Impact of Joule Heating and pH on Biosolids Electro-dewatering Tala Navab-Daneshmand, Raphaël Beton, Reghan J. Hill, and Dominic Frigon Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/es5048254 • Publication Date (Web): 15 Dec 2014 Downloaded from http://pubs.acs.org on December 20, 2014
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 26
Environmental Science & Technology
1
Impact of Joule Heating and pH on Biosolids
2
Electro-dewatering
3
Tala Navab-Daneshmand1, Raphaël Beton1, Reghan J. Hill2 and Dominic Frigon*, 1
4 5
1
Department of Civil Engineering and Applied Mechanics, McGill University, 817 Sherbrooke
6 7
St. West, Montreal, Quebec H3A 0C3, Canada 2
Department of Chemical Engineering, McGill University, 3610 University St., Montreal,
8
Quebec H3A 0C5, Canada
9
* Email:
[email protected], Telephone: +1-514-398-2476, Fax: +1-514-398-7361
10 11 12
ABSTRACT Electro-dewatering (ED) is a novel technology to reduce the overall costs of residual
13
biosolids processing, transport and disposal. In this study, we investigated Joule heating and pH
14
as parameters controlling the dewaterability limit, dewatering rate, and energy efficiency.
15
Temperature-controlled electrodes revealed that Joule heating enhances water removal by
16
increasing evaporation and electro-osmotic flow. High temperatures increased the dewatering
17
rate, but had little impact on the dewaterability limit and energy efficiency. Analysis of
18
horizontal layers after 15 min ED suggests electro-osmotic flow reversal, as evidenced by a
19
shifting of the point of minimum moisture content from the anode toward the cathode. This flow
20
reversal was also confirmed by the pH at the anode being below the isoelectric point, as
21
ascertained by pH titration. The important role of pH on ED was further studied by adding
22
acid/base solutions to biosolids prior to ED. An acidic pH reduced the biosolids charge while
ACS Paragon Plus Environment
1
Environmental Science & Technology
Page 2 of 26
23
simultaneously increasing the dewatering efficiency. Thus, process optimization depends on
24
tradeoffs between speed and efficiency, according to physicochemical properties of the biosolids
25
microstructure.
26 27 28
INTRODUCTION Biosolids production and its potential health risks are important concerns for
29
municipalities. High biosolids water content from mechanical dewatering (65-85% w/w) leads to
30
high transport and disposal costs.1 Additionally, the recovery of biosolids as soil amendments
31
demands US-EPA microbiological Class A or B or equivalent status.2 Electro-dewatering (ED) is
32
an attractive new technology for enhancing the sustainability of biosolids handling. By applying
33
an electric field to mechanically dewatered biosolids, ED can achieve 35% w/w water content
34
while using less than 25% of the energy required for thermal drying;3 it can also reduce bacterial
35
pathogen indicators to meet US-EPA regulations.4
36
During ED with an open-sided unit,4 two phenomena participate in the dewatering
37
process: electro-osmosis and evaporation. Electro-osmosis is the transport of water from pores
38
and interstices by viscous and/or molecular interactions. The surface charge density of colloidal
39
biosolids particles induces electro-osmotic flow when subjected to an electric field.5 This water
40
transport occurs in parallel with electrolysis, producing hydrogen ions at the anode and hydroxyl
41
ions at the cathode. The production and transport of ions inside the biosolids matrix affects the
42
composition of the biosolids cake that is sandwiched between the electrodes.4, 6 Concurrently
43
with electro-osmotic flow, Joule heating increases the temperature. High temperatures may
44
facilitate dewatering by reducing the water viscosity and enhancing evaporation.7 Ultimately, the
45
cumulative effects of electro-osmosis and evaporation determine the extent of dewatering.
ACS Paragon Plus Environment
2
Page 3 of 26
46
Environmental Science & Technology
Beyond temperature changes, ED subjects the dewatering cake to changes in pH. The
47
effects of biosolids pH and particle surface charge on biosolids dewaterability have been studied
48
in different contexts.5, 8-11 A common pH reference is the isoelectric point, which corresponds to
49
zero surface charge density; it is reported to occur at pH values between 1 and 3 for municipal
50
wastewater biosolids.5, 10, 12 At pH levels slightly above the isoelectric point, biosolids particle
51
surfaces have a low negative charge, and the biopolymer matrix is most compact.13 At pH values
52
far from the isoelectric point, high charge densities (positive charge at low pH and negative
53
charge at high pH) enhance repulsion and, hence, expand the matrix. The expanded structure
54
would present a higher resistance to flow by increasing the biosolids specific surface area.13
55
Despite these initial descriptions of temperature and pH on ED, theoretical concepts
56
linking the observed dynamics and the engineering of the process remains to be properly defined
57
for practitioners. Here, we propose three concepts. First, the dewaterability limit is the mass of
58
remaining water in a biosolids sample per mass of total solids when electro-osmotic flow stops.
59
This is the ultimate moisture content achievable by the ED process. Second, the dewatering rate
60
is the mass of water removed per dewatering time. As it relates to the overall treatment rate of
61
ED units, dewatering rate negatively correlates with the capital investment in a treatment facility.
