A Wearable Transient Pressure Sensor Made with MXene Nanosheets

Jan 18, 2019 - Veyrat, Jordan, Zimmermann, Gay, Watanabe, Taniguchi, Sellier, and Sacépé. 0 (0),. Abstract: We report on the evolution of the cohere...
0 downloads 0 Views 1MB Size
Subscriber access provided by TULANE UNIVERSITY

Communication

A Wearable Transient Pressure Sensor Made with MXene Nanosheets for Sensitive Broad-Range Human-Machine Interfacing Ying Guo, Mengjuan Zhong, Zhiwei Fang, Pengbo Wan, and Guihua Yu Nano Lett., Just Accepted Manuscript • DOI: 10.1021/acs.nanolett.8b04514 • Publication Date (Web): 18 Jan 2019 Downloaded from http://pubs.acs.org on January 19, 2019

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

A Wearable Transient Pressure Sensor Made with MXene Nanosheets for Sensitive Broad-Range Human-Machine Interfacing Ying Guo,†,§ Mengjuan Zhong,† Zhiwei Fang, ‡ Pengbo Wan,*,† and Guihua Yu*,‡ †State

Key Laboratory of Organic-Inorganic Composites, Beijing University of

Chemical Technology, Beijing 100029, China ‡Materials

Science and Engineering Program and Department of Mechanical

Engineering, The University of Texas at Austin, TX 78712, USA §State

Key Laboratory of Chemical Resource Engineering, Beijing University

of Chemical Technology, Beijing 100029, P.R. China KEYWORDS:

flexible

electronic

sensors,

electronic

skins,

MXene,

degradability, broad-range healthcare monitoring ABSTRACT Flexible and degradable pressure sensors have received tremendous attention for potential use in transient electronic skins, flexible displays, and intelligent robotics due to their portability, real-time sensing performance, flexibility, and decreased electronic waste and environmental impact. However, it remains a critical challenge to simultaneously achieve a high sensitivity, broad sensing range (up to 30 kPa), fast response, long-term

ACS Paragon Plus Environment 1

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 28

durability, and robust environmental degradability to achieve full-scale biomonitoring

and

decreased

electronic

waste.

MXenes,

which

are

two-dimensional layered structures with a large specific surface area and high conductivity, are widely employed in electrochemical energy devices. Here, we present a highly sensitive, flexible and degradable pressure sensor fabricated by sandwiching porous MXene-impregnated tissue paper between a biodegradable polylactic acid (PLA) thin sheet and an interdigitated electrode-coated PLA thin sheet. The flexible pressure sensor exhibits high sensitivity with a low detection limit (10.2 Pa), broad range (up to 30 kPa), fast response (11 ms), low power consumption (10-8 W), great reproducibility over 10000 cycles, and excellent degradability. It can also be used to predict the potential health status of patients and act as an electronic skin (E-skin) for mapping tactile stimuli, suggesting potential in personal healthcare monitoring, clinical diagnosis, and next-generation artificial skins.

Flexible wearable pressure sensors have attracted considerable attention for various potential applications, including electronic skins1,2, human-machine interfaces3,4, flexible touchable displays5, and intelligent robotics, due to their reliable portability, excellent real-time electrical sensing performance regarding personal activities without interrupting or restricting the motions of the individual wearing the sensor, high integration potential, flexibility and ease of processing. To date, most of the reported pressure sensors have

ACS Paragon Plus Environment 2

Page 3 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

realized

excellent

sensing

performance

by

utilizing

various

sensing

mechanisms, including piezoresistive6-10, capacitive11-13, piezoelectric14-16, and triboelectric effects17,18. Among these mechanisms, flexible piezoresistive pressure sensors, consisting of compatible substrates and a flexible conductive material network, have attracted considerable attention due to a reliable piezoelectric effect being enabled by a force-induced current or resistance change. Other advantages include a simple device assembly, relatively low energy consumption, and excellent sensing sensitivity. However, it is difficult to simultaneously obtain a high sensitivity, broad sensing range, long-term durability, and robust reproducibility to satisfy the requirements for full-scale medical monitoring from small deformations (such as breathing, pulse and vocalization) to large movements (such as arm bending, coughing, and joint motion). Flexible wearable pressure sensors are mostly prepared from a combination of

conducting

nanostructured

material

networks

and

flexible

plastic

substrates. Recently, remarkable nanostructured materials have been used to fabricate various flexible pressure sensors due to their excellent mechanical flexibility and electrical conductivity, such as metal nanoparticles19, carbon nanotubes20,21,

metal

nanowires,

polymers

nanofibers22,

carbonized

nanofibers, graphene23, and their nanocomposites24-26. MXenes, which are two-dimensional layered nanomaterials with large specific surface areas, excellent

hydrophilicity

and

high

conductivity,

are

widely

used

in

ACS Paragon Plus Environment 3

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 28

electrochemical energy storage27, transparent electrode materials28, and nanocomposites29,30. Despite their large specific surface area and strong conductivity, hierarchical MXene composite meshes have rarely been employed

in

fabricating

flexible

pressure

sensors31,32.

