Characteristics of back corona discharge in a honeycomb catalyst and its application for treatment of volatile organic compounds Fada Feng, Yanyan Zheng, Xinjun Shen, Qinzhen Zheng, Shaolong Dai, Xuming Zhang, Yifan Huang, Zhen Liu, and keping yan Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.5b00447 • Publication Date (Web): 05 May 2015 Downloaded from http://pubs.acs.org on May 10, 2015
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 25
Environmental Science & Technology
1
Characteristics of back corona discharge in a honeycomb catalyst and
2
its application for treatment of volatile organic compounds
3
Fada Feng1,2, Yanyan Zheng1, Xinjun Shen1, Qinzhen Zheng1, Shaolong Dai1, Xuming
4
Zhang1, Yifan Huang1*, Zhen Liu1, Keping Yan1
5
1. Key Laboratory of Biomass Chemical Engineering of Ministry of Education,
6
College of Chemical and Biological Engineering, Zhejiang University, Hangzhou
7
310007, People’s Republic of China
8 9
2. School of Chemistry and Environment, Jiaying University, Meizhou 514015, People’s Republic of China
10
Abstract: The main technical challenges for the treatment of volatile organic
11
compounds (VOCs) with plasma-assisted catalysis in industrial applications are large
12
volume plasma generation under atmospheric pressure, by-product control, and
13
aerosol collection. To solve these problems, a back corona discharge (BCD)
14
configuration has been designed to evenly generate non-thermal plasma in a
15
honeycomb catalyst. Voltage-current curves, discharge images, and emission spectra
16
have been used to characterize the plasma. Grade particle collection results and flow
17
field visualization in the discharge zones show not only that the particles can be
18
collected efficiently, but also that the pressure drop of the catalyst layer is relatively
19
low. A three-stage plasma-assisted catalysis system, comprising a dielectric barrier
20
discharge (DBD) stage, BCD stage, and catalyst stage, was built to evaluate toluene
21
treatment performance by BCD. The ozone analysis results indicate that BCD 1
ACS Paragon Plus Environment
Environmental Science & Technology
22
enhances the ozone decomposition by collecting aerosols and protecting the Ag-Mn-O
23
catalyst downstream from aerosol contamination. The GC and FTIR results show that
24
BCD contributes to toluene removal, especially when the specific energy input is low,
25
and the total removal efficiency reaches almost 100%. Furthermore, this removal
26
results in the emission of fewer by-products.
27
TOC Art
28 29
1 Introduction
30
It is proposed that the future applications for plasma-assisted catalysis will most
31
likely be in the treatment of gaseous waste1-4 and in the use of plasma to prepare and
32
modify catalysts5-6. In conventional catalysis, the required activation energy for
33
reactions is supplied in the form of heat, while in plasma-assisted catalysis, the catalyst
34
can be activated directly by plasma, in which only the electrons are energized, and the
35
bulk gas is not significantly heated7. Therefore, the key requirement for these systems
36
is plasma-induced activation of the catalyst at relatively low temperatures. Besides, 2
ACS Paragon Plus Environment
Page 2 of 25
Page 3 of 25
Environmental Science & Technology
37
plasma-assisted catalysis has the potential to enhance global reaction rates, improve
38
reaction selectivity, and increase energy efficiency2. Most of the researches in this field
39
mainly focus on plasma generation8, plasma activation of catalysts9, configuration of
40
plasma combined with catalysts10,11, by-product generation and control12, mechanism
41
of synergistic effects13-16, and reaction kinetics17. Plasma-assisted catalysis for the
42
treatment of VOCs has been studied over two decades, and several excellent reviews
43
have been published in recent years1-3,9,18,19. However, several technical challenges
44
still remain before large-scale industrial application of plasma-assisted catalysis can
45
become practical. Understanding the complex mechanism of synergistic effects and
46
elucidation of the decomposition roadmap of VOCs are widely acknowledged
47
examples of these challenges, but problems associated with large volume plasma
48
generation under atmospheric pressure, by-product control, and aerosol collection
49
must also be addressed.
