CBS LABORATORIES - Analytical Chemistry (ACS Publications)

CBS LABORATORIES. Anal. Chem. , 1961, 33 (11), pp 124A–124A. DOI: 10.1021/ac60179a743. Publication Date: October 1961. ACS Legacy Archive...
2 downloads 0 Views 273KB Size
NEW PRODUCTS

CBS TYPE 7818 PHOTOMULTIPLIER

DRIERITE NEW DRYING UNIT for AIR & GASES AT PRESSURES up to 90 psig

2 7 / O . D . χ 11 3 /," LABORATORY GAS DRYING UNIT

Low range oxygen analyzer, Model 632C, has dual range design that per­ mits tracking while process is brought into range. It is said to provide analysis within ± 2 % under normal operation, and it is not affected by ! presence of hydrogen or hydrocar­ bons in background gas. The unit operates on the principle of paramag­ netism—oxygen attraction by a mag­ netic field. Hays Corp. P-9

NOW AVAILABLE IN

The redesigned unit will provide exit dew points of — 100°F. and has a heavy duty aluminum cap. Flow rates may be 200 liters per hour.

The 7818 is one of CBS' complete line of photomultipliers; a catalog of detailed specifications is avail­ able on request.

Indicating D R I E R I T E changes from blue to pink when exhausted.

Write for Bulletin 68.

W.A.HAMMOND DRIERITE CO. XENIA, OHIO Circle No. 140 on Readers' Service Card 124 A

·

ANALYTICAL CHEMISTRY

Sensitive to the blue region of the spectrum, this new 3-inch diam­ eter, 10-stage, end-on tube has a plano-concave faceplate to insure uniform sensitivity across its face. Focusing is accomplished by means of a separate electrode to optimize photoelectron collection and to improve resolution. The tube's linear multiplier struc­ ture provides short transit-time spread and fast rise time; shock and vibration specifications of the rugged multiplier structure are guaranteed by CBS.

ACRYLIC PLASTIC

(Specify the plastic model from your Laboratory Supply Dealer.)

For Gamma-Ray Spectrometers, Flying Spot Scanners, and Photo­ metric Instruments

Electronic microphotometer, the NSL | Spec Reader, features the company's digital readout and lock method of automated data presentation. The screen is l 1 / 2 square feet in size, and the company says the operator is able to clearly see the line he is reading and all other lines. Sensitivity is based on full scale deflection with less than 100 square microns. Na­ tional Spectrographic Laboratories, Inc. P-10

Engineers and Physicists: If you are experienced in electron optics or elec­ tronics research and development we invite you to investigate our employ­ ment openings. An Equal-Opportunity Employer.

CBS

LABORATORIES HIGH RIDGE ROAD, STAMFORD, CONNECTICUT

A DIVISION OF COLUMBIA BROADCASTING SYSTEM. INC.

Circle No. 146 on Readers' Service Card