Moreover,

microstructured plastic or rubber substrates and thermosetting resins without easy environmental degradability have been used for the preparation of wearable pressure sensors via a laborious and complicated fabrication process. High electronic wastes (e-wastes) (25×106 ton/year) and serious environmental pollution resulting from their released toxic materials have occurred with the increasing demand for consumer electronic devices due to the designed survivability and slow degradation of the devices in the environment33. Thus, there is an urgent need for the development of degradable electronic devices that use naturally degradable sensing materials and substrates that degrade into biologically and environmentally friendly end products on limited timescales while also exceeding desirable device lifetimes. Recently, some “transient” electronic components have been developed with solvent-soluble active and passive materials, such as transistors34-36, batteries37,38, energy harvesters39, and functional circuits for power

harvesting40.

Most

biodegradable

polymers

(e.g.,

silk41,

polylactic-co-glycolic acid (PLGA)42, polycaprolactone (PCL)43 and polylactic acid (PLA)44) are used as substrates or encapsulation layers. It is still a substantial challenge to develop "transient" pressure sensors with a high

ACS Paragon Plus Environment 4

Page 5 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

sensitivity, broad sensing range, environmental degradability, fast response and reliable compatibility. Here, we demonstrate a facile approach for the simple, cost-effective, and versatile fabrication of a flexible wearable transient pressure sensor with MXene nanosheets for highly sensitive broad-range human-machine interfacing (Figure 1). The flexible wearable transient pressure sensor is fabricated

by

impregnating

MXene

nanosheets

into

tissue

papers

(MXene/tissue paper) with a porous structure, recyclability, low cost, degradability and reliable elasticity. A biodegradable PLA sheet and a PLA sheet patterned with an interdigitated conductive electrode are then sandwiched between them. The as-prepared wearable pressure sensor achieves a high sensitivity, low detection limit (10.2 Pa), ultrasensitive loading sensing of a sugar granule (2.3 mg), fast response (11 ms), low power consumption (10-8 W), excellent reproducibility over 10000 cycles and is biodegradable The fabricated pressure sensor could be attached to human skin to perform various broad-range medical monitoring tasks, ranging from small deformations to large movements. The pressure sensor is also able to input Morse code by touching the sensor device surface; this capability could be used to predict the potential health status of patients with early-stage Parkinson’s disease, which was simulated using imitated static tremors. Additionally, the sensor arrays were successfully assembled and used to detect various tactile signals and map spatial pressure distributions,

ACS Paragon Plus Environment 5

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 28

suggesting potential applications in personal healthcare biomonitoring, clinical diagnosis, artificial intelligence, and next-generation artificial skins and wearable electronics.

Figure 1. (a) Schematic illustration of the fabrication procedure of flexible wearable transient pressure sensors with MXene nanosheets. (b) TEM image of the MXene nanosheets. (c) AFM image of MXene nanosheets deposited on a mica plate. (d) SEM image of MXene/tissue paper. (e) The enlarged SEM image of an MXene/tissue paper fiber. (f-g) Photographs of the flexible wearable transient pressure sensor. Figure 1a shows the facile device fabrication process. First, conductive MXene (Ti3C2Tx) nanosheets were obtained from the selective etching of the

ACS Paragon Plus Environment 6

Page 7 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

precursor (Figure S1a). The resulting colloidal solution contained MXene sheets with a lateral size of a few micrometers (Figure S1). Through the well-exfoliated ultrathin MXene sheets, the pores of the anodized aluminum oxide membrane were observed (Figure S1d). The associated size histogram (Figure S1e) indicates a mean lateral length () of 1.54 m, and a clear slice structure is observed in the transmission electron microscope (TEM) image (Figure 1b). The thickness of the flake is approximately 4.2 nm according to the atomic force microscopy (AFM) measurement (Figure 1c), which is in good agreement with a previous report45. The unique 2D structure endows the MXene sheets with the capability to assemble into flexible functional

films

or

to

serve

as

nanofillers

for

functional

polymer

nanocomposites. The successful preparation of MXene nanosheets is confirmed by the shift of the (002) X-ray diffraction peak to a smaller angle and the greatly weakened peak at 39°, as shown in Figure S2a. A Raman spectrum of a typical sample is shown in Figure S2b; the peaks at 198 and 717 cm−1 are assigned to the out-of-plane vibrations of Ti and C atoms, respectively, while the peaks at 284, 366, and 624 cm−1 are assigned to the in-plane (shear) modes of Ti, C, and surface functional group atoms, respectively46. The XPS spectra (Figure S2c) indicate that the samples are mainly composed of C, Ti, O, and F. Thin MXene/tissue paper films (0.6 cm×0.8 cm rectangles) with different sheet resistances were obtained from the impregnation of MXene nanosheets by

