National Instrument Laboratories, INCORPORATED

Less than 1 micron backlash. Better than 1 micron measuring accuracy. X-Y indexing to 1A micron. EIGHT AVAILABLE TWO-COORDINATE FORMATS:...
1 downloads 0 Views 156KB Size
THE N.I.L

ELECTROLAB —for Electrochemical Research, Biochemical and Routine Analysis, and Industrial Process Control THE COMPLETE AND COMPACT ELECTROANALYTICAL LABORATORY IN ONE INSTRUMENT 17 Electroanalytical Modes of Operation at Low Cost, with High Accuracy, and Built-in Sequencing

Glatit

94*âisu4me#itl pA&i&nti,

COMPUTER COMPATIBLE MEASURING ENGINES

HIGHEST A C C U R A C Y Precision lead-screw driven Less than 1 m i c r o n b a c k l a s h Better than 1 m i c r o n m e a s u r i n g a c c u r a c y X-Y i n d e x i n g to 1A m i c r o n EIGHT AVAILABLE T W O - C O O R D I N A T E F O R M A T S :

The light display on the panel illuminates only those controls associated with a different mode of operation. When the Function Program switch above is turned to one of four positions, the corresponding switch setting indicates the analytical mode, the variable held constant, and the measured variable. FEATURES •

Light display logic illuminates all controls, directs opeiator for each analytical mode. • Connects to any strip chart recorder with a sensitivity up to 100 millivolts full scale. •

Buffer amplifier (10-'- ohms) isolation permits operation of four electrodes in a common solution without drawing common currents.



AC operation over a range of 0-10 KHZ at low current (0-5 ma) and 0-1 KHZ at high current (0-1 A).



Ail solid state components. For complete description and ordering information send for BULLETIN 4-300

NIL Phone: 933-1144 Area Code: 301

National Instrument Laboratories, INCORPORATED

12300 Parklawn Drive, Rockville, M d . 2 0 8 5 2 In Metropolitan Washington, D. C. Circle No 27 on Readers' Service Card

140 A



ANALYTICAL CHEMISTRY

50 50 50 100

mm mm mm mm

X X X X

250 350 450 250

mm mm mm mm

100 100 130 250

mm mm mm mm

X X X X

350 450 250 250

mm mm mm mm

X-Y indexing to VA m i c r o n is possible for manual or a u t o m a t i c p o s i t i o n i n g by high and low-speed s c a n ning m o t o r s . VERSATILE This e q u i p m e n t can be made available with c o m p l e t e instrumentation for installations such as the f o l l o w i n g : Spectra-wavelength measuring comparators Star-plate measuring comparators Fast-scan d e n s i t o m e t e r s High-resolution microphotometers Film readers w i t h position and density readout C o n t i n u o u s l y s e l f - c a l i b r a t i n g iris p h o t o m e t e r s

Oscilloscope pattern permit H accurate line scllhifis wiliiiii % micron Send for brochures and formal Write or phone.

specifications.

GRANT INSTRUMENTS 1805 Eastshore Hwy., Berkeley, California 94710 (415) 548-0101 Circle No. 37 on Readers' Service Card