Long-Wavelength Long-Lifetime Luminophores - American Chemical

Baltimore, 725 West Lombard Street, Baltimore, Maryland 21201. We describe a new approach to making luminophores that display long emission wavelength...
1 downloads 0 Views 132KB Size
Anal. Chem. 2001, 73, 4277-4285

Long-Wavelength Long-Lifetime Luminophores Badri P. Maliwal, Zgymunt Gryczynski, and Joseph R. Lakowicz*

Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland at Baltimore, 725 West Lombard Street, Baltimore, Maryland 21201

We describe a new approach to making luminophores that display long emission wavelengths, long decay times, and high quantum yields. These luminophores are covalently linked pairs with a long-lifetime resonance-energy-transfer (RET) donor and a long-wavelength acceptor. The donor was a ruthenium (Ru) metal-ligand complex. The acceptor was the Texas Red. The donor and acceptor were covalently linked by polyproline spacers. The long-lifetime donor results in a long-lived component in the acceptor decay, which is due to RET. Importantly, the quantum yield of the luminophores approaches that of the higher quantum yield acceptor, rather than the lower quantum yield typical of metal-ligand complexes. The emission maxima and decay time of such tandem luminophores can be readily adjusted by selection of the donor, acceptor, and distance between them. Luminophores with these useful spectral properties can also be donor-acceptor pairs brought into close proximity by some biochemical association reaction. Luminophores with long-wavelength emission and long lifetimes can have numerous applications in biophysics, clinical diagnostics, DNA analysis, and drug discovery.

available. Such probes are widely used in the biochemical and medical applications of fluorescence, including protein labeling, DNA sequencing,3-9 and in vivo measurements.10-13 Many of the red/near infrared (NIR) fluorophores display high extinction coefficients and good quantum yields, both of which indicate the absorption and emission electronic transitions are strongly allowed. Consequently, the decay times of the red/NIR probes are typically under 2 ns, as is predicted by theory.14 The longest lifetime for red/NIR fluorophores is under 5 ns, which is found for some phthalocyanines and similar structures.15-17 We are not aware of any approach to increasing the decay times without the use of an alternative process, such as phosphorescence. We now describe a new approach to creating red/NIR luminophores that display both long decay times and high quantum yields. This approach is illustrated by the tandem luminophore in Scheme 1. This luminophore is based on resonance energy transfer (RET) from the ruthenium metal-ligand complexes (MLC) donor to the Texas Red (TR) acceptor. We use the term luminophore because emission from the MLCs displays both singlet and triplet character. We use a metal-ligand complex as the donor because the transition from the triplet excited state to the singlet ground state is not allowed, and these molecules

In fluorescence spectroscopy, the information available from an experiment is largely determined by the spectral properties of the fluorophore. For example, the anisotropy decay of fluorophores that display nanosecond decay times can be used to measure motions on the nanosecond time scale. If slower motions on the microsecond time scale are of interest, then it is necessary to use fluorophores that display microsecond decay times. Furthermore, intracellular fluorophores that require UV excitation result in a background of undersired emission due to the intrinsic fluorescence of cells and tissues. This autofluorescence from biological samples is mostly on the nanosecond time scale, and its intensity decreases at longer excitation and emission wavelengths. For these reasons, there is a need for fluorophores that display both long emission wavelengths and long decay times. To our knowledge, there are no luminophores that display the desired spectral properties of long decay times, long excitation and emission wavelengths, and high quantum yields. During the past decade, a good number of fluorophores that display red or near-infrared (NIR) emission1-2 have become

