Fully Automated Field-Deployable Bioaerosol Monitoring System using Carbon Nanotube-based Biosensors Junhyup Kim, Joon-Hyung Jin, Hyun Soo Kim, Wonbin Song, SuKyoung Shin, Hana Yi, Daeho Jang, Sehyun Shin, and Byung Yang Lee Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.5b06361 • Publication Date (Web): 12 Apr 2016 Downloaded from http://pubs.acs.org on April 15, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 31
Environmental Science & Technology
1
Fully Automated Field-Deployable Bioaerosol
2
Monitoring System using Carbon Nanotube-based
3
Biosensors
4
Junhyup Kim,† Joon-Hyung Jin,† Hyun Soo Kim,† Wonbin Song†, Su-Kyoung Shin,‡ Hana
5
Yi,‡ Dae-Ho Jang,† Sehyun Shin,† and Byung Yang Lee†*
6
†
Department of Mechanical Engineering, Korea University, Seoul 02841, Korea
7
‡
BK21PLUS Program in Embodiment: Health-Society Interaction, Department of Public
8
Health Sciences, Graduate School, Korea University, Seoul 02841, Korea
9
*To whom correspondence should be addressed. E-mail:
[email protected], Tel: +82 2 3290
10
3365
11
KEYWORDS: bioaerosol, fungi, real-time monitoring, carbon nanotube, field-effect
12
transistor
1 ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 31
13
ABSTRACT
14
Many progresses have been performed in the field of automated monitoring systems of
15
airborne pathogens. However, they still lack of the robustness and stability for field
16
deployment. Here, we demonstrate a bioaerosol auto-monitoring instrument (BAMI)
17
specifically designed for in-situ capturing and continuous monitoring of airborne fungal
18
particles. This was possible by developing highly sensitive and selective fungi sensors based
19
on two-channel carbon nanotube field-effect transistors (CNT-FETs), followed by integration
20
with a bioaerosol sampler, a Peltier cooler for receptor lifetime enhancement, and pumping
21
assembly for fluidic control. These four main components collectively cooperated with each
22
other to enable real-time monitoring of fungi. The two-channel CNT-FETs can detect two
23
different fungal species simultaneously. The Peltier cooler effectively lowers the working
24
temperature of the sensor device, resulting in extended sensor lifetime and receptor stability.
25
The system performance was verified in both laboratory conditions and real residential areas.
26
The system response was in accordance with reported fungal species distribution in the
27
environment. Our system is versatile enough that it can be easily modified for the monitoring
28
of other airborne pathogens. We expect that our system will expedite the development of
29
hand-held and portable systems for airborne bioaerosol monitoring.
2 ACS Paragon Plus Environment
Page 3 of 31
30
Environmental Science & Technology
INTRODUCTION
31
Bioaerosols, occupying a large portion of air pollutants, are air suspensions including a
32
variety of microbial particles such as bacteria, fungi, viral particles, pollens, and so forth.1
33
Among these airborne microbial particles, fungi are known as a one of major causes of
34
allergic disorders.2-4 Children, for example, who stay during most of their daily life in public
35
facilities such as schools or community centers are even more susceptible to fungal allergens
36
and have more probability of suffering from many pulmonary diseases caused by fungi
37
group.5 Indeed, fungus-originated allergens have currently attracted many attention due to
38
their adverse impacts on public health and indoor air quality.5 Therefore, we need a reliable
39
and robust monitoring systems for the early detection of hazardous allergenic fungi in the
40
environment. This will enable one to take active measures to reduce or remove those hazards
41
as soon as possible by methods such as filtering or ventilation.6, 7 Other laboratory bench-top
42
equipments involve techniques such as surface plasmon resonance,8 high performance liquid
43
chromatography,9 gas chromatography mass spectrometry10 and so on. However, although
44
these methods are highly sensitive and reliable, they are usually time consuming, costly, labor
45
intensive, and therefore, not applicable for in-situ real-time detection of allergenic
46
bioaerosols in the field. Meanwhile, new biosensors using nanoscale materials such as
47
nanoparticle,11 nanotube (NT),12 nanowire (NW),13 nanosheets and graphene14 as sensor
48
transducers have been demonstrated to have remarkable sensitivity, enabling sometimes
49
single molecule detection.15 In particular, nanobiosensors based on NT or NW-based field-
50
effect transistors (FETs) are suitable for miniaturization, mass production, and real time
51
monitoring, due to their compatibility with conventional microfabrication process and
52
versatile functionalization methods.16 However, these techniques are still in their
53
development stage and usually need further system integration for field deployment. A recent 3 ACS Paragon Plus Environment
Environmental Science & Technology
Page 4 of 31
54
work using nanomaterials demonstrated that airborne influenza virus particles can be
55
collected from air and detected by antibody immobilized Si NW FETs integrated with
56
microfluidic systems.17 However, their system was aimed to virus and limited in the long-
57
time stability and operation time needed for the continuous real-time monitoring of airborne
58
fungal allergens in real field situations.
59
In this work, we demonstrate a Bioaerosol Auto-Monitoring Instrument (BAMI) for real-time
60
detection of two kinds of allergenic fungal species, Aspergillus niger (A. niger) and
61
Alternaria alternata (A. alternata), which are related to various allergenic and pulmonary
62
diseases.18,
63
several days are demonstrated using the same sensor device. This was possible by developing
64
highly sensitive and selective nanomaterial-based biosensors for A. niger and A. alternata
65
based on carbon nanotube (CNT) FETs, combined with sensor cooling capabilities and a
66
microfluidic system that enables extensive washing of the sensor device for sensor
67
regeneration. The system was tested in real field conditions. The response in the field was in
68
accordance with reported fungal species distribution in the environment. Our system is
69
versatile enough and its use can be easily extended to detect microbial particles other than
70
fungi in the future. We expect that our system will expedite the development of hand-held
71
and portable systems for airborne allergenic fungi monitoring.
19
Sensor regeneration capabilities and extended system operation time up to
4 ACS Paragon Plus Environment
Page 5 of 31
Environmental Science & Technology
72
MATERIALS AND METHODS
73
A. Preparation of Target Fungal Solution
74
To perform quantitative experiments, we first prepared A. alternata solutions with known
75
concentration (in weight per volume) by carefully weighing the fungi amount using a ultra-
76
microbalance (XF2U, Mettler Toledo).20 The Alt a 1 mAb 121-immobilized CNT channel
77
was recorded as a function of time with continuous injection of 2 µL of different
78
concentrations of A. alternata suspended in 1 mM PBS solution at every 50 sec.