ACS Paragon Plus Environment 7

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 28

immersing the tissue papers into MXene nanosheet solutions with different concentrations (Figure S3). The sheet resistance decreased from 56.5 MΩ/□ to 6.7 kΩ/ □ for the different concentrations of MXene solution used when preparing the MXene/tissue paper films. A concentration of 2.5 mg/mL was selected as the optimal concentration due to the low sensor energy consumption, low sheet resistance, low cost and reproducibility. The MXene/tissue paper was then placed onto the PLA film with interdigitated electrodes (Figure S4), and this was followed by covering it with a thin sheet of black PLA (Figure 1a). By comparing the scanning electron microscopy (SEM) images of the tissue paper in Figure S5a and S5b, the uniform coating of MXene onto degradable porous tissue paper can be observed in Figure 1d and 1e, which shows SEM images of the MXene/tissue paper. Figure S6 shows the lateral view of the whole device from the cross-section of the overall device. Figure 1f and 1g show the optical images of the assembled device with excellent flexibility. The sensing mechanism is due to tunable changes in contact resistance between the porous MXene/tissue paper and the interdigitated electrodes under external pressure (Figure 1a and Figure S7). External pressure will cause a small compressive deformation of the porous soft MXene/tissue paper, leading to more contact and more conductive paths between the MXene and the interdigitated electrodes (Figure S7) under a fixed voltage of 0.01 V, thus causing an increase in the current. Upon unloading, both the PLA

ACS Paragon Plus Environment 8

Page 9 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

and MXene/tissue paper returned to their original shapes, reducing the contact area between the interdigitated electrodes and MXene and resulting in a reduced current (Figure S7).

Figure 2. (a) Current response to increased pressures under loading and unloading. Inset: the current response in the low-pressure range of 89−536 Pa. (b) Current response to increased pressures under loading and unloading at 23, 44, and 89 Pa. (c) Sensing sensitivity of the flexible pressure sensor to pressure. (d) The durability test under a pressure of 3036 Pa. Inset: the detailed durability performance under a pressure of 3036 Pa. (e) Response time of the pressure sensor. (f) I–V curves of the sensor with various applied pressures. To ensure the mechanical flexibility and durability of the interdigitated electrodes on the PLA film, a serpentine electrode printed on the PLA film with a length of 20 mm was bent 1000 times to a radius of curvature of 5 mm with a linear motor, and the conductivity of the electrode did not obviously change (Figure S8). To evaluate the sensing performance of the pressure sensors,

ACS Paragon Plus Environment 9

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 10 of 28

the flexible pressure sensor was connected with an electrical sensing analyzer by conductive copper wires, which were placed onto a force meter platform for real-time sensing recording. The sensitivity (S) of the pressure sensors is defined as S=δ(∆I/I0)/δP, where ΔI is the relative change in the current, I0 is the current of the sensor without loading and P is the pressure under loading. Figure 2a-b shows representative current plots (∆I/I0) of the sensor under different external pressures. Figure S9 shows the sensing performance with the standard deviation for Figure 2a. Five samples were measured to obtain the average and representative sensing performance with a standard deviation of approximately 5%. Under each pressure, the sensor has a good, stable sensing response and a large range of pressure detection (23 Pa-30 kPa). As shown in Figure 2c, the sensitivities of the flexible pressure sensors are composed of three regions: S1 in the low-pressure range (23 Pa to 982 Pa), S2 in the pressure range from 982 to 10 kPa, and S3 in the pressure range from 10 to 30 kPa. The corresponding sensitivities of S1, S2 and S3 are 0.55 kPa−1, 3.81 kPa−1, and 2.52 kPa−1, respectively. In addition, the effects of different paper types on the sensing performance were explored. A filter paper substrate was employed for assembling the pressure sensor. The photographs of the filter paper after being impregnated with MXene nanosheets (MXene/filter paper) and the SEM images are shown in Figure S10a-c. The comparison of the sensing performance of the MXene/filter paper-based pressure sensor and the MXene/tissue paper-based

ACS Paragon Plus Environment 10

Page 11 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

pressure sensor (Figure S10d) showed that the MXene/tissue paper-based pressure sensor performed significantly better than the MXene/filter paper-based pressure sensor, which is due to the relatively rough surface of the tissue paper. The two-dimensional (2D) view and three-dimensional (3D) topology of the two papers are shown in Figure S11 from a Sensofar 3D optical profiler. As shown in the 3D view in Figure S11, the surface undulation range of the tissue paper (-55.4-55.4 µm) is significantly larger than the range of the filter paper (-27.8-27.8 µm), indicating better surface roughness of the tissue paper47. Furthermore, the different sensing sensitivities of the MXene/tissue paper-based pressure sensor with different thicknesses of the PLA encapsulation layer are demonstrated in Figure S12, indicating that the sensor with a thinner PLA encapsulation layer possesses better sensing sensitivities, which agrees well with the reported literature48. Therefore, the MXene/tissue paper-based pressure sensor with a 40 µm PLA encapsulation layer could be the optimal candidate for further sensitive broad-range human-machine interfacing. Figure 2d shows the reproducible sensing performance of the MXene/tissue paper-based pressure sensor. After 10000 compressive loading/unloading tests between 0-3036 Pa, the sensing response was clearly retained, indicating the potential for robust and stable human motion biomonitoring. Moreover, the current sensing responses matched well with the input pressure waves under a pressure of 3036 Pa (Figure S13), indicating that the

ACS Paragon Plus Environment 11

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 28

output sensing signals can be accurately tracked and reflected the input loading forces. In addition, Figure 2e and Figure S14 show the response time (11 ms) and the recovery time (25 ms) of the MXene/tissue paper-based pressure sensor under a pressure of 3036 Pa, ensuring a real-time sensing response to instant human-machine interfacing. As shown in Figure S15, no obvious effect of the different compressing strain rates on the sensing performance of the MXene/tissue paper-based pressure sensor was observed at 3036 Pa. As shown in Figure 2f, the I-V curves indicated that the pressure-sensitive sensing response of the sensor was stable at different external pressures and that the resistance (slope of I–V curves) was constant under each pressure.

