togr. 1984, 295, 55-61. (16) Davies, I. L.; Raynor, M. W.; Williams, P. T.; Andrews, G. E.; Bartle, K. D. Anal. Chem. 1987, 59, 2579-83. (17) Davies, I. L.; Bartle, K. D., Andrews, G. E.; Williams, P. T. J. Chromatogr. Sci. 1988,26(3), 125-30. (18) Grob, K„ Jr.; Stoll, J.-M. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1986, 9, 518-23. (19) Pacciarelli, B.; Mueller, E.; Schneider, R.; Grob, K.; Steiner, W.; Frohlich, D. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1988, 11(1), 13539 (20) Cortes, H. J.; Pfeiffer, C. D.; Richter, B. E. HRC CC, J. High Résolut. Commun. Commun. 1985,8, 469-74. (21) Grob, Κ., Jr.; Neukom, Η. P.; Riekkola, M.-L. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1984, 7, 31926. (22) Bornhop, D. J.; Dovichi, N. J. LC/GC International 1987,1, 80-83. (23) Maris, F. Α.; Noroozian, E.; Otten, R. R.; Van Dijck, R. C ; De Jong, G. J.; Brinkman, U. A. Th. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1988,11, 197-202. (24) Grob, K., Jr.; Neukom, H.; Etter, R. J. Chromatogr. 1986, 357, 416-22. (25) High Performance Liquid Chromatography; Knox, J. H., Ed.; Edinburgh University Press: Edinburgh, U.K., 1978; pp. 198-99. (26) Snyder, L. R. Principles of Adsorption Chromatography; Marcel Dekker: New York, 1968. (27) Grob, K„ Jr.; Schilling, B. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1985, 8, 726-33. (28) Grob, K.; Laubli, Th. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1987,10, 435-40. (29) Munari, F.; Trisciani, Α.; Mapelli, G.; Trestianu, S.; Grob, K., Jr.; Colin, J. M. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1985,8, 601-6. (30) Gianesello, V.; Bolzani, L.; Brenn, E.; Gazzaniga, A. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1988,11(1), 99-102. (31) Davies, I. L.; Raynor, M. W.; Bartle, K.D.; Tolay, M.; Ekinci, E.; Schwartz, H. E. Abstracts of Papers, Pittsburgh Conference and Exposition on Analytical Chemistry and Applied Spectroscopy, New Orleans, La., 1988, Abstract 1227. (32) Apffel, J. Α., Jr.; McNair, H. M. J. Chromatogr. 1983,279,139-44. (33) Noroozian, E.; Maris, F. Α.; Nielen, M.W.F.; Frei, R. W.; De Jong, G. J.; Brinkman, U.A.Th. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1987,10, 17-24. (34) Noy, Th.; Weiss, E.; Herps, T.; Van Chruchten, H.; Rijks, J. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1988,11, 181-86. (35) Sonnefeld, W. J.; Zoller, W. H.; May, W. E.; Wise, S. A. Anal. Chem. 1982, 54, 723-27. (36) Raglione, T. V.; Hartwick, R. A. Abstracts of Papers, Pittsburgh Conference and Exposition on Analytical Chemistry and Applied Spectroscopy, New Orleans, La., 1988, Abstract 773. (37) Schwartz, H. E.; Berry, V. V. LC, Liq. Chromatogr. HPLC Mag. 1985,3(2), 11022. (38) Giddings, J. C. Dynamics of Chromatography, Part I: Principles and Theory; Marcel Dekker: New York, 1965; p. 294. (39) Lee, M. L.; Markides, K. E. Science 1987, 235, 1342-47. (40) Levy, J. M.; Guzowski, J. P.; Huhak, W. E. HRC CC, J. High Résolut. Chromatogr. Chromatogr. Commun. 1987, 10, 337-41. (41) Hawthorne, S. B.; Miller, D. J. J. Chro-
Sample preparation for XRF-AA-ICP-CHEM.
To Bis! or not to
Bis!
That is the question!
claisse
FLUXER® Bis!
The most sophisticated automatic microprocessor controlled fusion apparatus that... - processes almost all kinds of samples - prepares glass disks and solutions - makes six samples at one time - can be modified to make 100 solutions per hour - uses propane or butane, no oxygen. Most competitive pricing. With sale, free training trip to Quebec City. Call or write to the most experienced people on fusion for information.
Corporation
scientifique Claisse
inc.
2522, chemin Sainte-Foy Sainte-Foy (Québec)
£""£«£2 Télex: 051-31731 Fax:(418)656-1169
The First and Finest in Fusion CIRCLE 31 ON READER SERVICE CARD
PHOTOIONIZATION DETECTOR The O.I. Model 4430 PID
• "Hidden" window does not allow sample contact with window • LampSaver circuit prolongs lamp life • Utilizes GC electrometer for unitized operation • Write or call O.I. today for more details
O•I•CORPORATION Graham Rd. at Wellborn Rd. · P.O. Box 2980 · College Station, Texas 77841-2980 Telephone (409) 690-1711 CIRCLE 123 ON READER SERVICE CARD ANALYTICAL CHEMISTRY, VOL. 60, NO. 11, JUNE 1, 1988 · 701 A