79
B. Activity Verification of A. alternata Antibody
80
The effect of temperature on antibody activity was determined using enzyme-linked
81
immunosorbent assay (ELISA). Alt a 1 monoclonal antibody (mAb, 1.83 mg/mL, Indoor
82
Biotechnologies, Inc.) was diluted in 50 mM carbonate-bicarbonate buffer (pH9.6) and added
83
in each well of microplate (NUNC Maxisorp, Nalgene). The plate was incubated overnight at
84
different temperatures (4, 25, 37 °C), then washed three times with 200 µL PBS washing
85
buffer with 0.05% Tween-20 (PBST) and blocked with 100 µL PBST solution with 1% BSA
86
(BSA/PBST) at various temperatures (4, 25, 37 °C) for 30 min. After washing three times
87
with 200 µL PBST, 100 µL aliquots of different concentrations of A. alternata cells (0.1 ~
88
100 µg/mL) in 1% BSA/PBST were then applied to each well and the plates were incubated
89
at different temperatures (4, 25, 37 °C) for 1 h. After washing three times with 200 µL PBST,
90
100 µL aliquots of 1000 times diluted biotinylated anti-Alt a 1 mAb (1 mg/mL) in 1%
91
BSA/PBST were added to each well of plate. Then, after washing the plates three times with
92
200 µL PBST, 100 µL aliquots of 1000 times diluted Streptavidin-peroxidase (Aldrich, Inc.,
93
0.25 mg/mL) in PBST was added and the plate was incubated at room temperature for 30 5 ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 31
94
min. Finally, after washing three times with PBST, 100 µL aliquots of 1 mM ABTS in 70
95
mM citrate phosphate buffer (pH 4.2) and 1000 times diluted hydrogen peroxide were added
96
to each well and the plate was incubated for 15 min at room temperature for blue-green color
97
development. The enzyme reaction was stopped by adding 100 µL 2% oxalic acid (Sigma).
98
The optical density (O. D.) at 405 nm (Figure 2) was read using a microplate reader Victor™
99
X3 (Perkin Elmer Inc., USA). In field tests, ELISA was carried out by coating 500 times
100
diluted Alt a 1 mAb to double the antibody concentration. Then, sampled solutions were
101
reacted for 2 h to double the reaction time. Finally, 100 µL aliquots of 1000 times diluted
102
hydrogen peroxide in 70 mM citrate phosphate buffer (pH 4.2) and 1 mM ABTS were added
103
to each well and left to react for 30 min.
104
C. Alexa Fluor Dye Labeling of Alt a 1 mAb
105
We prepared 1 mL of Alt a 1 mAb antibody solution of concentration 1 mg/mL, and then
106
added 100 µL of 1 M sodium bicarbonate solution. 100 µL of the Alt a 1 mAb antibody
107
solution was added to Alexa Fluor® dye tube and gently inverted a few times to mix and then
108
incubated for 1 h at room temperature. The purification column was assembled and 1.5 mL of
109
purification resin was applied to the column. The purification was then centrifuged for 3 min
110
at 1100 G. G represents gravitational constant. Afterwards, 100 µL of the dye-conjugated
111
antibody solution was applied to the purification column and centrifuged for 5 min at 1100 G
112
to collect the dye-labeled antibody solution. The fluorescence image was taken with Nikon
113
eclipse LV100ND optical microscope with excitation wavelength at 510–560 nm and
114
exposure time = 60 sec.
115
D. CNT-FET Preparation
6 ACS Paragon Plus Environment
Page 7 of 31
Environmental Science & Technology
116
We prepared the CNT-FET following a previously reported process.20 Briefly, the CNT-FETs
117
were fabricated on a highly doped p-type silicon wafer with 300 nm thick thermal oxide
118
(SiO2). Carboxylic acid functionalized single-walled CNTs (> 90%, Aldrich, Inc.) were
119
patterned to form a channel of 3 µm width and 10 µm length utilizing directed assembly on a
120
molecularly patterned substrate with octadecyltrichlorosilane (> 90%, Aldrich, Inc.). Source
121
and drain electrodes consisting of 30 nm-thick Au films over 5 nm-thick Cr adhesion layer
122
were fabricated by conventional metal evaporation and lift-off process.
123
E. Functionalization of CNT-FETs with Primary Antibody
124
For antibody immobilization, the carboxyl-functionalized CNT surface was treated with 1-
125
ethyl-3-(3-dimethylaminopropyl)-carbodiimide
126
(Aldrich, Inc.) chemistry to anchor the antibodies to the carboxyl-functionalized CNT
127
surface.21 Antibodies for selective detection of A. niger and A. alternata were purchased from
128
Bio-Rad Laboratories, Inc. and Indoor Biotechnologies, Ltd., respectively. As described
129
above, our sensor device was comprised of two CNT channels, each one immobilized with
130
different kind of antibodies. In channel 1, antibodies (Alt a 1 monoclonal antibody (mAb))
131
that specifically binds to the A. alternata coat protein (Alt a 1 Immunogen) were immobilized
132
on the CNT-FET using EDC/NHS chemistry. For this purpose, the CNT-FET were immersed
133
in 0.2 M/0.1 M EDC/NHS in 10 mM PBS for 4 h at room temperature. The EDC/NHS
134
process enables substitution of the hydroxyl group of the carboxylic acid group with a more
135
facile leaving group, i.e., NHS group. The mAb solution was prepared by diluting the as-
136
received antibody solution by 1000 times in 1% BSA, 50% glycerol, 49% 1 mM pH 7.4 PBS
137
buffer mixture, filtered by a 0.2 µm pore size filter. This antibody solution was dropped on
138
the EDC/NHS-treated CNT-FET and kept for 4 h. In this process, the N-terminal of the
139
antibody formed a strong amide bond with the carbonyl carbon of the CNT-FET. The
(EDC)/N-hydroxysuccinimide
(NHS)
7 ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 31
140
resulting antibody-immobilized CNT-FET devices were stored at 4 ºC before use. In channel
141
2, an antibody (WF-AF-1) that specifically binds to the A. niger coat protein (galactomannan)
142
was immobilized on the CNT-FET using EDC/NHS chemistry. We followed a previously
143
reported process.20 The WF-AF-1 antibody solution was prepared by diluting the as-received
144
antibody solution by 10 times in 1 mM PBS buffer solution. Phosphate-buffered saline (PBS,
145
pH 7.4) solution was purchased from Aldrich, Inc.
146
F. Liquid Gating Experiments
147
The liquid gating experiments on A. alternata sensor was performed by first preparing a
148
CNT-FET immobilized with an A. alternata antibody (Alt a 1 mAb). Then, 10 µL of 1 mM
149
PBS buffer was dropped on the sensor region. The source-drain bias was maintained at 0.1 V.