50
In a one-stage plasma-catalysis configuration such as that seen in a packed-bed
51
reactor, the catalyst is placed in the discharge zone. This allows for a significant
52
synergistic effect, but the relatively high-pressure drop across the catalyst layer is
53
problematic. Employing a honeycomb structured catalyst is a way to lessen the
54
pressure drop, but generating plasma evenly in a honeycomb is difficult. In this work,
55
a hybrid honeycomb configuration comprising a packed bed and capillaries has been
56
used to generate a discharge so that a larger surface area can be obtained with a lower
57
pressure drop20,21. It was also found that this system allowed back corona discharge 3
ACS Paragon Plus Environment
Environmental Science & Technology
58
(BCD) to be successfully employed22-24, which represents an effective method for
59
non-thermal plasma generation and a synergistic plasma catalysis effect25-28. Our
60
research has demonstrated that BCD not only has the potential to activate the catalyst,
61
but also has a further advantage in that aerosols, the major by-product of VOC
62
treatment by the plasma method, can be captured on the catalyst surface and broken
63
down into CO2 and H2O by plasma and catalytic oxidation26. BCD can be easily
64
induced using normal high-voltage DC power sources, which are very reliable and
65
inexpensive, and therefore, it has the potential for application in industrial-scale VOC
66
treatment.
67
In this paper, a BCD reactor capable of evenly generating plasma in a
68
honeycomb catalyst is described. The plasma produced is characterized by reference
69
to voltage-current curves, discharge images, and emission spectra. Grade particle
70
collection efficiency and flow field visualization in the discharge zones are also
71
investigated to gain further understanding of BCD. A three-stage plasma-assisted
72
catalysis system, comprising DBD, BCD, and catalyst, is proposed to evaluate the
73
BCD performance using toluene as a sample VOC. Since DBD is an ideal method to
74
generate ozone that can be used to decompose VOCs29, a DBD is applied in the first
75
stage of the hybrid reactor to generate a high concentration of ozone and partially
76
decompose the toluene. In the second stage, a BCD collects and decomposes the
77
aerosols produced by the DBD, which has the dual purpose of removing aerosol
78
pollution and promoting the treatment in the following catalytic stage. The 4
ACS Paragon Plus Environment
Page 4 of 25
Page 5 of 25
Environmental Science & Technology
79
performance of BCD for ozone generation and decomposition are also described.
80
Finally, the total removal efficiency and product composition are discussed in order to
81
evaluate the hybrid plasma-assisted catalysis method.
82
2 Experimental Section
83
Figure 1(a) shows the experimental setup used in this work, in which the reactor can
84
be regarded as the BCD reactor alone (Figure 1(b)) for plasma characterization,
85
particle collection measurement, and flow field visualization, or as the full three-stage
86
plasma-assisted catalysis system (Figure 1(c)) for toluene decomposition. The
87
experimental setups of particle collection measurement and flow field visualization
88
are described in S1 and S2 of Supporting Information, respectively. As shown in
89
Figure 1(b), the main BCD reactor is arranged in a needles-mesh-honeycomb-mesh
90
configuration. The distance between the needle electrodes and middle mesh, and the
91
middle mesh and bottom mesh is 16 mm and 14 mm, respectively. The discharge
92
electrode is a stainless steel needle with a tip radius of about 0.25 mm, and the mesh is
93
made of nickel foam with a pore density of 110 pores per inch (PPI). The Ag-Mn-O
94
catalyst supported on the honeycomb for BCD generation is prepared by
95
oxidoreduction precipitation. A 400 cell/in2 mesh alumina honeycomb support with a
96
diameter of 100 mm and a thickness of 10 mm was coated with a mixture of Ag-Mn-O
97
and alumina gel, and then calcined at 723 K in air for 4 h. The BCD reactor is placed in
98
a quartz tube with an inner diameter of 120 mm and powered by a negative high-
99
voltage DC power supply. 5
ACS Paragon Plus Environment
Environmental Science & Technology
100
Figure 1(c) shows a schematic diagram of the three-stage plasma-assisted
101
catalysis system, comprising DBD, BCD, and catalyst. The DBD reactor consists of 12
102
cylindrical quartz tubes of around 7 mm inner diameter, 1 mm wall thickness, and 20
103
cm length wrapped in a high-voltage electrode made of copper mesh. Each quartz tube
104
is mounted inside a stainless steel rod to form annular discharge gaps of about 1 mm
105
radial width. The DBD reactor is driven by an AC power source at a frequency of 50 Hz
106
and peak voltage of ±11 kV. In the BCD stage, the configuration is the same as in
107
Figure 1(b). For the catalyst stage, a 400-mesh honeycomb alumina support of 100
108
mm diameter and 20 mm thickness supports 2 g of Ag-Mn-O catalyst. The Ag-Mn-O
109
catalyst here is prepared by a previously described impregnation method26,30. The
110
toluene decomposition experiment was carried out in air with a relative humidity of
111
around 10% at atmospheric pressure and ambient temperature (around 293 K). The
112
initial concentration of toluene was 100 ppm, and the total gas flow rate was 5 L/min.
