Iodometric Microtitration for Mustard Gas - ACS Publications

Mustard gas in amounts varying,from less than 0.5 to 200 micro- grams may be determined accurately by iodometric titration from the reaction of dichlo...
0 downloads 0 Views 464KB Size
lodometric Microtitration for Mustard V. EVERETT KINSEY

AND

Gas

W. MORTON GRANT

H o w e Laboratory of Ophthalmology, Harvard Medical School, Boston, Mass.

Mustard gas in amounts varying,from less than 0.5 to 200 micrograms may b e determined accurately b y iodometric titration from the reaction of dichloramine T and mustard in organic solvents. Under the conditions outlined this reaction differentiates mustard from derivatives of mustard and is unaffected b y substances which can b e extracted, with the solvents used, from the biological materials tested (blood and cornea). A modification of this method, utilizing the quantitative catalyzing action of the sulfide on the reduction of dichloramine T in the presence of cyclohexanol, increases the sensitivity twentyfold in the range of 0.2 to 5 micrograms.

stability of dichloramine T in various solvents was determined by iodometrically measuring the amount of chlorine available at various intervals after preparation of the solutions (Table I). The solutions were kept at room temperature and not exposed to direct sunlight.

Table 11.

Efficiency of Solvents

( A l l . of 0.01 M sodium thiosulfate for 100 micrograms of mustard: Dichloramine T Solvents Purified Mustard Solvent kerosene CCh Benzene ' Cyclohexane Purified kerosene 0.5s 0.73 0.94 cc1k 0.80 0.59 ... . 1.00 Benzene ... 0.58 0.55 0.66 Cyclohexane Practical 1.05 1.03 0.69 1,oo Eastman Kodak Co. Xylene ... 0.46 ...

...

T

HE available methods for determining mustard g:ts (@,$'dichloroethyl sulfide) are chiefly nephelometric and have so many other limitations that it has not been possible heretofore to do quantitative work, particularly on residual mustard in biological material. For this purpose, a simple quxntit ative analytical method has been developed. The reaction described takes place in organic solvents, thereby eliminating competing hydrolysis which occurs in aqueous solution. It has a high degree of specificity for mustard compared with many mustard derivatives tested, especially n-hen these are extracted from aqueous solutions. The test appears to bo sufficiently sensitive to estimate less than 0.5 microyi:tm ( i f mustard with reasonable accuracy.

...

From the table it may be seen that an appreciable 1 0 s of chlorinating power occurs only in xylene and benzine. Accordingly, dichloramine T was dissolved (0.27,) in carbon tetrachloride, and mustard in concentrations of 50 and 150 micrograms per ml. was dissolved in purified kerosene or in cyclohexane; 1 ml. of the chlorinating solution was added to 1 ml. of the mustard solution, and samples were n ithdrawn periodically over a 30-minute period for titration. Figure 1shows that the reaction is essentially complete after 20 minute&. As a result of these experiments the reaction between dichloramine T and mustard was allowed to continue for 20 minutes in all experiments reported belon-. Since the amount of mustard is represented by a difference in the amount of sodium thiosulfate required to reduce the iodine liberated by the dichloramine T in the blank and in the sample, it is obviously desirable to keep the amount of dichloramine T present to a minimum. To establish this minimum quantity, the concentration of dichloianiine T n-as next varied from 0.10 to 0.20Cr, arid the amount of sodium thiosulfate required per microgram of mustard was determined. I t %-asfound that the

THE REACTION

The method is based on an oxidation, advantage being takvii of the well-known reaction of dichloramine T with mustard. The amount of chlorine available from dichloramine T after a part is used in chlorinating the mustard is determined by adding potassium iodide and acetic acid and titrating the amount of iodine liberated with sodium thiosulfate. The end point is sufhciently sharp to make starch unnecessary. The difference between the amount of sodium thiosulfate required with and without mustard gives a measureof the amount of mustard in the sample. The equation for this reaction cannot be given, since the extent of the reaction of mustard varies with the concentration of dichloramine T and the solvent used t o dissolve the mustard. Under the conditions in which the reaction is carried out it would appear that about 10 equivalents of chlorine are utilized poi molecule of mustard.