ACS Paragon Plus Environment 12

Page 13 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Figure 3. (a) Sensing performance of the pressure sensor attached to the arm muscle for reliable detection of radial muscle contraction resulting from reversibly making a fist. Inset: Photograph of the sensor attached onto the arm muscle while reversibly making a fist. (b) Sensing performance of the pressure sensor mounted onto the cheek for real-time sensing of occlusion. Inset: Photograph of the sensor attached onto the cheek. (c) Sensing performance of the pressure sensor adhered onto a human throat for timely sensing of swallowing. Inset: Photograph of the sensor attached onto a human throat. (d) Sensing performance of the pressure sensor coated on the wrist for sensing the wrist pulse. Inset: Photograph of the sensor attached onto the wrist and palm. (e) The enlarged waveform of the blood pulse. (f) Current response of the sensor upon loading a sugar granule (2.3 mg). Inset: Photograph of a sugar granule (2.3 mg) loaded onto the sensor. (g) Sensing performance of the sensor under imitated knocking of early-stage Parkinson’s disease featuring a static tremor frequency of 5 Hz. Inset: Photograph of the imitated knocking of the sensor. (h) The enlarged sensing performance of the imitated knocking. (j) Sensing performance of Morse code for “MXene” produced by touching the sensors. Due to the high sensitivity over a broad sensing range and flexibility of the MXene/tissue paper-based pressure sensor, it is a reliable candidate for real-time detection of full-range human motions. The samples were attached to the skin with the help of medical tape for all human body interactions. The

ACS Paragon Plus Environment 13

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 28

MXene/tissue paper-based pressure sensor was attached to an arm muscle and was employed to reliably detect the radial muscle contraction through reversibly making a fist (Figure 3a), which is extremely useful for physical training and even potentially for curing muscle damage. After making a fist, the current signal increased along with the compression of the sensor. Figure 3b shows that a sensor was attached to a cheek for real-time sensing of occlusion, one of the physiological motions of humans. Upon occlusion, the sensing current signal timely increased, demonstrating that increased conductivity could be obtained from the improved contact and increased number of conductive paths between the MXene and the interdigitated electrodes under external pressure. In addition, our pressure sensor could also be employed to detect cycles of bending, torsion, and touching, demonstrating excellent and stable sensing performance (Figure S16a-c). Figure S17 shows the sensing performances of the device at different radii of curvature. Furthermore, our pressure sensor was also attached onto a neck for real-time detection of swallowing and speaking, demonstrating varied current signals under the external pressure arising from swallowing (Figure 3c). The MXene/tissue paper-based pressure sensor could be used for timely monitoring of the physical force of the wrist pulse for potential disease diagnosis (Figure 3d-e). Figure 3d displays the reproducible and regular waveforms of a wrist pulse with a periodic beating of 80 beats/min when the

ACS Paragon Plus Environment 14

Page 15 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

pressure sensor was fixed onto the wrist compared to the background sensing response level of the pressure sensor attached to the palm. Figure 3e shows the enlarged wrist pulse waveforms with the characteristic systolic peak (P1) and diastolic peak (P2). The radial augmentation index (P2/P1), an important value for characterizing arterial stiffness, is calculated to be 0.74. This value is in good accordance with the literature reference for a 25-year-old healthy female in a normal state (height at 160 cm)

49.

The pressure sensor could

operate well at an operation voltage of 0.01 V with a current on the order of 10−6 A, corresponding to an energy consumption of approximately 10-8 W. As shown in Figure 3f, a sugar granule (2.3 mg) with a bottom area of 1.5 mm × 1.5 mm was loaded onto the surface of the pressure sensor to obtain the experimental detection limit, which was found to be 10.2 Pa. In addition, the pressure sensors were capable of monitoring low-frequency changes for potential disease diagnosis. For example, early-stage Parkinson’s disease (PD), a slow and gradual neurodegenerative disease, features static tremors at a frequency of 4~6 Hz. Thus, it is vitally important to detect static tremor signs for potentially early stage disease diagnosis. Knocking on the pressure sensor at a relevant characteristic frequency could simulate early-stage Parkinson’s disease with static tremors (Figure 3g). The enlarged view of the imitated knocking on the pressure sensor with the static tremor frequency at 5 Hz is demonstrated in Figure 3h, implying its potential application for healthcare prediction of early-stage Parkinson’s disease50. As shown in Figure

ACS Paragon Plus Environment 15

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 28

3i, Morse code was input by touching the pressure sensor surface, demonstrating the output of the sensing curves of the current responses with five corresponding characters, such as “MXene”.

