N E W CHEMICALS
Radioactive gas mixtures c e r t i f i e d t o a high degree of accuracy are now available t h r o u g h t h e c o m b i n e d e f f o r t s of M a t h e son Gas P r o d u c t s a n d Gollob A n a l y t i c a l Service. N e w p r i m a r y s t a n d a r d s will i n c l u d e Gollob's radioanalysis a c c u r a t e t o ± 5 % of c o m p o n e n t v a l u e a n d a l s o a m a s s s p e c t r o m e t e r a n a l y s i s for i m p u r i t i e s as well as for c o m p o n e n t s of t h e b a c k g r o u n d gas m i x t u r e . Certified s t a n d a r d s at lower cost are available w i t h radioanalysis accurate to ± 1 0 % . A l m o s t a n y gas or c o m b i n a t i o n of gases can be b l e n d e d with a radioactive c o m p o n e n t , p r o v i d e d t h e i n g r e d i e n t s d o not react c h e m i c a l l y or explosively w i t h each other. M i x t u r e s c o n t a i n i n g n u c l i d e s of krypton-85, tri t i u m , sulfur-35, a n d carbon-14 are of f e r e d . M a t h e s o n Gas P r o d u c t s . 201933-2400 441 Ion-exchange r e s i n s of f i n e m e s h in narrow particle ranges (37-44 /xm) for high-resolution l i q u i d chromatography i n c l u d e Bio-Rex 5, p o l y a l k y l a m i n e , inter m e d i a t e base resin; 9, p y r i d i n i u m , s t r o n g base resin; 70, carboxylic a c i d , w e a k acid resin; 63, p h o s p h o r i c a c i d , i n t e r m e d i a t e acid r e s i n ; a n d 40, s u l f o n a t e d p h e n o l i c , s t r o n g acid resin. $25/25 g r a m s . BioRad Laboratories. 415-234-4130 442 Surface-area standards i n c l u d e 11 dif f e r e n t p o w d e r s w i t h surface areas rang i n g f r o m 0.66 t o 1000 s q u a r e m e t e r s per g r a m . Mean d i a m e t e r s are also given for each s t a n d a r d . D u k e S t a n d a r d s Co. 415-328-2400 443 R e a g e n t - g r a d e acetic a c i d s u i t a b l e for c h o l e s t e r o l d e t e r m i n a t i o n s has special controls t o l i m i t a l d e h y d e s ; a m a x i m u m l i m i t of 0.05% a c e t a l d e h y d e e n s u r e s a low level of t h i s i m p u r i t y . J . T. Baker C h e m i cal Co. 201-859-2151 444 Ultrex high-purity materials for l i q u i d crystal research i n c l u d e cholesteryl chlo ride a n d cholesteryl acetate for prepara t i o n of l i q u i d crystals a n d four m a t e r i a l s w h i c h have two or more carefully d e f i n e d t r a n s i t i o n t e m p e r a t u r e s . J . T. Baker C h e m i c a l Co. 201-859-2151 445 New chiral nmr shift reagent, Eu(TFC)·,, tris[3 - t r i f l u o r o m e t h y l h y d r o x y m e t h y l e n e ) d'-camphorato] e u r o p i u m ( l l l ) , can be used for t h e direct d e t e r m i n a t i o n of e n a n t i o m e r i c c o m p o s i t i o n (optical p u r i t y ) w i t h nuclear m a g n e t i c resonance spec t r o m e t r y . T h e material has been suc c e s s f u l l y a p p l i e d in Eu(TFC) 3 /substrate ratios up to 0.7 to alcohols, k e t o n e s , esters, e p o x i d e s , a n d a m i n e s . $30/ g r a m ; $135/5 g r a m s . Bio-Rad Labora tories. 415-234-4130 446
INSTANT
ESTE
WITH FATTY ACIDS and other organic acids
SPEED — Most leacuuns are complete as soon as solution is achieved. CONVENIENCE — One step procedure; readyto-use reagents in Hypo-vials. ALSO REACTS RAPIDLY WITH AMINES CHOICE OF DERIVATIVE - Methyl, Ethyl, TO FORM " D M A M " DERIVATIVES Propyl, η-Butyl or t-Butyl. t-Butyl esters are These reactions and other interesting chemistry formed as easily as the Methyl. are described and illustrated with gas chroma- QUANTITATION - Quantitative yields are ob tograms in our new 8 page ALKYL-8 BRO tained — even when reagent and sample are in jected without prior mixing. CHURE. (It's free, just ask for it.) These exciting new reagents offer significant Don't forget to ask for ALKYL-8 BROCHURE. advantages over other methods for the prepara PIERCE CHEMICAL COMPANY tion of alkyl esters and other derivatives for gas P.O. Box 117 Rockford, Illinois 61105 U.S.A. phase analysis. PHONE 815/968-0747 TWX 910-631-3419, CIRCLE 1 7 4 O N READER SERVICE CARD
Analytical & Preparative
GEL ELECTROPHORESIS Buchier provides these important, temperature controlled instru ments for separating proteins, hemoglobin, albumin, enzymes and other compounds using polyacrylamide or another supporting medium. For complete informa tion and prices, write for appro priate bulletin.
POLYANALYST Basic analytical unit for separa tion and destaining. Migration takes place in 12 sample col umns. Request Bulletin #3-1750.
POLY-PREP 100 & 200 Preparative instrument for con tinuous fractionation and elution. Request Bulletin #3-1780A.
BUCHLER INSTRUMENTS DIVISION NUCLEAR-CHICAOO CORP. A SUBSIDIARY OF G D I S E A H L E J
β CO.
1327 SIXTEENTH STREET, FORT LEE, NEW JERSEY, 07024 CIRCLE 17 ON READER SERVICE CARD A N A L Y T I C A L CHEMISTRY, VOL. 4 4 , NO. 1 4 , DECEMBER 1 9 7 2
·
81 A