical Sensing of Heavy Metal Ions with Inorganic, Organic and Bio-Materials. Biosens. Bioelectron. 2015, 63, 276-286.
(15) Gumpu, M. B.; Sethuraman, S.; Krishnan, U. M.; Rayappan, J. B. B., A Review on Detection of Heavy Metal Ions in Water - An Electrochemical Approach. Sensor. Actuat. B-Chem. 2015, 213, 515-533.
(16) Tang, S.; Tong, P.; Li, H.; Tang, J.; Zhang, L., Ultrasensitive Electrochemical Detection of Pb2+ based on Rolling Circle Amplification and Quantum Dots Tagging. Biosens. Bioelectron. 2013, 42, 608-611.
(17) Joseph, K. A.; Dave, N.; Liu, J., Electrostatically Directed Visual Fluorescence Response of DNA-Functionalized Monolithic Hydrogels for Highly Sensitive Hg2+ Detection. ACS Appl. Mater. Interfaces 2011, 3, 733-739.
(18) Li, F.; Pei, H.; Wang, L.; Lu, J.; Gao, J.; Jiang, B.; Zhao, X.; Fan, C., Nanomaterial-based Fluorescent DNA Analysis: a Comparative Study of the Quenching Effects of Graphene Oxide, Carbon Nanotubes, and Gold Nanoparticles. Adv. Funct. Mater. 2013, 23, 4140-4148. (19) Marbella, L.; Serli-Mitasev, B.; Basu, P., Development of a Fluorescent Pb2+ Sensor. Angew. Chem., Int. Ed. 2009, 48, 3996-3998.
(20) Ito, T.; Sato, Y.; Takeo Yamaguchi, A.; Nakao, S., Response Mechanism of a Molecular Recognition ion Gating Membrane. Macromolecules 2004, 37, 3407-3414.
25 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
(21) Chu, L. Y.; Yamaguchi, T.; Nakao, S., A Molecular Recognition Microcapsule for Environmental Stimuli-Responsive Controlled-Release. Adv. Mater. 2002, 14, 386-389.
(22) Liu, Z.; Wang, W.; Xie, R.; Ju, X. J.; Chu, L. Y., Stimuli-Responsive Smart Gating Membranes. Chem. Soc. Rev. 2016, 45, 460-475.
(23) Matsumoto, A.; Sato, N.; Sakata, T.; Yoshida, R.; Kataoka, K.; Miyahara, Y., Chemical-to-Electrical-Signal Transduction Synchronized with Smart Gel Volume Phase Transition. Adv. Mater. 2009, 21, 4372-4378.
(24) Wang, X.; Ye, G.; Wang, X., Hydrogel Diffraction Gratings Functionalized with Ccrown Ether for Heavy Metal Ion Detection. Sensor. Actuat. B-Chem. 2014, 193, 413-419.
(25) Ye, G.; Yang, C.; Wang, X., Sensing Diffraction Gratings of Antigen-Responsive Hydrogel for Human Immunoglobulin-G Detection. Macromol. Rapid Commun.
2010, 31, 1332-1336.
(26) Ye, G.; Wang, X., Glucose Sensing through Diffraction Grating of Hydrogel Bearing Phenylboronic Acid Groups. Biosens. Bioelectron. 2010, 26, 772-777.
(27) Kim, H. N.; Ren, W. X.; Kim, J. S.; Yoon, J., Fluorescent and Colorimetric Sensors for Detection of Lead, Cadmium, and Mercury Ions. Chem. Soc. Rev.
2012, 41, 3210-3244.
26 ACS Paragon Plus Environment
Page 26 of 40
Page 27 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
(28) Geng, S.; Lin, S. M.; Li, N. B.; Luo, H. Q., Polyethylene Glycol Capped ZnO Quantum Dots as a Fluorescent Probe for Determining Copper(II) Ion. Sensor. Actuat. B-Chem. 2017, 253, 137-143.
(29) Zhang, J. F.; Zhou, Y.; Yoon, J.; Kim, J. S., Recent Progress in Fluorescent and Colorimetric Chemosensors for Detection of Precious Metal Ions (Silver, Gold and Platinum Ions). Chem. Soc. Rev. 2011, 40, 3416-3429.
(30) Goponenko, A. V.; Asher, S. A., Modeling of Stimulated Hydrogel Volume Changes in Photonic Crystal Pb2+ Sensing Materials. J. Am. Chem. Soc. 2005, 127, 10753-10759. (31) Reese, C. E.; Asher, S. A., Photonic Crystal Optrode Sensor for Detection of Pb2+ in High Ionic Strength Environments. Anal. Chem. 2003, 75, 3915-3918.
(32) Ye, B. F.; Zhao, Y. J.; Cheng, Y.; Li, T. T.; Xie, Z. Y.; Zhao, X. W.; Gu, Z. Z., Colorimetric Photonic Hydrogel Aptasensor for the Screening of Heavy Metal Ions. Nanoscale 2012, 4, 5998-6003.