62
Third, dewatering energy efficiency is the mass of water removed per unit of electrical energy
63
consumed. This negatively correlates with the operational costs of ED units. The main objective
64
of this study is to describe the impact of temperature and pH on the ED process in terms of the
65
defined parameters: dewaterability limit, dewatering rate, and energy efficiency.
66
To fully understand these concepts, they need to be defined with respect to the
67
classification of water contained in biosolids: free, capillary, vicinal, and hydration.14 Free water
68
is not bound to the solids matrix; capillary water is loosely bound to the matrix by mechanical
ACS Paragon Plus Environment
3
Environmental Science & Technology
Page 4 of 26
69
adsorption; vicinal water is more tightly bound to the matrix by hydrogen bonding; and, finally,
70
water of hydration is bound within the solids biopolymer matrix by relatively strong chemical
71
bonds (and can be removed only by thermal energy). The binding energy of water to the solids is
72
inversely related to water activity, which is the ratio of the vapor pressure of water in equilibrium
73
with biosolids to the saturated vapor pressure of pure water. Classical S-shaped water adsorption
74
isotherms related water activity and moisture content, and they can be interpreted according to
75
the discrete water distribution discussed above.15, 16
76
The binding strength of water to a biosolids matrix plays a significant role in
77
dewatering.17 By hindering water flow and determining the necessary energy requirement to
78
remove water, the binding strength of water to the matrix impacts the dewaterability limit,
79
dewatering rate, and energy efficiency. Furthermore, electrical conductivity is related to water
80
activity, because water activity also measures the availability of the water molecules to transport
81
ions as electrical current.18 While water distribution in biosolids has been studied in relation to
82
other dewatering processes,14-17 so far it has not been examined for ED. Therefore, ED dynamics
83
need to be defined with respect to biosolids water activity and its related adsorption isotherm.
84
This study investigated the dewaterability limit, and the dewatering rate and efficiency of
85
ED biosolids. The impact of Joule heating on the fractions of water removed by electro-osmosis
86
and evaporation was experimentally determined via a temperature controlled ED unit. Here,
87
mass and energy balances were used to compute the evaporated and remaining water during the
88
tests. Next, the effects of the initial biosolids pH and ionic strength on ED rate and efficiency
89
were evaluated by the addition of acid, base or neutral salts. Finally, because of the vertical
90
stratification in water activity and pH between the anode and the cathode, these effects were
91
analyzed by dividing the cake into four horizontal layers.
ACS Paragon Plus Environment
4
Page 5 of 26
Environmental Science & Technology
92 93 94
MATERIALS AND METHODS Biosolids. The secondary waste activated sludge biosolids were obtained from the
95
centrifugal dewatering units at a wastewater treatment plant near Montréal without a primary
96
clarifier. The cationic polymers Flo-CA475 and Flo-CA4800 were added before the dissolved air
97
floatation and centrifuge dewatering units (1-4 kg/ton-TS and 12-21 kg/ton-TS; SNF Canada
98
Ltd., Trois-Rivières, Québec, Canada). Dewatered biosolids samples were collected, brought to
99
the laboratory on ice, and then stored at 4 °C for up to 4 d. Throughout the study, total solids,
100
pH, and apparent resistivity of biosolids were in the range 14.1-18.5% w/w, 6.6-7.5, and 1000-
101
2000 Ohm/m, respectively.
102
Electro-dewatering. The laboratory ED unit was an Ovivo model CINETIK® CK-Lab
103
(Boucherville, Québec, Canada, Figure S1). In these experiments, a direct current was applied
104
with the maximum voltage and current set at 60 V and 6.5 A, respectively. The effect of high
105
temperatures on dewatering was examined using temperature controlled (i.e., cooled) electrodes
106
(see details in Navab-Daneshmand et al., 2012).4 For the layered ED tests, a 53-µm pore-size
107
Spectra Mesh™ nylon filter was used as the partitioning material (Spectrum® Laboratories Inc,
108
Rancho Dominguez, CA). This nylon mesh has been shown to have no significant impact on
109
energy consumption, water removal, and temperature.4 Voltage, current, pressure, removed
110
filtrate mass, cake thickness, electrical energy consumption, biosolids cake temperature, anode
111
temperature, and cathode temperature were measured at 2 s intervals. To study the influence of
112
the initial pH and ionic strength on ED efficiency, 4-10 mL of 0.5 M NaCl, HCl, or NaOH
113
solutions were added to the untreated biosolids samples and mixed in with a spatula. To test the
114
apparent resistivity (resistance divided by cake thickness) in each horizontal layer of the
ACS Paragon Plus Environment
5
Environmental Science & Technology
Page 6 of 26
115
dewatered cake, four layered biosolids samples were electro-dewatered for 15 min. After ED,
116
samples from the same layers in different ED tests were mixed thoroughly and electro-dewatered
117
for another 5 min.
118
Total Solids, Water Activity and Moisture Sorption Isotherms. Standard Method No.
119
2540-B was used to measure biosolids dryness.19 Moisture sorption isotherms were constructed
120
by drying 10 wet g of biosolids at 105 °C for 2 to 8 h. Biosolids were then transferred to water
121
activity plastic containers (ROTRONIC®, Switzerland). The containers were immediately sealed
122
(to avoid moisture exchange) and left on the bench until they reached room temperature (20 °C).