113
The total discharge volume was around 27.1 cm3, which corresponds to a residence
114
time of 0.33 s. The details of the instruments for electric measurement and gas
115
composition measurement can be found in S3 of Supporting Information. The
116
definitions of toluene removal efficiency, CO selectivity, CO2 selectivity and carbon
117
balance, specific input energy (SIE) and BCD discharge current density are also
118
described in S4 of Supporting Information.
6
ACS Paragon Plus Environment
Page 6 of 25
Page 7 of 25
Environmental Science & Technology
119 120
Figure 1. (a) Schematic diagram of our experimental setup; (b) BCD reactor and (c)
121
hybrid plasma-assisted catalyst for toluene decomposition.
122
3 Results and Discussion
123
BCD discharge images
124
Figure 2 shows the images of the discharge zones for two BCD configurations:
125
needle-mesh-honeycomb-mesh and needle-mesh-capillary quartz tube mesh. Figure
126
2(a) corresponds to the reactor depicted in Figure 1(b). A negative corona discharge
127
and BCD-induced streamers can be observed in the zones near the needle electrodes
128
and between the middle mesh and honeycomb catalyst surface, respectively. To enable 7
ACS Paragon Plus Environment
Environmental Science & Technology
129
visual observation of the discharges inside the honeycomb channels, a bundle of quartz
130
capillaries were used in place of the honeycomb (as shown in Figure 2(b)). The image
131
shows that the plasma is evenly distributed inside the channels of the quartz capillaries.
132
For the similar discharge configuration, it is believed that plasma can also be
133
produced evenly inside the honeycomb channels where the catalysts are supported
134 135
Figure 2. Images of the discharge zones for two BCD configurations: (a)
136
Needle-mesh-honeycomb-mesh (corresponds to the configuration shown in Figure
137
1(b); applied voltage: 30 kV; current density: 11.4 µA/cm2), and (b)
138
needle-mesh-capillary quartz tube mesh (channel diameter: 0.8 mm; applied voltage:
139
26 kV; current density: 6.2 µA/cm2).
140
Voltage-current curves
141
Figure 3 shows the voltage-current curves for BCD and typical corona discharge,
142
in which the discharge occurs at the high-voltage electrode tips without the floated 8
ACS Paragon Plus Environment
Page 8 of 25
Page 9 of 25
Environmental Science & Technology
143
mesh and honeycomb placed downstream. Before BCD occurs, the discharge current is
144
low due to charge accumulation on the honeycomb, which serves as a dielectric layer.
145
The discharge current increases significantly after BCD occurs. When the applied
146
voltage is 30 kV, the discharge current is about 358 µA, which is twice that of a typical
147
corona discharge. This is attributed to the large volume of plasma produced by BCD
148
inside the honeycomb channels.
149 150
Figure 3. Voltage-current curves of normal corona discharge and BCD with a
151
honeycomb.
152
Emission spectra
153
In order to characterize the active species and energy level of the discharges, the
154
emission spectra of the discharge between the middle mesh and the honeycomb surface,
155
as well as the BCD in the honeycomb channels, were measured. The results are shown
156
in Figure 4. Strong emission lines of the second positive system of N2 in the discharge
157
zone were observed at 337.13 nm, 357.69 nm, and 380.49 nm. These lines are similar
158
to those observed in BCD on a fly ash layer31. The emission spectrum from O3
159
(315.61 nm and 336.52 nm, 1B2–X1A1)32-34 can also be observed in this discharge 9
ACS Paragon Plus Environment
Environmental Science & Technology
160
zone. As shown in Figure 4(b), the emission intensity from the honeycomb channels
161
is relatively low, because less light can cross the narrow channels. The emission
162
spectrum of OH (A2Σ → X2Π, (0−0)) is obscured by the emission spectrum of the ∆v
163
= +1 vibration transition band of N2 (C3Πu → B3Πg)31,32,35. Additionally, more
164
reactive radicals such as OH, O, and O3 are produced due to BCD inside the
165
honeycomb channels.
166 167
Figure 4. Emission spectra of the (a) streamer discharge between the middle mesh
168
and the catalyst surface, and (b) BCD in the honeycomb channels. Applied voltage, 30
169
kV; discharge current, 358 µA.
