Subscriber access provided by University of Glasgow Library
Article
Enhancing the mass spectrometry sensitivity for oligonucleotides detection by organic vapor assisted electrospray Guofeng Weng, Zheyi Liu, Jin Chen, Fangjun Wang, Yuanjiang Pan, and YuKui Zhang Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.7b01695 • Publication Date (Web): 05 Sep 2017 Downloaded from http://pubs.acs.org on September 6, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
Enhancing the mass spectrometry sensitivity for oligonucleotides
2
detection by organic vapor assisted electrospray
3
Guofeng Weng1,2, Zheyi Liu2,3, Jin Chen2,3, Fangjun Wang2*, Yuanjiang Pan1*, Yukui Zhang2
4
1
Department of Chemistry, Zhejiang University, Hangzhou, 310027, China.
5
2
CAS Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical
6
Physics, Chinese Academy of Sciences, Dalian, 116023, China.
7
3
8
* Correspondence and requests for materials should be addressed to F.W. (email:
[email protected])
9
and Y.P. (email:
[email protected]).
University of Chinese Academy of Sciences, Beijing, 100049, China.
10 11
ABSTRACT
12
There are two challenges in oligonucleotides detection by liquid chromatography coupled with mass
13
spectrometry (LC-MS), the serious ion suppression effects caused by ion-pair reagents and the low
14
detection sensitivity in positive mode MS. In this study, highly concentrated alcohol vapors were
15
introduced into an enclosed electrospray ionization chamber and oligonucleotides could be well
16
detected in negative mode MS even with 100 mM triethylammonium acetate (TEAA) as ion-pair
17
reagent. The MS signal intensity was improved 600 folds (for standard oligonucleotide dT15) by the
18
isopropanol vapor assisted electrospray and effective ion-pair LC separation was feasibly coupled with
19
high-sensitive MS detection. Then, oligonucleotides were successfully detected in positive mode MS
20
with little adducts by propanoic acid vapor assisted electrospray. The signal intensity was enhanced
21
more than 10 folds on average compared with adding acids into the electrospray solution. Finally,
22
oligonucleotides and peptides or histones were simultaneously detected in MS with little interference to
23
each other. Our strategy provides a useful alternative for investigating the biological functions of
24
oligonucleotides.
25 26
INTRODUCTION
27
Nucleic acids (DNA and RNA) sequencing technologies have been greatly developed in recent years
28
and even single cell sequencing has been realized1. Comparing with the nucleic acids sequencing
29
technologies coupled with polymerase chain reaction (PCR), mass spectrometry (MS) can provide rich
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
30
information of post-modifications on nucleotides, which play essential roles in biological processes2,3.
31
Further, oligonucleotides gain increasing attention due to their extensive usages in many biological and
32
therapeutic applications such as small RNA interference (siRNA)4. Therefore, new MS-based strategies
33
are still needed for high-sensitive, high-accurate and high-throughput characterization of
34
oligonucleotides. There are two challenges existed in MS detection of oligonucleotides. The first one is
35
the serious MS signal suppression effect of ion-pair reagents which makes the commonly utilized
36
ion-pair reversed-phase liquid chromatography (IP-RPLC) incompatible to MS detection. The second
37
one is the low sensitivity of oligonucleotides in positive mode MS detection due to their highly
38
negative backbone with abundant phosphodiester groups. Thus, it is difficult to simultaneously detect
39
oligonucleotides with other biomolecules that usually detected in positive mode MS, such as peptides
40
and proteins.
41
Triethylammonium acetate (TEAA) is one of the most popular ion-pair reagents in
42
oligonucleotides separation due to its high efficiency in improving the separation capability of RPLC5-7.
43
Oberacher et al. achieved single nucleotide resolution oligonucleotides separation by using the TEAA
44
containing mobile phase8. Dickman et al. demonstrated that IP-RPLC with TEAA enabled
45
size-dependent separation of duplex DNA up to 458bp9,10. Although commonly utilized 100 mM TEAA
46
could significantly improve the IP-RPLC separation resolution, it will seriously suppress MS signals at
47
the same time11. Recently, Gong et al. demonstrated that 30 mM TEAA delivered an optimal balance
48
between IP-RPLC separation efficiency and MS detection sensitivity after sophisticated optimization of
49
the LC separation conditions12. Other strategies for alleviating the MS signal suppression effect of
50
TEAA include removing TEAA ions by micro-dialysis before the mobile phase enters into ESI-MS13,
51
post-column addition of organic solvent as sheath liquid to improve MS signal14,15, and utilizing
52
hexafluoroisopropanol (HFIP) coupled with triethylamine (TEA) to instead of TEAA buffer11. However,
53
these strategies will either introduce post-column dead volume and dilute the sample concentration or
54
diminish the LC separation resolution especially for large oligonucleotides14,16.
55
In this study, we demonstrated that the MS detection sensitivity for oligonucleotides could be
56
significantly enhanced by organic vapors (alcohols and acids) assisted electrospray ionization within an
57
enclosed ESI source (Figure 1 and S1). Briefly, the signal suppression effect of 100 mM TEAA was
58
significantly alleviated by introducing concentrated alcohol vapor into the enclosed electrospray
59
chamber, and effective ion-pair RPLC separation was directly coupled with high-sensitive MS
ACS Paragon Plus Environment
Page 2 of 19
Page 3 of 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
60
detection without any other purification or dilution procedures. Then, high-sensitive oligonucleotides
61
detection in positive mode MS was achieved by organic acid vapor assisted electrospray. More
62
importantly, oligonucleotides and peptides or histones were simultaneously detected in positive mode
63
MS with high sensitivity, which exhibited great potential in investigating the biological processes of
64
gene regulation by related proteins.