150
A cyclic liquid gate voltage from -0.5 to 0.5 V was applied using a Pt pseudo-reference
151
electrode. All the application of voltage and current monitoring was performed using a
152
semiconductor parameter analyzer (4200-SCS, Keithley, USA). To observe the effect of
153
nonspecific target, 5 µL of 10 pg/mL A. niger solution was applied to the PBS buffer droplet.
154
The gating scan did not show any significant shift in the gating curve (Figure 4C). However,
155
when we applied another 5 µL of 10 pg/mL A. alternata solution, the current increased and
156
the gating curve shifted upwards, which is due to the gating effect of the negatively charged
157
fungi fragments to the p-type CNT-FET. In case of A. niger sensors, the liquid gating
158
experiments were performed in the same method as above, only the sample being
159
immobilized with A. niger antibody (WF-AF 1), as shown in Figure S4.
160
G. BAMI System Configuration
161
A photo image of the BAMI is shown in SI Figure S5. The base vessel of the bioaerosol
162
sampler was modified from its original form by using an acryl vessel attached with four 8 ACS Paragon Plus Environment
Page 9 of 31
Environmental Science & Technology
163
fluidic channels at the vessel bottom using silicon tubing (inner diameter = 1 mm), each one
164
connected to four peristaltic pumps (P1, P2, P3, P4). Note that this modification enabled
165
washing the vessel with PBS buffer solution and resampling of the fungal solution. The
166
pumping actions of the four peristaltic pumps were completely controlled by built-in micro
167
controller unit (MSP430, Texas Instruments, Inc.) communicating through RS-232 cable with
168
a PC running a serial communication program. Each peristaltic pump can be separately
169
operated by a switching relay. P1 supplies fresh PBS solution from the buffer reservoir to
170
bioaerosol sampler base with a flow rate of 10 mL/min. P2 can drain the buffer from
171
bioaerosol sampler base with a flow rate of 10 mL/min. P3 and P4 supply fungi-suspended
172
buffer solution to the channels 1 and 2 of the CNT-FET sensor module (SI Figure S8),
173
respectively, through polyether ether ketone-based microfluidic channels with flow rates of 1
174
mL/min, corresponding to a flow velocity of 13 mm/s. The sensor response of the CNT-FETs
175
was measured by monitoring the current change of each device under a DC bias of 0.1 V.
176
Current-time characteristics of the CNT-FETs were recorded using a Keithley 2636A dual-
177
channel sourcemeter driven by LabVIEW software. The Peltier cooler is in contact with the
178
CNT-FET holder from the bottom side. A heat sink is in close contact with the cooler.
179
Proportional-integral-derivative controller sets up a temperature, receives feedback
180
temperature from the heat sensor installed in the CNT-FET sensor holder, and eventually
181
controls the cooling temperature by turning on/off the power supply on the basis of the pulse
182
width modulation.
183
9 ACS Paragon Plus Environment
Environmental Science & Technology
Page 10 of 31
184
RESULTS AND DISCUSSION
185
Figure 1 shows the functional diagram of the BAMI composed of a bioaerosol sampler based
186
on a commercial air-to-liquid impactor (BioSampler®, SKC Inc), a microfluidic assembly
187
including four peristaltic pumps for injection and withdrawal of the sampled fungal solution,
188
two-channel CNT-FET-based detection circuitry for the detection of both A. niger and A.
189
alternata, Peltier cooling for receptor lifetime elongation, and PC-based electronic control
190
system. Here, we developed a novel biosensor for A. alternata and combined it with a
191
previously reported sensor for A. niger.20 The CNT-FETs were combined with Peltier cooler,
192
and then integrated with microfluidics and modified the bioaerosol sampler. The Peltier
193
cooler has two effects: that of precooling the fungal solution before being injected to the
194
CNT-FETs, and that of lowering the operation temperature of the immobilized antibodies.
195
The sampled solution reaches the sensing surface through the cold side of the Peltier cooler to
196
cool down the solution in advance to a temperature compatible to that of the CNT-FET
197
sensor. To verify the activity of the Alt a 1 mAb and identify the optimum operation
198
temperature, we performed sandwich ELISA experiments in three different temperature
199
conditions (Figure 2). The A. alternata antibody showed enhanced binding activity as we
200
lowered the temperature from 37 ºC to 4 ºC. Since the antibody lifetime in general is known
201
to elongate as temperature is lowered,22 and the binding activity for A. alternata was
202
enhanced at lower temperatures of 4 ºC, this justifies the usage of a Peltier cooler in our
203
BAMI system.
204
The CNT-FETs were prepared by previously reported methods.20 The CNT-FETs were
205
produced in wafer-scale (SI Figure S1). Each device had two parallel channels, each channel
206
composed of single-walled CNT network channels of with 10 µm length and 3 µm width (SI
207
Figure S1 (A-B)). The IV characteristics showed a current of ~3.2 µA at 1 V (SI Figure S1 10 ACS Paragon Plus Environment
Page 11 of 31
Environmental Science & Technology
208
(C)). The resistance distribution was in the range of 3.6 ± 2.5 MΩ (SI Figure S1 (D)). The
209
gate characteristics showed a current on-off ratio of 2~3 in air and liquid gating conditions
210
(SI Figure S1 (E-F)). Afterwards, the antibodies were immobilized onto CNT-FETs using
211
EDC/NHS chemistry to prepare the A. alternata biosensors. The antibody immobilization
212
was verified with atomic force microscopy and fluorescence imaging (Figure 3). As shown in
213
Figure 3 (A-C), the topography showed increase of height by ~5 nm after antibody
214
immobilization, which is similar to the reported size of the immunoglobulin G (IgG) such as
215
Alt a 1 mAb.23 The binding activity of immobilized antibodies was confirmed by exposing
216
the antibody-immobilized CNT to A. alternata solution and then conjugating it with Alexa-
217
Fluor labeled secondary antibody. Figure 3 (D) shows that the fluorescence is maximum at
218
the CNT-channel region. The non-specific binding was confirmed by performing a negative
219
control experiment where no primary antibody was immobilized on the CNT-FET. When
220
there was no primary antibodies immobilized, we could not observe any significant
221
fluorescence intensity on the CNT regions (Figure S2). It should be noted that the images in
222
Figure 3 reflects the binding of the antibody with fungi fragments and not with whole spores.
