INSTRUMENTATION SPECIALTIES CO

Jun 17, 1970 - 9:00 Analyticaland Kinetic Applica- tions of AC Polarography. Donald E. Smith, Northwestern University. 10:30 Rotating. Disk and. Ring-...
0 downloads 6 Views 177KB Size
We

1970 ANALYTICAL SUMMER SYMPOSIUM June 17-19, 1970, at New Mexico State University, Las Cruces Roger G. Bates and Peter James Lingane, Cochairmen Wednesday morning, June 17 Peter James Lingane, Presiding 9:00 Introductory Remarks and Announcements—Robert Rowan, Jr. 9:15 Electroanalytical Chemistry in Molten Salt Solvent Systems. Herbert A. Laitinen, University of Illinois 10:45 Electrochemical Properties of BiPeter Sherological Membranes. wood, Harvard Medical School

Wednesday afternoon, June 17 Gordon J. Ewing, Presiding on 2:00 Electrocatalysis Mercury. Robert de Levie, Georgetown Univer-

sity 3:30 Analytical and Kinetic Applications of Cyclic Voltammetry. Irving Shain, University of Wisconsin

Thursday morning, June 18 Robert Rowan, Jr., Presiding 9:00 Analytical and Kinetic Applications of AC Polarography. Donald E. Smith, Northwestern University 10:30 Rotating Disk and Ring-Disk Electrodes: Past, Present, and Future. Stanley Bruckenstein, State University of New York at Buffalo

11:45 A Novel Electroanalytical Methodology: Oscilloscopic Polarography at a Vibrating Dropping Mercury Electrode. Joseph Jordan, Pennsylvania State University

HORIZONS

L. S. Ettre, Presiding

9:00 Welcome to Symposium 9:10 Introductory Lecture. A. I. M. Keulemans, Technische Hogeschool, Eindhoven, The Netherlands 9:30 Palladium—Hydrogen Systems in Gas Chromatography. J. E. Lovelock, P. G. Simmonds, G. R. Shoemake, and S. Rich, Jet Propulsion Laboratory, Pasadena, Calif. 9:55 Countercurrent Chromatography. Y. Ito and R. L. Bowman, National Institutes of Health, Bethesda, Md. 10:15 Drum TLC. A New Technique for Rapid, High Efficiency Separations. D. L. Saunders and L. R. Snyder, Union Oil Co. of California, Brea, Calif.

you.

. A. Laitinen, Presiding

2:00 Present Status and Future Developments in Spectroelectrochemistry. Theodore Kuwana, Case Western Reserve University 3:30 Understanding Organic Electrode Reactions. Royce W. Murray, University of North Carolina Friday morning, June 19 Roger G. Bates, Presiding

9:00 Analytical Applications of IonSelective Electrodes. Richard A. Durst, National Bureau of Standards 10:30 Organic Solvent Systems. Johannes F. Coetzee, University of Pittsburgh information write to: For further Prof. Robert Rowan, Jr., Department of Chemistry, Box 3C, New Mexico State University, University Park, N. M. 88001

The Sixth International Symposium on Advances in Chromatography will be held June 2 to 5, at the Hotel Fontainebleau in Miami Beach, Fla. A special feature of the meeting will be an exhibit of the latest instrumentation and books. Registration is limited and must be made in advance of the meeting. Preregistration forms and programs may be obtained from Dr. A. Zlatkis, Chemistry Department, University of Houston, Houston, Tex. 77004. The detailed technical program is given below.

NEW

for

Thursday afternoon, June 18

6th INTERNATIONAL SYMPOSIUM—ADVANCES IN CHROMATOGRAPHY

Tuesday Morning, June 2

calibrated this pump

10:30 INTERMISSION 10:45 Ultratrace Analysis of Volatile Substances with Gas Chromatographic Methods in the Sub PPM and PPB Range Down to 10' %. R. Kaiser, B.A.S.F., Ludwigshafen, Germany 11:00 Slow Processes, Catalysis, and Gas Chromatography. M. J. Walker, C. R. Mcllwrick, P. A. Rosser, and C. S. G. Phillips, Oxford University, England 11:20 The Plasma Chromatograph—A Detector for GC and Separator in GC-MS. M. J. Cohen, Franklin GNO Corp., West Palm Beach, Fla. 11:40 GLC Study of Solvent Effects on Complexing in Nonaqueous Media. D. L. Meen, F. Morris, and J. H. Purnell, University of Wales, Swansea, Wales (Continued on page 72A)

You don’t have to recalibrate it to

change flow rates, or after cleaning, or for use after a long idle period. You don’t have to replace peristaltic tubing or worry about corrosion of metal parts. The new ISCO Model 310 Metering Pump has a Teflon diaphragm driven by a solid state servo mechanism. Exact flow rates are read directly from dials on the face of the pump without referring to calibration tables. Accuracy and reproducibility are maintained at flow rates from 1.5 to 2,500 ml/hr at presto 50 psi. All parts consures tacting the pumped liquid are constructed of Teflon, Kel-F, glass, or similar chemically resistant materials.

Write for brochure complete details.

f —4700 jh

MP31 for

INSTRUMENTATION SPECIALTIES CO. SUPERIOR LINCOLN, NEBRASKA 68504 PHONE (4021 434-0231 CABLE ISC0LAB LINCOLN

Circle No. 32 on Readers' Service Card

ANALYTICAL CHEMISTRY, VOL. 42, NO. 4, APRIL 1970

·

71 A