Field Calibration of XAD-Based Passive Air Sampler on the Tibetan

Apr 25, 2017 - CAS Center for Excellence in Tibetan Plateau Earth Sciences, Beijing ... of the XAD-PAS were calibrated at three sites on the Tibetan P...
0 downloads 0 Views 2MB Size
Subscriber access provided by UB + Fachbibliothek Chemie | (FU-Bibliothekssystem)

Article

Field calibration of XAD-based passive air sampler on the Tibetan Plateau: wind influence and configuration improvement Ping Gong, Xiao-ping Wang, Xiande Liu, and Frank Wania Environ. Sci. Technol., Just Accepted Manuscript • Publication Date (Web): 25 Apr 2017 Downloaded from http://pubs.acs.org on April 28, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 28

Environmental Science & Technology

1

Field calibration of XAD-based passive air sampler on the

2

Tibetan Plateau: wind influence and configuration

3

improvement

4

Ping Gong1,2, Xiaoping Wang1,2*, Xiande Liu3, and Frank Wania4

5 6 7

1

8

Institute of Tibetan Plateau Research, Chinese Academy of Sciences (CAS), Beijing

9

100101, China

10

2

Key Laboratory of Tibetan Environmental Changes and Land Surface Process,

CAS Center for Excellence in Tibetan Plateau Earth Sciences, Beijing 100101, China

11 12

3

Chinese Research Academy of Environmental Sciences, Beijing 100012, China

13

4

University of Toronto Scarborough, Department of Physical and Environmental

14

Sciences, 1265 Military Trail, Toronto, ON, Canada, M1C 1A4

15 16 17

* Corresponding Author

18

Tel: +86-10-84097120

19

Fax: +86-10-84097079

20

E-mail: [email protected]

21 22 23

Word account: text (5000) + 5 figures (5*300=1500) = 6500 1

ACS Paragon Plus Environment

Environmental Science & Technology

24

Abstract

25

The passive air sampler based on XAD-2 resin (XAD-PAS) has proven useful for

26

collecting atmospheric persistent organic pollutants (POPs) in remote regions.

27

Whereas laboratory studies have shown that, due to the open bottom of its housing,

28

the passive sampling rate (PSR) of the XAD-PAS is susceptible to wind and other

29

processes causing air turbulence, the sampler has not been calibrated in the field at

30

sites experiencing high winds. In this study, the PSRs of the XAD-PAS were

31

calibrated at three sites on the Tibetan Plateau, covering a wide range in temperature

32

(T), pressure (P) and wind speed (v). At sites with low wind speeds (i.e. in a forest

33

and an urban site), the PSRs are proportional to the ratio  . ⁄ ; at windy sites with

34

an average wind speed above 3 m/s, the influence of v on PSRs cannot be ignored.

35

Moreover, the open bottom of the XAD-PAS housing causes the PSRs to be

36

influenced by wind angle and air turbulence caused by sloped terrain. Field

37

calibration, wind speed measurements, and computational fluid dynamics (CFD)

38

simulations indicate that a modified design incorporating an air spoiler consisting of 4

39

metal sheets dampens the turbulence caused by wind angle and sloped terrain and

40

caps the PSR at ~5 m3/day, irrespective of ambient wind. Therefore, the original

41

XAD-PAS with an open bottom is suitable for deployment in urban areas and other

42

less windy places, the modified design is preferable in mountain regions and other

43

places where air circulation is complicated and strong.