123
Water activity was measured using the manometric HygroLab Set 2 water activity meter
124
equipped with an AW-DIO probe (ROTRONIC®, Switzerland) according to the manufacturer’s
125
instructions. Water activity was recorded as 1 if condensation was present on the container walls
126
before the test. Final biosolids dryness was measured after the water activity measurements.
127
Water activity versus moisture content (mass of water per mass of dry solids) data from
128
these tests were analyzed using established isotherm models.16, 17, 20, 21 To identify the best
129
sorption isotherm, the logarithmic forms of various models for moisture content were fitted to
130
experimental data using non-linear optimization within the SAS® software package (PROC
131
MODEL, SAS Institute Inc., Cary, NC). Models were compared by the mean relative error
132
(MRE).17 Analyses showed that among the suggested isotherms, the Oswin (eq 1), and
133
Guggenheim-Anderson-de Boer (GAB, eq 2) models provided better fits to the data.16, 17, 20, 21
134
While the Oswin isotherm is empirical, the GAB isotherm has physico-chemical interpretations:
135 136
Oswin model: =
GAB model: = (
)(( ) )
ACS Paragon Plus Environment
(1) (2)
6
Page 7 of 26
Environmental Science & Technology
137
where aw is the water activity, Mw is the moisture content, C and n are empirical temperature
138
dependent constants, Xm is the moisture content at full monolayer coverage of adsorption
139
substratum, Cb is the ratio of the water-water to water-substratum binding energies, and k is an
140
empirical constant.16, 20, 21
141
Biosolids pH and Surface Charge Density. Biosolids pH was measured following
142
Navab-Daneshmand et al.4 using an accumet® gel-filled AgCl combination electrode (Fisher
143
Scientific, Canada). For pH titrations, 30 mL of a 0.5 M KCl solution was added to 30 g of wet
144
biosolids. Different volumes of a 0.5 M HCl or NaOH solution were added to separate beakers to
145
achieve concentrations between 0-120 mM. The total volume was adjusted to 130 mL by adding
146
DDI (distilled and then deionized) water. Suspensions were stirred on a stir plate for about 30
147
min, after which the pH was recorded.
148
Biosolids surface charge density was measured using the colloid titration technique
149
described by Morgan et al.22 Briefly, 2 wet g of biosolids were homogenized in 40 mL DDI
150
water with an Ultra-Turrax® S10N-10G disperser (IKA® Works Inc., Wilmington, NC); 0.5 mL
151
of the homogenized suspension was diluted in 49.5 mL DDI water; 2 mL of Polybrene 0.002 N
152
(Sigma-Aldrich, Milwaukee, WI) and a few drops of toluidine blue indicator were added. The
153
mixture was then titrated against PVSK (Sigma-Aldrich, Milwaukee, WI). The mixture pH was
154
manipulated by adding 0.5 M NaOH or HCl to the mixture before adding Polybrene.
155
Mass and Energy Balances. Considering the biosolids dewatering cake as the control
156
volume, and assuming that no solid leaves the control volume by filtration, the water mass
157
balance is:
158
−
−
=
(3)
ACS Paragon Plus Environment
7
Environmental Science & Technology
Page 8 of 26
159
where mF is the mass of filtered water, mV is the mass of vapor, mW is the mass of remaining
160
water in the biosolids, and t is the dewatering time. Similarly, the energy balance is:
161
−
() −
() +
!
+
"
= # $ %$
&
+ #' %
&
+
( ()
(4)
162
where CpS and CpL are heat capacities at constant pressure for solids and liquid water [J/(kg K)];
163
CpS was considered 900 J/(kg K) at 20 ºC. HL(T) and HV(T) are the enthalpies of liquid and vapor
164
water [J/kg] at temperature T [K] evaluated using constant heat capacities for liquid and vapor
165
water, respectively (i.e., CpL and CpV). UL(T) is the internal energy of liquid water [J/kg] at
166
biosolids temperature T. Qe is the electrical power [J/s], and Qh is the total heat loss (to the air,
167
anode and cathode, eq 5) [J/s].
168
Qh = βh (Qhair + Qhanode + Qhcathode), with each term in the form Qh* = A*h*( Tcake− T*) (5)
169
where the asterisk (*) identifies either air, anode or cathode, A is the interfacial cross-sectional
170
area between the cake and the heat sink of interest [m2], and h is the heat transfer coefficient (h =
171
10, 19, and 16 J/(m2 K s) for air, titanium anode, and stainless steel cathode).23 Note that for the
172
cooled tests, Qhanode and Qhcathode also account for heat losses due to the flow of ice-cold water in
173
the electrodes. To account for these losses, the constant )" was adopted as a fitting parameter to
174
ensure that the calculated value for the mass of remaining water in the biosolids (mW) at the end
175
of each test equaled the measured mass of remaining water in the cake.