(3) Southwick, P. L.; Ernst, L. A.; Tauriello, E. W.; Parker, S. R.; Mujumdar, R. B.; Mujumdar, S. W.; Clever, H. A.; Waggoner, A. S. Cytometry 1990, 11, 418-430. (4) Rahavendran, S. V.; Karnes, H. T. J. Pharm. Biomed. Anal. 1996, 15, 8398. (5) Rahavendran, S. V.; Karnes, H. T. Anal. Chem. 1996, 68, 3763-3768. (6) Kessler, M. A.; Wolfbeis, O. S. Anal. Biochem. 1992, 200, 254-259. (7) Middendorf, L.; Amen, J.; Bruce, R.; Draney, D.; DeGraff, D.; Gewecke, J.; Grone, D.; Humphrey, P.; Little, G.; Lugade, A.; Narayanan, N.; Oommen, A.; Osterman, H.; Peterson, R.; Rada, J.; Raghavachari, R.; Roemer, S. In Near-Infrared Dyes for High Technology Applications; Daehen, S., Ed.; Kluwer Academic Publishers: Netherlands, 1998; pp 21-54. (8) Flanagan, J. H.; Romero, S. E.; Legendre, B. L.; Hammer, R. P.; Soper, A. SPIE Proc. 1997, 2980, 328-337. (9) Owens, C. V.; Davidson, Y. Y.; Kar, S.; Soper, S. A. Anal. Chem. 1997, 69, 1256-1261. (10) Abugo, O. O.; Nair, R.; Lakowicz, J. R. Anal. Biochem. 2000, 279, 142150. (11) Dorshow, R. B.; Bugaj, J. E.; Burleigh, B. D.; Duncan, J. R.; Johnson, M. A.; Jones, W. B. J. Biomed. Optics 1998, 3, 340-345. (12) Kanda, M.; Niwa, S. Appl. Optics 1992, 31, 6668-6675. (13) Bollinger, A.; Saesseli, B.; Hoffmann, U.; Franzeck, U. K. Circulation 1991, 83, 546-551. (14) Strickler, S. J.; Berg, R. A. J. Chem. Phys. 1962, 37, 814-822. (15) Nikolaitchik, A. V.; Korth, O.; Rodgers, M. A. J. J. Phys. Chem. A. 1999, 103, 7587-7596. (16) del Ray, B.; Keller, U.; Torres, T.; Rojo, G.; Aguillo-Lopez; F.; Nonell, S.; Marti, C.; Brasselet, S.; Ledoux, I.; Zyss, J. J. Am. Chem. Soc. 1998, 120, 12808-12817. (17) Howe, L.; Sucheta, A.; Einarsdottir, O.; Zhang, J. Z. Photochem. Photobiol. 1999, 69, 617-623.

(1) Thompson, R. B. In Topics in Fluorescence Spectroscopy; Lakowicz, J.R., Ed.; Plenum Press: New York, 1994; Vol.4, pp 151-222. (2) Daehne, S.; Resch-Genger, U.; Wolfbeis, O. S. In Near-Infrared Dyes for High Technology Applications; Daehen, S., Ed.; Kluwer Academic Publishers: Netherlands, 1998, p 458. 10.1021/ac0101050 CCC: $20.00 Published on Web 07/27/2001

© 2001 American Chemical Society

Analytical Chemistry, Vol. 73, No. 17, September 1, 2001 4277

Scheme 1. Chemical Structure of a Ru MLC Covalently Linked to Texas Red (D-A)a

a The donor-alone control had the sulfhydryl group blocked with iodoacetamide. The acceptor alone was the peptide without the MLC group.

display long lifetimes ranging from 100 ns to 10 µs.18-20 Some MLCs that display still longer decay times from 50 to 260 µs20-23 are known. Because of the long lifetimes, ease of synthesis, and range of spectral properties, the MLCs have been developed as luminescent probes in physical, analytical, and biophysical chemistry.24-31 Although the MLCs display some favorable spectral properties, other properties are less favorable. The MLCs display low extinction coefficients, typically less than 20 000 M-1 cm-1, which is one reason for the long decay times,14 but which result in decreased sensitivity. Additionally, most MLCs display low quantum yields, which rarely exceed 0.1, and the quantum yields of the MLCs with the longest decay times are often smaller.20-23 Finally, the emission spectra are broad, which makes it more (18) Kalayanasundarm, K. Photochemistry of Polypyridine and Porphyrin Complexes; Academic Press: New York, 1992. (19) Juris, A.; Balzani, V.; Barigelletti, F.; Campagna, S.; Belser, P.; Von Zelewsky, A. Coord. Chem. Rev. 1988, 84, 85-277. (20) Tyson, D. S.; Castellano, F. N. J. Phys. Chem. A. 1999, 103, 10955-10960. (21) Stiffens, D. J.; Aarnts, M. P.; Rossenaar, B. D.; Vlcek, A. Pure Appl. Chem. 1997, 69, 831-835. (22) Simon, J. A.; Curry, S. L.; Schmehl, R. H.; Schatz, T. R.; Piotrowiak, P.; Jin, X.; Thummel, R. P. J. Am. Chem. Soc. 1997, 119, 11012-11022. (23) Harriman, A.; Hissler, M.; Khatyr, A.; Ziessel, R. Chem. Commun. 1999, 735-736. (24) Demas, J. N.; DeGraff, B. A. Anal. Chem. 1991, 63, 829A-837A. (25) Demas, J. N.; DeGraff, B. A. In Topics in Fluorescence Spectroscopy; Lakowicz, J. R., Ed.; Plenum Press: New York, 1994; Vol. 4, pp 71-107. (26) Terpetschnig, E.; Szmacinski, H.; Malak, H.; Lakowicz, J. R. Biophys. J. 1995, 68, 342-350. (27) Szmacinski, H.; Terpetschnig, E.; Lakowicz, J. R. Biophys. Chem. 1996, 62, 109-120. (28) Guo, X.-Q.; Castellano, F. N.; Li, L.; Lakowicz, J. R. Anal. Chem. 1998, 70, 632-637. (29) Murtaza, Z.; Lakowicz, J. R. SPIE Proc. 1999, 3602, 309-315. (30) Grigg, R.; Norbert, W. D. J. A. J. Chem. Soc. Chem. Commun. 1992, 13001302. (31) Lippitsch, M. E.; Wolfbeis, O. S. Anal. Chim. 1988, 205, 1-6.

