Subscriber access provided by GRIFFITH UNIVERSITY
Article
Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current Electrospray Ionization Tandem Mass Spectrometry Xian Fu, Hengxing Liang, Bing Xia, Chunyan Huang, Baocheng Ji, and Yan Zhou J. Agric. Food Chem., Just Accepted Manuscript • DOI: 10.1021/acs.jafc.7b03803 • Publication Date (Web): 31 Aug 2017 Downloaded from http://pubs.acs.org on September 7, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Journal of Agricultural and Food Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 36
Journal of Agricultural and Food Chemistry
1
Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current
2
Electrospray Ionization Tandem Mass Spectrometry
3
Xian Fu†, ‡, Hengxing Liang§, Bing Xia†, *, Chunyan Huang§, Baocheng Ji†, ‡,
4
Yan Zhou†,*
5
†
6
Road, Gaoxin Distinct, Chengdu 610041, P. R. China
7
‡
University of Chinese Academy of Sciences, Beijing 100049, P. R. China
8
§
Chengdu Institute for Food and Drug Control, Chengdu 610045, P. R. China
9
*Corresponding author (Tel: 82890810; E-mail:
[email protected])
Chengdu Institute of Biology, Chinese Academy of Sciences, No. 93 South Keyuan
1
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
10
ABSTRACT
11
A simple and rapid approach for the simultaneous detection of trace amounts of six
12
sulfonamides in chicken muscle was developed using pulsed direct current electrospray
13
ionization tandem mass spectrometry (pulsed-dc ESI-MS/MS). The pretreatment of
14
chicken muscle samples consisted of two steps, acetonitrile extraction and n-hexane
15
delipidation. Sulfonamides do not need to be derivatized or chromatographed prior to
16
pulsed-dc ESI-MS/MS. The factors affecting the performance of pulsed-dc
17
ESI-MS/MS were studied. Under optimum conditions, the quantitative performance of
18
pulsed-dc ESI-MS/MS was validated according to European Union Decision
19
2002/657/EC, and the sensitivity of pulsed-dc ESI-MS/MS was three times higher than
20
that of ultra-high-performance liquid chromatography-tandem mass spectrometry
21
(UPLC-MS/MS). The limits of detection obtained by pulsed-dc ESI-MS/MS were in
22
the range of 0.07-0.11µg/kg. The proposed method was simple, rapid, and sensitive,
23
and was successfully used for quantitation and rapid screening of sulfonamides in real
24
chicken muscle samples.
25 26
KEYWORDS: pulsed-dc ESI-MS/MS, UPLC-MS/MS, sulfonamides, chicken muscle,
27
European Union Decision 2002/657/EC, quantitation, rapid screening
28
2
ACS Paragon Plus Environment
Page 2 of 36
Page 3 of 36
Journal of Agricultural and Food Chemistry
29
INTRODUCTION
30
Sulfonamides are widely used in stockbreeding as a cheap but effective antibiotic.
31
Due to excessive use, sulfonamide residues in agricultural products are also
32
increasingly common, which is harmful to food security and to public health.1 The
33
European Union has set a maximum residue limit (MRL) for sulfonamides in food at
34
the level of 100 µg/kg.2 The current methods of detecting sulfonamide residues in food
35
include
36
chromatography,7-8
37
(LC-MS/MS).2, 9-12 The sensitivity of microbial assay is relatively low and can produce
38
inaccurate results. Employing immunoassays is tedious, and the detection is too
39
specific to be used for multi-analytes analysis. In addition, sulfonamides need to be
40
derivatized prior to fluorometric, spectrophotometric, and gas chromatographic
41
detection, which increases the workload. When using LC and LC-MS/MS, the
42
development of LC method is a prerequisite.
microbiological and
methods,3 liquid
immunoassays,4-5
chromatography-tandem
spectrophotometry,6 mass
spectrometry
43
To overcome the deficiencies of above mentioned methods, ambient ionization mass
44
spectrometry methods have been developed in recent years. Starting from desorption
45
electrospray ionization,13 over forty ambient ionization methods have been presented.14
46
Ambient ionization methods have the advantages of operating in situ,15 in real-time,16
47
on-line,17 with high sensitivity18 and high throughput.19 Among them, constant voltage
48
pulsed direct current electrospray ionization (pulsed-dc ESI),20 as a typical
49
representative of high sensitivity ionization techniques, was first reported in 2015. 3
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
50
Pulsed electrospray is generated at a capillary emitter tip when direct current voltage is
51
applied to the electrode positioned close to, but not touching, a sample solution.
52
Pulsed-dc ESI produces long signal durations without losing detection sensitivity. At
53
present, there are few reports about the application of ambient ionization methods in the
54
quantitative analysis of compounds. Studies on ambient ionization are mainly focused
55
on qualitative analysis and the development of new ionization methods. So far, the
56
application of pulsed-dc ESI for quantitative analysis has not been reported.
57
The objective of this study was to develop a sensitive method for rapid screening and
58
quantitation of sulfonamides in food samples without the use of chromatographic
59
separation or derivatization. UPLC-MS/MS and pulsed-dc ESI-MS/MS were
60
compared. Sulfonamide residues in real chicken muscle samples were quantitated using
61
this new presented technique.
62 63
MATERIALS AND METHODS
64
Chemicals and materials
65
The standards of sulfadimethoxine, 1, sulfameter, 2, sulfamethazine, 3, sulfathiazole,
66
4, sulfamethoxazole, 5, and sulfadiazine, 6, were obtained from Dr. Ehrenstorfer
67
(Augsburg, Germany). Their structures are shown in Figure 1. n-Hexane of analytical
68
grade was purchased from Kelong Chemical Reagent Factory (Chengdu, China).