65 66
EXPERIMENTAL SECTION
67
Chemicals, proteins and oligonucleotides samples.
68
Chemical reagents of TEA, triethylammonium bicarbonate (TEAB), propanoic acid (PA), acetic acid
69
(HAc), trifluoroacetic acid (TFA), formic acid (FA), trypsin (TPCK treated), bovine serum albumin
70
(BSA) were obtained from Sigma (St. Louis, MO). HPLC grade of acetonitrile (ACN), methanol and
71
isopropanol were from Merck (Darmstadt, Germany). Deionized water used in all experiments was
72
purified with a Milli-Q system from Millipore (Milford, MA). Histone proteins were from Worthington
73
(Lakewood, USA). All of the oligonucleotides samples were purchased from Sangon Biotech
74
(Shanghai, China) (Table S1).
75
The tryptic digest of BSA was prepared according to our previous work with minor modification17.
76
The 2 mg of BSA was dissolved into 1 mL of denaturing buffer containing 8 M urea and 0.1 M
77
ammonium bicarbonate. After addition of 20 µL DTT (1 M), the mixture was incubated at 37 ℃ for 2
78
h. Then, 7.4 mg IAA was added, and the mixture was incubated at room temperature in dark for 40 min.
79
Finally, the mixture was diluted 8 folds with 0.1 M ammonium bicarbonate buffer (pH 8.2) and
80
digested at 37 ℃ for 20 h with trypsin at enzyme-substrate ratio of 1/25 (w/w). After digestion, the pH
81
of digested solution was adjusted to 2.7 by 10% TFA aqueous solution, followed with purification by a
82
homemade C18 solid-phase extraction (SPE) column. Finally, the eluted peptides was lyophilized and
83
stored at -20 ℃ before usage.
84
RPLC-MS analysis.
85
According to the reported method18, TEAA buffer (100 mM, pH7) was prepared by mixing appropriate
86
amounts of TEA and HAc in mobile phases A (5% ACN and 95% H2O) and B (45% ACN and 55%
87
H2O) respectively. Briefly, for 200 mL of 100 mM TEAA buffer, 1.1 mL of glacial acetic acid was
88
added into 180 mL mobile phase A or B, and then 2.8 mL of TEA was slowly added with stirring and
89
ice bath cooling. The pH of the resulting solution was carefully adjusted to pH 7.0 by addition of either
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
90
TEA or HAc.
91
All of the LC-MS and direct infusion MS analyses were performed on a LTQ-Orbitrap XL MS
92
equipped with Accela 600 HPLC system (Thermo, San Jose, CA). The LC separation system includes a
93
4 cm C18 capillary trap column (200 µm i.d.) and a 20 cm C18 capillary separation column (75 µm i.d.)
94
packed with C18 AQ beads (5 µm, 120Å)19,20. The oligonucleotides mixtures were firstly loaded onto
95
C18 trap column and then separated by IP-RPLC with gradient elution. The flow rate after splitting was
96
adjusted to about 200 nL/min. The RP gradient was developed as follows: 0% buffer B (100 mM
97
TEAA, 45% ACN and 55% H2O, pH 7.0) for 5 min, from 0 to 30% buffer B for 25 min, from 30 to
98
80% for 12 min. After elution with 80% buffer B for 8 min, the separation system was equilibrated by
99
buffer A (100 mM TEAA, 5% ACN and 95% H2O, pH 7.0) for 10 min.
100
A commercial open ambient nano-spray source (Thermo) and an enclosed electrospray source
101
(CEESI, Haochuang, China)21-23 were utilized in MS experiments, respectively. Electrospray voltage
102
between the spray tip and the MS interface was 2.0 kV, the temperature of ion transfer capillary was
103
250 ℃, the max inject time was 100 ms, microscans 1 and the MS1 resolution was 30,000 (at m/z =
104
400). System control and data collection were carried out by Xcalibur software version 2.1 (Thermo).
105
For the mixture of oligonucleotides and histone proteins detection, the max inject time was 250 ms and
106
microscans 20 to further improve the MS resolution.
107
Organic vapor introduction
108
The CEESI source has an enclosed chamber created by seamlessly connecting to the heated ion transfer
109
capillary of MS (Figure 1 and S1). The source has two interfaces, one of them is used to fix LC
110
capillary column for sample introduction and the other one is used for organic vapor introduction by
111
absorbing air through a removable gas-washing bottle containing different organic solvents with the
112
help of the high vacuum of MS. Thus, the atmosphere in the enclosed electrospray chamber is
113
concentrated organic vapor and can be adjusted through changing airflow rate and the type of organic
114
solvents in the gas-washing bottle. Moreover, this source can also work in open ambient condition after
115
removing the gas-washing bottle.