2

ACS Paragon Plus Environment

Page 2 of 28

Page 3 of 28

Environmental Science & Technology

44

Introduction

45

Due to their simplicity, low cost and power-free operation, passive air samplers (PASs)

46

have been widely used over the past decades.1-3 They have proven suitable to

47

complement conventional high-volume active air sampling (AAS) activities when

48

evaluating the global distribution and long-range transport of persistent organic

49

pollutants (POPs).1 The challenge to a wider adoption of PASs is the need to obtain

50

accurate passive sampling rates (PSRs, m3/day) which are required to convert time-

51

integrated amounts of POPs (ng/sampler) into volumetric air concentrations (pg/m3).2

52

Given that the Stockholm Convention requires every Conference of the Parties to

53

provide comparable monitoring data on the presence of POPs,4 reducing the

54

uncertainty of PSRs is essential.3

55

Various meteorological conditions, such as temperature, atmospheric pressure, wind

56

speed and angle can cause a variation in the rate of POP uptake in a PAS sorption

57

medium.3,

58

sequestrated by PAS deployed at different sites into volumetric concentrations can be

59

expected to introduce considerable uncertainty. Depuration compounds (DCs) are

60

commonly added to polyurethane foam (PUF)-disk PAS (PUF-PAS) to obtain PSRs

61

that are specific to a location and a deployment period.8-10 The uptake of the sampled

62

chemicals is then inferred from the loss kinetics of the DCs.8-10 Although a non-

63

negligible kinetic resistance of POPs within the sorption medium (PUF) violates a key

64

assumption of this approach,11 it is generally accepted as a practical, albeit expensive

65

way to account for differences in PSRs between sites and deployment periods.

66

Another commonly used sorption medium in PAS is the polystyrene-divinylbenzene

67

resin XAD-2.12An indoor calibration13 found the PSR of a XAD-PAS exposed to

68

laboratory-generated windy conditions to be approximately 3-4 times higher than

69

under wind-still conditions.13 Field deployments of XAD-PAS in high mountains

70

occasionally also reported higher PSRs, which were mainly attributed to high winds.14,

71

15

5-7

Thus, using a single, uniform PSR to convert chemical amounts

In fact, a distinct feature of alpine regions is a wide diversity of climate and surface 3

ACS Paragon Plus Environment

Environmental Science & Technology

72

cover. For example, there could be tropical, temperate and frigid zones along an

73

altitudinal slope, resulting in surface coverage as diverse as forests, meadows and

74

glaciers.16, 17 Although PAS have already been used to investigate transport and fate

75

of POPs in the European Alps,18,

76

Himalayas,16comparing PAS data between and within mountainous areas certainly

77

demands careful attention to the influence of climate (temperature; T), elevation

78

(atmospheric pressure; P) and complicated wind circulation patterns (planetary wind,

79

diurnal valley wind and glacier wind; v) on PSRs. Thus, there is a clear need for a

80

systematic field calibration of PASs in a mountain environment.

81

The high absorptive capacity of XAD for POPs allows XAD-PAS to be deployed for

82

long sampling durations (6~12 months).12, 14, 22 During such long times of deployment,

83

according to our experience, the housings of PAS can sometimes become slanted by

84

strong winds, causing wind to blow directly into the open bottom of the housing;

85

greatly increased wind speeds in the interior of the sampler housing then cause

86

elevated PSRs.13, 23Valley winds blowing along mountain slopes may change wind

87

angles when they encounter sloped terrain, which may also influence PSRs.14Finally,

88

air turbulence in mountain regions frequently arises from inhomogeneous solar

89

radiation, which may also exert an effect on PSRs.15 Therefore, modifications to the

90

design of the XAD-PAS that can reduce these complex wind effects would be

91

valuable.

92

In this study, we simultaneously deployed XAD-PAS and AAS at three sites on the

93

Tibetan Plateau (TP), the world's largest mountain region. By sampling in a

94

mountainous forest, a high altitude city and a high alpine terrain we aimed to test

95

whether and how meteorological variations influence the PSRs of the XAD-PAS.

96

Specifically, our objectives were to derive empirical relationships for estimating site-

97

specific PSRs and to explore the ability of a modified sampler design to minimize the

98

influence of wind.