69
Chromatographic grade methanol and acetonitrile were purchased from Fisher
70
(Pittsburgh, PA). Ultrapure water was obtained from a Milli-Q water system (Millipore, 4
ACS Paragon Plus Environment
Page 4 of 36
Page 5 of 36
Journal of Agricultural and Food Chemistry
71
Billerica, MA). The borosilicate glass capillaries (0.6 mm i.d., 1.0 mm o.d., without
72
filament) were purchased from Narishige Co. Ltd. (Tokyo, Japan). The steel electrode
73
(0.3 mm o.d.) was bought from a local hardware store (Chengdu, China). Stock
74
solutions of sulfonamides at a concentration of 1.0 mg/mL were prepared monthly in
75
methanol and stored at -18 °C.
76 77
Apparatus
78
UPLC-MS/MS was performed on an Acquity UPLC system combined with an
79
electrospray ionization source (ESI) on a Xevo TQ triple quadrupole mass spectrometer
80
(Waters, Milford, MA). The chromatographic column used was a 100 mm x 2.1 mm i.d.,
81
1.6 µm, Cortecs UPLC C18 (Waters, Milford, MA).
82 83
Sample
84
A total of about 80 samples from different traders were employed. Blank samples
85
were confirmed to be free of sulfonamides by pulsed-dc ESI-MS/MS and
86
UPLC-MS/MS applying the following procedures. Standard solution of sulfonamides
87
was spiked into the blank samples for method validation.
88 89
Sample treatment
90
Sample treatment was basically in accordance with the national standards of P. R.
91
China (GB/T 21316-2007) (2007).21 5 g of homogenized chicken muscle samples 5
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
92
were accurately weighed and transferred into a round-bottomed flask followed by 20
93
mL of acetonitrile to extract the analytes. The liquid was sucked out after being
94
vortexed for 2 min and sonicated for 5 min; the precipitate was extracted with
95
additional of 20 mL of acetonitrile. Then the liquid was combined and concentrated to 5
96
mL by a rotary evaporator at 40 °C. 4 mL of acetonitrile saturated n-hexane was added
97
to the supernatant to remove fat by 2 min sonication. The n-hexane layer was discarded
98
after 10,000 rpm centrifuge for 3 min, and the acetonitrile layer was evaporated to
99
dryness. Additional acetonitrile (20 mL) was added to dissolve the sulfonamides by
100
manual shaking and stirring for 2 min, in such case the fat and protein on the flask
101
wall would not be dissolved. The solution was transferred to a new round-bottomed
102
flask prior to repeat evaporation and dissolution by 10 mL of acetonitrile twice.
103
Finally, there was no fat and protein on the flask wall. For UPLC-MS/MS analysis,
104
the residues were dissolved with 2 mL of methanol/water (1:9, v/v) and filtered
105
through a 0.22 µm filter membrane, and then 10 µL of the solution was injected into
106
the UPLC system. Prior to pulsed-dc ESI-MS/MS detection, the remaining residues
107
were dissolved in 2 mL of methanol. After filtration through a 0.22 µm filter
108
membrane, 0.6 µL of the solution was loaded onto the capillary emitter tip.
109 110
UPLC-MS/MS conditions
111
The mobile phase was composed of A (0.3% aqueous formic acid) and B
112
(acetonitrile) at a flow rate of 0.3 mL/min.22 The column temperature was kept at 6
ACS Paragon Plus Environment
Page 6 of 36
Page 7 of 36
Journal of Agricultural and Food Chemistry
113
40 °C, and the following gradient procedure was applied: linear change from 5-40% B
114
during the first 6 min, 40-95% B over 1 min, held at 95% B for 1 min, then decreased
115
to 5% B in 1 min. Multiple-reaction monitoring (MRM) mode was used for mass
116
spectrometry data acquisition under positive ionization mode. In addition, the
117
capillary voltage was 2.5 kV and desolvation temperature was 500 °C. The
118
desolvation and cone gas flow rate were set at 500 L/h and 2 L/h, respectively. Under
119
such condition, the retention times were found to be 2.23, 2.51, 3.24, 3.41, 4.35 and
120
5.32 min for 6, 4, 3, 2, 5, 1, respectively.
121 122
Determination of sulfonamides by pulsed-dc ESI under MRM mode
123
Borosilicate glass capillaries (0.6 mm i.d., 1.0 mm o.d.) were pulled by PC-10 puller
124
(Narishige, Tokyo, Japan) to fabricate spray emitters. The internal diameter of the tip
125
was 20 µm. Based on the size of the emitter, a self-made 3D-printed insulating holder
126
was built to mount the emitter. 0.6 µL of solution was loaded onto the emitter tip by
127
micropipettor. A steel electrode with a diameter of 0.3 mm was inserted straight into the
128
emitter from its rear portion. The distance from the tip of electrode to sample solution
129
was 1 mm and the emitter tip to mass spectrometer inlet was 5 mm. A direct current of
130
4.0 kV was applied to the electrode to produce electric field for electrospray generation.
131
Spray solvent was methanol. Schematic of the pulsed-dc ESI system is shown in Figure
132
2. All manipulations of the pulsed-dc ESI were performed on a three-dimensional
133
mobile platform, which increased the repeatability and stability of the experiment 7
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
Page 8 of 36
134
operation. Taking into account the accuracy of the results, 3 was selected as the internal
135
standard for quantitation of other five sulfonamides. The MRM parameters were
136
consistent with the UPLC-MS/MS condition. Since pulsed-dc ESI is an ambient
137
ionization technique, the capillary voltage and desolvation gas flow were zero. Other
138
instrument settings were not changed.
139 140
Validation study
141
Method validation was performed according to the European Union regulation
142
2002/657/EC.23 The following parameters were evaluated: selectivity, linearity, limit
143
of detection (LOD), limit of quantitation (LOQ), decision limit (CCα), detection
144
capability (CCβ), precision, accuracy, stability, and robustness. Linearity was assessed
145
by matrix-matched calibration curve. CCα and CCβ were calculated by the standard
146
deviations of the within-laboratory reproducibility. Precision and accuracy were
147
investigated at three concentrations (0.5, 1.0 and 1.5 MRL).