1.4 0

1.20

THE SOLVENTS

a3

In order to avoid extra blanks and possible inaccuracies resulting from side reactions of the dichloramine T with the solvents used as carriers for the mustard and the dichloramine T, the

/--

IS0 Y OF H IN CYCLOHEXANE

1.00

5: .so c

8

I

O

Table

3

I. Stability of Dichloramine T

Solvent Purified kerosene (commonly known as insecticide solvent) CCik, technical Cyclohexane (practical Eastman) Benzene, C.P. CHCla, U.S.P. Xylene, C.P. Benzine, C.P.

0.01 .M NasSaOs,per MI. of 0.2% DCT Solution Titrated 0.25 1 4 hours hour Immediately hour M1. M1. M1. Ml. 3.34 3.34 3.39 3.32 3.33 3.05 3.34

3.33 3.31 3.38 3.30 3.33 3.01 3.21

3.33 3.31 3.38 3.28 3.34 2.80 3.18

.eo .

.40

5 0 Y OF H IN PK

.z 0 0

3.33 3.32 3.37 3.27 3.33 2.21 3.05

0

I

I

I

I

5

IO

15

20

I 25

I

30

Time, Minuter

Figure I. Rate of Reduction of Dichloramine T in Cyclohexane or Purified Kerosene Solution H, mustard gar.

794

PK, Purified kerosene

ANALYTICAL E D I T I O N

December, 1946

-

.8 0

795

.20°/, DCT

.? 0

6 .60 f .50 2 $

.40

z

.20

5

.30

i .IO 0

I 0'

Figure 2.

I

I

I

I

40

-

I

I

80 100 120 Micrograms of Mustard Gar Reaction of Mustard Gas with Dichloramine 20

U I401

60

T

DCT, dichloramine T

dpgree of chlorination of the mustard increased slightly over this range of concentration of dichloramine T. The results of these experiments are shown in Figure 2. I n order t o find which solvent givcs the best results-ie., in which the greatest reaction occurs betn een the mustard and the dichloramine T-mustard (100 micrograms per ml.) and dichloramine (0.2%) were separately dissolved in different solvents and alloned to react. Table I1 shows the number of milliliters of 0.01 JI sodium thiosulfate equivalent t o 100 micrograms of mustard in each combination of solvents used. The extent of the reactiou is seen t o be dependent upon the nature of the solvents employed. In evciy case the presence of cyclohexane appeared to accentuate the reaction. Because of solubility properties, carbon tetrachloride lyas selected as the best solvent for the dichlordmine T and the mustard mas dissolved in either cyclohexane or purified keroscrie, for comparative purposes. Analyses made using, another lot of cyclohexane (practical, Eastman) gave somev-hat different results from those shown in

T I

/

H PRESENT'

I

I

MAXIMUM

I EFFECT OF H

I

I I

I

I

'

A

H

I 8

12

16

20

24

28

Reaction Time, Minutes

Figure 4. Proportion of Dichloramine T Reduced with Varying Time of Reaction in 1,6770 Cyclohexanol Solution at 27 C. With and without 3.33 micrograms of bis-8-chloroelhvl sulfide, H,per ml. presonl

Table 11. Thih suggests the advisability of running standard titration curves on each new lot of solvents or using C.P. grade cyclohexane; the latter gave a reproducible equivalent of 0.67 ml. of 0.01 X sodium thiosulfate per 100 micrograms of mustard and in addition had a negligible temperature coefficient. As a result of a search for an impurity in practical cyclohexane which presumably was responsible for the difference in sensitivity, it was found that the presence of cyclohexanol could produce a manifold increase in the sensitivity of the test. TThile the amount of the oxidizing agent reduced per unit of the sulfide could be increased about twentyfoid, the effect way found t o be present only over an extremely narrow concentration range of cyclohexanol in pure cyclohexane or purified kerosene. The relationship of the extent of reduction of dichloramine T in the presence of mustard to the concentration of cyclohexanol and the time of reaction was investigated. The amount of unreduced dichloramine T in the reaction mixtures was measured by iodometric titration. The proportion of a 0.1% solution of dichloramine T reduced in 20 minutes a t 26 O by 6.3 micrograms of mustard per ml. with varying concentrations of cyclohexanol present is shovm in the upper curve of Figure 3. The lower curve shows the amount of dichloramine T reduced when no mustard is present. It is obvious that for the concentrations of cyclohexanol shown, the presence of mustard increases the reaction. The greatest difference between the amount of dichloramine T used by the blank and the amount used for the given amount of mustard is seen t o occur a t approximately 1.67% cyclohexanol in the reaction mixture. The time of reaction of dichloramine T with muitard and cyclohexanol appears to be as critical as the concentration. Figure 4 shows that for 1.67% cyclohexanol the difference between the mustard-sensitized reduction of a 0.067% solution of dichloramine T (upper curve) and the reduction of a control solution without mustard is a maximum a t 20 minutes.