99

Materials and Methods

19

western Rocky Mountains,20 Andes21 and

4

ACS Paragon Plus Environment

Page 4 of 28

Page 5 of 28

Environmental Science & Technology

100

Study regions. The XAD-PAS was calibrated at three sites: Lulang, Lhasa, and Nam

101

Co (Figure 1). Lulang (3300 m), located in southeastern Tibet, is covered by forest

102

and has a humid and relatively warm climate: Average annual temperature is 5.4°C,

103

summer temperatures reach up to 18 °C. Lhasa (3600m), located in a river valley, has

104

an average temperature of 7°C. Wind speed in Lhasa (average of 1.6 m/s) is slightly

105

higher than in Lulang (1 m/s). Given similar elevation, air pressure is similar in

106

Lulang (680 hPa) and Lhasa (650 hPa). Nam Co (4780 m), a truly remote site with

107

limited anthropogenic activities in the central TP, is cold and windy. Average wind

108

speed is 3.3 m/s and instantaneous wind speeds reach up to 9.9 m/s. Due to Nam Co’s

109

high elevation, average temperature (-0.8°C) and air pressure (571 hPa) are low.

110

Field calibration of XAD-PAS under varied meteorological conditions. Duplicate

111

XAD-PAS were deployed at each site for 2-month periods in summer (Period 1),

112

autumn (Period 2), and winter (Period 3). Details for each sampling period are

113

provided in the supporting information (SI, Table S1). By using the natural spatial and

114

seasonal variation in meteorological parameters (T, P, v), the deployments ranged

115

from -11.1 to 16.0°C in T, 565 to 683 hPa in P, and 0.8 to 4.4 m/s in v (Table S2 and

116

Figure 2A), which allows for the derivation of relationships between PSRs and these

117

factors. Prior to deployment, XAD resin was Soxhlet extracted using in turn methanol,

118

acetonitrile, and dichloromethane (DCM). The XAD resin (60 mL of wet XAD in

119

methanol) was transferred to a pre-cleaned stainless steel mesh cylinder and dried in a

120

clean desiccator. Dry cylinders were sealed in airtight stainless steel tubes with Teflon

121

lids. See Wang et al.24 for detailed information about the sampling processes. At all

122

three sites, AAS samples were collected for consecutive 2-week intervals during the

123

entirety of the three sampling periods, with a final volume of ~600 m3. Polyurethane

124

foam (PUF, 7.5 cm × 6 cm diameter) was used to collect gas-phase POPs and

125

particles were collected on glass fiber filters (GFF). Before sampling, the PUF plugs

126

were pre-cleaned by Soxhlet with DCM for 24 h and the GFFs were heated at 450°C

127

for 4 h. All harvested PUFs, GFFs and XAD cylinders were stored at -20 °C until

128

extraction. The PSRs of the XAD-PAS (m3/day) was calculated using: 5

ACS Paragon Plus Environment

Environmental Science & Technology

 =

129



 

(1)

130

Where APAS is the amount of a POP sequestered in the XAD-PAS (pg/sample), t is the

131

sampling period (days), and Cair is the arithmetic mean of the gas phase

132

concentrations of a POP (pg/m3) obtained by AAS during the deployment period of

133

the PAS. Given that the XAD-PAS predominantly samples gas-phase POPs,12 data

134

obtained from the PUF-plugs in the AAS were used for calibration. AAS data for

135

Lulang and Nam Co have been previously published,25, 26 while AAS data of Lhasa

136

are provided in Table S3.

137

Sample Extraction and Analysis. The XAD samples and PUF plugs were spiked

138

with a mixture of surrogate standards (2,4,5,6-tetrachloro-m-xylene, TCmX, and

139

decachlorobiphenyl, PCB 209) and Soxhlet-extracted using DCM for 24 h. The

140

extracts were concentrated and solvent-exchanged to hexane and then purified on a

141

chromatography column (from the top to bottom: 1 g of anhydrous sodium sulfate, 2 g

142

of 3% deactivated alumina, and 3 g of 6% deactivated silica gel). The column was

143

eluted with 30 mL of a mixture of DCM and hexane (1:1). The eluate was further

144

cleaned using gel-permeation chromatography (GPC, containing 6 g of Biobeads

145

SX3), and the samples were finally solvent-exchanged and concentrated in 20 µL of