148
sulfonamides in chicken muscle investigated at 4 °C and -18 °C. In additional, seven
149
small changes was deliberately introduced into experiment process to evaluated
150
robustness.
The stability of
151 152
RESULTS AND DISCUSSION
153
The primary objective and challenge in method development was to find a suitable
154
set of conditions that could generate stable signal while achieving optimal sensitivity. 8
ACS Paragon Plus Environment
Page 9 of 36
Journal of Agricultural and Food Chemistry
155
The optimized parameters were the diameter of the emitter tip, the solvent system, the
156
distance from the electrode to the solution, and the spray voltage. A 0.6 µL aliquot of a
157
standard sulfonamide solution at a concentration of 10 ng/mL was used to optimize the
158
parameters. All data was collected in MRM mode.
159 160
Inner diameter of emitter tip
161
In the ionization process, pulsed-dc ESI has a similar ionization mechanism to ESI.
162
After droplets experienced Taylor cone formation and coulomb explosion, gas ions
163
were emitted from the emitter tip.24 It has been proven that better sensitivity could be
164
achieved by reducing the size of the emitter tip.25 The inner diameter of the capillary tip
165
was 1-3 µm, which could produce a flow rate of 20 to 30 nL/min. Droplet diameters
166
decreased as the spray flow rate decreased. Smaller droplets were more desirable
167
because of their larger charge-to-volume ratios, which facilitated the formation of gas
168
ions. However, small diameter nozzle had a drawback of clogging. We found that even
169
the presence of bubbles during the sample loading process might prevent the generation
170
of spray, disturb continuous signal, or block the nozzle, which was not conducive to
171
obtaining stable data. As the tip diameter decreased, the chances of the tip being
172
blocked were multiplied. Hence, after balancing the operational feasibility, stability and
173
detection sensitivity, a spray emitter tip with a diameter of 20 µm was chosen, which
174
was also the common size of nanoelectrospray tip.26
175 9
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
176
Spray solvent
177
It has been demonstrated that droplet generation and fragmentation are strongly
178
influenced by solvent surface tension. It is noteworthy that reducing the surface tension
179
does not necessarily enhance the response of the sample in the mass spectrometer,
180
because the solution surface tension can simultaneously affect the charge density on the
181
surface of the droplet. For this reason, the influence of solvents on sulfonamide signal
182
intensity was investigated in detail. Tests were performed by varying the ratio of
183
methanol to water as follows: 0:10, 3:7, 5:5, 7:3, 9:1, and 10:0. As presented in Figure
184
3A, larger methanol ratios increased the ion signal intensity. When the spray solvent
185
was pure water, the signal durations were much longer than that of pure methanol,
186
while the signal intensity was much weaker. This is because the surface tension of water
187
is too large to be conducive to forming gas ions. In theory, the sulfonamides are
188
derivatives of p-aminobenzene sulfonamide, thus adding formic acid would improve
189
ionization efficiency. However, in our experiments, no obvious change in MRM signal
190
intensity was observed after adding 0-0.3% (v/v) formic acid to the methanol.
191
In addition, mixtures of 50% methanol and three organic solvents for electrospray
192
were tested, including acetonitrile,27 dichloromethane,28 and isopropanol29 (Figure 3B).
193
Because the viscosity (η(cp)) of isopropanol (2.437) is much greater than methanol
194
(0.597), dichloromethane (0.43) and acetonitrile (0.360), which is not conducive to
195
spraying, the lowest signal intensity was obtained in methanol/isopropanol (5:5, v/v).
196
Since dichloromethane and acetonitrile were aprotic solvents that could not provide 10
ACS Paragon Plus Environment
Page 10 of 36
Page 11 of 36
Journal of Agricultural and Food Chemistry
197
protons to charge the compounds, the signal intensity in pure methanol was higher than
198
that in dichloromethane/methanol (5:5, v/v) and acetonitrile/methanol (5:5, v/v).
199
Therefore, pure methanol was used for the following experiments. In addition, due to
200
the low boiling point of dichloromethane, in the process of dichloromethane
201
gasification, water vapor in the nearby air was more likely to be condensed and
202
involved in the ionization process;30 the signal in dichloromethane/methanol (5:5, v/v)
203
was merely 10% lower than that in methanol.
204 205
Distance from electrode to solution
206
The distance from electrode to solution played an important part in this work. In
207
consideration of ionization efficiency and operational controllability, the distance
208
between the electrode and solution was varied from 5 to 1 mm to avoid coming into
209
contact with the solution. As the electrode approached the solution, the signal strength
210
also increased accordingly (Figure 3C). It is worth noting that shortening the distance
211
did not lead to shorter signal durations. Thus, 1 mm was selected as the experimental
212
distance. For comparison, inserting the electrode of 0.3 mm diameter directly into the
213
solution was also evaluated. However, the sample solution either adhered to the
214
electrode or squeezed out from the capillary tip, leading to severe sample loss; the
215
advantages of using pulsed-dc ESI without contacting the solution were noted by the
216
absence of these problems.
217 11
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
218
Spray voltage
219
Studies had shown that increasing the voltage within a certain range could promote
220
droplet formation and fragmentation. The droplet radius decreased as the spray voltage
221
increased, making gas phase ions more likely to be generated. We therefore conducted a
222
series of investigations varying spray voltages from 1.0 to 4.5 kV (Figure 3D). When
223
the voltage was lower than 2.0 kV, the ionization signal was rather weak; however, 2.0
224
kV was enough to ionize analytes in common nanospray methods.31 This phenomenon
225
might be caused by two reasons. Firstly, the electrode was 1 mm away from the solution,
226
and consequently the electric field actually applied to the solution was reduced.
227
Another reason was that the diameter of the nozzle tip (20 µm) was larger than the
228
diameter of the capillary tip (1-3 µm). Theoretically, the required spray voltage
229
increases as the nozzle diameter increases. In our experiment, when the applied voltage
230
increased from 2.0 to 3.0 kV, there was a noticeable improvement in signal intensity.