170
Particle collection from BCD
171
In an electrostatic precipitator, BCD is a detrimental phenomenon that decreases the
172
particle collection efficiency36. Fly ash particles collected on the plate will be
173
spattered from the layer and reenter the gas flow when BCD occurs23,24,37. In the
174
treatment of VOCs with BCD, organic aerosols, the major by-product, can adhere to
175
the surface of the catalyst and be decomposed by the plasma-assisted catalysis
176
process26. Figure 5 shows the effect of BCD on the grade collection efficiency of fly 10
ACS Paragon Plus Environment
Page 10 of 25
Page 11 of 25
Environmental Science & Technology
177
ash samples. The initial total particle concentration was 30.9 mg/m3. When BCD
178
occurs, the concentration downstream decreases to 1.86 mg/m3, and the total particle
179
weight removal efficiency is about 94%. It is apparent that most of the particles in the
180
gas phase are collected in the honeycomb, especially the particles with diameters
181
under 1 µm, which matches the diameter range of aerosol particles generated by
182
toluene decomposition with non-thermal plasma, as reported in our previous work38.
183 184
Figure 5. Fine particle collection in the BCD reactor. Applied voltage, 30 kV;
185
discharge current, 358 µA; initial total particle concentration, 30.9 mg/m3; gas flow
186
rate, 10 L/min. The line with solid square points represents the grade weight
187
concentration distribution without BCD. The lines with solid triangle points and soft
188
diamond points represent grade weight concentration downstream and the
189
corresponding grade collection efficiency with BCD, respectively.
190
Flow field distribution
191
The PIV method was used for instantaneous measurement of velocity field
192
distribution without any disturbance to the flow39,40. Figure 6 shows the images of the
193
flow field inside the BCD reactor. Three conditions, i.e., (a) no particles, (b) particles 11
ACS Paragon Plus Environment
Environmental Science & Technology
194
with no discharge, and (c) particles with BCD, are compared. For no discharge, the
195
gas flow is a laminar flow, while intense turbulence with a peak velocity of around 2
196
m/s is generated when BCD occurs. As shown in Figure 6(c), moxa smoke particles
197
are treated by the honeycomb as the area below it is dark, which indicates fewer
198
particles in that area. As the diameter of moxa smoke particles is close to that of the
199
aerosols generated by non-thermal plasma, it can be concluded that the aerosols can
200
also be efficiently treated by BCD. Figure 6(d) shows velocity field distribution
201
averaged over 20 images, and indicates a distinct secondary flow that moves from the
202
needle electrodes toward the honeycomb surface and then passes through the channels.
203
The velocities of the secondary flow upstream and downstream of the honeycomb are
204
around 1–2 m/s and 0.6 m/s, respectively. Compared with other works20,21, it is
205
apparent that the pressure drop of the catalyst bed in this BCD reactor is quite small.
206
The simulation result with computational fluid dynamics software indicates that the
207
pressure drop is around 6 Pa.
12
ACS Paragon Plus Environment
Page 12 of 25
Page 13 of 25
Environmental Science & Technology
208 209
Figure 6. Images of the flow field inside the BCD reactor, (a) with no particles, (b)
210
with particles but no discharge, and (c) particles with BCD. Image (d) shows the flow
211
field distribution calculated with PIV software. Applied voltage, 30 kV; discharge
212
current density, 12.7 µA/cm2.
213
Ozone generation and decomposition
214
Figure 7 shows ozone generation and decomposition in the three-stage
215
plasma-assisted catalysis system vs. the SIE of DBD. The SIE of BCD is fixed at
216
128.9 J/L. The results indicate that the total ozone concentration is linearly dependent
217
on the SIE. Meanwhile, BCD produces additional ozone, but at a much lower rate
218
than DBD. For example, BCD adds only extra 208 ppm ozone when the SIE is 128.9
219
J/L. However, BCD makes a significant contribution to ozone decomposition. For
220
example, when the SIE of DBD is 35 J/L, the ozone decomposition efficiency 13
ACS Paragon Plus Environment
Environmental Science & Technology
221
increases from 97.5% to 99.1% after BCD is turned on. This is because BCD collects
222
the aerosols produced in the previous stage, and, since the aerosols cause deactivation
223
of the catalyst, high catalyst activity is maintained downstream.
224 225
Figure 7. Ozone generation and decomposition of DBD vs. the SIE, where the SIE of
226
BCD is fixed at 128.9 J/L.
227
Toluene removal
228
Figure 8 shows the toluene removal efficiency of the three-stage plasma-assisted
229
catalysis system under four conditions: DBD alone, DBD-BCD, DBD-catalyst, and
230
DBD-BCD-catalyst. The toluene removal efficiency with the DBD-BCD-catalyst
231
system is significantly higher than that achieved with DBD alone or DBD-catalyst,
232
especially when the SIE is low. For example, when the SIE is at 35 J/L, the toluene
233
removal efficiencies in the DBD, DBD-BCD, DBD-catalyst, and DBD-BCD-catalyst
234
are around 37%, 72%, 68%, and 95%, respectively. Furthermore, the energy
235
consumption is almost one order smaller than that reported elsewhere10.
