JCPDS INTERNATIONAL CENTRE - Analytical Chemistry (ACS

May 29, 2012 - JCPDS INTERNATIONAL CENTRE. Anal. Chem. , 1983, 55 (6), pp 644A–644A. DOI: 10.1021/ac00257a766. Publication Date: May 1983. ACS Legac...
0 downloads 8 Views 1MB Size
MCI Automatic Moisture Meter. Reliable, Fast and Easy. Incorporates coulometry principle applied to Karl Fischer titration. Operation is full-automatic. Measuring time is shortened. Accuracy is within 5,ug for 10,ug—lmg H2O and within 0.5% for 1—30mg H 2 0 . Wide-range applications include measurement of ultra-trace water content in liquids, solids and gases. Range: 10^g—30mg H2O. An optional water vaporizer for speedy and accurate measurement of water content in plastics, grain, etc.

Printer (optional,

(δ = 2.9 ppm), suggesting a CH 3 -CH-CH 2 group; and a singlet (δ = 1.5 ppm), which by deuterium exchange was shown to be from an -OH group. The 13C NMR spectra obtained from the white crystalline solid ( Ή coupled and decoupled) showed 14 magnetically nonequivalent carbon sites, their associated bondings, and the number of attached hydrogen atoms. We also saw that the phenyl ring was unsymmetrically trisubstituted. The chemical shifts of the satu­ rated carbons showed that the pentamethylindan structure was retained and that the additional groups (CH 3 -CH-CH 2 OH) were associated with the phenyl ring. Taking into account the above in­ formation together with the molecular formula of C17H26O, the white crystal­ line solid was identified as galaxolide alcohol.

CA-02 Moisture Meter with Printer

MITSUBISHI CHEMICAL INDUSTRIES LIMITED

Instruments Dept., Mitsubishi Bldg., 5 - 2 , M a r u n o u c h i 2 - c h o m e , Chiyoda-ku T o k y o , 100 Japan Telex: J 2 4 9 0 1 Cable Address: KASEICO TOKYO CIRCLE 140 ON READER SERVICE CARD

2-(l,l,2,3,3-pentamethylindan-5-yl)propan-1-ol or galaxolide alcohol Conclusion

POWDER DIFFRACTION FILE THE STANDARD REFERENCE IN POWDER DIFFRACTION ANALYSIS FOR USE B Y . . .

• ALL POWDER DIFFRACTION ANALYSTS SET 32

• EDUCATORS POWDER DIFFRACTION DATA from the JCPDS ASSOCIATESHIP at the NBS

•CRYSTALLOGRAPHERS CRYSTAL DATA

• METALLURGISTS SELECTED POWDER DIFFRACTION DATA for METALS and ALLOYS

• MINERALOGISTS SELECTED POWDER DIFFRACTION DATA for MINERALS THE MINERAL POWDER DIFFRACTION FILE for further information write:

JCPDS

INTERNATIONAL CENTRE FOR DIFFRACTION DATA 1601 Park Lane, Swarthmore, PA 19081 (215) 328-9400 Cable: JCPDS

The unknown pollutant was found to be a mixture of pentamethylindan and galaxolide alcohol, but these were unusual chemicals to be found floating on the surface of a lake. In fact, very little mention of them is made any­ where 'n chemical literature, and no reference spectra could be found for these compounds. Pure reference ma­ terials were obtained subsequently, and their IR, NMR, and mass spectra were found to match those of the sepa­ rated oil and white solid. Some "fin­ gerprint" matches are shown in Fig­ ures lb, 3b, and 4b. Identifying the compounds, how­ ever, solved only part of the mystery. The question still remained: Where had they come from? Actually, the rare occurrence of the compounds proved to be of assistance in tracing their source. Eventually it was found that a manufacturer of perfumery products used them as intermediates, that waste effluent from the factory was regularly disposed of by a contrac­ tor in a waste tip not far from the lake, and that material escaped from this waste tip into a channel connecting to the lake. Once this detective work was completed, the mystery had been solved. Adapted in part from European News, 1982, Vol. 40.

CIRCLE 112 ON READER SERVICE CARD

644 A · ANALYTICAL CHEMISTRY, VOL. 55, NO. 6, MAY 1983

Spectroscopy