223
It is known that airborne particles of A. niger and A. alternata fungi are composed of both
224
spores/hyphae and fragments of them.24 And these fragments, in contrast to viruses which are
225
infectious only as whole viruses, play the role as pathogens that cause atopic dermatitis,
226
allergy and pulmonary diseases such as asthma and pneumonia.25 Also, the size of A. niger
227
and A. alternata spores are in the range of 3 µm and 15 µm, respectively,26, 27 which makes
228
the direct binding event between antibody and spores difficult. Therefore, the primary target
229
material of our sensors were fungal fragments and not spores or hyphae.
230
The sensitivity and selectivity of the A. alternata biosensor was first tested (Figure 4). Figure
231
4 (A) shows that the sensor response was linearly proportional to the A. alternata 11 ACS Paragon Plus Environment
Environmental Science & Technology
232
concentration in the range from 10 pg/mL to 1 µg/mL. The limit of detection, defined here as
233
the minimum target concentration resulting in a detectable sensor response, was 10 pg/mL.
234
Furthermore, the detection limit was two-fold lower, compared with new immunoassay
235
method.28 Here, we maximized the sensitivity by increasing the Debye length around the
236
CNTs using diluted PBS buffer at 1 mM ionic concentration. This results in extended sensing
237
region around the CNTs at liquid conditions.29 The Debye length at 1 mM PBS buffer can be
238
estimated to be about 9.7 nm.30 Since Alt 1 mAb is an IgG type antibody which has a planar
239
structure with diameter of ~8.5 nm and thickness of ~4 nm, we can expect IgG antibodies to
240
be immobilized around the CNTs with random direction while providing multiple binding
241
sites within the Debye length.23, 29, 30 The current increase with increasing concentration can
242
be explained from electrostatic gating effect from the A. alternata spores and fragments.
243
Since our sensors show quasi-linear response to log-concentration (inset of Figure 4 (A)), and
244
both spores and hyphae contribute to the concentration, the signal reflects the total amount of
245
allergens in air. In neutral pH, the surface of A. alternata is negatively charged because the
246
isoelectric point of the A. alternata is around 4.2.31 The negatively charged A. alternata
247
spores and fragments apply a negative gating effect to the p-type CNT channel (SI Figure S1
248
(E)), and therefore, the current is increased in the CNT-FET channel. The sensor showed a
249
large dynamic range of fungi concentration in the range of 10 pg/mL to 1 µg/mL with 65%
250
total signal change (Figure 4 (A)). The conversion between mass concentration to actual
251
spore number per volume needs additional parameters such as the ratio of spore to fragment
252
that gets sampled into the PBS buffer during aerosol sampling for each fungal species and the
253
fraction of fragments bound to the immobilized antibody that contribute to signal change,
254
which is left for further study. As shown in Figure 4 (B), the selectivity of A. alternata sensor
255
was tested by consequently injecting a set of predesigned mixture solutions of four different
256
kinds of fungi: A. alternata, A. niger, Cladosporium cladosporioides (C. cladosporioides), 12 ACS Paragon Plus Environment
Page 12 of 31
Page 13 of 31
Environmental Science & Technology
257
and Penicillium chrysogenum (P. chrysogenum). The sensor showed no response to the first
258
two mixtures containing no A. alternata. However, the electrical signal showed increasing
259
sensor response to the last two mixtures that contained A. alternata of concentrations of 10
260
and 100 pg/mL. Also, the selectivity was observed by liquid gating experiments (Figure 4
261
(C)). The liquid gate characteristics showed a typical p-type channel behavior. When exposed
262
to A. niger, the gate characteristics showed almost no change. However, when the sensor was
263
exposed to the target fungi A. alternata, the sensor showed a rightward shift of the threshold
264
voltage due to the hole enhancement effect by the negatively charged A. alternata
265
fragments.32 For A. alternata sensor, sensor regeneration experiment was performed up to
266
several times (Figure 4 (D)). However, the sensor showed reduced sensitivity with repeated
267
number of washing. We expect that the number of repetitive regeneration can be increased
268
with the utilization of more robust synthetic receptors in the future.
269
The A. alternata sensor developed above was combined with A. niger sensor previously
270
developed20 on each channel of the CNT-FET devices. The sensor for the A. niger also
271
showed increasing current with the addition of A. niger solution in the concentration range of
272
10 pg/mL to 1 µg/mL in the same way as A. alternata sensor (Figure S3). The liquid gating
273
characteristics of A. niger sensors showed similar sensitivity and selectivity as reported
274
before (SI Figure S4).20 These devices were combined with a bioaerosol sampler, Peltier
275
cooler and microfluidic systems to build BAMI for the real-time monitoring of airborne fungi
276
(SI Figure S5). The Peltier cooler provides the BAMI with control of operation temperature,
277
allowing an optimized condition for detection and receptor lifetime elongation. This function
278
is expected to be particularly useful for biosensing applications using protein-based receptors,
279
because biomacromolecules such as enzymes and antibodies frequently demand a particular
280
temperature
and
a
pH
for
best
performance
of
the
immobilized
functional 13
ACS Paragon Plus Environment
Environmental Science & Technology
Page 14 of 31
281
biomacromolecules.33 Actual surface temperature of the Peltier cooler was confirmed with a
282
thermocouple, resulting at temperatures of 6±0.5 °C, 25±0.2 °C, and 35±0.5 °C for set
283
temperatures of 4, 25, and 37 °C, respectively. The Alt a 1 mAb showed its maximum
284
activity at 4 °C (Figure 2), meaning that a low temperature operation enabled by the Peltier
285
cooler allows enhanced antibody lifetime and more sensitive binding activity of the receptors.
286
The operation of the microfluidics system was verified by observing the direct response to
287
ammonium hydroxide solutions of concentrations in the range of 100 nM to 10 mM
288
concentration with devices with bare CNTs (SI Figure S6). Decrease of CNT conductivity
289
with increased ammonium hydroxide solution is known to be due to electron donating
290
property of ammonium to the CNTs.34 The stability of the A. alternata antibody-
291
functionalized sensor was verified by exposing the sensor to target fungi and comparing the
292
sensor response at two different temperatures of 4 and 25 ºC for more than 5 days (Figure 5).
293
When the sensor was kept at 25 ºC, the sensor response drooped after ~1 day, presumably
294
due to denaturation of the antibodies. However, when the sensor was kept at 4 ºC, the sensor
295
response maintained constant for up to 9 days (data only shown up to 5 days), showing the
296
effectiveness of lowering the sensor operation temperature using a cooler.