176
Protonation/Deprotonation Equilibria. An analytical model was fitted to the
177
experimental data using chemical reactions for acid and base dissociation. The fitting was
178
performed to determine the apparent acid (Ka) and base (Kb) dissociation constants for the
179
surface functional groups. It was assumed that the weak acid/base contributions in the ionic
180
solutions were only from the surface functional groups, denoted as aH and bOH. Strong acid and
181
strong base (AH and BOH, respectively) were assumed both on surfaces and added to the
ACS Paragon Plus Environment
8
Page 9 of 26
Environmental Science & Technology
182
solution during titration. The model is based on the following solution electroneutrality (eq 6)
183
and water and acid/base equilibrium conditions (eqs 7-9): *+ , + *- , + *. , = */ , + *0 , + * ,
184
(6)
185
[H+][OH−] = 10−14
(7)
186
*+ , =
(8)
*/ , =
187
188
*1 ,
21345 67
*81 , 213(29345) 6
(9)
where [a0] = [aH] + [a−] and [b0] = [bOH] + [b+]. Combining eqs 6-9 furnishes eq 10:
189
190
191
:
*1 ,
21345 67,1
+
*2 ,
21345 67,2
+ *- ,
?@A!
L
+ B10 (E FG) + *- ,HI>!J>= =
*81 , 213(29345) 6,1
+ *0 ,M
=>?@A!
+ N10 FG + *0 ,OI>!J>=
(10)
192
where [a0] = [aH] + [a−], [b0] = [bOH] + [b+], and the subscripts refer to the concentrations in
193
the aqueous solution or on solid surfaces. Eq 10 was solved numerically for Ka and Kb by fitting
194
to the pH titration data. The pH time series from a base titration were fitted with the following
195
exponential relaxation:
196
P = PQ + (PQ − PR )S
U T
(11)
197
where pH∞ is the final stabilized pH calculated from the empirical model in eq 10, pH0 is the
198
initial pH after NaOH addition, t is time [min], and τ is the exponential-relaxation time constant
199
[min]. Finally, particle surface charge density (V@ ; Coulomb/g-TS) and Donnan potential (WX ; V)
200
were calculated using eqs 12 and 13:
ACS Paragon Plus Environment
9
Environmental Science & Technology
201
202
V@ = N*- , − *0 ,O=>?@A! − L WX =
*1 ,
21345 67,1
−
*2 ,
21345 67,2
+
Page 10 of 26
*81 , 213(29345) 6,1
N*Y3 , *Z[ , *Y2 ,*Y\ ,O]^_`7ab B R345 R3(29345) *Y3 , *Z[ ,H N*Y3 ,*Z[ ,*Y2 ,*Y\ ,O]^_`7ab BR345 R3(29345) *Y3 , *Z[ ,H
M
=>?@A!
7c^bd^]
7c^bd^]
(12)
(13)
203
where {[A−]-[B+]}surface is a constant used to adjust the correspondence between the pH and
204
colloidal titration data; it was acquired by fitting colloid titration data and the calculated
205
coefficients from eq 10.
206 207 208
RESULTS AND DISCUSSION Impact of Temperature. During non-cooled (i.e., normal) ED operation, the temperature
209
of the dewatering cake rapidly increased to 95.7 ± 1.9 °C (± standard deviation) after 6 min
210
(Figure 1a). Energy consumption and water removal were linear with time until a water removal
211
plateau was reached after approximately 10 min (Figure 1a). With the cooled electrodes, the
212
temperature remained below 47 °C throughout the 15 min tests (Figure 1b). Comparing the two
213
systems, the test with the non-cooled electrodes consumed more electrical energy than the one
214
with cooled electrodes (45.3 ± 2.4 W h and 32.0 ± 0.7 W h, respectively, Figures 1a and b). This
215
difference corresponds to the non-cooled system removing more water (71.2 ± 1.1% vs. 49.6 ±
216
2.2% in non-cooled and cooled ED, respectively, Figure 2).
217
The ED temporal dynamics were analyzed using the mass and energy balance equations
218
(eqs 3 and 4) to calculate the evaporated and remaining fractions of water during 15-min ED
219
(Figures 1d and e). The remaining and evaporated water are not displayed for the 60-min cooled
220
experiments (Figure 1f) because )" was not constant with time. In the non-cooled system, )"
221
(1.3 ± 0.3) was not significantly different from 1.0 and the differences are likely due to the errors
ACS Paragon Plus Environment
10
Page 11 of 26
Environmental Science & Technology
222
in measurements and the specific h coefficients considered for the heat sinks. The high )" value
223
for the cooled system accounts for the heat loss to the flow of ice-cold water that is not
224
considered in eq 4.
225
226 227
Figure 1. (a) and (b) Consumed energy, biosolids temperature, and apparent resistivity;
228
(d) and (e) remaining water, filtered water and evaporated water, for the non-cooled (left) and
229
cooled (middle) electro-dewatering systems with 15 min dewatering time. (c) Consumed energy,
230
biosolids temperature, and apparent resistivity; and (f) filtered water, for the non-cooled electro-
231
dewatering system with 60 min dewatering time. Values are the average from three replicates.