"/ 0.9

1.1

1.3

1.5

1.7

1.9

2.1

Per Cent Cvctohexdnol

Figure 3. Proportion of Dichloramine T Reduced in PO Minutes a t 26" C. in Cyclohexane or Purified Kerosene Solutions of Varying Content of Cyclohexanol A l o n e and with 6.3 mlcrogramr of bis-8-chloroeIhvl sulfide, H, per ml. present

PROCEDURE I

Analyses of known quantities of mustard in cyclohexane or purified kerosene were next carried out using the following technique:

INDUSTRIAL AND ENGINEERING CHEMISTRY

796

One milliliter of mustard solution was allowed t o react for 20 minutes Tvith 1 ml. of 0.27, dichloramine T dissolved in carbon tetrachloride a t 27" C. Four drops of saturated potassium iodide solution and 4 drops of glacial acetic acid were then added, the mixture was shaken, and 0.01 Ai' sodium thiosulfate was added until no color persisted. 1-igorous shaking is required as the end point of the titration is reached, and the whole procedure should be carricd out away from direct sunlight. Best results are obtained by maintaining uniform temperature conditions for the mustard-dichloramine T reaction.

1.60

Vol. 18, No. 12

It is evident that the amount of interference of the derivatives tested, even in organic solution, is relatively slight and that no interference occurs following 15 ater extraction, no doubt because the partition coefficient of the derivatives in lvater and purified kerosene greatly favors the water phase. Cornea and rabbit blood were next shaken with equal quantities of several organic solvents and the solvent was tested for the presence of titratable substances. Table I V shows that so long as purified kerosene, cyclohexane, or xylene is used for carrying out the extraction, no interference results. PARTITION EFFECT

1.40

In order to test lvhether the partition of mustard betiveen xater

a

1.2 0

or blood and purified kerosene and cyclohexane sufficiently favors

p 1.00 Z

*

$

-

.80

.60

5 .40 .2 0

0

o

Figure 5.

20

40 eo eo io0 120 140 160 Mlctogrrms of Mustard O M

Results of Analyses of Mustard Gas

the organic solvent to function properly as an extractant, equal quantities of these solvents containing mustard were shaken with water and blood for 15 seconds and the loss of mustard was measured. From Table V it may be seen that most of the mustard remains with the purified kerosene or cyclohexane when water is used to extract the mustard. When blood is used to make the extraction, cyclohexane retains most of the mustard. From these studies of possible interfering substances and partition coefficients it is concluded that the method described may be used for making mustard analyses in biological materials. This test carried out in the manner prescribed determines B,B'-dichloroethyl sulfide and not the first hydrolysis product of mustard, 8-hydroxyethyl-@'-chloroethyl sulfide. The latter,