297
The sensitivity and selectivity of the sensors were verified by injecting solutions of fungi
298
solutions with known concentrations to the sampler vessel and transported to the CNT-FET
299
by the microfluidic system (Figure 6). First, the sensor response of the A. niger sensor in the
300
range of 10 pg/mL to 1 ng/mL concentration is shown in Figure 6 (A). In contrast, when we
301
introduced just PBS buffer, the A. niger sensor showed no response. Also, the selectivity of
302
the A. niger sensor was verified by injecting solutions of other fungal species. The sensor
303
showed no response to other fungal species such as A. alternata or C. cladosporioides (SI
304
Figure S7). Next, the operation of the A. alternata was observed in the range of 10 pg/mL to 14 ACS Paragon Plus Environment
Page 15 of 31
Environmental Science & Technology
305
100 ng/mL concentration (Figure 6 (B)). Note that the signal change is in accordance with
306
Figure 4 (B). The sensor response showed a fast average rising time of ~20 sec. When the
307
sensor was washed with PBS using the microfluidic system, the sensor response returned to
308
its initial value with an average falling time of ~2 min. Here, the rising and falling time has
309
been defined as the time required to change between 10% and 90% of the sensor response.
310
This sensor recovery is probably due to moderate binding affinity and washing.35 Note that
311
the sensor recovery characteristics is an important function that enables regeneration and
312
lifetime elongation of the sensor device. The simultaneous operation of A. niger and A.
313
alternata sensors are shown in Figure 6 (C). Here, we subsequently introduced 10 pg/mL A.
314
niger and 10 pg/mL A. alternata, followed by PBS in intervals of 5 min. We can observe the
315
sequential selective response of each sensor to their target and simultaneous recovery to their
316
initial values when washed with PBS. We tested the selective sensor response in the presence
317
of two additional interferent fungal species: C. cladosporioides and P. chrysogenum (Figure 6
318
(D)). The four mixtures in Figure 6 (D) were applied additively. It shows that the sensor
319
response only depends on the concentration of the specific target. These results show that our
320
BAMI is effective in detecting fungal allergenic particles with extended sensor lifetime
321
enabled by sensor cooling and washing system.
322
The overall performance of the BAMI system including the sampler was tested in laboratory
323
conditions by placing the BAMI system inside a homemade acryl chamber (size 300 × 300 ×
324
500 mm) and exposing it to dish-cultured fungi to avoid contamination from other
325
interferents (SI Figure S8 (A)). The bioaerosol sampler vessel contained 40 mL of D.I. water
326
at the beginning of the experiment, and the volumetric flow rate from the bioaerosol sampler
327
to the CNT-FET was 1 mL/min. To apply a fungal bioaerosol input to the bioaerosol sampler
328
in a consistent way, we sampled the dish-cultured fungi by setting colony size criteria. For A. 15 ACS Paragon Plus Environment
Environmental Science & Technology
Page 16 of 31
329
niger, a drop (1 mL) of A. niger suspension was spread on a agar plate (DifcoTM malt extract),
330
and left to grow for 7 days. Among the A. niger colonies, those 10 colonies with a size
331
smaller than 1 mm in diameter were carefully sampled with cotton ball and placed into a
332
specifically-designed glass pre-chamber connected in front of the bioaerosol sampler. For A.
333
alternata, we followed the same procedure as A. niger. However, the sampled colonies had
334
diameter around 1 cm, considering the size difference between A. niger and A. alternata
335
spores, the latter being ~5 times bigger in diameter compared to the former.26, 27 After placing
336
the sampled cotton ball in front of the bioaerosol sampler, we turned on the bioaerosol
337
sampler. After operating the bioaerosol sampler for 5 min, the sampled fungal solution in
338
PBS was transported to the CNT-FET device by the microfluidic system. For initial 5 min,
339
the BAMI was operated to sample A. niger (SI Figure S8 (B), red) or A. alternata (SI Figure
340
S8 (B), blue) fungi species in 30 sec intervals. Each curve reached its maximum in around 5
341
min. This implies the system requires at least 5 mL of a sample solution considering the fluid
342
flow rate. After detection, the pumping system was operated to supply pure buffer solution to
343
the fungi sensor for sensor regeneration. As control experiment, no current change was
344
observed when we supplied clean buffer to the fungi sensor (SI Figure S8 (B), black). These
345
results imply that our BAMI is effective in detecting fungal spore/hyphae fragments with
346
extended sensor lifetime enabled by sensor cooling and washing system.
347
Finally, we field-tested the BAMI system in real residential areas to verify the field
348
deployment capability of the system. We chose two different locations for comparison (SI
349
Figure S9). One location was at a basement level of a building with considerable fungi
350
contamination, while the other was in upper level of a building with no observable fungal
351
growth. The sampler was operated for 5 min at 12.5 L/min aspiration rate to concentrate
352
environmental fungi in the PBS. Afterwards, the sampling was stopped and the sampled 16 ACS Paragon Plus Environment
Page 17 of 31
Environmental Science & Technology
353
solution was injected to the antibody-immobilized CNT-FETs by the microfluidic channels.
354
This sequence was repeated on already existing fungal solution to gradually increase the
355
fungal concentration in the PBS solution. It should be noted that the system can in principle
356
sample and detect at the same time (Figure S8). Here, the system was not operated in that
357
way to ensure sufficient sampling of fungal fragments. Figure 7 (A) shows the BAMI
358
response at different environmental conditions. In case of A. niger, the signal increased faster
359
than that of A. alternata at both locations. The signal saturated after the signal changed by
360
~80%. This relatively higher response compared to A. alternata is expected since A. niger is
361
known to be an indoor-originated fungi. In contrast, the A. alternata response was lower than