232
The standard errors for the data were below 12%, except for the evaporated water in the non-
233
cooled system where it reached 54% over the period 0-10 min. Non-cooled (a and d) and 15-min
234
cooled (b and e) experiments were performed one year apart from the 60-min cooled (c and f)
235
experiments. )" were 1.3 ± 0.3 for non-cooled (d), and 8.5 ± 0.9 for 15-min cooled ED (e).
236
ACS Paragon Plus Environment
11
Environmental Science & Technology
Page 12 of 26
237
In the non-cooled system, electro-osmotic dewatering and evaporation began after 1 min,
238
increased linearly, and stopped after 10 min and 8 min, respectively (Figure 1d). From the initial
239
biosolids water content in the non-cooled system, 50.1 ± 0.6% was removed by electro-osmosis
240
and 21.1 ± 0.9% by evaporation (Figure 2a). In the cooled ED system, however, electro-osmosis
241
was slower, never reached a plateau during the 15-min cycle, and removed 36.6 ± 1.3% moisture
242
as filtrate (Figures 1e and 2a). Furthermore, evaporation was not detected until 8 min, and
243
ultimately accounted for 13.0 ± 1.8% of the total moisture removed (Figures 1e and 2a). Note
244
that this evaporation may include artifacts due to water retained by capillarity in the filtration
245
mesh. Even with these uncertainties, higher temperatures due to Joule heating seem to enhance
246
water removal by increasing the evaporation and electro-osmotic flow rates. When cooled ED
247
was tested over a 60-min period, a dewatering plateau was observed after about 50 min (Figure
248
1f). The intermittent water flow in the electrodes during these experiments control the
249
temperature around 20 °C and, hence, caused the observed oscillating temperature and resistivity
250
profiles.
251
252 253 254
Figure 2. (a) Water fractions in biosolids after 15 min non-cooled and cooled electrodewatering; and (b) dewaterability limit after reaching a plateau after 15 min and 60 min in non-
ACS Paragon Plus Environment
12
Page 13 of 26
Environmental Science & Technology
255
cooled and cooled electro-dewatering, and dewatering rate and efficiency after 10 min of non-
256
cooled and cooled electro-dewatering. Bars represent the standard error from three replicates.
257 258
The impact of temperature on ED performance can be analyzed in terms of the three
259
performance parameters defined earlier. First, the dewaterability limits after reaching a water
260
filtration plateau were 1.28 ± 0.02 and 1.64 ± 0.01 g-remaining water/g-TS for the non-cooled
261
(15 min) and cooled (60 min) ED systems, respectively (Figure 2b). This suggests that higher
262
temperatures did not impact the dewaterability limit once sufficient dewatering time has elapsed
263
under each condition. Second, the dewatering rate was significantly higher during the non-cooled
264
ED compared to the cooled system (9.15 ± 0.04 g/min vs. 4.85 ± 0.06 g/min, Figure 2b). Finally,
265
the dewatering efficiencies were not significantly affected by different temperatures (Figure 2b).
266
Note that dewatering rates and energy efficiencies were calculated at 10 min. The 10 min
267
reference time was chosen because it is the practical full-scale dewatering time recommended for
268
this unit (Ovivo, Boucherville, Québec, Canada).
269
Cake Physicochemical Gradients. Since vertical gradients in different physicochemical
270
parameters have been previously shown to form in the dewatering cake,4 their relationship to the
271
dewaterability limit was further investigated. Biosolids samples were divided into four horizontal
272
layers and then electro-dewatered using the non-cooled system. Just before reaching the water
273
removal plateau at 10 min (Figure 1d), Layer 1 (the layer closest to the anode) was the driest
274
with 0.508 ± 0.018 g-water/g-TS (i.e., 66.2 ± 0.9% w/w total solids, Figure 3a). After dewatering
275
for 15 min, however, Layer 2 became the driest with 0.622 ± 0.376 g-water/g-TS (i.e., 65.3 ±
276
15.3% w/w total solids). To study the apparent resistivities, samples from each layer of 15 min
277
ED cake were tested in the ED unit. Although no further water was removed during these tests
ACS Paragon Plus Environment
13
Environmental Science & Technology
Page 14 of 26
278
(data not shown), the apparent resistivity was measured and reported (Figure 3c). The apparent
279
resistivity in the top layers (Layers 1 and 2) was 3-4 times higher (Figure 3c) compared to Layers
280
3 and 4. Thus, the dewaterability limit may be due to the low moisture and high resistivity in the
281
layers closest to the anode.