14
ACS Paragon Plus Environment
Page 14 of 25
Page 15 of 25
Environmental Science & Technology
236 237
Figure 8. Toluene removal efficiency vs. the SIE of DBD under four conditions: DBD
238
alone, DBD-BCD, DBD-catalyst, and DBD-BCD-catalyst. The horizontal ordinate
239
refers the SIE of DBD and the SIE of BCD is 128.9 J/L.
240
With regards to plasma induced ozone generation and toluene decomposition, there
241
are three fundamental reactions: R1, R2 and R341,42. According to the results of ozone
242
generation and toluene removal induced by the DBD reactor, they are linearly
243
dependent on each other (Details in S5 of Supporting Information). So, it can be
244
concluded that the two parallel gaseous reactions R2 and R3 almost independently
245
consume O radicals.
246
O radical production:
e + O2 → e + O + O
(R1)
247
O3 generation:
O + O2 + M → O3 + M
(R2)
248
Toluene decomposition: O + C6 H 5 ⋅ CH 3 → product
249
where, M refers to O2 and N2 in air. By using the equations (S1) and (S2) in
250
Supporting Information, the energy yields (in the form of G-values) for ozone
251
generation G(O3) and toluene decomposition G(-toluene) can be calculated about 4.08 15
ACS Paragon Plus Environment
(R3)
Environmental Science & Technology
252
(molecules/100 eV) and 0.40 (molecules/100 eV), respectively.
253
In the DBD-BCD-catalyst system, as shown in emission spectra, BCD produces lots
254
of active species, such as OH, O and N2*. They can be used for toluene and aerosol
255
decomposition. In this stage, aerosol produced in previous DBD stage can be charged
256
and collected on the surface of honeycomb catalyst, then can be decomposed in situ
257
by plasma and catalyst because of the back corona generated in the channel of
258
honeycomb26. So, the catalyst downstream can be protected from aerosol
259
contamination and the three-stage system performs best in toluene removal as shown
260
in Figure 8. The ozone produced in both DBD and BCD is actively used in the
261
catalyst stage. Catalytic ozone oxidation is the most important process for toluene, CO,
262
and other by-products removal. The mechanism of plasma catalysis degradation has
263
already been well studied in our previous works30,41 and others’ works9,12,13,17-19.
264
Gas phase products
265
Figure 9 presents the FTIR spectra of the gaseous product of toluene
266
decomposition using both DBD alone and the DBD-BCD-catalyst system. The results
267
show that by-products such as formaldehyde, formic acid, NOx, ozone, and carbon
268
monoxide are produced during the degradation of toluene by the DBD. However, most
269
of the incompletely decomposed VOCs, carbon monoxide, and ozone are removed
270
when the BCD is turned on and the downstream Ag-Mn-O catalyst works. In the
271
DBD-BCD-catalyst system, the main product of toluene decomposition is CO2 and
272
H2O. 16
ACS Paragon Plus Environment
Page 16 of 25
Page 17 of 25
Environmental Science & Technology
273 274
Figure 9. FTIR spectra of the gas phase product of toluene decomposition with (a)
275
DBD alone and (b) DBD-BCD-catalyst.
276
For plasma-assisted catalysis system, the by-product of NOx can reach several
277
hundred ppm at high SIE of plasma9,11, so it should receive more attention. However,
278
the average SIE of single discharge unit of DBD in this work is quite small, even less
279
than 3 J/L when the total SIE of DBD reaches 35 J/L (12 quartz tubes discharge units).
280
As a result, the NOx produced by DBD is negligible that the concentration of NO2 is
281
0.1 ppm and 0.2 ppm when the SIE of DBD reaches 35 J/L and 64 J/L, respectively.
282
With regards to BCD, the NOx production can also be neglected because the
283
concentration of NO2 is only 1.1 ppm when the SIE of BCD is 128.9 J/L.
284
CO selectivity, CO2 selectivity and carbon balance
285
Figure 10 shows the CO selectivity, CO2 selectivity and carbon balance of the
286
three-stage system in four conditions. The results show that CO2 selectivity and
287
carbon balance are improved when the BCD and catalyst are used. For DBD alone,
288
DBD-BCD, DBD-catalyst, and DBD-BCD-catalyst, the CO2 selectivity is 67 %, 73 %,
289
86 % and 87 %, respectively, and the carbon balance is 41 %, 48 %, 71 % and 82 %,
290
respectively. The higher CO2 selectivity and carbon balance in DBD-BCD-catalyst 17
ACS Paragon Plus Environment
Environmental Science & Technology
process can be attributed to the aerosol decomposed by BCD and the catalytic ozone
292
oxidation of incompletely decomposed VOCs by the catalyst downstream. CO, CO2 selectivity and carbon balance (%)
291
100
CO selectivity CO2 selectivity
Carbon balance
80
60
40
20
0
293
DBD
DBD-BCD
DBD-catalyst DBD-BCD-catalyst
Plasma-assisted catalysis system
294
Figure 10. CO selectivity, CO2 selectivity and carbon balance of the three-stage
295
system in four different conditions: DBD alone, DBD-BCD, DBD-catalyst and
296
DBD-BCD-catalyst. The SIE of DBD and BCD is fixed at 64 J/L and 128.9J/L,
297
respectively.