231
Further increasing the voltage caused slight signal enhancement. The signal intensity of
232
4.0 kV was merely 1.5% stronger than that of 3.5 kV. The signal strength dropped
233
slightly as higher voltages were applied, which indicated that voltage had a limit to its
234
effect on promoting the ionization process. To achieve maximum detection sensitivity,
235
4.0 kV was chosen as the optimal spray voltage.
236 237 238
Method validation Both methods were validated in accordance with the European Commission 12
ACS Paragon Plus Environment
Page 12 of 36
Page 13 of 36
Journal of Agricultural and Food Chemistry
239
Decision 2002/657/EC in terms of selectivity, linearity, LOD, LOQ, CCα, CCβ,
240
repeatability, inter-day reproducibility, accuracy, stability and robustness.
241
Specificity means the ability of a method to measure the analytes accurately in the
242
presence of matrix interferences. 20 blank chicken muscle samples from different
243
traders were analyzed by both methods; due to the efficient clean-up step and high
244
selectivity provided by MRM, no matrix interference was found. However, the
245
undetected matrix components may enhance or suppress the signals of analytes. In
246
order to evaluate the matrix effect, calibration curves of solvent and chicken muscle
247
extract were constructed in the range of 5-1000 ng/mL, respectively. By comparing
248
the slope of the standard curve of solvent and chicken muscle extracts, the matrix
249
suppression effect for UPLC-MS/MS and pulsed-dc ESI-MS/MS were 2.5-9.1% and
250
7.9-13.7%, respectively. When the matrix effect was in the range of -20% to 20%, the
251
effect was considered small.32 The small matrix effect may be caused by the efficient
252
clean-up step and insensitivity of sulfonamides to matrix.2, 22, 33 To quantitate more
253
accurately, the matrix-matched calibration curve was employed.
254
Calibration curves were constructed using spiked chicken muscle samples with
255
least-squares linear regression model. For UPLC-MS/MS, the calibration curves for
256
six sulfonamides were established by plotting the peak areas versus the concentrations
257
of analytes, and the spiked level were 0, 2, 4, 20, 40, 80, 200, and 400 µg/kg. For
258
pulsed-dc ESI-MS/MS, 3 was used as the internal standard, and the concentration was
259
40 µg/kg. The calibration curves for five sulfonamides were established by plotting 13
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
260
the peak area ratio of analytes to internal standard versus the concentrations of
261
analytes. Satisfactory linearity was obtained, with correlation coefficients greater than
262
0.9966 (Table 1). In the European Commission Decision 2002/657/EC, LOD and
263
LOQ were replaced with CCα and CCβ. Therefore, LOD and LOQ were determined
264
according to the International Conference on Harmonisation of Technical
265
Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines.34
266
LOD was the lowest concentration that could be reliably detected but not required to
267
be quantitated, with the signal-to-noise ratio over 3:1; LOQ was the lowest level that
268
could be reliably quantitated with relative standard deviation (RSD) less than 20%,
269
and the signal-to-noise ratio over 10:1. The results in Table 1 showed that the LODs
270
of UPLC-MS/MS and pulsed-dc ESI-MS/MS for sulfonamides were in the range of
271
0.20-0.32 µg/kg and 0.07-0.11 µg/kg, respectively, which were far below the MRL set
272
by European Union. Representative MRM chromatograms of spiked chicken muscle
273
samples are shown in Figure 4. The sensitivity of pulsed-dc ESI-MS/MS was about
274
three times higher than that of UPLC-MS/MS. There might be three reasons why
275
pulsed-dc ESI-MS/MS was more sensitive than UPLC-MS/MS. First, the inner
276
diameter of capillary tip of pulsed-dc ESI was smaller than that of commercial ESI;
277
ionization efficiency increased as the diameter of the tip decreased. Second, the spray
278
tip of commercial ESI was perpendicular to the mass spectrometer inlet; while the
279
spray tip of pulsed-dc ESI was horizontally aligned with the mass spectrometer inlet,
280
improving the ion transport efficiency. In addition, the spray tip of pulsed-dc ESI was 14
ACS Paragon Plus Environment
Page 14 of 36
Page 15 of 36
Journal of Agricultural and Food Chemistry
281
only 5 mm away from the 150 °C inlet,which was conducive to the vaporization of
282
charged droplets.
283
Decision limit (CCα) and detection capability (CCβ) are parameters used to
284
determine whether the sample is compliant. If the content in a sample is at and above
285
CCα, the sample can be regarded as non-compliant with an error of α. 20 blank
286
samples spiked with permitted limit concentration (100 µg/kg) were used for CCα
287
measurement. It was calculated as the permitted limit concentration plus 1.64 times
288
the corresponding standard deviations of the within-laboratory reproducibility (α =
289
5%). If the content in a sample is at CCβ, the sample can be detected and quantitated
290
with an error of β. CCβ was calculated as CCα plus 1.64 times the corresponding
291
standard deviations of 20 samples spiked at CCα (β = 5%). The CCα obtained by
292
both methods was close to MRL value (Table 1), indicating the detection error α was
293
small.
294
Precision experiments were performed at three concentrations (0.5, 1.0 and 1.5
295
MRL). The precision was evaluated by intra-day and inter-day RSDs. Intra-day RSDs
296
were obtained from six replicates within one day. Inter-day precision was performed
297
by six replicates within one day and for three consecutive days. As shown in Table 2,
298
all RSDs obtained by both methods were lower than 15%, indicating the repeatability
299
and stability of pulsed-dc ESI-MS/MS was comparable to that of UPLC-MS/MS.
300
However, the RSD value of pulsed-dc ESI-MS/MS was a little higher than that of
301
UPLC-MS/MS. Because any detection technique used for quantitative analysis was 15
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
302
very demanding and the electrospray ionization was susceptible to environment, the
303
stability of closed ionization was slightly better than that of ambient ionization.