282
Impact of pH on Dewatering Rate and Efficiency. The changes in pH are expected to
283
affect the biosolids surface charge and, hence, ED dynamics. To study the impact of biosolids pH
284
on the dewatering rate and efficiency, HCl and NaOH were added to biosolids samples to adjust
285
the initial pH (Figure 4a). The ionic strength was also controlled by the addition of NaCl (Figure
286
4b). Departures from neutrality (i.e., increase or decrease of initial pH) reduced the dewatering
287
rate (Figure 4d). Comparing the no-additive neutral biosolids with the NaCl-added samples, the
288
main parameter that affects the dewatering rate is the ionic strength (decreasing with increasing
289
ionic strength). However, biosolids with lower initial pH demonstrated higher dewatering rates
290
compared to biosolids with higher initial pH values. Conversely, the dewatering efficiencies
291
were mainly affected by the initial pH (Figure 4e). Biosolids with lower initial pH showed higher
292
dewatering efficiencies than those with higher initial pH, an effect also observed by others.5, 9
293
ACS Paragon Plus Environment
14
Page 15 of 26
Environmental Science & Technology
294 295
Figure 3. (a) Moisture content, and (b) pH after different electro-dewatering cycles in
296
four horizontal layers of biosolids. (c) Apparent resistivity of layers 1, 2, 3, and 4 after 15 min
297
electro-dewatering, measured by averaging the apparent resistivity of each layer after electro-
298
dewatering for another 5 min. In panel (a), bars represent the range of two replicates for the 8, 9
299
and 10 min electro-dewatering cycles, and the range of four replicates for the 15 min electro-
300
dewatering cycle. In panel (b), bars represent the standard error from three replicates (pH data
301
were redrawn with permission from Navab-Daneshmand et al.).4
ACS Paragon Plus Environment
15
Environmental Science & Technology
Page 16 of 26
302 303
Figure 4. (a) Initial and final pH, (b) added ionic strength, (c) final moisture content, (d)
304
dewatering rate, and (e) dewatering efficiency for biosolids without and with added NaCl, HCl or
305
NaOH after 15 min electro-dewatering.
ACS Paragon Plus Environment
16
Page 17 of 26
Environmental Science & Technology
306 307
Figure 5. Biosolids (a) pH titration, (b) surface charge density by colloid titration, (c) and
308
Donnan potential. In panels (a) and (b), pH was adjusted by the addition of 0.5 M HCl or NaOH.
309
For colloid titration, the measured surface charge densities were divided by a factor of 23.7 to fit
310
the calculated data. The Donnan potential was calculated based on HCl and NaOH solutions
311
added to biosolids during pH titration for two different KCl concentrations (0.3 and 0.5 M).
312 313
The impact of biosolids charge properties affecting dewatering rates and efficiencies at
314
different pH were characterized by pH and charged-colloid titration (Figure 5). When biosolids
ACS Paragon Plus Environment
17
Environmental Science & Technology
Page 18 of 26
315
were titrated with HCl, the pH stabilized quickly, producing a robust titration curve (Figure 5a).
316
However, when NaOH was added, the pH did not stabilize within 6 h testing (Figure S2a). We
317
therefore used the HCl titration data to model the biosolids pH titration and estimate the surface
318
charge densities using eqs 10 and 12 (Table 1). The resulting titration model was used to
319
estimate the stable pH (PQ ) when NaOH was added, and to calculate a pH relaxation-time
320
constant (τ) for each test via eq 11 (Figure S2b). These relaxation-time constants increased
321
linearly with pH (Figure S2b), and may be valuable for future mathematical modeling of the
322
dewatering cycle. An isoelectric pH of 4.05 was measured by colloid titration and eq 12 (Table
323
1). Here, the net charge densities measured by colloid titration were approximately 24 times
324
higher than those obtained by the pH titration method. This discrepancy has been explained by
325
the non-stoichiometric polymer complex precipitation during colloid titration.24
326 327
Table 1. Model fit coefficients for eqs 10 and 12. Analytical model coefficients Equation 10 a0 Ka,0 a1 Ka,1 b0 Kb,0 Equation 8 {[A−]-[B+]}surface
Experimental data calculated values pH titration (Figure 5a) 5.37×10−2 mol/L 2.46×10−3 4.65×10−2 mol/L 1.23×10−5 1.03×10−1 mol/L 5.21×10−7 Colloid titration (Figure 6b) −4.50×10−2 mol/L
328 329
ACS Paragon Plus Environment
18
Page 19 of 26
330
Environmental Science & Technology
The dewatering rate and efficiency can now be explained with respect to the pH
331
dependency of measured charge densities. The effective attraction between the anode and
332
biosolids increases with the biosolids charge. This charge can be interpreted in terms of a
333
Donnan potential, which responds to the pH and ionic strength (eq 13 and Figure 5c). It provides
334
a good explanation for the variations in dewatering rates, since small additions of salt (i.e.,
335
increase of ionic strength) reduced the dewatering rate (Figures 4b and d) due to compression of
336
the diffuse layers of biosolids counter charge.
337
Dewaterability Limit: pH and Water activity. Dewatering reached a plateau after 10
338
min ED (Figure 1d), possibly due to changes in pH reversing electro-osmotic flow.25 Based on
339
the pH-dependent charge density, biosolids became positively charged when pH < 4 (Layer 1,
340
Figures 3b and 5b), thereby reversing the electro-osmosis driving force close to the anode. This
341
is also evident from the moisture content in Layer 1, increasing between 10 and 15 min ED,
342
while Layer 2 continued to dewater (Figure 3a).