Figure 4. (a) Photograph of the E-skin assembled from the MXene/tissue paper-based sensors with 4 × 4 pixels and (b) schematic illustration of the

ACS Paragon Plus Environment 16

Page 17 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

E-skin assembled from the MXene/tissue paper-based sensors with 4 × 4 pixels. (c) Photograph of two fingers touching the E-skin and (d) the corresponding pressure distribution mapping from the sensing responses. (e) Photograph of three fingers touching the E-skin and (d) the corresponding pressure distribution mapping from the sensing responses. (g) Photographs of the MXene/tissue paper-based sensors attached to a robot femorotibial joint with the arm undergoing uplift cycles along with the hand touching the sensor for (h) remote touching monitoring by wireless connection of the sensing response to a mobile phone. (i) The corresponding real-time sensing responses received wirelessly by the mobile phone for monitoring the reversible arm uplift cycles along with the reversible touching of the sensor surfaces and (j) the related resistance changes. Wearable pressure sensors could be assembled as smart artificial E-skins for detecting various tactile signals and mapping spatial pressure distribution (Figure 4a-f). Figure 4a and 4b show a photograph of the E-skin assembled from the MXene/tissue paper-based sensor arrays (each is 6×8 mm2) with 4×4 pixels on a PLA substrate and a schematic illustration of the E-skin, respectively. When fingers touched the sensor surface, the contact points touched by the fingers were recognized by collecting the sensing response of each pixel and plotting the sensing response map with the pressure distribution and location. Figure 4c-f shows that the E-skin could differentiate the position and number of fingers that were pressing the sensing area very

ACS Paragon Plus Environment 17

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 28

well. When two fingers touched the specific sensing E-skin surface, the E-skin gave sensing responses, as shown in Figure 4c-d. When three fingers pressed the E-skin, the pressure distribution and location were identified from the sensing response contrast mapping (Figure 4e-f). These results indicate that the E-skins assembled from the MXene/tissue paper-based sensor arrays could be used for simultaneous spatial mapping of touchable pressure distributions and locations. Moreover, the flexible MXene/tissue paper-based pressure sensor could be attached to the femorotibial joint of a robot with the integration of a wireless transmitter for wireless sensitive detection of a reversible arm uplift cycle along with reversible touching of its hand to the pressure sensor (Figure 4g). The sensing response could be wirelessly sent to a mobile phone for remote touch monitoring (Figure 4h). Figure 4i and 4j show the real-time wireless sensing performance of the MXene/tissue paper-based pressure sensor for monitoring the reversible arm uplift cycle for reversible touching of the hand of the robot to the sensor, displaying a repeated and real-time resistance decrease resulting from the larger robot motions. Table S1 shows the comparison of the sensing performances of our devices with other devices. This indicates that the wearable MXene/tissue paper-based pressure sensor can wirelessly monitor human healthcare and human-machine interfacing with excellent reproducibility, timely wireless communication, and stability.

ACS Paragon Plus Environment 18

Page 19 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Figure 5. (a) Photographs of the MXene/tissue paper sensor placed in a 0.5 M NaOH solution for different times. Photographs and SEM images of the MXene/tissue paper sensor (b-c) before and (d-e) after degradation. To study the degradable performance of the sensors, the sensor device was placed into PBS solution and NaOH solution dyed with rhodamine at 37 °C, and the resulting mass changes were measured. Figure 5a shows photographs of the MXene/tissue paper sensor placed in 0.5 M NaOH solution for different times. The photographs indicate that after 14 days, the sensor was degraded due to the degradation of the PLA and the tissue paper. Photographs and SEM images of the MXene/tissue paper sensor before and after 14 days are shown in Figure 5, demonstrating that after 14 days, the sensor was degraded due to the high degradability of the PLA and the tissue paper. The color and microstructure of the MXene/tissue paper changed after 14 days (Figure 5a-e), indicating that the MXene/tissue paper was degraded. The mass loss observed for the sensors incubated in PBS solution and NaOH

ACS Paragon Plus Environment 19

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 28

solution was 23% and 68%, respectively (Figure S18). These results fully demonstrate that our sensor was degradable and could not cause any severe harm to the environment. The flexible wearable transient pressure sensor with the MXene nanosheets was employed for highly sensitive broad-range human-machine interfacing and human motion biomonitoring. The biocompatibility of the flexible pressure sensor was evaluated by performing a toxicity test for direct contact of the sensor with the human body. Silver paste possesses antibacterial properties and an ideal application is in smart wound dressings. Meanwhile, the low content of silver paste assures the reliable high proliferation of cells and good biocompatibility.51,52 To assess the toxicity of the sensor, we performed an in vitro cytotoxicity test using L929 cells cultured for 24, 48, and 72 h. As shown in Figures S19a-d, L929 cells were cultured in the extract substrates of the tissue culture plate (TCP), PLA electrode, MXene/tissue paper and the sensor for 72 h and showed a spindle-shaped morphology, indicating that the cells were in a healthy growth state. When the L929 cells were cultured for 24, 48 and 72 h, the relative growth rate (RGR) values were not significantly different from the tissue culture plates, indicating that the sensor is not cytotoxic to L929 cells (Figure S19e). These results indicate that the sensor could be used as a human-friendly wearable device for human-machine interfacing.