4278

Analytical Chemistry, Vol. 73, No. 17, September 1, 2001

difficult to quantify the MLC emission in the presence of autofluorescence, because the background is also widely distributed across the wavelength scale. In the present report, we describe a generic approach to overcoming these limitations of the available MLC and red/NIR probes, as typified in Scheme 1. The luminophore consists of a MLC, which displays a long lifetime, that is covalently linked to a high-quantum-yield acceptor. The luminophore is excited at a wavelength where the MLC absorbs, typically near 450 ns for the ruthenium (Ru) MLCs. The emission is red-shifted to longer wavelengths by RET to the red/NIR emitting acceptor. Some long wavelength probes have low absorption near 450 nm, so that most of the incident light is absorbed by the donor. Much, if not most, of the acceptor emission is, thus, due to energy transfer from the MLC. Following pulsed excitation, the excited state population of the MLC becomes the only excitation source for the acceptor, which continues to emit as long as MLCs remain in the excited state. Such luminophores can still display long decay times in the presence of RET. For instance, if the MLC donor displays a lifetime of 1 µs in the absence of RET, the lifetime of the luminophore is expected to decrease to 100 ns if the RET efficiency is 90%. A decay time of 100 ns is still significantly longer than that seen with known red/NIR probes and also significantly longer than most autofluorescence, which typically decays in 10 ns. With a 10-µs-decay-time donor, 90% transfer efficiency will result in a 1-µs component in the acceptor decay. An important feature of a MLC tandem luminophore is an increased quantum yield. When energy transfer is rapid, most of the energy is transferred from the MLC to the acceptor. In this case, the quantum yield of the luminophore approaches the higher value of the directly excited acceptor rather than the lower value of the MLC. We demonstrated the practical usefulness of these tandem luminophores using the covalently linked donor-acceptor (D-A) pairs shown in Scheme 1. These D-A pairs can be considered to be the probe or reagent, in the same manner that linked DNA pairs have been developed for DNA sequencing.32-33 Alternatively, this unique long-lifetime high-quantum-yield emission can be the result of protein or nucleic acid association reactions. MATERIALS AND METHODS The Texas Red iodoacetamide with a C5 linker was purchased from Molecular Probes, Inc. The [Ru(bpy)2 (amino phenanthroline)]2+ was a gift from Dr. Jonathan Dattelbaum. The Ru MLC was synthesized following published procedures.18,19,24,25 It was converted into isothiocyanate by treating with 500 µL of thiophosgene in 1 mL of acetone for 3 h. Both the solvent and the thiophosgene were removed under a stream of nitrogen, and the isothiocyanate was used immediately. The oligoproline peptides with a cysteine at the C-terminus were synthesized at the biopolymer facility of the University of Maryland School of Medicine, Baltimore. The crude peptides were purified by RP-HPLC on a C18 column using a gradient of 100% acetonitrole containing 0.05% TFA in 0.1% TFA. The molecular weights of the peptides were confirmed by mass spectroscopy. (32) Ju, J.; Ruan, C.; Fuller, C. W.; Glazer, A. N.; Mathies, R. A. Proc. Natl. Acad. Sci. U.S.A. 1995, 92, 4347-4351. (33) Ju, J.; Glazer, A. N.; Mathies, R. A. Nat. Med. 1996, 2, 246-249.

The peptides were labeled first with the acceptor. Typically, a millimolar solution of the peptide in 0.2 M bicarbonate buffer, pH 8.5, was reacted with a 2-fold excess iodoacetamide for 6 h. The resulting peptide was purified from the free probe using a column of Sephadex G-15 running in 20% DMF solution. The labeled peptide was further purified by HPLC. To prepare the double-labeled peptide, the acceptor-labeled peptide was further reacted with a 5-fold excess Ru isothiocyanate in 0.2 M bicarbonate, pH 9.0, for 6 h. The peptide was separated from the free probe by passing through a Sephadex G-15 column and was further purified on HPLC. To prepare the donor-only peptide, the sulfydryl group was first blocked using a 5-fold excess iodoacetic acid at pH 8.5 for 1 h, and to the same reaction mixture, a 5-fold excess of the isothiocyanate was added, the pH was adjusted to 9, and it allowed to react for 6 h. The free dye was separated on a Sephadex G-15 column, and the donor-labeled peptide was purified by HPLC. The purified peptides were lyophilized and stored as water solutions at 4 °C. The steady-state measurements were performed in an aqueous 5 mM hepes, 100 mM NaCl solution, pH 8. The measurements in propylene glycol were without buffer, with the propylene glycol at least 98%, the remainder being water. The peptide concentrations were