304
Accuracy was assessed by the recovery of three concentrations (0.5, 1.0 and 1.5
305
MRL) and six replicates were performed at each level. The recovery was calculated
306
by the ratio of measured mass to spiked mass. The mean recoveries obtained by
307
UPLC-MS/MS and pulsed-dc ESI-MS/MS were in the range of range of 87.4-101.3%
308
and 88.4-99.0%,respectively (Table 2), which fully fulfilled the criteria of -20% to 10%
309
set in the European Commission Decision 2002/657/EC.
310
Spiked chicken muscle samples at the concentration of 100 µg/kg were used for
311
stability test. The results showed that sulfonamides could be saved in 4 °C for 24 h or
312
-18 °C for three days. No sulfonamides were stable for a week, which may be because
313
sulfonamides were degraded by the microbes that bred from chicken muscle.
314
Robustness refers to the susceptibility of a method to the minor differences in the
315
experiment. For pulsed-dc ESI-MS/MS, the variables from sample treatment to
316
detection were evaluated. Seven parameters were vortex time (1.8, 2.2 min),
317
sonication time for extraction (4.5, 5.5 min), volume of acetonitrile for extraction (19,
318
21 mL), volume of n-hexane (3.5, 4.5 mL), brand of methanol (Fisher, Merck), spray
319
voltage (3.95, 4.05 kV) and distance from electrode to solution (0.9, 1.1 cm). The
320
results showed that those parameters had no significant effect on robustness. However,
321
we found that the morphology and inner diameter of the emitter tip had influence on
322
the results. This may be due to the fact that there was a process of ion migration 16
ACS Paragon Plus Environment
Page 16 of 36
Page 17 of 36
Journal of Agricultural and Food Chemistry
323
during spraying, and the morphologies of the spray tip affected the migration of ions
324
differently. In addition, the diameter of the spray tip had different effects on the
325
ionization efficiency of each compound. Therefore, the spray condition of each
326
detection should be controlled.
327 328
Comparison with other detection methods
329
The most important advantage of the proposed method was simplicity, rapidity, and
330
sensitivity. The detection could be performed within 3 min, much faster than
331
spectrophotometry, enzyme-linked immunosorbent assay (ELISA), and liquid
332
chromatography. For example, 10 min was needed for the derivation of sulfonamides
333
with p-dimethylaminocinnamaldehyde before spectrophotometric determination,6, 35 at
334
least 2 h was needed for ELISA,4 and the detection time of HPLC (/UPLC) ranged
335
from 10-40 min.2, 36-37 The LOD of the proposed method (0.07-0.11 µg/kg) was lower
336
than other reported methods, such as enzyme-linked immunosorbent assay
337
(0.04-0.2 µg/g),4 HPLC with fluorescence detection (1.15-2.73 µg/kg),38 and
338
LC-MS/MS (0.43-1.22 µg/kg).33 In addition, satisfactory linearity, precision, accuracy,
339
CCα and CCβ were obtained, indicating pulsed-dc ESI-MS/MS had sufficient
340
performance to be a new candidate for sulfonamide rapid screening and quantitation.
341 342 343
Analysis of real samples To verify the practicability of the proposed method, sulfonamide residues in six 17
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
344
chicken muscle samples from three sales environments were determined by
345
UPLC-MS/MS and pulsed-dc ESI-MS/MS. Two of the samples were positive;
346
detection rate was 33.3%. The results of the two methods were similar. Detection
347
deviations of the two methods were less than 12%, indicating the quantitative
348
performance of pulsed-dc ESI-MS/MS was reliable. The residues did not exceed MRL
349
(100 µg/kg). MRM chromatograms of a positive sample are shown in Figure 5. 1 and 2
350
were detected in both samples, probably because 1 is widely used for the prevention
351
and treatment chicken coccidiosis, infectious rhinitis, avian cholera, Kaposi's disease,
352
and 2 is also a broad-spectrum antibacterial agent.22 Interestingly, the two positive
353
samples were purchased in a worse environment than the other four samples. Perhaps,
354
the quality of a sample from a better sales environment is more assured.
355
In this work, pulsed-dc ESI, as a new kind of quantitative ambient ionization
356
method, was applied to the rapid screening of sulfonamide residues in chicken muscle
357
samples. Sulfonamides did not need to be derivatized or chromatographed prior to
358
pulsed-dc ESI-MS/MS. The operation of pulsed-dc ESI was simple, and rapid. When
359
pulsed-dc ESI-MS/MS was used to detect sulfonamides in chicken muscle samples,
360
the results fulfilled the criteria in Commission Decision 2002/657/EC. In addition, the
361
sensitivity of pulsed-dc ESI-MS/MS were three times higher than that of
362
UPLC-MS/MS, which was of great significance for the detection of sulfonamide
363
residues in food. Overall, pulsed-dc ESI-MS/MS could be regarded as an option for
364
sensitive, rapid screening and quantitative analysis of sulfonamides in food samples. 18
ACS Paragon Plus Environment
Page 18 of 36
Page 19 of 36
Journal of Agricultural and Food Chemistry
365
ASSOCIATED CONTENT
366
Supporting Information
367
Determination of sulfonamide residues in milk samples with pulsed-dc ESI-MS/MS.
368
Table S1: Mass spectrometer characteristics of six sulfonamides. Table S2: Detection
369
results of sulfonamide residues in chicken muscle samples. Figure S1: MRM
370
chromatograms of a blank sample of (A) UPLC-MS/MS and (B) pulsed-dc
371
ESI-MS/MS. Figure S2: Matrix effects of sulfonamides in chicken muscle. Figure S3:
372
The sulfonamide MS/MS fragmentation patterns of the [M+H]+. Figure S4: The
373
MS/MS mass spectra of sulfonamides.
374
This material is available free of charge via the Internet at http://pubs.acs.org.
