In Situ Measurements of Labile Al and Mn in Acid Mine Drainage

This study evaluates the use of DGT on labile Al and Mn in AMD (pH 3.1−4.2). DGT measurements were performed both in standard solutions in the labor...
0 downloads 0 Views 80KB Size
Anal. Chem. 2007, 79, 6419-6423

In Situ Measurements of Labile Al and Mn in Acid Mine Drainage Using Diffusive Gradients in Thin Films Jens Søndergaard*

Institute of Geography and Geology, University of Copenhagen, Øster Voldgade 10, DK-1350 Copenhagen K, Denmark

The technique of diffusive gradients in thin films (DGT) can be used for in situ measurements of labile metal species in water, but the application for this method on acid mine drainage (AMD) is complicated due to reduced sampler adsorption of metals at low pH. This study evaluates the use of DGT on labile Al and Mn in AMD (pH 3.1-4.2). DGT measurements were performed both in standard solutions in the laboratory and in situ in the field. Laboratory results show that DGT can be used in water with pH as low as 3.0 for Al and 4.0 for Mn without correcting for reduced adsorption. Below pH 4.0, the adsorption of Mn showed a linearly decrease with pH to ∼55% at pH 3.0. Taking this correction into account revealed that 84-100% of the total dissolved Al and Mn measured in the field was DGT-labile. Measurements using DGT agreed well with predictions using the speciation program WHAM VI. This study shows that the use of DGT can be extended below the previously reported pH working range for Al, and for Mn using a simple linear correction with respect to pH, and demonstrates that the technique can be applied for monitoring time-integrated labile metal concentrations at AMD sites. Metals exist in a variety of inorganic and organic species in aquatic systems, ranging from simple hydrated molecules to large organic complexes. The availability of these metals to living organisms, and thus potential toxicity, depends on the nature of these species and methods to discriminate between them are needed to assess the environmental impact.1-3 A promising analytical speciation method is diffusive gradients in thin films (DGT).4 DGT is based on the principle of diffusion of hydrated metal ions and complexes through a hydrogel layer of known thickness and pore size, followed by an immobilization of the metal ions on a chelating resin. The resin is subsequently removed, and the metals are extracted by acid and detected. Only metal species that are mobile (capable of diffusing sufficiently quickly through the hydrogel layer) and labile (dissociate within the time window of a few minutes) contribute to the measured mass. Different options of hydrogels are available for discriminat* Phone: +45 35324164. Fax: +45 35322501. E-mail: [email protected]. (1) Florence, T. M.; Morrison, G. M.; Stauber, J. L. Sci. Total Environ. 1992, 125, 1-13. (2) Tercier, M.-L.; Buffle, J. Electroanalysis 1993, 5, 187-200. (3) Allen, H. E.; Hansen, D. J. Water Environ. Res. 1996, 68, 42-54. (4) Zhang, H.; Davison, W. Anal. Chem. 1995, 67, 3391-3400. 10.1021/ac0708442 CCC: $37.00 Published on Web 07/10/2007

© 2007 American Chemical Society

ing between complexes.4 Using the conventional APA hydrogel, as in this study, allows free hydrated metal cations, most inorganic complexes, and small organic complexes to be detected.4 As the resin only adsorbs free and kinetically labile metal ions, this approach therefore provides a better measure of biologically available metals than do dissolved or total metal concentrations.4 A great advantage of the DGT device is that it can be deployed in situ as sampling and storage have been shown to induce changes in the nature and distribution of metal species in the water.5 Furthermore, as the sampler provides a time-integrated measure of the labile metal concentrations in the water and can be deployed in time spans ranging from a few hours to several months,6,7 it may consequently give a better measure in waters with great temporal variability in element composition than conventional water sampling with subsequent laboratory analysis. A limitation to the DGT technique is the reduced performance of the chelating Chelex-resin at both high and low pH ranges, and for most metals it functions best in the pH range of 5-10.6 The lower pH limit for the use of DGT is determined by the competition between metals and hydrogen ions for the binding agent. Cd has been found to bind relatively weakly and can only be measured down to pH 5, while Cu binds very strongly and can be measured down to pH 2.6 Other metals usually lie between these extremes.6 This pH working range is a challenge for the application of DGT on acid mine drainage (for monitoring metals other than Cu) where the pH is typically between 2 and 5. DGT has previously been used for Al speciation measurements in solutions as low as pH 3.5,8-10 but DGT performance for Al has only been documented down to pH 4.0.10 DGT measurements of Mn have previously been reported to work down to pH 3.5.6 In this study, the DGT technique was applied on acid mine drainage (AMD) from a coal mine waste rock pile in Svalbard (78°N), where high Al and Mn concentrations have previously been suggested to be the main cause of plant degradation in the (5) Laxen, D. P. H.; Chandler, I. M. Anal. Chem. 1982, 54, 1350. (6) Gimpel, J.; Zhang, H.; Hutchinson, W.; Davison, W. Anal. Chim. Acta 2001, 448, 93-103. (7) Murdoch, C.; Kelly, M.; Chang, L.-Y.; Davison, W.; Zhang, H. Environ. Sci. Technol. 2001, 35, 4530-4535. (8) Jansen, B.; Nierop, K. G. J.; Verstraten, J. M. Anal. Chim. Acta 2002, 454, 259-270. (9) Jansen, B.; Mulder, J.; Verstraten, J. M. Anal. Chim. Acta 2003, 498, 105117. (10) Jansen, B.; Kotte, M. C.; Wijk, A. J. van; Verstraten, J. M. Sci. Total Environ. 2001, 277, 45-55.