116 117
RESULTS AND DISCUSSION
118
Alleviating MS signal suppression effect of TEAA on oligonucleotides detection
119
Firstly, signal intensity (sum of the peak intensity of all individual charge states) of 10 µM
ACS Paragon Plus Environment
Page 4 of 19
Page 5 of 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
120
oligonucleotide dT15 (in 45% ACN) with TEAA concentration varying from 10 to 100 mM was
121
investigated in direct ESI-MS detection (negative mode) with an open ambient nanoESI source (Figure
122
2 and S2). Along with the increase of TEAA from 0 to 100 mM, the charge-state distribution of
123
oligonucleotide dT15 shifted to lower charge states and its MS signal intensity was significantly
124
decreased due to the ion suppression effect of TEAA (Figure S3). Oligonucleotide signal was nearly
125
disappeared when TEAA reached to 50 mM in sample solution. Then a variety of concentrated organic
126
vapors including isopropanol, ethanol, methanol and acetonitrile were doped into the enclosed ESI
127
chamber, respectively, to investigate the related influences on MS detection signals of 10 µM
128
oligonucleotide with 100 mM TEAA. Obviously, all of these four organic vapors could significantly
129
improve the signal intensity of oligonucleotide and the MS signal was disappeared as soon as the
130
organic vapor was removed (Figure 3a). Among them, isopropanol and ethanol vapors exhibited higher
131
efficiency in improving oligonucleotide signal intensity (Figure S4). The good reproducibility of
132
isopropanol vapor assisted electrospray was demonstrated through direct infusion MS detection with
133
five consecutive connecting and disconnecting the isopropanol vapor introduction flow path every 30
134
seconds (Figure 3b). Then, we systematically investigated the performance of isopropanol vapor
135
(consumption rate, 142 µL(liquid)/min) on enhancing the oligonucleotide signal intensity with TEAA
136
concentration varying from 10 to 100 mM. Concentrated isopropanol vapor assisted electrospray could
137
efficiently alleviate the signal suppression caused by TEAA. The signal enhancement ratio
138
(Iisopropanol/Iambient) was increased from 3.5 to 50.0 along with the TEAA concentration increasing from
139
10 to 100 mM (Figure 2). We further investigated the signal intensity of homologous oligonucleotides
140
ranging in size from 11 to 30 nucleotides with 100 mM TEAA and compared the signal enhancing
141
performance of different organic vapors (Figure S5). Isopropanol and ethanol vapors could enhance the
142
MS signal intensity of oligonucleotides regardless of their length while methanol and ACN vapors
143
exhibited lower efficiency in improving the signal intensity of large oligonucleotides (> 15mer
144
nucleotides).
145
Organic solvent concentration in the electrospray solution seemed to have a significant impact on
146
ionization efficiency in open ambient electrospray and the signal intensity of oligonucleotide exhibited
147
20-folds improvement during the ACN was increased from 5 to 45% (Figure 4a). The increase of signal
148
intensity at higher concentrations of organic modifier could be attributed to the lower surface tension
149
and faster evaporation of solvent from the electrospray droplets16. However, we observed organic
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
150
solvent concentration has little influence on oligonucleotides signal intensity in concentrated
151
isopropanol vapor assisted electrospray (Figure 4b), which might be helpful in improving the
152
reproducibility of oligonucleotides intensity in quantitative analyses by gradient IP-RPLC-MS. In
153
general, all of the oligonucleotides samples could be eluted by a mobile phase containing 20% ACN in
154
IP-RPLC separation. Comparing with the MS signal intensity of oligonucleotide in 20% ACN
155
electrospray solution (with 100 mM TEAA), isopropanol vapor assisted electrospray could improve the
156
signal intensity about 600 folds (Figure 4), which further demonstrated the concentrated isopropanol
157
vapor could significantly alleviate the signal suppression caused by TEAA.
158
Then, electrospray solution pH was adjusted from 9.2 to 6.1 through adding appropriate acetic
159
acid. The pH of the electrospray solution also exhibited little influence on the signal intensity of
160
oligonucleotide under the isopropanol vapor assisted electrospray (Figure S6). We investigated the
161
influence of different organic vapor on ESI-MS detection with different ion-pair reagents in
162
electrospray solution (Figure S7). Briefly, alcohols atmospheres could greatly improve the signal
163
intensity in all of the three ion-pair reagents while the effect of ACN was negligible. Note that
164
methanol vapor introduced a special signal enhancing effect for TEAB containing sample solution
165
comparing to TEAA and TEAF while isopropanol and ethanol exhibited similar and relative high
166
efficiency in alleviating the ion suppression effects of all three ion-pair reagents. The plot of signal
167
intensity vs injected oligonucleotide concentration (within 100 mM TEAA) showed good linearity
168
(R2=0.999) over more than 2 orders of magnitudes (0.1 µM - 10 µM) in isopropanol vapor assisted
169
ESI-MS detection (Figure S8 and S9). For traditional ESI-MS without organic vapor, the signal
170
intensity of oligonucleotide in 100 mM TEAA solution was much lower and only two visible data
171
points were detected in the same concentration range with detection limit at near 5 µΜ (Figure S9).
172 173
IP-RPLC-MS for oligonucleotides analysis.
174
When coupling IP-RPLC with negative mode ESI-MS for analyzing complex oligonucleotides samples,
175
traditional strategies usually reduce the concentration of TEAA to make a balance between optimum
176
LC separation resolution and MS detection sensitivity2,7,12,24,25. As we have demonstrated that
177
concentrated alcohol vapor could significantly alleviate the signal suppression effect caused by TEAA,
178
IP-RPLC eluted mobile phase containing 100 mM TEAA could be directly injected into ESI-MS
179
without any other purification or dilution procedures. Here, the mixture of 7 oligonucleotides with
ACS Paragon Plus Environment
Page 6 of 19
Page 7 of 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
180
similar lengths and different sequences was analyzed by IP-RPLC-MS with mobile phase containing
181
100 mM TEAA (Figure 5). All of the oligonucleotides were well separated and high MS signal
182
intensity was feasibly achieved. Adduction with alkali metal ions is always the major problem in
183
negative ESI-MS detection of oligonucleotides due to the existence of phosphodiester groups26.