343
Furthermore, the layers closer to the anode (i.e., Layers 1 and 2) measured 3-4 times
344
higher apparent resistivity (Figure 3c), indicating a lower capacity for Layer 1 and 2 to conduct
345
electrical current after 15 min ED. Since electrical conductivity is related to water activity,18 we
346
measured the water adsorption isotherm (Figure 6).16, 17, 20, 21 While the Oswin and GAB models
347
fitted the data satisfactorily, as observed by others,17, 20 the GAB model provided a better fit to
348
the data (Figure 6 and Table 2). Comparing the dryness of the different layers to the isotherm
349
suggests that the dewatering plateau occurs when the water activity falls below 0.95,
350
corresponding to moisture contents less than 0.82 g-water/g-TS (i.e., < 55% w/w total solids,
351
Figure 6). Under these conditions, capillary and free water have been removed and the remaining
352
water is strongly associated with the biosolids (Figure 6).15 After reaching the dewatering plateau
ACS Paragon Plus Environment
19
Environmental Science & Technology
Page 20 of 26
353
(Figure 1d), the moisture content in Layer 1 did not change, whereas the moisture content in
354
Layer 2 fell below 0.11 g-water/g-TS, suggesting that it became electrically insulating and,
355
therefore, unable to sustain continued ED. This is consistent with a previous study that showed a
356
direct relationship between water activity and conductivity, where matrices with water activities
357
below 0.95 were nonconductive.18
358
359 360
Figure 6. The moisture sorption isotherm in thermally dried biosolids samples, and in the
361
four horizontal layers of electro-dewatered biosolids cake, after 8, 9, 10 and 15 min cycles. Lines
362
are the best fits for the Oswin and GAB isotherms. Numbers next to symbols for 10 and 15 min
363
ED cycles represent the horizontal position of the cake layer, with 1 being the closest to the
364
anode and 4 being the closest to the cathode (as shown in Figure 3). The values for the electro-
365
dewatered samples are averages of two experiments with the range of replicates below 1.4% and
366
15.7% for water activity and moisture content, respectively. Interpretations of water fractions are
367
according to Vaxelaire et al.16
ACS Paragon Plus Environment
20
Page 21 of 26
Environmental Science & Technology
368 369 370
Table 2. Sorption isotherms model fit coefficients and error criteria (eqs 1 and 2 solved with
371
experimental data in Figure 6) Coefficients C N Xm Cb K MREa a Mean relative error
Oswin model 0.076 0.837
0.579
GAB model
0.041 17.031 1 0.573
372 373 374
In summary, this study shows that Joule heating during ED enhances water removal from
375
biosolids by evaporation and electro-osmotic flow mechanisms. While high temperatures
376
significantly increase the dewatering rate, they do not affect the dewaterability limit and
377
dewatering efficiency. The spatial and temporal evolution of the cake, as revealed by moisture,
378
resistivity, and pH profiles, suggests a localized reversal of the electro-osmosis driving force and
379
an increase in electrical resistance. The resulting flow reversal reflects a pH-induced change in
380
the biosolids charge due to hydrogen-ion production at the anode. Thus, at long times, the cake
381
becomes driest within, rather than at the anode, i.e., the driest layer migrates from the anode
382
toward the cathode. These dynamics are accompanied by an increase in electrical resistance, due
383
to lower water activity, which further increase resistance to electro-osmotic flow. ED with
384
various initial pH values showed that an initially acidic pH increases dewatering efficiency. This
385
is because the matrix adopts a low negative charge that reduces the hydrodynamic resistance to
ACS Paragon Plus Environment
21
Environmental Science & Technology
Page 22 of 26
386
electro-osmotic flow. Note that pH values far from the isoelectric point decrease the dewatering
387
efficiency, because the stronger mutual particle repulsion seems to increase hydrodynamic
388
resistance. These inferences might be explained by an increase in the specific surface area of the
389
matrix that accompanies an increase in the biosolids surface charge. Finally, increasing the ionic
390
strength at constant pH decreases the dewatering rate. This can be explained by a compression of
391
the diffuse layers of the biosolids counter charge; and is evident, in part, by the effect of the ionic
392
strength on Donnan potential, which we ascertained from a pH titration model. These
393
observations and the accompanying titration data will assist the development of a mathematical
394
model that accurately captures the observed spatial and temporal dynamics.
395 396 397
ACKNOWLEDGEMENTS The Natural Sciences and Engineering Research Council of Canada’s Collaborative
398
Research and Development program and Ovivo provided funding for this study. The authors
399
thank Frederic Biton (Ovivo), Bruno Desmarais (Ovivo), Alain Silverwood (Ovivo), Céline
400
Gagnon (Aquatech), and Gilbert Samson (Régie d’Assainissement des Eaux du Bassin LaPrairie)
401
for their technical support and useful comments.
402 403 404
SUPPORTING INFORMATION AVAILABLE This information is available free of charge via the Internet at http://pubs.acs.org/.
405 406
REFERENCES
407
(1) Tuan, P.A.; Jurate, V.; Mika, S. Electro-dewatering of sludge under pressure and non-
408
pressure conditions. Environ. Technol. 2008, 29 (10), 1075-1084.
ACS Paragon Plus Environment
22
Page 23 of 26
Environmental Science & Technology
409
(2) US-EPA Environmental Regulations and Technology: Control of Pathogens and Vector
410
Attraction in Sewage Sludge; 40 CFR Part 503; United States Environmental Protection Agency:
411
Cincinnati, OH, USA, 2003.