375 376
AUTHOR INFORMATION
377
Corresponding authors s
378
*E-mail address:
[email protected];
[email protected] 379 380
Notes
381
The authors declare no competing financial interest.
382 383
ABBREVIATIONS USED
384
pulsed-dc ESI-MS/MS, pulsed direct current electrospray ionization tandem mass
385
spectrometry; UPLC-MS/MS, ultra-high-performance liquid chromatography-tandem 19
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
386
mass spectrometry; MRL, maximum residue limit; LOD, limit of detection; LOQ
387
limit of quantitation; CCα, decision limit; CCβ, detection capability.
388 389
ACKNOWLEDGMENTS
390
Dr. Yan Zhou received funding from the National Natural Sciences Foundation of
391
China (21572221), and Dr. Bing Xia received funding from the National Natural
392
Sciences Foundation of China (21672206).
20
ACS Paragon Plus Environment
Page 20 of 36
Page 21 of 36
Journal of Agricultural and Food Chemistry
393
REFERENCES
394
(1) Wang, L. L.; Wu, J.; Wang, Q.; He, C. H.; Zhou, L.; Wang, J.; Pu, Q. S. Rapid and
395
sensitive determination of sulfonamide residues in milk and chicken muscle by
396
microfluidic chip electrophoresis. J. Agric. Food Chem. 2012, 60, 1613-1618.
397
(2) Hu, S.; Zhao, M.; Xi, Y.; Mao, Q.; Zhou, X.; Chen, D.; Yan, P. Nontargeted
398
screening and determination of sulfonamides: a dispersive micro solid-phase
399
extraction approach to the analysis of milk and honey samples using liquid
400
chromatography-high-resolution mass spectrometry. J. Agric. Food Chem. 2017, 65,
401
1984-1991.
402
(3) Chung, H. H.; Lee, J. B.; Chung, Y.-H.; Lee, K. G. Analysis of sulfonamide and
403
quinolone antibiotic residues in Korean milk using microbial assays and high
404
performance liquid chromatography. Food Chem. 2009, 113, 297-301.
405
(4) Jimenez, V.; Adrian, J.; Guiteras, J.; Marco, M. P.; Companyo, R. Validation of an
406
enzyme-linked immunosorbent assay for detecting sulfonamides in feed resources. J.
407
Agric. Food Chem. 2010, 58, 7526-31.
408
(5) Hu, G. S.; Sheng, W.; Zhang, Y.; Wang, J. P.; Wu, X. N.; Wang, S. Upconversion
409
nanoparticles
410
fluorescence immunoassay for the detection of sulfaquinoxaline in animal-derived
411
foods. J. Agric. Food Chem. 2016, 64, 3908-3915.
412
(6) Dmitrienko, S. G.; Kochuk, E. V.; Tolmacheva, V. V.; Apyari, V. V.; Zolotov, Y. A.
413
Determination of the total content of some sulfonamides in milk using solid-phase
and
monodispersed
magnetic
polystyrene
21
ACS Paragon Plus Environment
microsphere
based
Journal of Agricultural and Food Chemistry
414
extraction coupled with off-line derivatization and spectrophotometric detection.
415
Food Chem. 2015, 188, 51-56.
416
(7) Niu, H.; Cai, Y.; Shi, Y.; Wei, F.; Liu, J.; Mou, S.; Jiang, G. Evaluation of carbon
417
nanotubes as a solid-phase extraction adsorbent for the extraction of cephalosporins
418
antibiotics, sulfonamides and phenolic compounds from aqueous solution. Anal. Chim.
419
Acta 2007, 594, 81-92.
420
(8) Tarbin, J.A.; Clarke, P.; Shearer, G. Screening of sulphonamides in egg using gas
421
chromatography-mass-selective
422
spectrometry. J. Chromatogr. B 1999, 729, 127-138.
423
(9) Berardi, G.; Bogialli, S.; Curini, R.; Di Corcia, A.; Lagana, A. Evaluation of a
424
method for assaying sulfonamide antimicrobial residues in cheese: Hot-water
425
extraction and liquid chromatography-tandem mass spectrometry. J. Agric. Food
426
Chem. 2006, 54, 4537-4543.
427
(10) Sheridan, R.; Mirabile, J.; Hafler, K. Determination of six illegal antibiotics in
428
chicken jerky dog treats. J. Agric. Food Chem. 2014, 62, 3690-6.
429
(11) Tso, J.; Dutta, S.; Inamdar, S.; Aga, D. S. Simultaneous analysis of free and
430
conjugated estrogens, sulfonamides, and tetracyclines in runoff water and soils using
431
solid-phase extraction and liquid chromatography-tandem mass spectrometry. J. Agric.
432
Food Chem. 2011, 59, 2213-22.
433
(12) Reybroeck, W.; Jacobs, F. J.; De Brabander, H. F.; Daeseleire, E. Transfer of
434
sulfamethazine from contaminated beeswax to honey. J. Agric. Food Chem. 2010, 58,
detection
and
liquid
22
ACS Paragon Plus Environment
chromatography-mass
Page 22 of 36
Page 23 of 36
Journal of Agricultural and Food Chemistry
435
7258-65.
436
(13) Takats, Z.; Wiseman, J. M.; Gologan, B.; Cooks, R. G. Mass spectrometry
437
sampling under ambient conditions with desorption electrospray ionization. Science
438
2004, 306, 471-473.
439
(14) Peacock, P. M.; Zhang, W. J.; Trimpin, S. Advances in ionization for mass
440
spectrometry. Anal. Chem. 2017, 89, 372-388.
441
(15) Chen, H.; Yang, S.; Wortmann, A.; Zenobi, R. Neutral desorption sampling of
442
living objects for rapid analysis by extractive electrospray ionization mass
443
spectrometry. Angew. Chem. Int. Ed. 2007, 119, 7735-7738.