184
However, few adduction peaks were present in the MS signals obtained by concentrated isopropanol
185
vapor assisted ESI-MS. Further, oligonucleotides with different lengths ranging from 11 to 25
186
nucleotides could be effectively separated and high MS signal intensity was also obtained (Figure S10).
187
We also compared the MS results in ambient electrospray condition and couldn’t find any stable MS
188
signals of targeted oligonucleotides as previous reported11.
189 190
Improving detection sensitivity of positive mode MS for oligonucleotides
191
Oligonucleotides tend to form negative ions in ESI-MS detection due to its backbone phosphodiester
192
groups (pKa < 1), and most of the oligonucleotides analyses including molecular weights determination
193
and structural elucidation were performed in negative mode MS27-32. Meanwhile, a handful of ESI-MS
194
studies were carried out on positively charged oligonucleotides33-37, while most authors conceded that
195
negative mode MS was more suitable for oligonucleotides detection with higher sensitivity. Despite the
196
generally accepted benefits of negative mode MS for oligonucleotide detection, being able to detect
197
oligonucleotides in positive mode MS may have some practical advantages. For example, other
198
biomolecules such as proteins and peptides are usually ionized and characterized in positive mode MS
199
with higher efficiency38,39, which makes simultaneous detection of oligonucleotides, peptides and
200
proteins in only one MS experiment impossible. However, the regulations of gene activation or
201
inhibition are usually related with functional proteins, such as histones40,41.
202
At first, we tried to detect oligonucleotides in positive mode MS by adding different kinds and
203
concentration (0.1% or 1%) of organic acids in the electrospray solution (Figure S11). Obviously, the
204
MS signal of oligonucleotides obtained in this way always carried with a lot of metal adducts, which
205
interfered the accurate characterization of targeted oligonucleotide and caused signal attenuation. Then
206
we tried to improve the oligonucleotides signals in positive mode MS by doping different organic acid
207
vapor into the enclosed electrospray chamber. It was observed that the peak adducts were almost
208
disappeared and the corresponding MS signal intensity of oligonucleotides was highly enhanced
209
compared to direct changing the electrospray solution pH42. Generally, the propanoic acid vapor
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
210
(consumption rate, 21.8 µL(liquid)/min) gave the highest MS signal enhancement efficiency among all
211
investigated organic acid vapors and the enhancement ratio was more than 10 folds for oligonucleotide
212
N-9 (15mer) (Figure S11). Then we compared the MS detection results of a mixed oligonucleotide
213
sample containing 14 different oligonucleotides ranging from 11mer to 29mer with identical
214
concentration in both positive and negative modes MS (Figure S12). Interestingly, the signal intensity
215
exhibits no dependence on the length of oligonucleotides and similar peak intensity was obtained for
216
these oligonucleotides in positive mode MS. While oligonucleotides signal within pure water solution
217
in negative mode MS was not so stable and we used a common buffer (400 mM HFIP, 16.3 mM TEA,
218
pH 8.5) to stabilize and improve the signals. Even so, the oligonucleotides signal intensity in positive
219
mode MS by using propanoic acid vapor assisted electrospray strategy was higher than that in negative
220
mode MS (Figure S12). Furthermore, the plot of signal intensity (sum of the peak intensity of all
221
individual charge states) vs injected concentration exhibited good linearity (R2=0.999) over more than
222
2 orders of magnitudes (0.05 µM - 5 µM dT15) in the propanoic acid assisted ESI-MS (Figure S13).
223
The detection limit was near 0.01 µΜ (Figure S14b) with propanoic acid vapor-assistance, which was
224
much better than the detection limit at about 0.5 µΜ in the traditional ambient ESI-MS detection
225
without organic acid vapor (Figure S14c).
226
The MS/MS characterizations of the oligonucleotides N-1 (Figure 6), N-3 (Figure S15a) and N-4
227
(Figure S15b) were performed in both negative and positive mode MS, respectively. Although similar
228
types of fragment ions were obtained, the MS/MS fragment ions exhibited good complementary
229
between positive and negative modes. For example, some fragment ions of oligonucleotide N-1, such
230
as a9-B (1312.73, z=2), was more abundant in positive mode MS while others like a3-B (705.13, z=1)
231
and a5-B (1338.24, z=1) were easier to be observed in negative MS signals. The fragment ions could be
232
easily recognized because of the same fragment ion had a fixed mass difference as 2 Da between
233
negative and positive modes. Thus sequencing an unknown oligonucleotide could be simplified if we
234
excluded the interfering fragment ions by comparing the MS/MS spectra between negative and positive
235
modes MS.
236
Furthermore, simultaneous detection of oligonucleotides with peptides or proteins could be
237
realized in the present study. Firstly, 14 oligonucleotides (Table S3) were mixed together with tryptic
238
digest of BSA at the ratio 100/1 (w/w). Both oligonucleotides and peptides were well detected in
239
propanoic acid vapor assistant ESI-MS analysis. Then we increased the addictive amount of peptides
ACS Paragon Plus Environment
Page 8 of 19
Page 9 of 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
240
10 times, and the signal intensity of 14 oligonucleotides ranging from 11mer to 29mer exhibited little
241
change (Figure S16). Control experiments were also performed with open ambient ESI-MS in negative
242
mode MS (Figure S17, Table S4). Although the simultaneously detection of oligonucleotides and
243
peptides could be obtained in alkali solution (400 mM HFIP, 16.3 mM TEA, pH 8.5), the signal
244
intensity of peptides decreased seriously with -1 charge state. On the other hand, the signal intensity of
245
BSA tryptic peptides was improved 2-3 times after introducing propanoic acid vapor into the enclosed
246
ESI source (Figure S18), which was consisted to previous work by Li et al43. The peptides charge states
247
were increased after the acidic vapor introduction (Figure S18a and S18b). For example, the major
248
charge state of the peptide KVPQVSTPTLVEVSR moved from +2 (m/z 820) to +3 (m/z 547).
