INSTRUMENTS FOR RESEARCH & INDUSTRY

measurement. If 8 is the phase re tardation due to Q, it may be shown that the measured and true elliptic ities, Θ' and Θ, are related by the follow...
1 downloads 0 Views 189KB Size
REPORT

(4), in 1915, described an appara­ tus designed to measure ellipticity and rotation; later, a simplified version of this apparatus (5) was used to measure the ellipticities of weakly dichroic samples. The lat­ ter device is represented in Figure 17 and operates as follows: in the absence of an active sample, the quarter-wave plate Q is removed and the polarizer Ρ and analyzer A are first set to extinction. A is a Lippich-double-field analyzer whose angular setting is precisely defined at extinction by a condition of equal illumination in the two halves of its field. Q is then in­ serted and rotated until its axis is parallel to the transmission axis of the polarizer and extinction is re­ stored. Q is mechanically mounted in such a manner as to allow its re­ moval and reinsertion without dis­ turbing its relative orientation. The optically active sample S is now added, Q is removed and Ρ ro­ tated to compensate for optical ro­ tation due to the sample and restore extinction with A. Q is then rein­ serted and A rotated to restore ex­ tinction again; the angle of rota­ tion of A is then equal to the ellip­ ticity produced by the sample, pro­ vided Q is exactly a quarter-wave

POLARIZER

Ν

SAMPLE

plate at the wavelength used for the measurement. If 8 is the phase re­ tardation due to Q, it may be shown that the measured and true elliptic­ ities, Θ' and Θ, are related by the following expression: θ' = θ sin δ

In practice, it may be necessary to use a number of quarter-wave plates to cover a wide range of wavelengths. Kuhn and Braun {22) described in 1930 an apparatus employing photographic methods for measur­ ing circular dichroism in the visible and ultraviolet spectral regions ; this apparatus is represented in Figure 18: light from an arc source il­ luminates slit Si ; lens Li images Si on S 2 ; Ρ is a split polarizer consist­ ing of two Rochon polarizers wedged and cemented with a small angle, 2 θ , between their trans­ mission axes. The two ordinary beams from Ρ are linearly polarized at -f- Θ and — θ relative to the plane of incidence at total internal reflection in a specially designed Fresnel water-rhomb F ; the beams exiting F exhibit equal elliptical polarizations of opposite sense and of ellipticities ± θ. In the absence of a dichroic sample, the analyzer

λ •JfPLA' ΓΕ

DOUBLE-FIELD ANALYZER {LIPPICHÎ

V\ " ~s~

Figure 17. Measurement of circular dichroism and optical hat's apparatus ( 1 9 3 0 )

--is I

(28)

SAMPLE

J ANALYZER

'

When is a $2 Glove Bag better than a $1000 Dry Box? Both Glove Bag and dry box are made to do an equal job: provide a dry, inert or clean atmos­ phere. But l2R's polyethylene Glove Bag is faster to purge because it starts out flat . . . saving time and gas! It's also transparent, light and portable. Folded, Glove Bag slips easily into your coat pocket . . . expanded you have up to two cu. f t . * of clear work space! Most important, you may use it over and over again or discard it after a single experiment! And that's when Glove Bag is better than all the rigid dry boxes made! •Larger models available, write for literature.

^

rotation—Bru-

LENS | SPECTRO­ SCOPE SLIT PHOTOCRAPHIC PLATE

LEN

1(β)

J ^ Figure 18. Measurement of circular dichroism in the visible and u l t r a v i o l e t — Kuhn and Braun's apparatus ( 1 9 3 0 ) Circle No. 53 on Readers' Service Card

INSTRUMENTS FOR RESEARCH & INDUSTRY 106 Franklin Ave. Cheltenham, Pa.