ACS Paragon Plus Environment 20

Page 21 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

In summary, a flexible wearable transient pressure sensor with an MXene mesh was fabricated for highly sensitive, reproducible, wireless, degradable and broad-range (up to 30 kPa) human-machine interfacing. The flexible pressure sensor was assembled by impregnating MXene nanosheets into tissue papers and sandwiching them between a biodegradable PLA sheet and a PLA sheet patterned with an interdigitated conductive electrode. The assembled flexible transient pressure sensors exhibited a high sensitivity, low detection limit (10.2 Pa), fast response (11 ms), low power consumption (10-8 W), excellent reproducibility over 10000 cycles, reliable biocompatibility, and environmentally friendly degradation. The pressure sensor could be attached to human skin to obtain a variety of broad-range biomonitoring data that ranged from small deformations to large movements. Moreover, the pressure sensor could be used to input Morse code by touching the sensor device surface. E-skins were successfully assembled from the sensor arrays to detect various tactile signals and to map spatial pressure distributions. Furthermore, the pressure sensor could be connected with a wireless transmitter for wireless sensing of a human-machine interface. The MXene-coated tissue meshes with the features of high conductivity, large specific surface area, reliable conductive paths and tunable contact area under external pressure could be attributed to the excellent sensing performance of the pressure sensor. This approach provides new ways to assemble flexible wearable transient pressure sensors with high sensitivity,

ACS Paragon Plus Environment 21

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 28

reproducibility, wireless capability, and degradability for degradable electronic devices, next-generation artificial skins, human-machine interfacing devices, and personal healthcare biomonitoring devices. ASSOCIATED CONTENT Supporting Information Details on materials, synthesis, and materials characterization (X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Atomic Force Microscope (AFM), scanning electron microscopy (SEM) images, and the piezoresistive properties of the samples). This information is available free of charge via the Internet at http://pubs.acs.org. AUTHOR INFORMATION Corresponding Authors †E-mail:

[email protected] (P. Wan)

‡E-mail:

[email protected] (G. Yu)

Notes The authors declare no competing financial interest. ACKNOWLEDGMENTS P. W. acknowledges financial support from National Natural Science Foundation of China, Beijing Natural Science Foundation (2152023), National Key Research and Development Project (2016YFC0801302), Beijing Talent Fund (2016000021223ZK34), and the Fundamental Research Funds for the

ACS Paragon Plus Environment 22

Page 23 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Central Universities. G. Y. acknowledges financial support from the Sloan Research Fellowship and the Welch Foundation award F-1861. REFERENCES (1) Schwartz, G.; Tee, B. C.; Mei, J.; Appleton, A. L.; Kim, D. H.; Wang, H.; Bao, Z. Nat. Commun. 2013, 4, 1859. (2) Lou, Z.; Chen, S.; Wang, L.; Jiang, K.; Shen, G. Nano Energy 2016, 23, 7-14. (3) Cai, Y.; Shen, J.; Dai, Z.; Zang, X.; Dong, Q.; Guan, G.; Li, L. J.; Huang, W.; Dong, X. Adv. Mater. 2017, 29, 1606411. (4) Li, L.; Pan, L.; Ma, Z.; Yan, K.; Cheng, W.; Shi, Y.; Yu, G. Nano Lett. 2018, 18, 3322. (5) Kim, J.; Lee, M.; Shim, H. J.; Ghaffari, R.; Cho, H. R.; Son, D.; Jung, Y. H.; Soh, M.; Choi, C.; Jung, S.; Chu, K.; Jeon, D.; Lee, S. T.; Kim, J. H.; Choi, S. H.; Hyeon, T.; Kim, D. H. Nat. Commun. 2014, 5, 5747. (6) Bae, G. Y.; Pak, S. W.; Kim, D.; Lee, G.; Kim do, H.; Chung, Y.; Cho, K. Adv. Mater. 2016, 28, 5300-5306. (7) Choong, C. L.; Shim, M. B.; Lee, B. S.; Jeon, S.; Ko, D. S.; Kang, T. H.; Bae, J.; Lee, S. H.; Byun, K. E.; Im, J.; Jeong, Y. J.; Park, C. E.; Park, J. J.; Chung, U. I. Adv. Mater. 2014, 26, 3451-3458. (8) Lai, Y.-C.; Ye, B.-W.; Lu, C.-F.; Chen, C.-T.; Jao, M.-H.; Su, W.-F.; Hung, W.-Y.; Lin, T.-Y.; Chen, Y.-F. Adv. Funct. Mater. 2016, 26, 1286-1295. (9) Liu, H.; Dong, M.; Huang, W.; Gao, J.; Dai, K.; Guo, J.; Zheng, G.; Liu, C.; Shen, C.; Guo, Z. J. Mater. Chem. C 2017, 5, 73-83.