298
Catalyst degradation
299
For VOCs decomposition with plasma-assisted catalysis, especially two-stage
300
plasma catalysis reactor, the aerosol produced by plasma stage will induce catalyst
301
degradation. The XPS spectrum analysis of the aerosols deposited on catalyst surface
302
show that most carbon in aerosols are in the forms of C-C and/or C-H (59.6 %) and
303
COOH and/or COOR (28.2 %). Details can be found in S6 of Supporting Information.
304
For the three-stage system, BCD placed between DBD and catalyst plays an important
305
role in aerosol collection and decomposition. As shown in Figure 11, the toluene
306
removal efficiency without BCD decreases to below 70 % when operation time 18
ACS Paragon Plus Environment
Page 18 of 25
Page 19 of 25
Environmental Science & Technology
307
increases to 10 hours, but the removal efficiency with BCD remains stable at high
308
level around 98 %. So, the three-stage system is proven to be feasible for industrial
309
application not only for less by-products emission, but also for stable removal
310
efficiency and prolonged lifetime of catalyst.
311 312
Figure 11. The comparison of toluene removal efficiency in DBD-catalyst and
313
DBD-BCD-catalyst with operation time. The SIE values of DBD and BCD are fixed
314
at 64 J/L and 128.9J/L, respectively.
315
Author information:
316
Corresponding author
317
Tel: +86-571-88273897, Fax: +86-571-88210786, E-mail:
[email protected] 318
Notes: The authors declare no completing financial interest
319
Acknowledgments
320
This work is supported financially by the Natural Science Foundation of China (No.
321
21276232,41476080&51377145),
322
Development
323
2013AA065001),
Program
of
Natural
National China
Science
High
(863
Technology
Program)
Foundation
of
19
ACS Paragon Plus Environment
Research
and
(No.2013AA065005, Zhejiang
Province
Environmental Science & Technology
324
(No.LY13E070002& LQ14D060004) and Natural Science Foundation of Guangdong
325
Province (No. 2014A030310196).
326
Supporting Information Available:
327
The experimental setup of the particle collection measurement system for the BCD
328
reactor (S1 text and Figure S1); the experimental setup of the 2D-PIV system for flow
329
field measurement in BCD reactor (S2 text and Figure S2); the details of the electric
330
measurement and gas composition measurement instruments (S3 text); the definitions
331
of toluene removal efficiency, CO and CO2 selectivity, carbon balance, SIE and BCD
332
discharge current density (S4); the analysis of ozone production and toluene
333
decomposition in DBD reactor (S5, Figure S5, Figure S6 and Figure S7); the XPS
334
spectrum analysis of the aerosols deposited on catalyst surface (S6, Figure S8 and
335
Table S1). This information is available free of charge via the Internet at
336
http://pubs.acs.org/.
337
References
338
(1). H. H. Kim, Nonthermal plasma processing for air-pollution control: a historical
339
review, current issues, and future prospects, Plasma Process Polym. 2004, 1 (2):
340
91-110.
341
(2). J. Van Durme, J. Dewulf, C. Leys and H. Van Langenhove, Combining
342
non-thermal plasma with heterogeneous catalysis in waste gas treatment: a review,
343
Appl. Catal. B-Environ. 2008,78 (3-4): 324-333.
344
(3). J. C. Whitehead, Plasma catalysis: a solution for environmental problems, Pure 20
ACS Paragon Plus Environment
Page 20 of 25
Page 21 of 25
Environmental Science & Technology
345
Appl. Chem. 2010,82 (6) : 1329-1336.
346
(4). S. Samukawa, M. Hori, S. Rauf, K. Tachibana, P. Bruggeman, G. Kroesen, J. C.
347
Whitehead, A. B. Murphy, A. F. Gutsol, S. Starikovskaia, U. Kortshagen, J. P.
348
Boeuf, T. J. Sommerer, M. J. Kushner, U. Czarnetzki and N. Mason, The 2012
349
plasma roadmap, J. Phys. D Appl. Phys. 2012,45: 25300125.