444
(16) Bai, Y.; Zhang, J.; Bai, Y.; Liu, H. Direct analysis in real time mass spectrometry
445
combined with single-drop liquid-liquid-liquid microextraction for the rapid analysis
446
of multiple phytohormones in fruit juice. Anal. Bioanal. Chem. 2012, 403, 2307-14.
447
(17) Chang, C.; Xu, G.; Bai, Y.; Zhang, C.; Li, X.; Li, M.; Liu, Y.; Liu, H. Online
448
coupling of capillary electrophoresis with direct analysis in real time mass
449
spectrometry. Anal. Chem. 2013, 85, 170-6.
450
(18) Gong, X.; Xiong, X.; Wang, S.; Li, Y.; Zhang, S.; Fang, X.; Zhang, X. Desalting
451
by crystallization: detection of attomole biomolecules in picoliter buffers by mass
452
spectrometry. Anal. Chem. 2015, 87, 9745-51.
453
(19) Huang, G.; Li, G.; Cooks, R. G. Induced nanoelectrospray ionization for
454
matrix-tolerant and high-throughput mass spectrometry. Angew. Chem. Int. Ed. 2011,
455
50, 9907-9910. 23
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
456
(20) Wei, Z.; Xiong, X.; Guo, C.; Si, X.; Zhao, Y.; He, M.; Yang, C.; Xu, W.; Tang, F.;
457
Fang, X.; Zhang, S.; Zhang, X. Pulsed direct current electrospray: enabling systematic
458
analysis of small volume sample by boosting sample economy. Anal. Chem. 2015, 87,
459
11242-8.
460
(21) Determination of residues of sulfonamides in foodstuffs of animal origin:
461
LC-MS/MS.
462
Inspection and Quarantine of the People’s Republic of China, 2007.
463
(22) Shen, Q.; Jin, R.; Xue, J.; Lu, Y.; Dai, Z. Analysis of trace levels of sulfonamides
464
in fish tissue using micro-scale pipette tip-matrix solid-phase dispersion and fast
465
liquid chromatography tandem mass spectrometry. Food Chem. 2016, 194, 508-15.
466
(23) Commission Decision (EC) No. 657/2002 of 12 August 2002 implementing
467
Council Directive 96/23/EC concerning the performance of analytical methods and
468
the interpretation of results. Off. J. Eur. Comm. 2002, L221, 8-36.
469
(24) Vanberkel, G. J.; Zhou, F. M. Electrospray as a controlled current electrolytic
470
cell-electrochemical ionization of neutral analytes for detection by electrospray
471
mass-spectrometry. Anal. Chem. 1995, 67, 3958-3964.
472
(25) Korner, R.; Wilm, M.; Morand, K.; Schubert, M.; Mann, M. Nano electrospray
473
combined with a quadrupole ion trap for the analysis of peptides and protein digests. J.
474
Am. Soc. Mass Spectrom. 1996, 7, 150-156.
475
(26) Huang, G.; Li, G.; Ducan, J.; Ouyang, Z.; Cooks, R. G. Synchronized inductive
476
desorption electrospray ionization mass spectrometry. Angew. Chem. Int. Ed. 2011, 50,
GB/T 21316-2007; General Administration of Quality Supervision,
24
ACS Paragon Plus Environment
Page 24 of 36
Page 25 of 36
Journal of Agricultural and Food Chemistry
477
2503-6.
478
(27) Hu, B.; Xin, G. Z.; So, P. K.; Yao, Z. P. Thin layer chromatography coupled with
479
electrospray ionization mass spectrometry for direct analysis of raw samples. J.
480
Chromatogr. A 2015, 1415, 155-60.
481
(28) Espy, R. D.; Teunissen, S. F.; Manicke, N. E.; Ren, Y.; Ouyang, Z.; van Asten, A.;
482
Cooks, R. G. Paper spray and extraction spray mass spectrometry for the direct and
483
simultaneous quantification of eight drugs of abuse in whole blood. Anal. Chem. 2014,
484
86, 7712-8.
485
(29) Wang, Q.; Zheng, Y.; Zhang, X.; Han, X.; Wang, T.; Zhang, Z. A silica coated
486
paper substrate: development and its application in paper spray mass spectrometry for
487
rapid analysis of pesticides in milk. Analyst 2015, 140, 8048-56.
488
(30) Wu, M. X.; Wang, H. Y.; Zhang, J. T.; Guo, Y. L. Multifunctional carbon fiber
489
ionization mass spectrometry. Anal. Chem. 2016, 88, 9547-9553.
490
(31) Wang, H.; Liu, J.; Cooks, R. G.; Ouyang, Z. Paper spray for direct analysis of
491
complex mixtures using mass spectrometry. Angew. Chem. Int. Ed. 2010, 49, 877-80.
492
(32) Hoyos, O. D.; Cuartas, O. Y.; Penuela, M. G. Development and validation of a
493
highly sensitive quantitative/confirmatory method for the determination of ivermectin
494
residues in bovine tissues by UHPLC-MS/MS. Food Chem. 2017, 221, 891-897.
495
(33) Kung, T. A.; Tsai, C. W.; Ku, B. C.; Wang, W. H. A generic and rapid strategy for
496
determining trace multiresidues of sulfonamides in aquatic products by using an
497
improved QuEChERS method and liquid chromatography-electrospray quadrupole 25
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
498
tandem mass spectrometry. Food Chem. 2015, 175, 189-96.
499
(34) Eriksen, J. N.; Madsen, P. L.; Dragsted, L. O.; Arrigoni, E. Optimized,
500
fast-throughput UHPLC-DAD based method for carotenoid quantification in spinach,
501
serum, chylomicrons, and feces. J. Agric. Food Chem. 2017, 65, 973-980.
502
(35) Tolmacheva, V. V.; Apyari, V. V.; Yarykin, D. I.; Dmitrienko, S. G.
503
Spectrophotometric determination of the total concentration of sulfonamides in milk
504
after adsorption separation using magnetic hypercrosslinked polystyrene. Anal. Chem.
505
2016, 71, 834-839.