(10) Si, Y.; Wang, L.; Wang, X.; Tang, N.; Yu, J.; Ding, B. Adv. Mater. 2017, 29, 1700339. (11) Lee, J.; Kwon, H.; Seo, J.; Shin, S.; Koo, J. H.; Pang, C.; Son, S.; Kim, J. H.; Jang, Y. H.; Kim, D.

ACS Paragon Plus Environment 23

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 24 of 28

E.; Lee, T. Adv. Mater. 2015, 27, 2433-2439. (12) Lei, Z.; Wang, Q.; Sun, S.; Zhu, W.; Wu, P. Adv. Mater. 2017, 29, 1700321. (13) Viry, L.; Levi, A.; Totaro, M.; Mondini, A.; Mattoli, V.; Mazzolai, B.; Beccai, L. Adv. Mater. 2014, 26, 2659-2664. (14) Pan, L.; Chortos, A.; Yu, G.; Wang, Y.; Isaacson, S.; Allen, R.; Shi, Y.; Dauskardt, R.; Bao, Z. Nat. Commun. 2014, 5, 3002. (15) Shin, K.-Y.; Lee, J. S.; Jang, J. Nano Energy 2016, 22, 95-104. (16) Wang, L.; Chen, D.; Jiang, K.; Shen, G. Chem. Soc. Rev. 2017, 46, 6764-6815. (17) Khan, U.; Kim, T. H.; Ryu, H.; Seung, W.; Kim, S. W. Adv. Mater. 2017, 29, 1603544. (18) Wang, X.; Zhang, H.; Dong, L.; Han, X.; Du, W.; Zhai, J.; Pan, C.; Wang, Z. L. Adv. Mater. 2016, 28, 2896-2903. (19) Lee, D.; Lee, H.; Jeong, Y.; Ahn, Y.; Nam, G.; Lee, Y. Adv. Mater. 2016, 28, 9364.-9369. (20) Zhan, Z.; Lin, R.; Tran, V. T.; An, J.; Wei, Y.; Du, H.; Tran, T.; Lu, W. ACS Appl. Mater. Interfaces 2017, 9, 37921-37928. (21) Liu, Z.; Qi, D.; Guo, P.; Liu, Y.; Zhu, B.; Yang, H.; Liu, Y.; Li, B.; Zhang, C.; Yu, J. Adv. Mater. 2015, 27, 6230-6237. (22) Park, H.; Jeong, Y. R.; Yun, J.; Hong, S. Y.; Jin, S.; Lee, S. J.; Zi, G.; Ha, J. S. ACS Nano 2015, 9, 9974-9985. (23) Yao, H. B.; Ge, J.; Wang, C. F.; Wang, X.; Hu, W.; Zheng, Z. J.; Ni, Y.; Yu, S. H. Adv. Mater. 2013, 25, 6692-6698. (24) Cai, Y.; Shen, J.; Ge, G.; Zhang, Y.; Jin, W.; Huang, W.; Shao, J.; Yang, J.; Dong, X. ACS Nano 2018, 12, 56-62.

ACS Paragon Plus Environment 24

Page 25 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

(25) Jian, M.; Xia, K.; Wang, Q.; Yin, Z.; Wang, H.; Wang, C.; Xie, H.; Zhang, M.; Zhang, Y. Adv. Funct. Mater. 2017, 27, 1606066. (26) Zhao, H.; Bai, J. ACS Appl. Mater. Interfaces 2015, 7, 9652-9659. (27) Simon, P. ACS Nano 2017, 11, 2393. (28) Zhang, C. J.; Anasori, B.; Seral-Ascaso, A.; Park, S. H.; McEvoy, N.; Shmeliov, A.; Duesberg, G. S.; Coleman, J. N.; Gogotsi, Y.; Nicolosi, V. Adv. Mater. 2017, 29, 1702678. (29) Hu, M.; Li, Z.; Hu, T.; Zhu, S.; Zhang, C.; Wang, X. ACS Nano 2016, 10, 11344-11350. (30) Liu, Y. T.; Zhang, P.; Sun, N.; Anasori, B.; Zhu, Q. Z.; Liu, H.; Gogotsi, Y.; Xu, B. Adv. Mater. 2018, 30, 1707334. (31) Ma, Y.; Liu, N.; Li, L.; Hu, X.; Zou, Z.; Wang, J.; Luo, S.; Gao, Y. Nat. Commun. 2017, 8, 1207. (32) Yue, Y.; Liu, N.; Liu, W.; Li, M.; Ma, Y.; Luo, C.; Wang, S.; Rao, J.; Hu, X.; Su, J.; Zhang, Z.; Huang, Q.; Gao, Y. Nano Energy 2018, 50, 79. (33) Rao, L. N. Int. J. Chem. Res. 2014, 6, 1343-1353. (34) Bettinger, C. J.; Bao, Z. Adv. Mater. 2010, 22, 651-655.

