DIONEX CORPORATION

The IC 16 contains two complete systems, each capable of oper- ating independently or in ... (443) 8801-8. Canada. 416-675-3872. Netherlands. (020) 43...
0 downloads 0 Views 959KB Size
HAVE Y O U RECEIVED YOUR

1980 GENERAL CATALOG

DION ANALYSIS • 1M m I I V 1

SIMULTANEOUS ANALYSIS OF ANIONS AND CATIONS Almost any ion with pK < 7 can be analyzed by ion chromatography. Matrix effects are minimized in IC by using sample dilution as the only pretreatment. The extraordinary sensitivity of the IC has been applied to the analysis of inorganic anions such as F~, C I " S042~, aliphatic carboxylic acids such as formate and acetate, phosphonic, and small aliphatic sulfonic acids. Monovalent cation or divalent cation analyses are easily performed with separate sample injection onto different columns.

FOR T H E F I N E S T COMMERCIALLY AVAILABLE

BUY DIRECT in ANY QUANTITY FROM THE MANUFACTURER

The unique dual system IC 16 enables the analyst to simultaneously determine a wide variety of ions with a single sample injection. The IC 16 contains two complete systems, each capable of operating independently or in a coupled mode. Use of different column sets in the two systems allows numerous possibilities for simultaneous ion analysis. Among these are: • anion and monovalent cation analysis • aliphatic carboxylic acids and inorganic anion analysis • aliphatic carboxylic acids and monovalent cations • monovalent and divalent cations • coupled analysis for increased specificity in anion analysis

A) Strong Acids (CI", NO,-, SO,2", etc.) B) Unknown C) Tartaric A

D) Malic E) Lactic F) Succinc or Formic G) Acetic H) Propionic

Call for details of: J u n e Seminar Schedule in Utah, Colorado, Wyoming, New Mexico a n d California Symposium o n Ion Chromatography at 2 2 n d R o c k y M o u n t a i n C o n f e r e n c e , Denver, August 11-14, 1980.

Circle the reader service number for applications and product data

0

4

8

12 16 20 24 28 Minutes

Simultaneous Determination of Organic Acids and Cations in Red Wine (100 fold dilution) Application Note 21

CIRCLE 54 ON READER SERVICE CARD

"Analytical Chemicals Since 1928"

G. FREDERICK S M I T H CHEMICAL C O M P A N Y 867 McKinley Ave. Columbus.Ohio 43223

C M ' n o * 'r'«"i«l " 224-5343

B

CIRCLE 203 ON READER SERVICE CARD

DIONEX DIONEX CORPORATION 1228 Titan Way, Sunnyvale, CA 94086 USA, 408-737-0700, Telex: US Regional Offices: Woodbridge, NJ, 201-634-1127* Bensenville, IL, 312-860-1030 International Telephone Hotlines: Italy Australia (02) 736-2088 Japan Belgium (031)55 85 51 Netherlands Canada 416-675-3872 Norway Denmark (1) 452 910333 Spain Finland (90)42 91 France (1) 644 00 95 Sweden Switzerland Germany (089) 807095-98 United Kingdom Israel (3)248213-4-5

348347

(02) 4983951 (443) 8801-8 (020) 43 36 51 (2) 671533 (91) 215 69 41 08-63 1470 061-23-5210 0276 26373