249
Furthermore, the MS signals of BSA tryptic peptides was nearly not influenced after mixed together
250
with oligonucleotides and simultaneously detected under acid vapor assisted ESI-MS (Figure S18b and
251
S18d). As histones contribute to dynamic maintenance and regulation of chromatin structure, to gene
252
activation, DNA repair and many other processes in cell nucleus, it makes sense if we could
253
simultaneously detect histone proteins along with complex oligonucleotides25,44. Thus, the 14
254
oligonucleotides were mixed together with histones at the ratio 1/4, 1/40 (w/w) and analyzed by
255
propanoic acid vapor assisted ESI-MS (Figure 7 and S19). Briefly, the composition of histone proteins
256
were successfully attributed to H2A, H2B, H4 and their accompanying post-translational modifications
257
such as acetylation (42 Da, Figure S20)45,46, and the 14 targeted oligonucleotides were also feasible
258
detected and the signal intensity was comparable to the experiments without mixing histones. Therefore,
259
simultaneously detect oligonucleotides and peptides or proteins in positive mode MS were realized in
260
our study and the signals have little interferences to each other.
261
In the present study, the MS ion suppression effect of high concentration TEAA was significantly
262
alleviated by highly concentrated alcohol vapor assisted electrospray (Figure S21). Actually, there are
263
two main reasons for the MS signal suppression effect of TEAA on oligonucleotides detection6. Firstly,
264
TEA has a lower boiling point than acetic acid (89℃ vs. 118℃) and evaporates more quickly than
265
acetic acid during the ionization process. The enrichment of acetic acid decreases the pH in the
266
electrospray droplet, which then induces the ionization competition between the acetic acid and
267
oligonucleotides and decreases the ionization efficiency of the latter one. On the other hand, TEAA is
268
also less hydrophobic than other ion-pair reagents such as HFIP-TEA. Thus, the surface tension of the
269
droplets is higher and would decrease the ionization efficiency of oligonucleotides43,47. The exposure of
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
270
TEAA containing charged droplets to concentrated alcohol (ethanol and isopropanol) vapors could
271
improve the ion evaporation rates of both TEA and acetic ions through reducing their activation energy
272
for ion evaporation compared to the ambient condition48,49. In our experiments, the MS signals of both
273
TEA and acetic acid from 100 mM TEAA solution exhibited significant improvement after introducing
274
concentrated alcohol vapors (Figure S22 and S23). We also observed the MS signal suppression effect
275
of 100 mM acetic acid solution could be effectively alleviated with isopropanol vapor assisted
276
electrospray (Figure S24). Furthermore, the alcohols could engage in extensive hydrogen bonding on
277
the droplet surface and thereby reduce the surface tension through lowering the solvation energy48.
278
On the other hand, the MS signals of oligonucleotides were significantly enhanced and the metal
279
adducts signals were greatly reduced (Figure S11 and S14e) in the positive mode MS detection by
280
acidic vapor (mainly propanoic acid) assisted electrospray. Unlike other biomolecules, such as protein
281
and peptide, oligonucleotide tends to form negative ions in ESI-MS detection due to its backbone
282
phosphodiester groups (pKa < 1). The nucleobases exposed in highly concentrated propanoic acid
283
atmosphere could get more chance to combine with dissociated protons and the concentrated acidic
284
vapor could also prevent the dissociation of protons from backbone phosphodiester groups37,50,51.
285
Therefore, the effect of acidic vapor observed in positive mode MS was more likely to be
286
improvements in both MS signal intensity and signal-to-noise through improving the oligonucleotide
287
ionization efficiency and reducing the metal counter adducts48.
288 289
CONCLUTION
290
In this study, the signal suppression effect of high concentration (100 mM) TEAA was significantly
291
alleviated by alcohol vapor (isopropanol or ethanol) assisted electrospray ionization strategy. Then,
292
effective IP-RPLC separation (with 100 mM TEAA) was feasibly coupled with high-sensitive MS
293
detection (negative mode) for oligonucleotides. The signal enhancement ratio was about 600 folds (for
294
sample dT15) in the mobile phase containing 100 mM TEAA and 20% ACN. Furthermore,
295
oligonucleotides detection in positive mode MS was realized with little adducts by using organic acid
296
(propanoic acid) vapor assisted electrospray and the average signal intensity enhancement ratio was
297
more than 10 folds compared to direct adding acids into the electrospray solution. As oligonucleotides
298
could be detected in positive mode with high performance, simultaneous detection of oligonucleotides
299
with complex peptides or histone proteins were feasibly realized with little influence to each other.
ACS Paragon Plus Environment
Page 10 of 19
Page 11 of 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
300
Overall, we provideed a promising alternative for high-sensitive characterization of oligonucleotides by
301
MS, which might play important roles in elucidating the oligonucleotides biological functions in the
302
future.
303 304
FUNDING
305
This work was supported by the China State Key Research Grant [2016YFF0200504], the China State
306
Key Basic Research Program Grant [2013CB911203], the National Natural Science Foundation of
307
China [21675152 and 21235005], the Youth Innovation Promotion Association CAS [2014164] and
308
grant from DICP (ZZBS201603).