362
A. niger in both locations, and the A. alternata response was lowest at upper level residence.
363
This is expected since A. alternata is outdoor-originated fungal species.33 The fungal solution
364
collected by the sampler was verified to contain the target fungal species by ELISA and
365
morphological analysis. The sampled solution were analyzed with ELISA and the O. D. was
366
observed to increase at extended sampling time and therefore at higher fungal concentrations
367
(Figure 7 (B)). Also, the fungal species after 5-day incubation at 25 ºC showed to contain
368
both Aspergillus and Alternaria species when their morphology was inspected by SEM and
369
optical image (SI Figure S10).36-39 Finally, a control experiment was performed to observe
370
the effect of ambient pollutants such as gases and dust particles to the sensor response (SI
371
Figure S11). Ambient indoor air was sampled using the BiosamplerTM at 12.5 mL/min
372
aspiration rate for 5 min to prepare a bioaerosol solution in PBS buffer in the same way as
373
Figure 7. The solution was then filtered with 0.02 µm pore size filter (Anodisc 47, Whatman,
374
USA) to eliminate any particles larger than 0.02 µm including fungal spores and their
375
fragments. The sensor was an A. niger sensor with antibody WF-AF-1 immobilized on the
376
CNT-FET. The sensor showed no response to the filtered solution. This shows that the sensor
377
response is not due to ambient gases or particles smaller than 0.02 µm in size. 17 ACS Paragon Plus Environment
Environmental Science & Technology
Page 18 of 31
378
A practical fungi biosensor should be able to monitor fungi concentration in real-time, while
379
enabling in-situ and real-time bioaerosol sampling, high sensitivity towards target fungi,
380
selectivity towards target, and acceptable sensor life-time. The protein-based receptors such
381
as antibodies can provide high selectivity when combined with highly sensitive nanomaterials
382
such as CNTs. However, their proper binding will happen only at adequate working
383
temperatures and pH values. Therefore, we developed the BAMI by combining bioaerosol
384
sampler, Peltier cooler, microfluidic system, and CNT-FET to enable air-to-liquid sampling
385
of airborne fungi particles, sensor life-time elongation, fungi solution transport, sensor
386
regeneration and nanomaterial-based sensitive detection of fungal particles. The BAMI
387
system additionally supports device regeneration option, and is perfectly compatible with any
388
micro/nano bio devices. Future work will involve the introduction of miniaturized sampling
389
system and pre-filtering process to eliminate dust particles and other interferents from fungal
390
particles. Our system is versatile enough that it can be easily expanded for the monitoring of
391
other airborne pathogens. We expect that our system will expedite the development of hand-
392
held and portable systems for airborne bioaerosol monitoring.
393 394
Acknowledgments
395
This project was supported by the Center for Integrated Smart Sensors funded by the Ministry
396
of Science, ICT & Future Planning as Global Frontier Project (CISS-2011-0031866) and by
397
National Research Foundation (2015R1A2A2A04002733).
18 ACS Paragon Plus Environment
Page 19 of 31
Environmental Science & Technology
398
Supporting Information
399 400 401 402 403 404 405 406
Figures showing the basic electrical characteristics of CNT-FET devices. Fluorescence image of a CNT-FET with no primary antibody immobilized. Real-time response of A. nigerspecific sensor. Liquid gate characteristics of A. niger-specific sensor. Photo image showing the BAMI system. Figures showing selectivity results of A. niger sensor, chamber test using BAMI systemc, and optical images of field test location for BAMI system. Optical and SEM images for morphological analysis of Aspergillus and Alternaria species for samples collected from the field test locations using conventional impactor. This information is available free of charge via the Internet at http://pubs.acs.org/.
407 408
Notes
409
The authors declare no competing financial interest.
19 ACS Paragon Plus Environment
Environmental Science & Technology
Page 20 of 31
410 411
412 413
Figure 1. Schematic block diagram of bioaerosol auto-monitoring instrument (BAMI)
414
composed of bioaerosol sampler, pumping assembly, Peltier cooler, and carbon nanotube
415
field-effect transistor (CNT-FET) biosensor module. The bioaerosol sampler preconcentrates
416
the airborne fungi into PBS buffer. Peristaltic pumps P1 and P2 enable the washing of the
417
collecting vessel. Peristaltic pumps P3 and P4 inject the preconcentrated fungi solution to the
418
two-channel sensing module, composed of two-channel CNT-FETs, each immobilized with
419
selective receptor (antibody) to fungi Aspergillus niger (A. niger) and Alternaria alternata (A.
420
alternata), respectively. A Peltier cooler maintains the sensing module to a low temperature
421
(~4 ºC) to enhance the binding efficiency and extend the lifetime of the antibodies.
422
20 ACS Paragon Plus Environment
Page 21 of 31
Environmental Science & Technology
423 424
Figure 2. Enzyme-linked immunosorbent assay (ELISA) measurements for testing antibody
425
activity of A. alternata antibody (Alt a 1 monoclonal antibody (mAb)) at three different
426
temperatures of 4 ºC, 25 ºC, and 37 ºC. The optical density (O. D.) of each reaction well was
427
read at 405 nm wavelength. The antibody showed enhanced binding activity at lower
428
temperatures.
429
21 ACS Paragon Plus Environment
Environmental Science & Technology
Page 22 of 31
430 431
Figure 3. Verification of antibody immobilization to CNT-FET and target-receptor binding.
432
(A) Atomic force microscopy (AFM) image of the CNT-FET channel. (B) AFM image of the
433
CNT-FET channel immobilized with A. alternata antibody (Alt a 1 mAb). (C) Comparison of
434
height profiles before and after target binding. (D) Fluorescence microscopy image of CNT-
435
FET sensor after fungal fragment binding followed by conjugation with Alexa Fluor®-568
436
labeled secondary antibody.
437
22 ACS Paragon Plus Environment
Page 23 of 31
Environmental Science & Technology
438 439
Figure 4. Sensitivity and selectivity of A. alternata sensor. (A) Real-time response of A.
440
alternata antibody (Alt a1 mAb)-immobilized CNT-FET device to consecutive injection of A.
441
alternata suspension in PBS solution of various concentrations (each injection volume = 2
442
µL). Note that the initial volume of the 1 mM pH 7.4 PBS solution on the device is 2 µL.
443
(Inset) Corresponding calibration curve. The x-axis values are the injected A. alternata
444
concentrations from 10 pg/mL to 1 µg/mL differing by ten times. (B) Sequential injection of
445
four different mixtures of fungal solutions. The first two mixtures contain no A. alternata,
446
while the last two mixtures contain A. alternata of concentrations differing by 10 times (10
447
and 100 pg/mL, respectively). Here, A: A. alternata, B: A. niger, C: P. chrysogenum, D: C.
448
cladosporioides. (C) Liquid gate characteristics change of our sensor to target and non-target 23 ACS Paragon Plus Environment
Environmental Science & Technology
Page 24 of 31
449
fungi. Injection volume and concentration were always 5 µL and 10 pg/mL, respectively.
450
Here, Vds = 0.1 V, and initial volume of PBS was 10 µL. (D) A. alternata sensor regeneration
451
test.
452
Afterwards, 2 µL of 10 pg/mL A. alternata solution was applied. After 50 sec, the sensor was
453
extensively washed with PBS buffer to recover the initial sensor signal level. This process
454
can be repeated for several times before the sensor sensitivity is reduced.
Initially, a 2 µL of PBS droplet was applied on the antibody-immobilized CNT-FET.
455
24 ACS Paragon Plus Environment
Page 25 of 31
Environmental Science & Technology
456 457
Figure 5. Dependence of stability of antibody-immobilized CNT-FET sensor on temperature.
