Dionex Corporation

5 Br. 0.08. 6 CIO? 0.14. 7. no: 42.11. 8.I1PO*-'. 0.17. 9 SOr. 5.00. Column: lonPac AS9. Eluant: Na>CO?/NaH(X>? Detection: Suppressed Conductivity. DI...
0 downloads 0 Views 1009KB Size
Clean solutions for troubled waters. Environmental sample * Oxy-Halides Detection in Drinking Watert Adequate separation between the chlorate and nitrate peaks could not be achieved with past anion columns The new IonPac AS9 column provides the resolution needed for reliable detection of chlorite and chlorate. Peaks ppm if 5.66 2. Clo; 0.50 3. CI" 45.45 4. N O ; O.O6 5. Br" 0.08 6 CIO", 0.14 7. NO:< 42.11 8. HrW' 0.17 9. SO42" 5.00 Column: IonPac AS9 Eluant Na.COj/NaHCOî Detection: Suppressed Conductivity

matrices can be hazard­ ous to your productivity If you're struggling to detect water contaminants at the required levels, you'll be glad to know Dionex has an easier way Crash the ppb barrier in complex matrices. Alkali and alkaline earth metals rob ICP spec­

with chemically sup-

troscopy of its sensitivity

pressed conductivity

for measuring transition

detection, does the job

metals in sea water—

in one easy run.

unless you do a lot of Series 4500i.

sample prepping.

The right solutions.

Couple Dionex Che­

Right now.

lation Ion Chromatog­ raphy to an ICP spec­

Direct Metals Detection

trometer and get those fractional ppb levels

in Sea Water'

Detection Limit (ppb) Direct Metal

with a direct introduc­

Nebulization

Concentration

Cd

10

0.1

Co

10

0.1

Cu

10

0.1

Fe

10

0.1

or acid digest sample.

Mn

5

0.1

Ni

10

0.1

Pb

50

0.9

Zn

10

0.1

of chromium in

2

ι with background correction 211 ml. concentrated

'1C/ICP under Em review

Dionex Chelation IC provides a 100-fold in ICP detection limits.

capacity ion exchange column,

water is not unlike a needle in

non-metallic postcolumn

a haystack: so elusive, it devours

chemistry, and photometric

your time.

detection, you'll get 0.1 ppb

incorporating a very high-

need Dionex. Find out how

single run.

Dionex columns and the Series

How do you measure oxy-

4500i Systems can solve your

halides in drinking water to the

environmental analysis prob-

required 0.1 ppm? Until now,

lems—wet or dry Contact your

with great difficulty and not

local Dionex representative or

much reliability: Fortunately,

(in USA) call

the new, highly selective Dionex

1-800-227-1817, ext.42 today.

improvement

Hexavalent chromiumt in waste

With our new IC method,

and chlorate in a

IonPac® AS9 column, combined

a bucket of interferences.

When you want solutions, you

Chelation 1

tion of your sea water

Find a drop

Determine chlorite

Series 4500i Ion Chromatograph

DIONEX

sensitivity and no interferences

A BETTER SOLUTION

in a 6-minute analysis.

tMelhod under ERA review Dionex Corporation. EO. Box 3603, Sunnyvale, CA 94088-3603, Canada Dionex Canada, Ltd., (416) 620-0077, England Dionex (LK) Ltd., (276) 691722, West Germany Dionex GmbH, (612) 66036, France Dionex S.A., (1) 4621-6666, Italy Dionex S.r.l., (06) 3792979, Netherlands Dionex BV. (76) 714800, 0 1989 Dionex Corporation

CIRCLE 34 ON READER SERVICE CARD