309 310
REFERENCES
311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338
(1) Wang, Y.; Navin, N. E. Mol. Cell 2015, 58, 598-609. (2) Taoka, M.; Nobe, Y.; Hori, M.; Takeuchi, A.; Masaki, S.; Yamauchi, Y.; Nakayama, H.; Takahashi, N.; Isobe, T. Nucleic Acids Res. 2015, 43, e115-e115. (3) Björkbom, A.; Lelyveld, V. S.; Zhang, S.; Zhang, W.; Tam, C. P.; Blain, J. C.; Szostak, J. W. J. Am. Chem. Soc. 2015, 137, 14430-14438. (4) Deleavey, G. F.; Damha, M. J. Chem. Biol. 2012, 19, 937-954. (5) Fritz, H. J.; Belagaje, R.; Brown, E. L.; Fritz, R. H.; Jones, R. A.; Lees, R. G.; Khorana, H. Biochemistry 1978, 17, 1257-1267. (6) McGinnis, A. C.; Chen, B.; Bartlett, M. G. J. Chromatogr. B 2012, 883, 76-94. (7) Yamauchi, Y.; Nobe, Y.; Izumikawa, K.; Higo, D.; Yamagishi, Y.; Takahashi, N.; Nakayama, H.; Isobe, T.; Taoka, M. Nucleic Acids Res. 2016, 44, e59-e59. (8) Oberacher, H.; Oefner, P. J.; Parson, W.; Huber, C. G. Angew. Chem. Int. Ed. 2001, 40, 3828-3830. (9) Dickman, M. J. J. Chromatogr. A 2005, 1076, 83-89. (10) Dickman, M. J.; Hornby, D. P. Rna 2006, 12, 691-696. (11) Apffel, A.; Chakel, J. A.; Fischer, S.; Lichtenwalter, K.; Hancock, W. S. Anal. Chem. 1997, 69, 1320-1325. (12) Gong, L. Rapid Commun. Mass Spectrom. 2015, 29, 2402-2410. (13) Liu, C.; Wu, Q.; Harms, A. C.; Smith, R. D. Anal. Chem. 1996, 68, 3295-3299. (14) Huber, C. G.; Krajete, A. Anal. Chem. 1999, 71, 3730-3739. (15) Huber, C. G.; Krajete, A. J. Chromatogr. A 2000, 870, 413-424. (16) Deguchi, K.; Ishikawa, M.; Yokokura, T.; Ogata, I.; Ito, S.; Mimura, T.; Ostrander, C. Rapid Commun. Mass Spectrom. 2002, 16, 2133-2141. (17) Zhang, H.; Ou, J.; Liu, Z.; Wang, H.; Wei, Y.; Zou, H. Anal. Chem. 2015, 87, 8789-8797. (18) Fountain, K. J.; Gilar, M.; Gebler, J. C. Rapid Commun. Mass Spectrom. 2003, 17, 646-653. (19) Wang, F.; Dong, J.; Jiang, X.; Ye, M.; Zou, H. Anal. Chem. 2007, 79, 6599-6606. (20) Wang, F.; Chen, R.; Zhu, J.; Sun, D.; Song, C.; Wu, Y.; Ye, M.; Wang, L.; Zou, H. Anal. Chem. 2010, 82, 3007-3015. (21) Zhu, Y.; Lu, T. 2013, US Pat., 0009055A1.
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377
(22) Chen, J.; Liu, Z.; Wang, F.; Mao, J.; Zhou, Y.; Liu, J.; Zou, H.; Zhang, Y. Chem. Commun. 2015, 51, 14758-14760. (23) Chen, J.; Wang, F.; Liu, Z.; Liu, J.; Zhu, Y.; Zhang, Y.; Zou, H. J. Chromatogr. A 2017, 1483, 101-109. (24) Bleicher, K.; Bayer, E. Chromatographia 1994, 39, 405-408. (25) Taoka, M.; Yamauchi, Y.; Nobe, Y.; Masaki, S.; Nakayama, H.; Ishikawa, H.; Takahashi, N.; Isobe, T. Nucleic Acids Res. 2009, 37, e140-e140. (26) Huber, C. G.; Buchmeiser, M. R. Anal. Chem. 1998, 70, 5288-5295. (27) McLuckey, S. A.; Habibi-Goudarzi, S. J. Am. Chem. Soc. 1993, 115, 12085-12095. (28) Brodbelt, J. S. Chem. Soc. Rev. 2014, 43, 2757-2783. (29) Gao, Y.; Yang, J.; Cancilla, M. T.; Meng, F.; McLuckey, S. A. Anal. Chem. 2013, 85, 4713-4720. (30) Harper, B.; Neumann, E. K.; Solouki, T. J. Am. Soc. Mass Spectrom. 2015, 26, 1404-1413. (31) Taucher, M.; Breuker, K. Angew. Chem. Int. Ed. 2012, 124, 11451-11454. (32) Potier, N.; Van Dorsselaer, A.; Cordier, Y.; Roch, O.; Bischoff, R. Nucleic Acids Res. 1994, 22, 3895-3903. (33) Sannes-Lowery, K. A.; Mack, D. P.; Hu, P.; Mei, H.-Y.; Loo, J. A. J. Am. Soc. Mass Spectrom. 1997, 8, 90-95. (34) Barylyuk, K.; Gülbakan, B.; Xie, X.; Zenobi, R. Anal. Chem. 2013, 85, 11902-11912. (35) Xu, N.; Chingin, K.; Chen, H. J. Mass Spectrom. 2014, 49, 103-107. (36) Rodríguez, M. C.; Fernández, L. L.; Fernández, A. G.; Rendueles, A. S.; Pedregal, E. M.; Bettmer, J.; Blanco-González, E.; Montes-Bayón, M.; Gamasa, M. P.; Lastra, E. J. Anal. At. Spectrom. 2015, 30, 172-179. (37) Kharlamova, A.; Prentice, B. M.; Huang, T.