458
The sensor was exposed to A. alternata and kept at 4 ºC and 25 ºC, respectively, for 5 days.
25 ACS Paragon Plus Environment
Environmental Science & Technology
Page 26 of 31
459 460
Figure 6. Response of BAMI system to pure and mixtured fungal solutions. (A) Normalized
461
conductance change time of the A. niger sensor to target concentrations from 10 pg/mL to 1
462
ng/mL, followed by sensor regeneration process composed of PBS washing. (B) Sensitivity
463
of A. alternata sensor to various target concentrations followed by sensor regeneration. (C)
464
Simultaneous response of the two-channel A. niger and A. alternata sensor to sequential
465
injection of A. niger and A. alternata followed by sensor regeneration with PBS washing. (D)
466
Two-channel sensor response to sequential injection of mixtures of four fungal species. The
467
mixtures were applied additively. In case of A. niger antibody-immobilized CNT-FET, it
468
responded to A. niger only. Meanwhile, the A. alternata antibody-immobilized CNT-FET
469
responded to A. alternata only. (A: A. niger; B: A. alternata; C: C. cladosporioides; D: P.
470
chrysogenum)
26 ACS Paragon Plus Environment
Page 27 of 31
Environmental Science & Technology
471 472
Figure 7. Field testing of BAMI system in indoor residential areas. (A) Operation of BAMI
473
system at indoor residential areas. The response at basement residential area (green/red) and
474
upper level residential area (magenta/blue) of A. niger/A. alternata sensor were compared to
475
chamber conditions (black) with no fungi. (B) ELISA measurements on A. alternata content
476
of the sampled solution in (A). The fungal solution collected by the sampler was verified to
477
contain A. alternata fungal species with increased concentrations with sampling time.
27 ACS Paragon Plus Environment
Environmental Science & Technology
478
Page 28 of 31
TOC
479 480
28 ACS Paragon Plus Environment
Page 29 of 31
Environmental Science & Technology
481
REFERENCE
482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527
1. Kalogerakis, N.; Paschali, D.; Lekaditis, V.; Pantidou, A.; Eleftheriadis, K.; Lazaridis, M., Indoor air quality—bioaerosol measurements in domestic and office premises. J. Aerosol. Sci. 2005, 36 (5–6), 751-761. 2. Simon-Nobbe, B.; Denk, U.; Pöll, V.; Rid, R.; Breitenbach, M., The spectrum of fungal allergy. Int. Arch. Allergy Immunol. 2007, 145 (1), 58-86. 3. Mendell, M. J.; Mirer, A. G.; Cheung, K.; Douwes, J., Respiratory and allergic health effects of dampness, mold, and dampness-related agents: a review of the epidemiologic evidence. Environ. Health Perspect. 2011, 119 (6), 748. 4. Enoch, D.; Ludlam, H.; Brown, N., Invasive fungal infections: a review of epidemiology and management options. J. Med. Microbiol. 2006, 55 (7), 809-818. 5. Garrett, M.; Rayment, P.; Hooper, M.; Abramson, M.; Hooper, B., Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children. Clin. Exp. Allergy 1998, 28 (4), 459-467. 6. Li, J.; Li, M.; Shen, F.; Zou, Z.; Yao, M.; Wu, C.-y., Characterization of Biological Aerosol Exposure Risks from Automobile Air Conditioning System Environ. Sci. Technol. 2013, 47 (18), 10660-10666. 7. Yamamoto, N.; Hospodsky, D.; Dannemiller, K. C.; Nazaroff, W. W.; Peccia, J., Indoor Emissions as a Primary Source of Airborne Allergenic Fungal Particles in Classrooms. Environ. Sci. Technol. 2015, 49 (8), 5098-5106. 8. Dostálek, J.; Homola, J.; Miler, M., Rich information format surface plasmon resonance biosensor based on array of diffraction gratings. Sens. Actuator B-Chem. 2005, 107 (1), 154-161. 9. Frelon, S.; Douki, T.; Ravanat, J.-L.; Pouget, J.-P.; Tornabene, C.; Cadet, J., Highperformance liquid chromatography-tandem mass spectrometry measurement of radiationinduced base damage to isolated and cellular DNA. Chem. Res. Toxicol. 2000, 13 (10), 10021010. 10. Chan, E. C. Y.; Pasikanti, K. K.; Nicholson, J. K., Global urinary metabolic profiling procedures using gas chromatography-mass spectrometry. Nat. Protoc. 2011, 6 (10), 14831499. 11. Pelaz, B.; Charron, G.; Pfeiffer, C.; Zhao, Y.; de la Fuente, J. M.; Liang, X. J.; Parak, W. J.; del Pino, P., Interfacing engineered nanoparticles with biological systems: anticipating adverse nano–bio interactions. Small 2013, 9 (9‐10), 1573-1584. 12. Mani, V.; Devadas, B.; Chen, S.-M., Direct electrochemistry of glucose oxidase at electrochemically reduced graphene oxide-multiwalled carbon nanotubes hybrid material modified electrode for glucose biosensor. Biosens. Bioelectron. 2013, 41, 309-315. 13. Gao, A.; Lu, N.; Wang, Y.; Dai, P.; Li, T.; Gao, X.; Wang, Y.; Fan, C., Enhanced sensing of nucleic acids with silicon nanowire field effect transistor biosensors. Nano Lett. 2012, 12 (10), 5262-5268. 14. Khatayevich, D.; Page, T.; Gresswell, C.; Hayamizu, Y.; Grady, W.; Sarikaya, M., Selective Detection of Target Proteins by Peptide‐Enabled Graphene Biosensor. Small 2014, 10 (8), 1505-1513. 15. Sorgenfrei, S.; Chiu, C.-y.; Gonzalez Jr, R. L.; Yu, Y.-J.; Kim, P.; Nuckolls, C.; Shepard, K. L., Label-free single-molecule detection of DNA-hybridization kinetics with a carbon nanotube field-effect transistor. Nature nanotech. 2011, 6 (2), 126-132. 16. Mun'delanji, C. V.; Kerman, K.; Hsing, I.-M.; Tamiya, E., Nanobiosensors and Nanobioanalyses. Springer: 2015. 29 ACS Paragon Plus Environment