350 351 352 353
(5). C. J. Liu, G. P. Vissokov and B. Jang, Catalyst preparation using plasma technologies, Catal. Today 2002,72 (3-4) :173-184. (6). D. G. Cheng, Plasma decomposition and reduction in supported metal catalyst preparation, Catalysis Surveys from Asia 2008,12 (2) : 145-151.
354
(7). H. Winands, K. P. Yan, S. A. Nair, G. Pemen and B. van Heesch, Evaluation of
355
corona plasma techniques for industrial applications: hpps and dc/ac systems,
356
Plasma Process Polym. 2005,2 (3): 232-237.
357
(8). N. Benard, A. Mizuno and E. Moreau, A large-scale multiple dielectric barrier
358
discharge actuator based on an innovative three-electrode design, J. Phys. D Appl.
359
Phys. 2009,42 : 23520423.
360 361 362
(9). H. H. Kim and A. Ogata, Nonthermal plasma activates catalyst: from current understanding and future prospects, Eur. Phys. J.-Appl. Phys. 2011,55: 138061. (10).
N. Jiang, N. Lu, K. Shang, J. Li and Y. Wu, Effects of electrode geometry on
363
the performance of dielectric barrier/packed-bed discharge plasmas in benzene
364
degradation, J. Hazard. Mater. 2013,262 : 387-393.
365
(11).
N. Jiang, N. Lu, K. Shang, J. Li and Y. Wu, Innovative approach for benzene 21
ACS Paragon Plus Environment
Environmental Science & Technology
366
degradation using hybrid surface/packed-bed discharge plasmas, Environ. Sci.
367
Technol. 2013,47 (17) : 9898-9903.
368
(12).
H. B. Huang, D. Q. Ye, D. Leung, F. D. Feng and X. J. Guan, Byproducts and
369
pathways of toluene destruction via plasma-catalysis, J. Mol. Catal. A-Chem.
370
2011,336 (1-2): 87-93.
371
(13).
H. H. Kim, A. Ogata, M. Schiorlin, E. Marotta and C. Paradisi, Oxygen
372
isotope ((18)o(2)) evidence on the role of oxygen in the plasma-driven catalysis
373
of voc oxidation, Catal. Lett. 2011,141 (2): 277-282.
374
(14).
H. H. Kim, J. H. Kim and A. Ogata, Microscopic observation of discharge
375
plasma on the surface of zeolites supported metal nanoparticles, J. Phys. D Appl.
376
Phys. 2009,42 (13): 135210.
377
(15).
Y. F. Guo, D. Q. Ye, K. F. Chen, J. C. He and W. L. Chen, Toluene
378
decomposition using a wire-plate dielectric barrier discharge reactor with
379
manganese oxide catalyst in situ, J. Mol. Catal. A-Chem. 2006, 245 (1-2):93-100.
380
(16).
X. Tu and J. C. Whitehead, Plasma-catalytic dry reforming of methane in an
381
atmospheric dielectric barrier discharge: understanding the synergistic effect at
382
low temperature, Appl. Catal. B-Environ. 2012,125 :439-448.
383
(17).
H. B. Huang, D. Q. Ye and D. Leung, Abatement of toluene in the
384
plasma-driven catalysis: mechanism and reaction kinetics, IEEE T. Plasma Sci.
385
2011,39 (3): 877-882.
386
(18).
H. L. Chen, H. M. Lee, S. H. Chen, M. B. Chang, S. J. Yu and S. N. Li, 22
ACS Paragon Plus Environment
Page 22 of 25
Page 23 of 25
Environmental Science & Technology
387
Removal of volatile organic compounds by single-stage and two-stage plasma
388
catalysis systems: a review of the performance enhancement mechanisms, current
389
status, and suitable applications, Environ. Sci. Technol. 2009,43 (7): 2216-2227.
390
(19).
M. Vandenbroucke, R. Morent, N. De Geyter and C. Leys, Non-thermal
391
plasmas for non-catalytic and catalytic VOC abatement, J. Hazard. Mater.
392
2011,195: 30-54.
393 394 395 396 397
(20).
S. Sato, K. Hensel, H. Hayashi, K. Takashima and A. Mizuno, Honeycomb
discharge for diesel exhaust cleaning, J. Electrostat. 2009,67 (2-3):77-83. (21).
K. Hensel, S. Sato and A. Mizuno, Sliding discharge inside glass capillaries,
IEEE T. Plasma Sci. 2008,36 (4Part 1) :1282-1283. (22).
A. Jaworek, A. T. Sobczyk and E. Rajch, Investigations of dc corona and
398
back discharge characteristics in various gases, Journal of Physics: Conference
399
Series 142(1): 012010.
