FLORIDIN COMPANY

For r.p.m. counts, a 60-tooth gear on the trans- ducer or ... top rim sealed to prevent accidental overflow from wetting ... hinged bakelite top. 7. V...
0 downloads 0 Views 246KB Size
NEW

PRODUCTS

fast response with excellent stability. Provisions for attachment of a standard potentiometer recorder are included. 5 Self-Checking Electronic Tachometer

Unique circuitry in Standard Electric Time Co.'s new electronic tachometer permits self-checking for correct operation and accuracy. The Model ETC features a package-type plug-in assembly that enables unskilled personnel to

check operation in only a few minutes by replacement of any or all of nine separate electronic components. According to Standard, the ETC in operation counts r.p.m., rate, or frequency by counting electrical pulses for an accurately timed interval. From 10 to 50,000 pulses can be reported. The count is displayed directly on glow counter tubes and is said to be accurate to plus or minus one count. For r.p.m. counts, a 60-tooth gear on the transducer or generator is used. 6

MkimMa is a highly FOR

selective

adsorbent...

Apex Scientific's new mechanically refrigerated constant-temperature bath is applicable for temperatures from 0° to 150° C. and features a control accuracy of 0.002° C. For temperatures below ambient, the built-in mechanical refrigeration system operates continuously to maintain the temperature, and excess refrigeration is precisely balanced by conti'ol heaters. A built-in pumpstirrer combination supplies constanttemperature water to any exterior apparatus. The temperature-controlling mechanism is available in two models, one for on-off heater control when the bath is operating under a relatively constant heat load as in refractometry, and the other for use when the thermal load of the bath is suddenly and considerably

CHROMATOGRAPHY

A hard, porous, white granular synthetic adsorbent, produced in a variety of mesh classifications, Florisil is being successfully used in the most difficult separations of organic compounds. Originally recognized for chromatographic adsorption, Florisil is finding a variety of uses in research and manufacture. We also have available Fullers Earth and bauxite-based adsorbents for all types of adsorption filtration, including economical decolorization, dehydration and purification.

FLORIDIN COMPANY

Adsorbents Desiccanls Diluents j

Dept. X , Box 9 8 9 , Tallahassee, Fia. For further information, circle number 78 λ on Readers' Service Card, page 71 A

78 A

Mechanically Refrigerated Constant-Temperature Bath

changed, as in pyenometry. With the latter model the wattage of the control heater may be automatically varied from 0-300 watts which allows a controlled fast rate of heating or cooling. Refrigeration is furnished by a Vshp. sealed unit compressor using Freon 12 as a refrigerant. The condenser is air cooled by a motor-driven fan. The bath is constructed of stainless steel with the top rim sealed to prevent accidental overflow from wetting the glass w?ool insulation. The outer bath housing is of hammertoned steel with a divided hinged bakélite top. 7 Vacuum Measuring Gage

A new thermocouple vacuum gage said to provide an accurate and reliable means for vacuum measurement is announced by the Arthur F. Smith Co. The gage design provides for connection to continuous recording and controlling equipment, and reading accuracy is within 2%, the company says. The instrument is temperature compensating, and features a low- temperature thermocouple to ensure contamination-free readings. 8 For further information, see coupon on page 71 A ANALYTICAL

CHEMISTRY