Environmental Science & Technology
528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574
Page 30 of 31
17. Shen, F.; Tan, M.; Wang, Z.; Yao, M.; Xu, Z.; Wu, Y.; Wang, J.; Guo, X.; Zhu, T., Integrating silicon nanowire field effect transistor, microfluidics and air sampling techniques for real-time monitoring biological aerosols. Environ. Sci. Technol. 2011, 45 (17), 7473-7480. 18. Camara, B.; Reymond, E.; Saint-Raymond, C.; Roth, H.; Brenier-Pinchart, M. P.; Pinel, C.; Cadranel, J.; Ferretti, G.; Pelloux, H.; Pison, C.; Camara, B.; Quetant, S.; Lebeau, B.; Thiebaut, A. B.; Saint, C. R.; Maubon, D.; Bosseray, A.; Hamidfar, R.; Pinel, C.; Pelloux, H.; Brenier-Pinchart, M. P.; Mallaret, M. R.; Plantaz, D.; Goutier, S.; Cornet, M.; Epaulard, O.; Reymond, E.; Ferretti, G., Characteristics and outcomes of chronic pulmonary aspergillosis: A retrospective analysis of a tertiary hospital registry. Clin. Respir. J. 2015, 9 (1), 65-73. 19. Pastor, F.; Guarro, J., Alternaria infections: laboratory diagnosis and relevant clinical features. Clin. Microbiol. Infect. 2008, 14 (8), 734-746. 20. Jin, J.-H.; Kim, J.; Jeon, T.; Shin, S.-K.; Sohn, J.-R.; Yi, H.; Lee, B. Y., Real-time selective monitoring of allergenic Aspergillus molds using pentameric antibody-immobilized single-walled carbon nanotube-field effect transistors. RSC Adv. 2015, 5 (20), 15728-15735. 21. Gholizadeh, A.; Shahrokhian, S.; Iraji zad, A.; Mohajerzadeh, S.; Vosoughi, M.; Darbari, S.; Koohsorkhi, J.; Mehran, M., Fabrication of sensitive glutamate biosensor based on vertically aligned CNT nanoelectrode array and investigating the effect of CNTs density on the electrode performance. Anal. Chem. 2012, 84 (14), 5932-5938. 22. Argentieri, M. C.; Pilla, D.; Vanzati, A.; Lonardi, S.; Facchetti, F.; Doglioni, C.; Parravicini, C.; Cattoretti, G., Antibodies are forever: a study using 12–26‐year‐old expired antibodies. Histopathology 2013, 63 (6), 869-876. 23. Tan, Y. H.; Liu, M.; Nolting, B.; Go, J. G.; Gervay-Hague, J.; Liu, G.-y., A nanoengineering approach for investigation and regulation of protein immobilization. ACS nano 2008, 2 (11), 2374-2384. 24. Górny, R. L.; Reponen, T.; Willeke, K.; Schmechel, D.; Robine, E.; Boissier, M.; Grinshpun, S. A., Fungal fragments as indoor air biocontaminants. Appl. Environ. Microbiol. 2002, 68 (7), 3522-3531. 25. Green, B. J.; Tovey, E. R.; Sercombe, J. K.; Blachere, F. M.; Beezhold, D. H.; Schmechel, D., Airborne fungal fragments and allergenicity. Med. Mycol. 2006, 44 (sup1), 245-255. 26. Petrikkou, E.; Rodrı́guez-Tudela, J. L.; Cuenca-Estrella, M.; Gómez, A.; Molleja, A.; Mellado, E., Inoculum standardization for antifungal susceptibility testing of filamentous fungi pathogenic for humans. J. Clin. Microbiol. 2001, 39 (4), 1345-1347. 27. Yang, C. S.; Heinsohn, P. A., Sampling and analysis of indoor microorganisms. John Wiley & Sons: 2007. 28. Zahradnik, E.; Kespohl, S.; Sander, I.; Schies, U.; Khosravie-Hohn, J.; Lorenz, W.; Engelhart, S.; Kolk, A.; Schneider, G.; Brüning, T., A new immunoassay to quantify fungal antigens from the indoor mould Aspergillus versicolor. Environ. Sci.: Processes 2013, 15 (6), 1162-1171. 29. Kim, J. P.; Lee, B. Y.; Hong, S.; Sim, S. J., Ultrasensitive carbon nanotube-based biosensors using antibody-binding fragments. Anal. Biochem. 2008, 381 (2), 193-198. 30. Vacic, A.; Criscione, J. M.; Rajan, N. K.; Stern, E.; Fahmy, T. M.; Reed, M. A., Determination of molecular configuration by Debye length modulation. J. Am. Chem. Soc. 2011, 133 (35), 13886-13889. 31. Deards, M.; Montague, A., Purification and characterisation of a major allergen of Alternaria alternata. Mol. Immunol. 1991, 28 (4), 409-415.
30 ACS Paragon Plus Environment
Page 31 of 31
575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596
Environmental Science & Technology
32. Jin, H.-E.; Zueger, C.; Chung, W.-J.; Wong, W.; Lee, B. Y.; Lee, S.-W., Selective and Sensitive Sensing of Flame Retardant Chemicals Through Phage Display Discovered Recognition Peptide. Nano Lett. 2015, 15 (11), 7697-7703. 33. Auriol, M.; Filali-Meknassi, Y.; Adams, C. D.; Tyagi, R. D., Natural and synthetic hormone removal using the horseradish peroxidase enzyme: temperature and pH effects. Water Res. 2006, 40 (15), 2847-2856. 34. Lee, B. Y.; Seo, S. M.; Lee, D. J.; Lee, M.; Lee, J.; Cheon, J.-H.; Cho, E.; Lee, H.; Chung, I.-Y.; Park, Y. J., Biosensor system-on-a-chip including CMOS-based signal processing circuits and 64 carbon nanotube-based sensors for the detection of a neurotransmitter. Lab Chip 2010, 10 (7), 894-898. 35. Seethala, R.; Zhang, L., Handbook of drug screening. CRC Press: 2009. 36. Ezzouhri, L.; Castro, E.; Moya, M.; Espinola, F.; Lairini, K., Heavy metal tolerance of filamentous fungi isolated from polluted sites in Tangier, Morocco. Afr. J. Microbiol. Res. 2009, 3 (2), 35-48. 37. Misaghi, I.; Grogan, R.; Duniway, J.; Kimble, K., Influence of environment and culture media on spore morphology of Alternaria alternata. Phytopathology 1978, 68 (1), 2934. 38. Prasad, V.; Upadhyay, R., ALTERNARIA ALTERNATA f. sp. LYCOPERSICI AND ITS TOXIN TRIGGER PRODUCTION OF H₂O₂ AND ETHYLENE IN TOMATO. J. Plant. Pathol. 2010, 103-108. 39. El-Gali, Z. I., Alternaria alternata isolated from lemons (Citrus lemon) in Libya. Eur. J. Acad. Essays 2014, 1 (9), 20-23.
31 ACS Paragon Plus Environment