(33) Hong, W.; Li, W.; Hu, X.; Zhao, B.; Zhang, F.; Zhang, D., Highly Sensitive Colorimetric Sensing for Heavy Metal Ions by Strong Polyelectrolyte Photonic Hydrogels. J. Mater. Chem. 2011, 21, 17193-17201.
(34) Gamsey, S.; J. T. S.; And, R. A. W.; Singaram, B., Continuous Glucose Detection Using Boronic Acid-Substituted Viologens in Fluorescent Hydrogels: Linker Effects and Extension to Fiber Optics. Langmuir 2006, 22, 9067-9074.
27 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
(35) Neupane, L. N.; Oh, E. T.; Park, H. J.; Lee, K. H., Selective and Sensitive Detection of Heavy Metal Ions in 100% Aqueous Solution and Cells with a Fluorescence Chemosensor based on Peptide Using Aggregation-Induced Emission. Anal. Chem. 2016, 88, 3333-3340.
(36) Zhao, Y.; Zhao, X.; Tang, B.; Xu, W.; Li, J.; Hu, J.; Gu, Z., Quantum-Dot-Tagged Bioresponsive Hydrogel Suspension Array for Multiplex Label-Free DNA Detection. Adv. Funct. Mater. 2010, 20, 976-982.
(37) Yuan, Y.; Li, Z.; Liu, Y.; Gao, J.; Pan, Z.; Liu, Y., Hydrogel Photonic Sensor for the Detection of 3-Pyridinecarboxamide. Chem. Eur. J. 2012, 18, 303-309. (38) Liu, K.; Ji, H. F., Detection of Pb2+ Using a Hydrogel Swelling Microcantilever Sensor. Anal. Sci. 2004, 75, 9-11. (39) Zhang, Y.; Ji, H. F.; Brown, G. M.; Thundat, T., Detection of CrO42- Using a Hydrogel Swelling Microcantilever Sensor. Anal. Chem. 2003, 75, 4773-4777.
(40) Lin, S.; Wang, W.; Ju, X. J.; Xie, R.; Liu, Z.; Yu, H. R.; Zhang, C.; Chu, L. Y., Ultrasensitive Microchip based on Smart Microgel for Real-Time Online Detection of Trace Threat Analytes. Proc. Natl. Acad. Sci. USA. 2016, 113, 2023-2028.
(41) Liu, Z.; Luo, F.; Ju, X. J.; Xie, R.; Sun, Y. M.; Wang, W.; Chu, L. Y., Gating Membranes for Water Treatment: Detection and Removal of Trace Pb2+ Ions
28 ACS Paragon Plus Environment
Page 28 of 40
Page 29 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
based on Molecular Recognition and Polymer Phase Transition. J. Mater. Chem. A 2013, 1, 9659-9671.
(42) Jiang, M. Y.; Ju, X. J.; Fang, L.; Liu, Z.; Yu, H. R.; Jiang, L.; Wang, W.; Xie, R.; Chen, Q; Chu, L. Y., A Novel, Smart Microsphere with K+ Induced Shrinking and Aggregating Properties based on a Responsive Host-Guest System. ACS Appl. Mater. Interfaces 2014, 6, 19405-19415.
(43) Lee, H.; Dellatore, S. M.; Miller, W. M.; Messersmith, P. B., Mussel-Inspired Surface Chemistry for Multifunctional Coatings. Science 2007, 318, 426-430.
(44) Yang, H. C.; Luo, J.; Lv, Y.; Shen, P.; Xu, Z. K., Surface Engineering of Polymer Membranes via Mussel-Inspired Chemistry. J. Membr. Sci. 2015, 483, 42-59.
(45) Li, Z. L.; Wang, W.; Li, M.; Zhang, M. J.; Tang, M. J.; Su, Y. Y.; Liu, Z.; Ju, X. J.; Xie, R.; Chu, L. Y., Facile Fabrication of Bubble-Propelled Micromotors Carrying Nanocatalysts for Water Remediation. Ind. Eng. Chem. Res. 2018, 57, 4562-4570.
(46) Teodorescu, M.; Andrei, M.; Turturicǎ, G.; Stǎnescu, P. O.; Zaharia, A.; Sârbu, A., Novel Thermoreversible Injectable Hydrogel Formulations based on Sodium Alginate and Poly(N-Isopropylacrylamide). Int. J. Polymer. Mater. 2015, 64, 763-771.
(47) Izatt, R. M.; Terry, R. E.; Haymore, B. L.; Hansen, L. D.; Dalley, N. K.; Ayondet, A. G.; Christensen, J. J., Calorimetric Titration Study of the Interaction of
29 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 30 of 40
Several Uni- and Bivalent Cations with 15-crown-5, 18-crown-6, and Two Isomers of Dicyclohexo-18-crown-6 in Aqueous Solution at 25 oC and µ=0.1. J. Am. Chem. Soc. 1976, 98, 7620-7626.