400 401 402 403 404 405 406 407
(23).
A. Krupa, Laboratory investigations of back discharge in multipoint-plane
geometry in flue gases, J. Electrostat. 2009,67 (2-3) :291-296. (24).
A. Krupa, Back discharge in multipoint-plane geometry in flue gases, Eur.
Phys. J. D 2009,54 (2) :265-270. (25).
T. Czapka, Back-corona discharge phenomenon in the nonthermal plasma
system, IEEE T. Plasma Sci. 2011,39 (11SIPart 1) :2242-2243. (26).
F. D. Feng, L. L. Ye, J. Liu and K. P. Yan, Non-thermal plasma generation by
using back corona discharge on catalyst, J. Electrostat. 2013,71 (3) :179-184. 23
ACS Paragon Plus Environment
Environmental Science & Technology
408 409 410 411 412 413 414
(27).
K. Hensel, Z. Machala and P. Tardiveau, Capillary microplasmas for ozone
generation, Eur. Phys. J.-Appl. Phys. 2009,47: 228132. (28).
K. Hensel, Microdischarges in ceramic foams and honeycombs, Eur. Phys. J.
D 2009,54 (2):141-148. (29).
U. Kogelschatz, Dielectric-barrier discharges: their history, discharge physics,
and industrial applications, Plasma Chem. Plasma P. 2003, 23 (1):1-46. (30).
X. J. Tang, F. D. Feng, L. L. Ye, X. M. Zhang, Y. F. Huang, Z. Liu and K. P.
415
Yan, Removal of dilute vocs in air by post-plasma catalysis over ag-based
416
composite oxide catalysts, Catal. Today 2013,211:39-43.
417
(31).
T. Czech, A. T. Sobczyk and A. Jaworek, Optical emission spectroscopy of
418
point-plane corona and back-corona discharges in air, Eur. Phys. J. D 2011,65 (3) :
419
459-474.
420 421 422
(32).
R.W.B. Pearse and A.G. Gaydon, The identification of molecular spectra,
Chapman and Hall, London, 1976. (33).
M. Villa, M. Calixto-Rodriguez, H. Martinez, J. C. Poveda, P. G. Reyes and P.
423
Altuzar, Asphaltene surface erosion in air plasma, Plasma Science and
424
Technology. 2010,12 (1) :81-86.
425
(34).
S. Stojadinovic, J. Radic-Peric, R. Vasilic, and M. Peric, Spectroscopic
426
investigation of direct current (DC) plasma electrolytic oxidation of zirconium in
427
citric acid, Applied Spectroscopy, 2014,68 (1):101-112.
428
(35).
K.V. Kozlov, H.E. Wagner, R. Brandenburg and P. Michel, Spatio-temporally 24
ACS Paragon Plus Environment
Page 24 of 25
Page 25 of 25
Environmental Science & Technology
429
resolved spectroscopic diagnostics of the barrier discharge in air at atmospheric
430
pressure , J. Phys. D: Appl. Phys. 2001,34(21): 3164–3176.
431 432 433 434 435
(36).
A. Mizuno, Electrostatic precipitation, IEEE T. Dielect. El. In. 2000,7(5):
615-624. (37).
A. Krupa, M. Lackowski and T. Czech, Dust particles motion in back
discharge, Journal of Physics: Conference Series 2008,142(1): 012040. (38).
X. Zhang, F. Feng, S. Li, X. Tang, Y. Huang, Z. Liu, and K. Yan. Aerosol
436
formation from styrene removal with an AC/DC streamer corona plasma system
437
in air. Chemical Engineering Journal. 2013, 232: 527-533.
438
(39).
J. Mizeraczyk, M. Kocik, J. Dekowski, M. Dors, J. Podlinski, T. Ohkubo, S.
439
Kanazawa and T. Kawasaki, Measurements of the velocity field of the flue gas
440
flow in an electrostatic precipitator model using piv method, J. Electrostat.
441
2001,51:272-277.
442 443 444
(40).
J. Westerweel, Fundamentals of digital particle image velocimetry, Meas. Sci.
Technol. 1997,8 (12) :1379-1392. (41).
L. L. Ye, F.D. Feng, J. Liu, X. J. Tang, Y. F. Huang, Z. Liu and K. P. Yan,
445
Toluene decomposition by a two-stage hybrid plasma catalyst system in dry air,
446
IEEE T. Plasma Sci. 2014,42 (11):3529-3538.
447 448
(42).
K. Yan. Corona plasma generation. Eindhoven University of Technology,
Eindhoven, 2001.
25
ACS Paragon Plus Environment