Why you must have Capillary Columns Gasoline
Ortho-meta-para xylenes sr\
Θ S a m p l e : Gasoline 30-114°C. Sample size: 0.002 ml. Detector: Hydrogen-Flame V o l t a g e : 300 Sensitivity: 10"'° A t t e n . s e t : 2. Rec. Range 5MV S u b s t r a t e : Hexadecene. C a r r i e r : Helium C o l . : 200-ft. SS w i t h I.D. of 0.01" T e m p . ° C : F.H. 290; S T 150; C o l . 90.; D.T. 150; Detr. 30. Flow m l / m i n : Β 400; C o l . 1.5.
Detector: T r i t i u m V o l t a g e : 1000V C o l u m n : 150-ft l o n g ; 0.01 I.D. T e m p . ° C : C o l . 160; F.H. 250; Det. 200 Liquid P h a s e : Polybutene Peaks — a. solvent b. Delta 8, 11 Methyl linoleate c. Delta 10, 13 Methyl linoleate d. Delta 11, 14 Methyl linoleate
Θ Sample Size: 0.1 ul D e t e c t o r : Radium 226 Range 10. V o l t a g e 1250 Liq. P h a s e : Carbowax 1500. Carrier: A r . 40 psi C o l : 200-ft. Capillary; O D .0625"; ID .010" T e m p . ° C : C o l . 65; F.H. 255; Detr. 135 Flow m l / m i n : Scav. 80; S p l i t 3 0 0 1. Benzene 2. T o l u e n e 3. P-xylene 4. M-xylene 5. O-xylene
38 A
·
ANALYTICAL CHEMISTRY
Detector: Tritium V o l t a g e : 1000V C o l u m n : 150-ft. l o n g ; . 0 1 " I.D. T e m p . " C : C o l . 170; F.H. 250; Det. 200 Liquid P h a s e : Ethylene Glycol Glutarate Peaks — Cis and Trans Methyl Oleate
|
for the BEST
in
Gas Chromatography Quite S i m p l y . . . Your gas chromatograph is not capable of giving you the very best in gas chromatographic analysis unless it is equipped with capillary columns. W h y . . . Consider these advantages of capillary c o l u m n s : •
Resolutions which are impossible on packed columns.
•
Analyze very small samples with ionization detector systems.
•
Temperature programming extends the range of capillary columns, simultaneously providing excellent resolution and high sensitivity to report trace constituents in extremely complex mixtures.
•
Better resolution of complex samples with very similar structural groups.
•
A complete analysis in 20 minutes which may take more than an hour with packed columns.
•
Analyses which require temperature programming with packed columns can normally be performed isothermally with capillary columns.
Also of Prime Importance . . . Barber-Coiman has been a leader in t h e manufacture of capillary columns and capillary column gas chromatographs for many years. The excellent capillary runs on the preceding page are examples of the performance obtained with Barber-Coiman capillaries. Remember — " T h e Chromatogram Is The Proof." Y o u Should Also K n o w that . . . The Barber-Coiman Series 5000 Selecta-System Gas Chromatographs were designed for capillary column systems and they feature:
The Barber-Coiman Series 5000 Selecta-System represents a most flexible system for keeping abreast of a fast-changing technology. The modular unitized system fits your needs now and later — over 20 different components help to make up more than 50 different system combinations.
•
Model 5061 Column Bath with Linear Sample Inlet Splitter.
•
Model 5121 High Temperature Flame Detector. Detectability —10~14 Mole/sec.
•
Model 5041 Battery Electrometer — Noise level 10-' 1 A m p s .
For further information on capillary column chromatographs and other superior performance gas chromatographs available in the SelectaSystem, contact one of the 42 local Barber-Coiman Branch Offices — see the Yellow Pages. • Licensed under Golay Patent 2920478.
BARBER COLMAN
BARBER-COLMAN
COMPANY
Dept.C, 15104 Rock Street, Rockford, Illinois, U.S.A. BARBER-COLMAN of C A N A D A , Ltd., Dept.C, Toronto 4 Montreal · Export Agent: Ad. Auriema, Inc., N.Y. Cirlce No. 106 on Readers' Service Card VOL.
36, NO. 3, MARCH 1964
•
39 A