PDF w

vard, Melbourne, Florida 32901. Tele- phone (305) 727-2046. CIRCLE 195 ON READER SERVICE CARD .... and its associated grating ghosts,thus bringing out...
15 downloads 19 Views 2MB Size
NEW

PRODUCTS

Reagent cleaning system will eliminate contaminating amounts of Sb, Bi, Cd, Cu, Co, Ga, Ag, In, Ir, Fe, Pb, Mn, Ni, Os, Pd, Pt, Rh, Ru, Ag, Tl, Sn, and Zn in reagent solutions. The system re­ moves trace amounts down to 0.05 ppb by the use of a constant potential electrochemical procedure. Consist­ ing of a 4-1 flask, small electronic unit, mercury pool working electrode (not supplied), counter electrode, and reference electrode compartments, any reagent, such as NaCI or NaN0 4 , that will conduct a current can be cleaned. From $695. Environmental Sciences Assoc, Inc. 401

Λ ί 8C'*fU&6S*.Wt

f*t~$&fo\>

EU 721 uv/vis ratio-recording spectrophotometer uses the concept of programmed and automated alternate positioning of reference and sample cells in a fixed light beam. Thus the baseline is better than 0.001 absorbance unit from 185 to 850 nm. This instrument is also the first available recording spectrophotometer designed for simple interfacing to small computers. Resolution of the filter grating monochromator is 0.1-0.5 nm. Various readouts and accessories are available. The EU 707 double-beam system is a research quality uv/vis instrument featuring spectral resolution of better than 0.1 nm throughout the spectral range of 190-800 nm; accessory detectors extend the range into the ir. EU 7 2 1 , $4660; EU 707, $5375. Heath/Schlumberger. 616-983-3961 402

GC-4BM gas chromatograph features an integrated analysis unit which contains a sample injection port, column, and detector. Analysis units can be readily changed for different analyses eliminating cross contamination problems. Standard models available include temperature programming plus flame ionization detector or elec­ tron capture, or both; other combinations of detectors and isothermal units are available on special order. Another feature of these chromatographs is the allglass flow line, from sample injection port to detector. Shimadzu Seisakusho, Ltd., Foreign Trade Dept., 14-5, Uchikanda 1-chome, Chiyodaku, Tokyo, Japan 403 ANALYTICAL CHEMISTRY, VOL. 44, NO. 2, FEBRUARY 1972



143 A

New Products

High pressure Dialgrad gradient pump forms gradients at pressures in excess of 2000 psi and at flow rates up to 160 ml/hour. The Model 384 is applicable to small bore liquid chromatography columns or in other applications. Any two-component gradient can be dialed directly into the pump, and many vari­ ables may be incorporated into the gradient by using multiple mixtures for the two components. $3895. Instru­ mentation Specialties Co. 402-4340231 404

HOW GOOD CAN A $5,985* NMR SYSTEM BE?

ο H3C

Η

CrotonakJehyde

J ,_JJIL Ι

ι

I

I

.

I

Ι

ι

Ι

S ppm

ι

I

l



l

.

ι

Take a close look at the crotonaldehyde spectrum on this page and you'll see that the low-cost EM-300 Spectrometer is more than capable of producing high resolution results. There are, of course, many reasons why more than 60 industrial and academic users have already selected the EM-300. One reason is that with our built-in integrator you can perform quantitative analysis. Another is the fact that you can have calibrated spectra as a result of the EM-300's calibrated sweeps and linear readout which can be referenced to any particular peak.

Model 6500T basic gas chromatograph has been designed for compatibility with the new Model 7200 10 mV gc re­ corder. The 6500T produces a full 10 mV output at the instrument's maxi­ mum sensitivity. This increased out­ put, without compromising peak sensi­ tivity or zero stability, is the only differ­ ence between the 6500T and the com­ pany's standard Model 6500. The re­ corder is small in size (10" χ 10" χ 5"), lightweight (8.5 lb), and has simple controls. It is made by Laboratory Data Control to Carle specifications. The Model 6500T gc and Model 7200 re­ corder are each priced at $465. Carle Instruments, Inc. 714-879-9900 405 CRS-210 integrator for amino acid analysis is built around the company's 200 series framework and is fully com­ patible with all commercial amino acid analyzers. The instrument contains many improvements over its predeces­ sor, the CRS-110A, without increasing the cost. New features include two separate pairs of timers, set with digi­ tal thumbwheel on the front panel to govern channel switching and counts down to buffer changes. $6250. Infotronics Corp. 415-968-9710 406

The EM-300 is one of a unified line of products from Varian Anaspect... specialist in quality instruments designed to give you more data per dollar. For Application Bulletin No. 300-3 covering 20 representative spectra from our EM-300 reference book of 150 compounds, call (415) 326-4000. Or write Varian Anaspect, 611 Hansen Way, Palo Alto, California 94303. *$5,270 without recorder

varian anaspect See the Varian booth at the Pittsburgh Conference CIRCLE 185 ON READER SERVICE CARD

144 A



ANALYTICAL CHEMISTRY, VOL. 44, NO. 2, FEBRUARY 1972

SBR3 Titrigraph complements a titra­ tion system consisting of a TTT2 titrator and a Radiometer autoburet. Features of the Titragraph include built-in derivative information for easy endpoint detection; wide range of chart speeds; expanded volume scale; and 4-step 35-cm chart movement to cover the range 1.75-17.5 pH units. $1180. The London Co. 216-871-8900 407

New Products

Want total reflectance performance in the infrared? Test drive

BIO•RAD stocks ® DOWEX ion exchange resins, anion and cation, in 44 types and bead sizes.

For immediate shipment! Need we say more? Only that BIO-RAD's AG® resins—the research standard of excellence— are also available for those applications requiring the highest chemical pnrity. For details on DOWEX and AG, send for our new complete catalog and price list.

-BIO'RAD ) j£aé»tAim£e& 32nd & Griffin Ave. Richmond, Cal. 94804 (415) 234-4130 220 Maple Ave. Rockvltle Centre, NY 11570

(516) 764-2575

CIRCLE 15 O N READER SERVICE CARD

NS-575 signal averager is a complete signal digitalizing system capable of performing signal averaging and multichannel scaling experiments, pulse height analysis and voltage, frequency, latency, and time distribution histograms. The digital memory address capacity is 1024, 2048, or 4096 channels. Other features are a built-in oscilloscope, digital display, and provision for a variety of plug-in modules. The 1024 channel address instrument costs $7450. Northern Scientific, Inc. 608836-6511 408

Willey 318. Take the Willey 318 Total Reflectance Infrared Spectrophotometer across the entire 2-20 micron range. Make both specular and diffuse reflectance measurements with this accurate true double beam spectrophotometer. See the ben efits of the scanning Michelson interferometer's better signal-to-noise ratio. Besides

greater

measurement

speed,

this method offers orders of magnitude increase in sensitivity over prism or

M500 image converter for infrared and ultraviolet light extends the range of image perception from the visible spectrum (400 to 750 nm) to the ir, from 750 to 1200 nm, and for the ultraviolet, 300 to 400 nm. In principle, the image converter tube picks up the invisible portion of the spectrum on an ir-sensitive or uv-sensitive transparent cathode layer, converts the lightbeam into an electron beam which is focused electronically onto a fluorescent screen. The lightbeam from the fluorescent screen can be viewed through a