Concenttatlon 0 to 160 rniaorrrms

Table IV. Biological Material Blanks

Figure 5 shows the results of mustard analyses performed over

MI. of 0.01 A4

a range of 0 to 160 micrograms. The top and bottom lines of the

figure refer to the resylts obtained when the mustard was dissolved in cyclohexane or purified kerosene, respectively. All the analyses in which the mustard was dissolved in purified kerosene were run separately by three different people. Figure 6 shows the analytical results in the range of 0.5 to 4.5 micrograms. The latter quantities of mustard were contained in 0.1 ml. of purified kerosene. For these analyses the following quantities of reagents were employed: 1 ml. of 0.2y0 of dichloramine T in carbon tetrachloride, 1 drop of potassium iodide, and 1 drop of glacial acetic acid. The titration was carried out with 0.02 Ji' sodium thiosulfate which was contained in a micropipet. It is clear that the usefulness of an analytical method for determining mustard in the presence of biological materials depends t o a large extent upon whether derivatives of mustard or substances extracted from the biological specimens interfere with the test. Accordingly, a series of compounds closely related to mustard was prepared and dissolved in purified kerosene either to saturation, or 1000 micrograms per ml. Analyses viere then made of these solutions using the technique previously outlined for determining mustard; the equivalent amount of sodium thiosulfate required is shown in Table I11 in comparison with that for 150 micrograms of mustard.

Solvent Uaed Purified kerosene Purified keroaene Cyclohexane Xylene Benzene cc1,

Derivatives Tested (C1CHnCHz)zS iClCHzCIlz~290 ClCHzCH?\sSO* HOCHzC Hz)?S (HOCH2CHn)zSO (H0CHnCHn)zSOz

Interference of Derivatives

Concentration Used in Purified Kerosene. 7/ml. 160

Saturated solution 1000 Saturated solution Saturated solution 1000

hll. of 0.01 M NaiWOa per M1. of Solution Original After extraction solution with HnO 1.03 1.02 0.35 Blank Blank Blank Blank 0.15 Blank 0.35 Blank Blank

Per Cent of hIustard ,Remaining after Extraction With Hg0 With blood

-,

98

88

99

97

I2

j sm

.IO

.08 .06

8

Table 111.

per MI. Nad3a0: of Solution Blank Blank Blank Blank 0.08 0.03

Table V. Partition Effect Original Mustard Solution In purified kerosene, 2 0 0 7 erml. In cyolotexane, 125 per rnl

-$ . 0 4

~~

hlaterial Extracted Cornea Blood Blood Blood Blood Blood

i'

.02

0

o

1.0

2.0

3.0

4.0

5.0

Micrograms of Mustard G a r

Figure 6. Results of Analyses

of

Mustard Gas

Concentration 0 t o 5 micrograms

ANALYTICAL EDITION

December, 1946

it was ascertained from the pure compound, is highly watersoluble and remains in the water phase when purified kerosene is used to extract the mustard; and only a trace of the hydrolysis product is extracted by cyclohexane. Sulfonium salts similarly remain in the water phase and are not determined by this method. (The isolation of fi-hydroxyethyl-~'-chloroet~hylsulfide and its subsequent synthesis will be described in the Journal of the American Chemical Society.) The reagent with the most desirable physical and solvent properties for performing the extractions was found to consist of a mixture of 80% cyclohexane and 207, purified kerosene. Maximum and essentially complete extraction of mustard was obtained from water by vigorous shaking with an equal volume of this mixture for 20 seconds, and from rabbit blood by 2 minutes' shaking. Application of this method to a study of hydrolysis rates of mustard in water, salt solutions, and blood will be discussed in a subsequent publication in the Journal of Biological Chemistry. PROCEDURE II

For applications necessitating the greatest sensitivity in the range of 0.2 to 5 micrograms of mustard gas the following procedure, which takes 'advantage of the sensitizing action of cyclohexanol, may be utilized: One milliliter of cyclohexane (Eastman Kodak Co., pure) containing 0 t o 5 micrograms of mustard is added to 1 ml. of a 5.00% solution (by volume) of cyclohexanol in

A

797

purified kerosene (Insecti-Sol insecticide solvent) or pure cyclohexane. The mixture, in a test tube, is placed in a thermostatic water bath. The temperature coefficient of the sensitized reaction was found to be large enough to require careful control of the temperature a t which the reaction with dichloramine T takes place. This is best accomplished by means of a thermostatic bath controlled to within a t least 0.1 C., preferably in the range of 25 to 28" C. One milliliter of 0.1% dichloramine T in carbon tetrachloride is added and exactly 20 minutes later 4 drops of saturated potassium iodide solution and 4 drops of glacial acetic acid are added with shaking. The iodine liberated by the unreacted dichloramine T is titrated with 0.01 M sodium thiosulfate to a colorless end point. The difference in amount of thiosulfate required by the blank and that required when various known amounts of mustard are present gives a measure of the quantity of mustard present. In the range of 0.2 to 5.0 micrograms of rnufitard the difference in amount of thiosulfate n-as 0.2 ml. of 0.01 M solution per microgram of mustard. There was a straight-line relationship of thiosulfate to mustard. In the range of 0.2 to 1.0 microgram of mustard the average absolute deviation from the mean for ten individual t,itrations was equivalent to 0.03 microgram. THEwork described in this paper was done under a contract, recommended by the Committee on Medical Research, between the Office of Scientific Research and Development and Harvard University.