Analytical Chemistry, Vol. 79, No. 16, August 15, 2007 6419

area.11 The study may also have broader interest as Al and Mn are reported to be toxic in many ecosystems where low pH levels are observed;12 Al is known to form strong organometallic complexes that may significantly reduce toxicity,13 and alternative Al speciation techniques such as equilibrium dialysis, Clarke’s quickly reacting Al method, and the Donnan membrane technique are known to be prone to inaccuracy and are time-consuming.14-16 It has to be noted, however, that these alternative techniques are based on different separation principles and therefore detect other fractions of Al in solution than DGT. The aim of the study was to (1) investigate the pH-dependence of adsorption of Al and Mn on the resin layer of the DGT in the pH range from 2.5 to 4.5 under controlled conditions in the laboratory; (2) perform in situ measurements with DGT in the acid mine drainage to assess the labile concentrations of Al and Mn, applying possible corrections found in the laboratory experiment; and (3) compare observed labile concentrations with predictions using the speciation program WHAM VI.17 EXPERIMENTAL SECTION DGT. Standard piston-type DGT samplers for metals obtained from DGT Research Ltd. were used throughout this study. The samplers contained a Chelex 100 chelating resin in the Na form, covered with an APA hydrogel,18 and a 0.45-µm membrane filter as described previously.4 Using Fick’s first law of diffusion and known diffusion coefficients of metal ions within the diffusive hydrogel, concentrations of metal in the water can be determined from the amount of metal captured on the resin according to eq 1.4 C is the concentration of metal in solution, M is the mass of

C ) M∆g/DAt

(1)

metal captured on the resin, ∆g is the thickness of hydrogel and membrane filter, D is the diffusion coefficient of the metal ion within the gel, A is the exposure area, and t is the deployment time. The mass of metal on the resin is calculated from the metal concentration in the elution sample (Ce), the volume of the elution fluid (VHNO3) and the chelating resin (Vgel), and an elution factor (fe) needed to compensate for incomplete metal removal from the resin according to eq 2.4 Hydrogel thicknesses in the supplied

M)

Ce(VHNO3 + Vgel) fe

(2)

DGT samplers were 0.80 mm and the membrane thickness and (11) Elberling, B.; Søndergaard, J.; Jensen, L. A.; Schmidt, L. B.; Hansen, B. U.; Asmund, G.; Balic-Zunic, T.; Hollesen, J.; Hanson, S.; Jansson, P-E.; Friborg, T. Environ. Sci. Technol. 2007, 41, 2407-2413. (12) Adriano, D. C. Trace Elements in Terrestrial Environments. Biogeochemistry, Bioavailablility and Risk of Metals; Springer-Verlag: New York, 2001. (13) Ma, F. J.; Ryan, P. R.; Delhaize, E. Trends Plant Sci. 2001, 6, 273-278. (14) Glaus, M. A.; Hummel, W.; Van Loon, L. R. Appl. Geochem. 2000, 15, 953972. (15) Van Hees, P.; Tipping, E.; Lundstro ¨m, U. S. Sci. Total Environ. 2001, 278, 215-229. (16) Temminghoff, E. J. M.; Plette, A. C. C.; Van Eck, R.; Van Riemsdijk, W. H. Anal. Chim. Acta 2000, 417, 149-157. (17) Tipping, E. Aquat. Geochem. 1998, 4, 3-48. (18) Zhang, H.; Davison, W. Anal. Chim. Acta 1999, 398, 329-340.

6420

Analytical Chemistry, Vol. 79, No. 16, August 15, 2007

exposed area for diffusion 0.13 mm and 3.14 cm2, respectively. The diffusion coefficients provided by DGT Research Ltd. (Al, 4.14 × 10-6 cm2 s-1; Mn, 5.09 × 10-6 cm2 s-1; at 20 °C) were used for the average temperatures measured during the deployment period. The volumes of the elution fluid and the resin layer were 2.0 and 0.16 mL, respectively. An elution factor of 0.8 was applied for both Al and Mn using 1 M superpure HNO3.4 All equipment was washed in 0.1 M HNO3 and rinsed in MilliQ water prior to use, and disposable gloves were worn during all handling. Experiments in the Laboratory. To investigate the DGT performance at low pH for Al and Mn in water similar to acid mine drainage, containers with 2.5 L of 0.01 M NaNO3(based on MilliQ water) were prepared and Al(NO3)3 and Mn(NO3)2 added to a concentration of ∼100 µg L-1 Al and Mn. The pH was adjusted to 2.5, 3.0, 3.5, 4.0, and 4.5 (three replicates) using superpure HNO3 and NaOH, and the pH was checked just prior to and after the experiment (WTW multi 340i meter with SenTix 41 pH gel electrode). An initial weak NaNO3 solution was used to avoid problems with DGT in very dilute solutions.18 A DGT sampler was then added to each container and suspended vertically halfway down the container. The solutions were stirred continuously throughout the experiment. The DGT devices were deployed for 3 h and then removed and rinsed with MilliQ water, prised open for removal of the resin gels, which were then placed in polyethylene vials, and eluted in 2 mL of 1 M superpure HNO3 for at least 24 h. A sample of the eluents were then taken, diluted 5 times, and analyzed by inductively coupled plasma mass spectroscopy (ICPMS; Agilent 7500CS) at the National Environmental Research Institute (NERI) in Roskilde, Denmark. Three blank DGTs were also measured following the same elution procedure. Water temperatures was measured at the beginning and at the end of the deployment period (