(48) Zhang, B.; Ju, X. J.; Xie, R.; Liu, Z.; Pi, S. W.; Chu, L. Y., Comprehensive Effects
of
Metal
Ions
on
Responsive
Characteristics
of
P(NIPAM-co-B18C6Am). J. Phys. Chem. B, 2012, 116, 5527-5536.
(49) Wei, J.; Ju, X. J.; Zou, X. Y.; Xie, R.; Wang, W.; Liu, Y. M.; Chu, L. Y., Multi-Stimulil-Responsive Microcapsules for Adjustable Controlled-Release. Adv. Funct. Mater. 2014, 24, 3312-3323.
(50) Lu, Y.; Aimetti, A. A.; Langer, R.; Gu, Z., Bioresponsive Materials. Nat. Rev. Mater. 2016, 2, 16075.
(51) Mou, C. L.; Wang, W.; Li, Z. L.; Ju, X. J.; Xie, R.; Deng, N. N.; Wei, J.; Liu, Z.; Chu, L. Y., Trojan-Horse-like Stimuli-Responsive Microcapsules. Adv. Sci. 2018, 5, 1700960.
(52) Wang, W.; Zhang, M. J.; Chu, L. Y., Functional Polymeric Microparticles Engineered from Controllable Microfluidic Emulsions. Accounts Chem. Res.
2014, 47, 373-384.
(53) Zhang, M. J.; Wang, W.; Xie, R.; Ju, X. J.; Liu, L.; Gu, Y. Y.; Chu, L. Y., Microfluidic
Fabrication
of
Monodisperse
30 ACS Paragon Plus Environment
Microcapsules
for
Page 31 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Glucose-Responsive at Physiological Temperature. Soft Matter 2013, 9, 4150-4159.
31 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 32 of 40
Figures
Figure 1. Schematic illustration of fabrication of nanogel-immobilized membrane for Pb2+ detection.
(a-c) Decoration of PNB nanogels onto the PC-800 membrane via
filtration (a,b) and PDA-based immobilization (c).
(d) Isothermal swelling and
shrinking changes of PNB nanogels in response to [Pb2+] changes.
(e,f)
Pb2+-induced flux changes based on the Pb2+-responsive swelling (e) and shrinking (f) of PNB nanogels in the pores of PC-800 membrane.
32 ACS Paragon Plus Environment
Page 33 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Figure 2. Set-up of the Pb2+-detecting membrane detector based on the nanogel-immobilized membrane.
33 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Figure 3. Compositional and morphological characterization of PNB nanogels. FT-IR spectra of PNIPAM, PNA and PNB nanogels. nanogels.
Page 34 of 40
(a)
(b) AFM image of dried PNB
The scale bar is 1 µm.
34 ACS Paragon Plus Environment
Page 35 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Figure 4. Pb2+-responsive volume phase transitions of PNB nanogels.
(a)
Temperature-dependent diameter changes of PNB nanogels in pure water and Pb2+-containing solutions with different [Pb2+].
(b) Temperature-dependent R1
changes of PNB nanogels in Pb2+-containing solutions with different [Pb2+].
35 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 36 of 40
Figure 5. Pb2+-responsive volume phase transitions of PDA-coated PNB nanogels. (a) Temperature-dependent diameter changes of PDA-coated PNB nanogels in pure water
and
Pb2+-containing
solutions
with
different
[Pb2+].
(b)
Temperature-dependent R1 changes of PDA-coated PNB nanogels in Pb2+-containing solutions with different [Pb2+].
36 ACS Paragon Plus Environment
Page 37 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Figure 6. Morphological characterization of blank and nanogel-immobilized PC-800 membrane.
(a,b) SEM images of the top surface (a) and cross-section (b) of blank
PC-800 membrane.
(c-f) SEM images (c,e) and magnified SEM images (d,f) of the
top surface (c,d) and cross-section (e,f) of nanogel-immobilized PC-800 membrane. Scale bars are 5 µm in (a-c, e) and 2 µm in (d, f).
37 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 38 of 40
Figure 7. Nanogel-immobilized membrane detector for ultrasensitive and highly-selective detection of trace Pb2+.
(a) Effects of temperature and [Pb2+] on the
trans-membrane flux changes of the membrane detector.
(b) Temperature-dependent
R2 changes of the membrane detector at different [Pb2+]. relationship between [Pb2+] and R2.
(c) Quantitative
(d) Flux changes of the membrane detector
induced by different ions at 40 oC.
38 ACS Paragon Plus Environment
Page 39 of 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
ACS Applied Materials & Interfaces
Figure 8. Nanogel-immobilized membrane detector for repeated Pb2+ detection.
(a)
Flux changes of the membrane detector upon repeated heating/cooling.
(b)
[Pb2+]-dependent trans-membrane fluxes of membrane detectors constructed from different batches.
39 ACS Paragon Plus Environment
ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Graphic for TOC
40 ACS Paragon Plus Environment
Page 40 of 40