Source of Error in the Gutzeit M e t h o d For Arsenic N. I. GOLDSTONE Department of Health, City of N e w York, N. Y.

By using a constant-area zinc pellet for the generation of gases, rlightly modifying the method of sensitizing the absorption strips, and y e t maintaining the simplicity of the Gutzeit procedure, the error i s reduced.

I

N T H E microdetermination of arsenic the Gutzeit method

continues to maintain its popularity over other procedures despite the rather poor opinion of its accuracy held by analytical chemists. The reason for this popularity lies in the simplicity of both the procedure and the apparatus required. Investigators (10, 21) generally concluded that the requirements of microchemical accuracy are wanting and that relatively consistent results can be achieved only after considerable experience with the procedure. In attempts to reduce the error the principal modifications proposed were: Substitution of paper disks (19, 22) or cotton threads (9, 4, 16, 16) for paper absorption strips. Use of activators or zinc alloys (12, 15) for the generation of gases. Temperature control on whole or part of the generator (11, 14, 16). Applications of the molybdenum blue reaction (9, 17, 20, 24). Absorption of arsine into a liquid followed by a titration procedure (8). Spot-filtration of arsine under vacuum (22). Kone of these variation. has achieved general acceptance, because they require the use of special apparatus or the procedure is too complicated. The method of Cassil snd Kichmann produces a satisfactory degree of accuracy and shortens the time required for an analysis, but special apparatus and a supplementary iodine titration are necessary. The molybdenum blue procedures and the spot-filtration modification are subject t o similar limitations, and How in his searching investigation prescribed a set of carefully standardized conditions in addition to special apparatus which might be acceptable to a laboratory where arsenic analysis is a day by day routine, but would not be adopted readily by the analyst who makes an occasional arsenic deter-

mination. Furthermore, the evaluation of these variations by collaborative effort (6, 7 , 18, 23) has not been completed and hence the official method ( 1 ) still enjoys considerable vogue. Since the Gutzeit method is empirical, consistent results depend on close adherence to uniformity in reagents, apparatus, and procedure, rigid specifications for which are prescribed by the official met,hpd in all particulars save one-the zinc used for generation of gases. Where stick zinc is used the analyst' is instructed to sort out the overactive or underactive pieces on the basis of visual observation of the rate of gas evolution during activation, and to equalize the surface area exposed as far 8 8 possible. Cassil (5)has shown that the principal factors influencing the length and intensity of the stain are the rate of evolution of hydrogen and the method of impregnating the strips. He found that a definite rate of evolution could not be maintained by the use of granular zinc, though the most satisfactory stains were produced with 20-mesh spherical granular zinc. Gross (13) obtained a substantially greater recovery of arsenic with stick zinc than with 30-mesh granular zinc under identical conditions. The present investigation was pursued on the theory that if a zinc pellet could be devised which exposed a constant surface area to the surrounding liquid, a uniform rate of evolution could be maintained and a more constant reproducibility in length and intensity of stain would result. The author devised such a pellet by molding zinc in the form of cylindrical rod of definite crosssectional area and rendering the cylindrical surface inactive by a coating of wax, leaving the two plane circular ends as generating surfaces. EXPERIMENTAL

PREPARATION OF PELLETS.For molding zinc cylindrical rods 15 X 125 mm. Pyrex test tubes mere employed. Since these vary somewhat, a number having identical inside diameters were selected, and tested with a pair of inside calipers. A tube is clamped on a stand in a vertical position and carefully preheated with a Bunsen burner while a sufficient quantity of arsenic-free zinc is being melted in a Pyrex beaker, then filled with the molten zinc. The tube is tapped t o eliminate air pockets and the zinc is