-y.; McLuckey, S. A. Int. J. Mass Spectrom. 2011, 300, 158-166. (38) Bowie, J. H.; Brinkworth, C. S.; Dua, S. Mass Spectrom. Rev. 2002, 21, 87-107. (39) Loo, J. A.; Loo, R. R. O.; Light, K. J.; Edmonds, C. G.; Smith, R. D. Anal. Chem. 1992, 64, 81-88. (40) Garcia, B. A.; Shabanowitz, J.; Hunt, D. F. Curr. Opin. Chem. Biol. 2007, 11, 66-73. (41) Sidoli, S.; Cheng, L.; Jensen, O. N. J. Proteomics 2012, 75, 3419-3433. (42) Kulyk, D. S.; Miller, C. F.; Badu-Tawiah, A. K. Anal. Chem. 2015, 87, 10988-10994. (43) Li, Z.; Li, L. Anal. Chem. 2013, 86, 331-335. (44) Trahan, C.; Oeffinger, M. Nucleic Acids Res. 2016, 44, 1354-1369. (45) Görisch, S. M.; Wachsmuth, M.; Tóth, K. F.; Lichter, P.; Rippe, K. J. Cell Sci.2005, 118, 5825-5834. (46) Miller, C. F.; Kulyk, D. S.; Kim, J. W.; Badu-Tawiah, A. K. Analyst 2017, 142, 2152-2160. (47) Bruins, A. P. J. Chromatogr. A 1998, 794, 345-357. (48) DeMuth, J. C.; McLuckey, S. A. Anal. Chem. 2014, 87, 1210-1218. (49) Nguyen, S.; Fenn, J. B. Proc. Natl. Acad. Sci. U. S. A. 2007, 104, 1111-1117. (50) Green-Church, K. B.; Limbach, P. A. J. Am. Soc. Mass Spectrom. 2000, 11, 24-32. (51) Turner, K. B.; Monti, S. A.; Fabris, D. J. Am. Soc. Mass Spectrom. 2008, 130, 13353-13363.
378 379 380 381
ACS Paragon Plus Environment
Page 12 of 19
Page 13 of 19
382
Open state Ambient ESI source
6
2
1
Enclosed state
a
7
CEESI source 3
b 5
4
383 384
Figure 1. Instrumental configuration illustration of the (a) ambient ESI source and (b) enclosed CEESI
385
source (Haochuang, China). 1, high voltage; 2, C18 capillary separation column; 3, air flow; 4, organic
386
solvent; 5, rubber ring; 6, heated ion transfer capillary; 7, MS high vacuum.
387 388 107
Isopropanol Ambient 106
Intensity
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
a
105
b
104
0
389
20
40
60
80
100
TEAA (mM)
390
Figure 2. Influence of different TEAA concentration on the dT15 signal intensity in isopropanol vapor
391
assisted (a) or open ambient (b) ESI-MS detection, respectively. Conditions: TEAA concentration,
392
varying from 10 to 100 mM; 45% ACN; sample, 10 µM dT15; negative mode MS detection; sample
ACS Paragon Plus Environment
Analytical Chemistry
393
injection rate, 3 µL/min.
394 395 100
a Am bie nt
Ac eto nit ril e Am bie nt Iso pr op an ol
Am bie nt
20
Et ha no l
40
Iso pr op an ol Am bie nt
60
Me tha no l Am bie nt
80
Am bie nt
Relative Abundance
0 100 80
b
0 0.0
396
0.5
1.0
1.5
2.0
2.5
3.0 3.5 Time (min)
4.0
4.5
5.0
Am bie nt
20
Iso
40
pr op an ol Am bie nt Iso pr op an ol Am bie nt Iso pr op an ol Am bie nt Iso pr op an ol Am bie nt Iso pr op an ol
60
Am bie nt
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 14 of 19
5.5
6.0
397
Figure 3. (a) Influences of different alcohol vapor (isopropanol, ethanol, methanol and acetonitrile) on
398
the MS signal intensity of dT11. (b) The reproducibility of dT11 MS signals in isopropanol vapor
399
assisted electrospray. Conditions: TEAA concentration, 100 mM; 5% ACN; sample, 10 µM dT11;
400
negative mode MS detection; sample injection rate, 3 µL/min.
401 402 403 404 405 406
ACS Paragon Plus Environment
Page 15 of 19
Ambient Isopropanol
106 2.63E+05
3.42E+05
2.85E+05
2.62E+05
3.66E+05 3.42E+05
a
105
Intensity
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
600-fold
104
9.57E+03 6.28E+03 4.38E+03
b 1.16E+03
103
569
489
102 0
407
10
20
30
40
50
ACN%
408
Figure 4. Influence of acetonitrile in electrospray solution on the dT15 signal intensity in isopropanol
409
vapor assisted (a) or open ambient (b) ESI-MS detection, respectively. Conditions: TEAA
410
concentration, 100 mM; ACN percentage, varying from 5 to 45%; sample, 10 µM dT15; negative mode
411
MS detection; sample injection rate, 3 µL/min.
