High Resolution Monitoring Above and Below the Groundwater Table

Nov 13, 2017 - In addition, all ports were sampled simultaneously, with varying sampling time periods due to differences in soil moisture and therefor...
0 downloads 8 Views 2MB Size
Subscriber access provided by READING UNIV

Article

High resolution monitoring above and below the groundwater table uncovers small – scale hydrochemical gradients Niklas Gassen, Christian Griebler, Ulrike Werban, Nico Trauth, and Christine Stumpp Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b03087 • Publication Date (Web): 13 Nov 2017 Downloaded from http://pubs.acs.org on November 15, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 38

Environmental Science & Technology

1

High resolution monitoring above and below the groundwater table uncovers small –

2

scale hydrochemical gradients

3

4

Gassen, N.1; Griebler, C. 1; Werban, U.2; Trauth, N.3, Stumpp, C. 1,*)

5

1

6

for Environmental Health (GmbH), Ingolstaedter Landstr. 1, 85764 Neuherberg, Germany

7

2

8

Research – UFZ, Permoserstr. 15, 04318 Leipzig, Germany

9

3

10

Institute of Groundwater Ecology, Helmholtz Zentrum München, German Research Center

Department Monitoring and Exploration Technologies, Helmholtz Center for Environmental

Department of Hydrogeology, Helmholtz Center for Environmental Research – UFZ,

Permoserstr. 15, 04318 Leipzig, Germany

11

12 13

*) Corresponding author: [email protected]; tel. +49 89 31872084; fax: +49 89 31873361

14 15

Abstract

16 17

Hydrochemical solute concentrations in the shallow subsurface can be spatially highly

18

variable within small scales, particularly at interfaces. However, most monitoring systems fail

19

to capture these small scale variations. Within this study, we developed a high resolution

20

multi-level well (HR-MLW) with which we monitored water across the interface of the

21

unsaturated and saturated zone with a vertical resolution of 0.05-0.5 m. We installed three of

22

these 4 m deep HR-MLWs in the riparian zone of a 3rd-order river and analyzed for 1

ACS Paragon Plus Environment

Environmental Science & Technology

23

hydrochemical parameters and stable water isotopes. The results showed three distinct vertical

24

zones (unsaturated zone, upper saturated zone, lower saturated zone) within the alluvial

25

aquifer. A 2 m thick layer influenced by river water (upper saturated zone) was not captured

26

by existing monitoring wells with higher screen length. Hydrochemical data (isotopes, total

27

ions) were consistent in all HR-MLWs and showed similar variation over time emphasizing

28

the reliability of the installed monitoring system. Further, the depths zones were also reflected

29

in the NO3-N concentrations; with high spatial variabilities between the 3 wells. The zonation

30

was constant over time, with seasonal variability in the upper saturated zone due to the

31

influence of river water. This study highlights the use of high resolution monitoring for

32

identifying the spatial and temporal variability of hydrochemical parameters present in many

33

aquifer systems. Possible applications range from riparian zones, agricultural field sites to

34

contaminated site studies, wherever an improved understanding of biogeochemical turnover

35

processes is necessary. Keywords: Multi-level well, capillary fringe, groundwater, riparian

36

zone, nitrogen, heterogeneity

37

38

Introduction

39

Concentrations of nutrients and contaminants in both the unsaturated and the saturated zone of

40

the shallow subsurface are highly variable in space and time. Temporally irregular and

41

heterogeneous input pathways, e.g. due to preferential flow paths caused by sediment

42

heterogeneities

43

different residence times along various flow paths3,

44

solute concentrations. In addition, reaction rates are dependent on multiple parameters on

45

different scales or vary over time and along individual flow paths. Particularly,

46

biogeochemical transformation processes take place at small scales and only where reactants

1 2

, contributions from several sources (e.g., rainwater, river water) and 4

can lead to spatially heterogeneous

2

ACS Paragon Plus Environment

Page 2 of 38

Page 3 of 38

Environmental Science & Technology

47

and respective microorganisms meet 5. Here, interfaces between compartments are of

48

particular interest because high reaction rates have often been observed where conditions

49

change as flow paths meet

50

limitations can be overcome and reactions rates are disproportionally high 8. Such an intra-

51

compartment interface can be found between the unsaturated and the saturated zone9, 10, where

52

often carbon and oxygen rich soil water meets groundwater with a different composition.

53

These differences can lead to steep hydrochemical gradients across the interface at the

54

unsaturated and saturated zone

55

microbial activities pose a challenge when it comes to detailed understanding of

56

ecohydrological processes, monitoring approaches and modelling of natural systems. Often,

57

only integrated rates of nutrient cycling and transformation processes in catchments or sub-

58

catchments can be inferred from available monitoring systems

59

calculating overall budgets of elemental cycling, but lacks a detailed understanding of when

60

and where processes take place. By simply integrating processes over time and space, we

61

might miss important details, which may explain catchment responses to rainfall events13 and

62

which can help to enhance or use specific ecosystem functions or turnover processes (e.g.