412
(3) Mahmoud, A.; Olivier, J.; Vaxelaire, J.; Hoadley, A.F.A. Electro-dewatering of wastewater
413
sludge: influence of the operating conditions and their interactions effects. Water Res. 2011, 45
414
(9), 2795-2810.
415
(4) Navab-Daneshmand, T.; Beton, R.; Hill, R.J.; Gehr, R.; Frigon, D. Inactivation mechanisms
416
of bacterial pathogen indicators during electro-dewatering of activated sludge biosolids. Water
417
Research 2012, 46 (13), 3999-4008.
418
(5) Citeau, M.; Larue, O.; Vorobiev, E. Influence of salt, pH and polyelectrolyte on the pressure
419
electro-dewatering of sewage sludge. Water Res. 2011, 45 (6), 2167-2180.
420
(6) Acar, Y.B.; Gale, R.J.; Alshawabkeh, A.N.; Marks, R.E.; Puppala, S.; Bricka, M.; Parker, R.
421
Electrokinetic remediation: basics and technology status. J. Hazard. Mater. 1995, 40 (2), 117-
422
137.
423
(7) Barton, W.A.; Miller, S.A.; Veal, C.J. The electrodewatering of sewage sludges. Drying
424
Technol. 1999, 17 (3), 498 - 522.
425
(8) Iwata, M.; Tanaka, T.; Jami, M.S. Application of electroosmosis for sludge dewatering - a
426
review. Drying Technol. 2013, 31 (2), 170-184.
427
(9) Raynaud, M.; Vaxelaire, J.; Olivier, J.; Dieudé-Fauvel, E.; Baudez, J.C. Compression
428
dewatering of municipal activated sludge: effects of salt and pH. Water Res. 2012, 46 (14), 4448-
429
4456.
ACS Paragon Plus Environment
23
Environmental Science & Technology
Page 24 of 26
430
(10) Saveyn, H.; Pauwels, G.; Timmerman, R.; Van der Meeren, P. Effect of polyelectrolyte
431
conditioning on the enhanced dewatering of activated sludge by application of an electric field
432
during the expression phase. Water Res. 2005, 39 (13), 3012-3020.
433
(11) Tixier, N.; Guibaud, G.; Baudu, M. Effect of pH and ionic environment changes on
434
interparticle interactions affecting activated sludge flocs: a rheological approach. Environ.
435
Technol. 2003, 24 (8), 971-978.
436
(12) Forster, C.F. Sludge surfaces and their relation to the rheology of sewage sludge
437
suspensions. J. Chem. Technol. Biotechnol. 1982, 32 (8), 799-807.
438
(13) Sanin, F.D. Effect of solution physical chemistry on the rheological properties of activated
439
sludge. Water SA. 2002, 28 (2), 207-211.
440
(14) Vesilind, P.A. The role of water in sludge dewatering. Water Environ. Res. 1994, 66 (1), 4-
441
11.
442
(15) Vaxelaire, J.; Cézac, P. Moisture distribution in activated sludges: a review. Water Res.
443
2004, 38 (9), 2214-2229.
444
(16) Vaxelaire, J.; Mousques, P.; Bongiovanni, J.M.; Puiggali, J.R. Desorption isotherms of
445
domestic activated sludge. Environ. Technol. 2000, 21 (3), 327-335.
446
(17) Vaxelaire, J. Moisture sorption characteristics of waste activated sludge. J. Chem. Technol.
447
Biotechnol. 2001, 76 (4), 377-382.
448
(18) Majima, H.; Peters, E.; Awakura, Y.; Park, S.; Aoki, M. Electrical conductivity of acidic
449
chloride solutions. Metall. Trans. B 1988, 19 (1), 53-58.
450
(19) APHA; AWWA; WEF Standard Methods for Examination of Water and Wastewater; 22nd
451
ed.; American Public Health Association: Washington, DC, USA, 2012.
ACS Paragon Plus Environment
24
Page 25 of 26
Environmental Science & Technology
452
(20) Andrade, R.D.P.; Roberto, L.M.; Pérez, C.E.C. Models of sorption isotherms for food: uses
453
and limitations. Vitae 2011, 18 (3), 325-334.
454
(21) Timmermann, E.O.; Chirife, J.; Iglesias, H.A. Water sorption isotherms of foods and
455
foodstuffs: BET or GAB parameters? J. Food Eng. 2001, 48 (1), 19-31.
456
(22) Morgan, J.W.; Forster, C.F.; Evison, L. A comparative study of the nature of biopolymers
457
extracted from anaerobic and activated sludges. Water Res. 1990, 24 (6), 743-750.
458
(23) ToolBox, T.E. http://www.engineeringtoolbox.com
459
(24) Mikkelsen, L.H. Applications and limitations of the colloid titration method for measuring
460
activated sludge surface charges. Water Res. 2003, 37 (10), 2458-2466.
461
(25) Yang, Z.; Lee, D.J. Structure evolution of wastewater sludge during electroosmotic
462
dewatering. Drying Technol. 2010, 28 (7), 890-900.
463
ACS Paragon Plus Environment
25
Environmental Science & Technology
ACS Paragon Plus Environment
Page 26 of 26