ARTHUR H. THOMAS COMPANY

tronic amplification system andbuilt-in transformer for. a.c. operation; meter for ... Teletype Services: Western Union WUX and Bell System PH-72. For...
0 downloads 0 Views 155KB Size
BAUSCH

&

LOMB

" S P E C T R O N IC 2 0 "

SPECTROPHOTOMETER COLORIMETER DIFFRACTION GRATING TYPE

^

Range 375 mmu in the violet to 950 mmu in infrared.

^

Band width 20 mmu.

^

Direct reading in transmission or optical density.

4 Plug-in printed electronic circuit.

9084-K

SPECTROPHOTOMETER



COLORIMETER,

Bausch & Lomb "Spectronic 2 0 . " A wide range, compact, versatile, direct reading instrument, with high degree of accuracy, simple to operate, and at remarkably low price. Effective band width 20 m m u , suitable for either spec­ trophotometry or colorimetry. Provides monochromatic light in the range from 375 m m u in the violet to 950 m m u in infrared. Wavelength dial graduated at intervals of 5 mmu. Consisting of diffraction grating monochromator with prefocused light source and fixed slits ; phototubes ; elec­ tronic amplification system a n d built-in transformer for a.c. operation; meter for direct indication of transmis­ sion a n d optical density; and readily interchangeable holders for test tubes or cells. T h r e e controls adjust the wavelength setting, light intensity and zero, respectively. Results are reproducible within 0 . 5 % .

9084-K. Spectrophotometer-Colorimeter, B.&L. "Spectronic 2 0 , " with blue-sensitive and red-sensitive phototubes and filter; for routine colorimetric determinations at a single wavelength; with single place sample holder and three J^-inch test tubes. For 115 volts, 60 eye., a.c 230.00

9085-M. Special External Voltage Stabilizing Transformer; recommended for use with above to insure stable operation. For use on any input between 100 and 130 volts, 60 eye., a.c.. . 30.00 9084-E. Spectrophotometer-Colorimeter, B.&L. "Spectronic 2 0 , " complete outfit for rapid spectral scanning and plotting of absorption curves; consisting of 9084-K with blue and red-sensitive phototubes and filter, 9085-M Voltage Stabilizing Transformer and 9085-G Thomas Roto-Cell with double 1 ml cell with 10 mm light paths. For 115 volts, 60 e y e , a.c 336.20

THOMAS ROTO-CELL A liquid-cooled double cell 0( carrier, for rapid spectro­ photometry: scanning at con­ trolled temperatures. Readily interchangeable with the single place sample holder of "Spec­ tronic 2 0 " ; permits instantaneous interchange within the instrument of a 1 ml sample and blank or standard into the light path, thereby greatly facilitating preparation of spectral transmission or absorption curves. Consisting of a swivel-action, water jacketed holder, with lightproofing collar, slotted carrier for two 1 ml cells, and control knob with stops for positioning either cell, and for completely blocking the light beam for checking dark cur­ rent adjustment.

9085-C.

9085-C. Roto-CeU, T h o m a s , as above described, complete with double cell of Corex glass with two parallel chambers each with 10 m m light path and cover 76.20

Copy of Bulletin 121 sent upon request. I

SYMBOL OF QUALITY

I

A.H.T.CO. ΗππχννππΗ LABORATORY APPARATUS |

ARTHUR H. THOMAS

COMPANY

Laboratory Apparatus and Reagents WEST W A S H I N G T O N

SQUARE

PHILADELPHIA

5,

PA.

Teletype Services: Western Union W U X a n d Bell System PH-72