63

nitrate removal) in catchments. A crucial step towards a higher understanding of

64

spatiotemporal processes is to increase the resolution of existing monitoring systems

65

which can be beneficial for contaminated site studies16 as well as for nitrate removal studies20.

66

Existing high resolution monitoring systems have not focused on the unsaturated – saturated

67

interface; simply because most systems target only one of both zones21, 22.

68

In order to monitor solute concentrations across the groundwater table with a high resolution,

69

a combined approach including available monitoring systems for the saturated and the

70

unsaturated zone is urgently needed. To date, multi-level sampling in the saturated zone is

6, 7

. By bringing solutes of different origin together, substrate

11

. The heterogeneous patterns of solute concentrations and

3

ACS Paragon Plus Environment

12

. This is sufficient for

5, 14-19

,

Environmental Science & Technology

71

often achieved with nested systems 23-25. However, when it is required to sample many depth,

72

nested systems are limited as each depth requires a separate piezometer tube, increasing

73

uncertainty arising from the lateral distance between the tubes

74

natural water flow by the multiple tubes. It is apparent that custom made designs are

75

necessary to get high resolution depth profiles at the centimeter scale. Few studies applied and

76

adapted an earlier proposed system27, connecting small sampling ports via steel capillaries

77

with the surface16,

78

applied cheap and easy to construct multi-level samplers in the hyporheic zone26. However,

79

all of these systems only allow sampling in the saturated zone. Water sampling in the

80

unsaturated zone is more complex. Here, water has to be actively withdrawn and samples can

81

be taken by the use of suction cup sampling

82

different depths, either vertically from the surface or slanted in different angles in order to

83

capture the vertical flow in the unsaturated zone

84

unsaturated zone is limited by the rather large size of the suction cups which are necessary to

85

extract the small amount of water available. Furthermore, installation of suction cups in

86

greater depth requires drilling holes with the same diameter as the suction cup in order to

87

avoid preferential flow along the drilling hole and to guarantee hydrologic contact between

88

the suction cup and the soil. Therefore, it takes a lot of effort to permanently install such

89

systems in vertical profiles for studying processes along flow paths.

90

Only a few systems enabling water sampling in the unsaturated and saturated zone have been

91

reported, which had maximum resolutions of 0.09 m 33, 34. An even higher resolution would be

92

necessary, though, to capture hydrochemical gradients and processes which take place at the

93

pore scale and which are limited by mass transfer processes 16; particular when it comes about

94

identifying nonlinear, dynamic ecohydrological processes at interfaces like the unsaturated -

26

and potential disturbance of

28-30

, allowing maximum sampling resolutions of 0.03 m. Other studies

31

. In most cases, suction cups are installed at

32

. Depth specific resolution in the

4

ACS Paragon Plus Environment

Page 4 of 38

Page 5 of 38

Environmental Science & Technology

95

saturated zone18. To date, multi-level wells have been mainly designed to sample water from

96

individual aquifer layers and it remains a challenge to sample water across the groundwater

97

table at high resolution.

98

Therefore, we introduce a novel sampling device and present first results from three high

99

resolution

multi-level

observation

wells

(HR-MLW),

demonstrating

small-scale

100

hydrochemical gradients across the water table at 0.05 m resolution. Our system provides

101

impressive insights into small-scale variations of solutes and their temporal response at the

102

interface of the unsaturated and saturated zone.

103

104

Material and Methods

105

High-resolution multi-level well construction and installation

106

The HR-MLW extends over 4 m and contains 23 individual sampling ports, located in 0.05 m

107

to 0.5 m intervals along the well casing (Figure 1). The highest spatial resolution of 0.05 m is

108

given in the vicinity of the average groundwater level on site, which is hereafter referred to as

109

the groundwater fluctuation zone. The lowest resolution (0.5 m) is given in the saturated zone.

110

The HR-MLW was constructed from four 1 m long, 25/32 mm inner/outer diameter (ID/OD)

111

high-density polyethylene (HDPE) tubes (Carl Hamm GmbH) with screw fittings for

112

connecting the 1 m modules. Sampling ports were placed on the outside of the HDPE tubes

113

and connected to the inside with stainless steel capillaries (Swagelok, 1 mm ID, 3 mm OD)

114

and nylon hoses (1.6 mm ID, 2.8 mm OD) for glass frits and suction cups, respectively

115

(Figure 2). Entry points of steel capillaries/nylon hoses were sealed with silicon glue in order

116

to avoid hydraulic shortcuts between the ports. All sampling ports were connected to the

117

surface through the inside of the HDPE tube. For the sampling ports in the unsaturated and the 5

ACS Paragon Plus Environment

Environmental Science & Technology

Page 6 of 38

118

fluctuation zone, custom made ceramic suction cups (UMS Munich) with a length of 25 mm,

119

a diameter of 12 mm and a mesh size of