146

dodecane containing a known quantity of pentachloronitrobenzene (PCNB) and PCB-

147

54 as internal standards. The target compounds in this study are hexachloro-

148

cyclohexanes (HCHs, including α-HCH, β-HCH, and γ-HCH), hexachlorobenzene

149

(HCB), dichlorodiphenyltrichloroethanes (DDTs, including o,p′-DDT and p,p′-DDT)

150

and their degradation products (o,p′-DDE and p,p′-DDE), and selected poly-

151

chlorinated biphenyl congeners (PCBs, including PCB-28, -52, -101, -138, -153, and -

152

180). POPs were analyzed on a gas chromatograph with an ion-trap mass

153

spectrometer (GC-MS, Finnigan Trace GC/PolarisQ) operating in the MS–MS mode.

154

A CP-Sil 8 CB capillary column (50 m, 0.25 mm, 0.25 µm) was chosen and helium

155

was used as the carrier gas at 1.0 mL min-1 under constant-flow mode. The oven

156

temperature began at 100 °C for 2 min and increased to 140 °C at a rate of 20 °C 6

ACS Paragon Plus Environment

Page 6 of 28

Page 7 of 28

Environmental Science & Technology

157

min-1, to 200 °C (10 min hold time) at a rate of 4 °C min-1, 4 °C min-1 to 300 °C, and

158

held for 17 min.

159

Quality Assurance/Quality Control (QA/QC). Eight and five field blanks were

160

collected for XAD columns and PUF plugs, respectively. Laboratory blanks and field

161

blanks were extracted and analyzed in the same way as the samples. None of the

162

chemicals was detected in laboratory blanks, but trace amounts of POPs were detected

163

in field blanks (SI Table S4 and S5). The limits of detection (LOD, SI Table S4 and

164

S5) were derived as the mean blank concentration plus 3 times its standard deviation;

165

when a target compound was not detected in the blanks, the concentration of the

166

lowest calibration standard was substituted for the LOD. The recoveries were between

167

57% and 106% for TCmX and between 63% and 120% for PCB 209. The reported

168

values were corrected for field blank levels (i.e. mean blank concentrations were

169

subtracted) but not for recovery. Duplicate results, listed in Table S6, indicate that the

170

average relative standard deviation (RSD) was mostly less than 30%, suggesting good

171

agreement between duplicate PASs. Uncertainties in chemical analysis are discussed

172

in Text S1 in the SI.

173

Comparison of POPs uptake by XAD-PAS under different modes of deployment

174

and in differently sloped terrain. In order to compare PAS deployment on a flat and

175

a sloped surface and with a straight and a slanted housing, four sets of XAD-PAS

176

(Figure 2B) were deployed in Nam Co, which among the three sites is the windiest

177

and the one with the most complicated terrain (Table S2). Site A was flat and site B

178

was on a natural slope facing North toward Nam Co lake (Figure 1a); at both sites a

179

straight PAS housing (situation 1 and 2 in Figure 2B) and one hanging at a 45° angle

180

facing the dominant wind direction (200 °) at Nam Co (situation 3 and 4 in Figure 2B)

181

were deployed. In contrast to an earlier indoor study using wind generated with a

182

large fan,13 our study represents realistic field conditions.

183

Sampler Design Modifications and Wind Influence Test. The design of the XAD-

184

PAS housing as described by Wania et al. (design A in SI Figure S1) was modified 7

ACS Paragon Plus Environment

Environmental Science & Technology

185

with the intention to reduce the influence of wind turbulence in both straight or

186

slanted deployment situations. The coarse mesh at the opening of the sampler housing

187

was replaced by a series of four stacked spoiler plates (design B in SI Figure S1)

188

designed to buffer the wind-driven, direct inflow of air into the housing. The spoiler

189

plates consist of metal sheets containing a variable number of round holes (8 mm in

190

diameter, 58, 43, 32, and 24 holes from top to bottom, SI Figure S1).

