26 A
ANALYTICAL
ALOE CENTRIFUGES—Designed for
the smaller
chemical
CHEMISTRY
especially laboratory
These efficient centrifuges are ideally suited to the need of the chemical labora tory. Balanced design . . . sturdy construction . . . exact speed control assure dependable, silent operation. Equipped with universal motors for operation on AC or D C current and improved metal shields to accommodate standard 15 ml conical centrifuge tubes or 15 χ 125 mm culture tubes. Heavily rubber cushioned feet absorb vibration and prevent creeping, even on glass surfaces. Heads are of cast brass, chrome plated to resist chemical action. Housings are also acid resistant. 23760
JL23760 Aloe 2-Plaee Electric Centrifuge, for operation up to 1800 r.p.m. Supplied with two metal shields, one each plain and graduated 15 ml glass centrifuge tubes, cord and plug, complete as described $28.50 JL23780 Aloe Dome Type 2-Place Electric Centrifuge, for operation up to 3400 r.p.m. on AC current and 4000 r.p.m. on D C current. Supplied with two metal shields, one each plain and graduated 15 ml glass centrifuge tubes, cord and plug, complete as described $52.00 JL23790 Same, with 4-place head and two each plain and graduated 15 ml glass centrifuge tubes, complete as described $54.00
S.
ALOE
LABORATORY
C O M P A N Y
APPARATUS AND
1 8 3 1 Olive Street
·
" ^ t ^
RSAGINTS
Saint Louis 3 , Missouri
23790
GAS G R A V I T Y BALANCE
PULSAMETER A Pulsation Measuring I n s t r u m e n t
Gives d e p e n d a b l e and accurate results on wet gas, dry natural gas and artificial gas. In determining the specific g r a v i t y of gas, will give results that can be checked within 3 points in the fourth place. Each unit is completely e q u i p p e d with needle valves and carrying case.
Designed for l a b o r a t o r y , p l a n t a n d field
The "Pulsameter" is a n instrument for measuring the differential pulsation amplitude across a n orifice meter. W h e r e orifice meters a r e located n e a r Com pressor stations, pulsations a r e usually present. The magnitude of these pulsations depends on local con d i t i o n s — number a n d kind of compressors, piping l a y out, etc. The "Pulsameter" -can b e connected to the orifice meter g a u g e piping a n d for the condition of measurement the maximum differential pulsation a m plitude a n d recorded differential reading on the orifice meter a r e determined. From this information the accuracy of the orifice meter under the pulsating condition is indicated. This testing equipment is used in connection with gas measurement by orifice meter.
— COMPLETE LINE OF SCIENTIFIC LABORATORY EQUIPMENT— Write
for Catalog No.
30-A.
THE REFINERY SUPPLY CO, 621 E. 4th Street
Main Office and Plant TULSA 3, O K L A H O M A Houston Office Temporarily Discontinued
Ph.4-8144