(35) Irimia-Vladu, M.; Głowacki, E. D.; Voss, G.; Bauer, S.; Sariciftci, N. S. Mater. Today 2012, 15, 340-346. (36) Irimia-Vladu, M.; Troshin, P. A.; Reisinger, M.; Shmygleva, L.; Kanbur, Y.; Schwabegger, G.; Bodea, M.; Schwödiauer, R.; Mumyatov, A.; Fergus, J. W.; Razumov, V. F.; Sitter, H.; Sariciftci, N. S.; Bauer, S. Adv. Funct. Mater. 2010, 20, 4069-4076. (37) Jia, X.; Wang, C.; Zhao, C.; Ge, Y.; Wallace, G. G. Adv. Funct. Mater. 2016, 26, 1454-1462. (38) Zhou, Y.; Fuentes-Hernandez, C.; Khan, T. M.; Liu, J. C.; Hsu, J.; Shim, J. W.; Dindar, A.; Youngblood, J. P.; Moon, R. J.; Kippelen, B. Sci. Rep. 2013, 3, 1536.

ACS Paragon Plus Environment 25

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 26 of 28

(39) Lee, G.; Kang, S.-K.; Won, S. M.; Gutruf, P.; Jeong, Y. R.; Koo, J.; Lee, S.-S.; Rogers, J. A.; Ha, J. S. Adv. Energy Mater. 2017, 7, 1700157. (40) Gumus, A.; Alam, A.; Hussain, A. M.; Mishra, K.; Wicaksono, I.; Torres Sevilla, G. A.; Shaikh, S. F.; Diaz, M.; Velling, S.; Ghoneim, M. T.; Ahmed, S. M.; Hussain, M. M. Adv. Mater. Technol. 2017, 2, 1600264.

(41) Tao, H.; Hwang, S. W.; Marelli, B.; An, B.; Moreau, J. E.; Yang, M.; Brenckle, M. A.; Kim, S.; Kaplan, D. L.; Rogers, J. A.; Omenetto, F. G. Proc. Natl. Acad. Sci. USA 2014, 111, 17385-17389. (42) Kang, S. K.; Murphy, R. K.; Hwang, S. W.; Lee, S. M.; Harburg, D. V.; Krueger, N. A.; Shin, J.; Gamble, P.; Cheng, H.; Yu, S.; Liu, Z.; McCall, J. G.; Stephen, M.; Ying, H.; Kim, J.; Park, G.; Webb, R. C.; Lee, C. H.; Chung, S.; Wie, D. S.; Gujar, A. D.; Vemulapalli, B.; Kim, A. H.; Lee, K. M.; Cheng, J.; Huang, Y.; Lee, S. H.; Braun, P. V.; Ray, W. Z.; Rogers, J. A. Nature 2016, 530, 71-76. (43) Tsang, M.; Armutlulu, A.; Martinez, A. W.; Allen, S. A. B.; Allen, M. G. Microsyst.& Nanoeng. 2015, 1,15024. (44) Salvatore, G. A.; Sülzle, J.; Dalla Valle, F.; Cantarella, G.; Robotti, F.; Jokic, P.; Knobelspies, S.; Daus, A.; Büthe, L.; Petti, L.; Kirchgessner, N.; Hopf, R.; Magno, M.; Tröster, G. Adv. Funct. Mater. 2017, 27, 1702390.

(45) Liu, J.; Zhang, H. B.; Sun, R.; Liu, Y.; Liu, Z.; Zhou, A.; Yu, Z. Z. Adv. Mater. 2017, 29, 1702367. (46) Yan, J.; Ren, C. E.; Maleski, K.; Hatter, C. B.; Anasori, B.; Urbankowski, P.; Sarycheva, A.; Gogotsi, Y. Adv. Funct. Mater. 2017, 27, 1701264. (47) Tao, L. Q; Zhang, K. N; Tian, H; Liu, Y; Wang, D. Y; Chen, Y. Q; Yang, Y; Ren, T. L. ACS Nano

ACS Paragon Plus Environment 26

Page 27 of 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

2017, 11, 8790-8795.

(48) Gong, S.; Schwalb, W.; Wang, Y.; Chen, Y.; Tang, Y.; Si, J.; Shirinzadeh, B.; Cheng, W. Nat. Commun. 2014, 5, 3132. (49) Nichols, W. W. Am. J. Hypertens. 2005, 18, 3S-10S. (50) Giancardo, L.; Sanchez-Ferro, A.; Arroyo-Gallego, T.; Butterworth, I.; Mendoza, C. S.; Montero, P.; Matarazzo, M.; Obeso, J. A.; Gray, M. L.; Estepar, R. S. Sci. Rep. 2016, 6, 34468. (51) Najafabadi, A. H.; Tamayol, A.; Annabi, N.; Ochoa, M.; Mostafalu, P.; Akbari, M.; Nikkhah, M.; Rahimi, R.; Dokmeci, M. R.; Sonkusale, S.; Ziaie, B.; Khademhosseini, A. Adv. Mater. 2014, 26, 5823-5830. (52) Filip, D.; Macocinschi, D.; Paslaru, E.; Munteanu, B. S.; Dumitriu, R. P.; Lungu, M.; Vasile, C. J. Nanopart. Res. 2014, 16, 2710.

ACS Paragon Plus Environment 27

Nano Letters 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 28 of 28

Table of Contents graphic

28

ACS Paragon Plus Environment