506
(36) Malintan, N. T.; Mohd, M. A. Determination of sulfonamides in selected
507
Malaysian swine wastewater by high-performance liquid chromatography. J.
508
Chromatogr. A 2006, 1127, 154-60.
509
(37) Zotou, A.; Vasiliadou, C. LC of sulfonamide residues in poultry muscle and eggs
510
extracts using fluorescence pre-column derivatization and monolithic silica column. J.
511
Sep. Sci. 2010, 33, 11-22.
512
(38) Arroyo-Manzanares, N.; Gamiz-Gracia, L.; Garcia-Campana, A. M. Alternative
513
sample treatments for the determination of sulfonamides in milk by HPLC with
514
fluorescence detection. Food Chem. 2014, 143, 459-64.
515
26
ACS Paragon Plus Environment
Page 26 of 36
Page 27 of 36
Journal of Agricultural and Food Chemistry
516
FIGURE CAPTIONS:
517
Figure 1. Structures of the sulfonamides studied: sulfadimethoxine, 1; sulfameter, 2;
518
sulfamethazine, 3; sulfathiazole, 4; sulfamethoxazole, 5; sulfadiazine, 6.
519
Figure 2. Schematic of the pulsed-dc ESI.
520
Figure 3. Optimization of the pulsed-dc ESI. (A) and (B) Solvent composition.
521
Distance from electrode to sample solution, 2 mm; Spray voltage, 2.8 kV. (C) Distance
522
from electrode to solution. Spray solvent, methanol; Spray voltage, 2.8 kV. (D) Spray
523
voltage. Distance from electrode to solution, 1 mm; Spray solvent, methanol.
524
Figure 4. (A) UPLC-MS/MS MRM chromatograms of the spiked sample (400 µg/kg),
525
(B) Pulsed-dc ESI-MS/MS MRM chromatograms of the spiked sample at the
526
concentration of 40 µg/kg.
527
Figure 5. MRM chromatograms of a real sample by (A) UPLC-MS/MS and (B)
528
pulsed-dc ESI-MS/MS.
27
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
Page 28 of 36
Table 1. Calibration Curves, LOD, LOQ, CCα and CCβ for Sulfonamides. analyte
linear range (µg/kg)
regression equation
correlation coefficient
LOD (µg/kg)
LOQ (µg/kg)
CCα (µg/kg)
CCβ (µg/kg)
107.6
UPLC-MS/MS a
1
0-400
y = 409.10x + 1156.7
0.9991
0.20
0.60
103.7
2
0-400
y = 136.84x – 98.56
0.9985
0.32
1.00
103.7
106.4
3
0-400
y = 276.94x – 731.66
0.9973
0.24
0.72
104.2
106.8
4
0-400
y = 215.33x + 25.226
0.9988
0.26
0.84
103.5
107.8
5
0-400
y = 121.89x + 13.271
0.9989
0.32
1.00
104.6
108.1
6
0-400
y = 194.54x + 472.84
0.9984
0.26
0.84
104.3
107.6
1
0-400
yb = 0.0414x + 0.1971
0.9989
0.07
0.21
104.8
108.8
2
0-400
y = 0.0122x + 0.0702
0.9976
0.09
0.28
102.8
106.5
4
0-400
y = 0.0130x + 0.0578
0.9987
0.09
0.28
103.4
107.0
5
0-400
y = 0.0081x + 0.0517
0.9983
0.11
0.33
101.4
105.6
6
0-400
y = 0.0127x + 0.1003
0.9966
0.09
0.28
104.5
107.5
pulsed-dc ESI-MS/MS
a
b
y, the peak areas of analytes; y, the peak area ratio of analytes to internal standard; x, the concentration of analytes (µg/kg).
28
ACS Paragon Plus Environment
Page 29 of 36
Journal of Agricultural and Food Chemistry
Table 2. Results of Recovery and Precision for Sulfonamides. 0.5 MRL analyte recovery (%) RSDra (%)
RSDRb (%)
1.0 MRL recovery (%) RSDr (%) RSDR (%) UPLC-MS/MS (n=6)
recovery (%)
1.5 MRL RSDr (%)
RSDR (%)
1
92.3
10.1
6.9
95.1
8.0
6.7
88.1
8.1
7.2
2
98.6
9.5
7.0
90.9
6.2
7.7
87.4
6.8
9.0
3
95.3
5.4
5.6
94.6
7.6
8.9
93.1
7.4
8.8
4
96.9
5.8
6.9
91.7
6.7
7.9
92.7
7.0
7.2
5
93.8
6.3
5.4
101.3
6.0
9.9
90.3
7.4
9.8
6
92.6
8.0
8.3
90.6
5.3
6.1
91.7
6.9
8.8
pulsed-dc ESI-MS/MS (n=6) 1
92.8
9.1
8.4
92.3
8.5
9.6
88.4
8.9
8.3
2
99.0
8.0
10.3
93.3
10.0
10.5
89.3.
10.8
9.7
4
92.3
9.2
8.6
93.6
7.6
8.7
91.5
9.1
9.0
5
98.9
10.7
10.9
98.8
9.1
11.7
92.8
7.4
10.1
6
95.6
9.8
11.4
91.8
8.8
10.1
92.6
9.5
10.8
a
b
RSDr, the RSD of repeatability; RSDR, the RSD of inter-day reproducibility.
29
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
Figure 1
30
ACS Paragon Plus Environment
Page 30 of 36
Page 31 of 36
Journal of Agricultural and Food Chemistry
Figure 2
31
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
Figure 3
32
ACS Paragon Plus Environment
Page 32 of 36
Page 33 of 36
Journal of Agricultural and Food Chemistry
Figure 3 (continued)
33
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
Figure 4
34
ACS Paragon Plus Environment
Page 34 of 36
Page 35 of 36
Journal of Agricultural and Food Chemistry
Figure 5
35
ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
Table of Contents Graphic
36
ACS Paragon Plus Environment
Page 36 of 36