191

The efficiency of the spoiler in buffering the wind effect was tested by measuring the

192

internal and external wind speeds of the standard and modified XAD-PAS using a

193

method described in Text S2 and Figure S2. On the one hand, the gap width (1- or 2-

194

cm) between the spoiler plates was optimized to constrain internal wind speed to less

195

than ~ 0.1 m/s. On the other hand, the inner wind speed under straight and slanted

196

deployments was measured to test if the spoiler can fully eliminate the influence of

197

ambient wind turbulence. Similar to the standard XAD-PAS, the modified XAD-PAS

198

was deployed on a flat and a sloped surface and with a straight and a slanted housing

199

(situation 1-4 in Figure 2C) at Nam Co (windy place). PSRs were observed for the

200

modified XAD-PAS and compared with those of the standard XAD-PAS. The

201

modified XAD-PAS was also deployed at Lulang, in order to test its performance

202

under normal wind conditions.

203

Computational Fluid Dynamics Simulations. Computational Fluid Dynamics (CFD)

204

has become increasingly popular in environmental technology, especially in cases

205

where experimental data are difficult to obtain.27, 28 In this study, CFD simulations

206

were performed to assess the wind fields within the sampler housing when the

207

sampler is deployed in different environmental settings (forest, urban and mountain)

208

with variable ambient wind conditions. Additionally, CFD simulations were also

209

performed to investigate how the hanging mode of the sampler and sloped terrain

210

affect the wind field inside the PAS, particularly when the outside wind speed is high

211

(4.4 m/s in the second sampling period of Nam Co). Thirdly, the inner wind fields of

212

the modified XAD-PAS under the complex influence of wind and terrain were also

213

simulated. 8

ACS Paragon Plus Environment

Page 8 of 28

Page 9 of 28

Environmental Science & Technology

214

A two-dimensional domain was selected for the calculations, and the deployment

215

height of the sampler was set at 1.5m above ground, as is customary in field studies.

216

The domain was selected large enough for the sampler not to influence ambient wind

217

conditions. The standard k-ε model is utilized for k (turbulent kinetic energy) and ε

218

(rate of dissipation of k) to model continuous phase flow. Coupled equations were

219

used to conduct the pressure-velocity coupling and the wall function was applied for

220

the surface of the PAS housing. More detailed information on the CFD simulation is

221

given in Text S3, Figure S3 and Table S7.

222

Results and Discussion

223

Measured PSRs. The PSRs recorded at Lulang, Lhasa, and Nam Co are listed in

224

Tables S8, S9, and S10, respectively. The average PSR (i.e. the arithmetic mean of the

225

PSRs for the 11 analytes) in Lulang during the three sampling periods is relatively

226

constant, being 2.8, 2.3 and 2.4 m3/day for summer, autumn and winter, respectively

227

(Table S8). Similarly stable PSRs were also observed in Lhasa (Table S9). However,

228

the average PSR in Nam Co showed large variation, ranging from 5.2 to 22.6 m3/day

229

(Table S10). As mentioned above, the distinct features of Nam Co are high elevation

230

(4780 m), low temperature, low air pressure and strong winds. The highest average

231

PSR (22.6 m3/day) was measured in autumn when the highest wind speed (4.4m/s)

232

was recorded (Table S2 and S10). This suggests that varying meteorological factors

233

may impact the uptake in XAD-PAS during field deployments.

234

According to the conventional two-film theory, the PSR is proportional to a

235

chemical’s diffusivity in air (Dair). Field studies revealed positive correlations

236

between the PSR and Dair of a chemical.12, 15 Dair can be estimated using the Fuller,

237

Schettler, Giddings equation15:

238

  

 . !

" (2)

239

Where T is temperature (K), P is the pressure (hPa) and k is a constant. Therefore, the

240

PSR should be proportional to T1.75/P. In this study, if we consider PSRs from all 9

ACS Paragon Plus Environment

Environmental Science & Technology

Page 10 of 28

241

three sites (Table S8-10), the correlation between PSR and T1.75/P is poor (p> 0.05,

242

Student’s t test). However, if we only consider the PSRs at Lulang and Lhasa (i.e. the

243

less windy places) (Table S8-S9), a positive correlation is observed (p