412 413 414 415 416 417
ACS Paragon Plus Environment
Analytical Chemistry
100
N-1
95
100
N-5 NL: 1.61E6 CCGCTCGAGGC
90 85
[M-3H]
N-6 [M-3H]
N-4 NL: 1.70E6 ATGCCTCAAGG
55 50 45
N-3 NL: 2.03E6 ATGGCGAGCTAT
40 35
dT11 NL: 1.81E6 TTTTTTTTTTT
30 25 20
dT12 NL: 1.68E6 TTTTTTTTTTTT
15 10
dT11
N-5
2-
[M-3H]
3-
[M-3H]
3-
[M-2H]
2-
50 Relative Abundance
60
[M-2H]
N-4
dT12
0 100
N-1 NL: 2.34E6 TTGTGAAGCTT
3-
50
70 65
N-3
2-
50
N-6 NL: 1.70E6 CCGCTCGAGGCA
75
3-
[M-2H] 0 100
80
Relative Abundance
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 16 of 19
0 100
[M-2H]
2-
50 0 100
[M-3H]
3-
[M-2H]
2-
50 0 100
[M-3H]
3-
[M-2H]
2-
50 0 100
[M-3H]
3-
[M-2H]
50
2-
0 1000
1200
1400
1600
1800
2000
m/z
5 0 6
8
10
12
14
16 Time (min)
18
20
22
24
26
418 419
Figure 5. IP-RPLC-MS analysis of oligonucleotides with 100 mM TEAA as ion-pair reagent and
420
isopropanol assisted electrospray. Conditions: Column, AQ-C18, 5 µm, 20 cm × 75 µm i.d.; mobile
421
phase, 100 mM TEAA, pH 7.0, 5% acetonitrile (buffer A), 100mM TEAA, pH 7.0, 45% acetonitrile
422
(buffer B); linear gradient, 0% buffer B for 5 min, from 0 to 30% for 25 min; flow rate, 200 nL/min;
423
electrospray voltage, 2.0 kV; negative mode MS detection; sample, N-1, N-3, N-4, N-5, N-6, dT11 and
424
dT12, 2 pmol for each.
425 426
ACS Paragon Plus Environment
Page 17 of 19
w3 100 Relative Abundance
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
a3-B705.13 z=1
80 60
w2 -
40
625.10 z=1
20 0 100
401.02 z=?
a5-B1338.24 z=1
w62-
721.10 z=2 833.14 z=2
1313.23 z=2
a9-B2+
w2 +
60 609.10 z=1 483.06 z=1
305.05 z=1
w5 -
1436.23 1556.27 z=1 z=1
w8 a9-B2-
490.06 z=1
627.11 z=1
40
w fragment a-B fragment
934.16 w4 z=2 1243.21 989.67 z=1 z=2 2a8-B2a7-B 1146.20 z=2 2-
Positive mode
80
20
914.15 z=1
Negative mode
z=1
400
600
1869.34 z=1
.53 48 43 .38 .33 .27 .21 6 1 7 37 3. 4. 00 71 58 45 6.1 .1 .0 31 283 250 22 18 15 12 91 627 323
4 9 5 1 6 7 9 4 9 3.0 7.1 6.1 0.2 .2 .3 .4 .4 .4 40 70 103 134 16691982 229526242913
a3-B+ 1084.53 1237.71 z=3 w3 + a5-B+ 707.14 z=2 z=1 1340.24 916.16 2+ 785.39 z=1 2+ w6 2+ a8-B w82+ z=1 z=4 a -B 2+ w5
7
1586.27 z=2
a6-B+1760.28 z=1
0
427
w6-
a6-B- 1765.29
800
1000
1200
1400
1600
1800
a7-B+ 1982.34 z=1 2000
m/z
428
Figure 6. The MS/MS spectra of N-1 (11mer) in negative and positive modes ESI-MS detection,
429
respectively. Collision induced dissociation was applied in both cases.
430 431 432 433 434
ACS Paragon Plus Environment
Analytical Chemistry
Oligonucleotides
Histones
H2A
1133.21 z=4
N-7
100
984.69 N-5 z=4
90
N-4 80
908.68 z=4
701.16 z=20
60 50
N-1
N-6
70
N-3 1229.23 N-6z=3
N-8
778.90 z=18 637.46 z=22
N-12
Relative Abundance
N-9
Relative Abundance
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 18 of 19
100
H2B
80
689.74 z=20
701.16 z=20
698.45 z=19
60 40
20 1463.67 N-7 z=5 0 1312.58 690 z=3 N-10 N-13 1529.48 z=5 N-2 1613.54 z=4
H4
703.26 z=20
694.69 z=20
710.23 z=16
700
710
720
m/z
N-8 1413.93 z=3
N-3
N-9 N-12
40
1829.33 z=4
30
N-14
1778.32 z=5
20
1681.82 z=2
10
N-13 1911.59 z=4
0 600
800
1000
1200
1400
1600
1800
2000
m/z
435 436
Figure 7. The full MS spectrum of the mixture of oligonucleotides and histones in propanoic acid
437
vapor assisted positive ESI-MS detection. Conditions: electrospray solution, H2O; sample, 50 µg/mL
438
oligonucleotides (N-1 to N-14) and 200 µg/mL histone proteins; positive mode MS detection; sample
439
injection rate, 3 µL/min.
440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459
ACS Paragon Plus Environment
Page 19 of 19
460 461 462
TOC graphic Open state
a
Ambient ESI source
C18 capillary analysis column Enclosed state
high voltage
heated ion transfer tube high vacuum CEESI source
air
b rubber ring organic solvent
b
100
b
80
b
b
1.63
0.59
2.62
1.71
b
4.59
3.55
2.68
0.55
90
Relative Abundance
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
4.65
3.58
2.72
4.71
3.71 4.56
1.57
70 60 50 40
a
a
a
a
a
a
30 20 10 0 0.0
463 464 465
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Ti me (min)
ACS Paragon Plus Environment