Photodegradation rate constants for anthracene and pyrene are similar in/on ice and in aqueous solution Ted Hullar, Danielle Magadia, and Cort Anastasio Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.8b02350 • Publication Date (Web): 25 Sep 2018 Downloaded from http://pubs.acs.org on September 28, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 27
Environmental Science & Technology
1
Photodegradation rate constants for anthracene and pyrene are similar in/on ice and in
2
aqueous solution
3
Ted Hullar1, Danielle Magadia1,2, and Cort Anastasio1, *
4
1
5 6 7
Department of Land, Air and Water Resources, University of California, Davis, One
Shields Avenue, Davis, CA 95616, USA 2
Now at California Department of Food and Agriculture, 3292 Meadowview,
Sacramento, CA 95832
8
*
9
Abstract
10
Corresponding author,
[email protected], (530) 754-6095
Snowpacks contain a variety of chemicals, including organic pollutants such as toxic
11
polycyclic aromatic hydrocarbons (PAHs). While PAHs undergo photodegradation in snow and
12
ice, the rates of these reactions remain in debate. Some studies report that photochemical
13
reactions in snow proceed at rates similar to those expected in a supercooled aqueous solution,
14
but other studies report faster reaction rates, particularly at the air-ice interface (i.e., the quasi-
15
liquid layer, or QLL). In addition, one study reported a surprising non-linear dependence on
16
photon flux. Here we examine the photodegradation of two common PAHs, anthracene and
17
pyrene, in/on ice and in solution. For a given PAH, rate constants are similar in aqueous
18
solution, in internal liquid-like regions of ice, and at the air-ice interface. In addition, we find the
19
expected linear relationship between reaction rate constant and photon flux. Our results indicate
20
that rate constants for the photochemical loss of PAHs in, and on, snow and ice are very similar
21
to those in aqueous solution, with no enhancement at the air-ice interface.
22 23
ACS Paragon Plus Environment
Environmental Science & Technology
24 25
TOC Art
26 27 28
1.0 Introduction Snow contains a wide range of chemical compounds, which can be transformed through a
29
variety of mechanisms, including photochemical reactions, that alter the composition of the
30
snowpack. In polar regions, snowpacks are an important location for chemical reactions,
31
especially photochemical reactions, which can occur throughout the photic zone, approximately
32
the top several 10s of cm of the snowpack 1-3. Photochemical transformations of inorganic
33
compounds, such as the formation of NOx from nitrate photolysis or hydroxyl radical from
34
hydrogen peroxide photolysis, are important in polar snowpacks 4-8. Reactions of organic
35
compounds are also significant 9-12, frequently leading to more volatile components that can be
36
released from the snowpack. While a large variety of organic compounds have been found in
37
snowpacks 13-16, the chemical transformations and ultimate fate of these materials remains poorly
38
understood.
39
Chemicals in snow can be present in one or more of three different reservoirs: a quasi-
40
liquid layer (QLL) at the air-ice interface, in liquid-like regions (LLRs) within the ice (e.g., at
41
grain boundaries), and in the case of smaller molecules, within the bulk ice itself 7, 17-19. Solute
42
location in the snowpack, while poorly understood 1, 21, is significant for several reasons. For
43
example, chemicals present in QLLs can more easily partition into interstitial air in the snowpack
44
and subsequently to the atmosphere. Perhaps most intriguingly, some studies have found that
45
photoreaction rate constants can be enhanced in, and especially on, ice. For several PAHs,
46
photodegradation rate constants are reported to be 1.3 – 5.0 times faster in LLRs and 6.3 – 9.2
47
times faster in QLLs compared to rate constants in aqueous solution 22-25. In addition, for
ACS Paragon Plus Environment
Page 2 of 27
Page 3 of 27
Environmental Science & Technology
48
benzene, toluene, ethylbenzene, and xylene, photodegradation was observed in LLRs and QLLs,
49
but not in aqueous solution 26, 27. These results suggest QLLs and LLRs may be a distinct
50
reaction environment 22-27. In contrast, Ram and Anastasio 28 found that PAH photodegradation
51
rate constants in ice LLRs were similar to rate constants in aqueous solution. Further
52
complicating our understanding of organic reactions in ice, one study 24 reported that
53
photodegradation rate constants of PAHs at the air-ice interface are independent of photon flux
54
above a very low threshold. This finding is surprising and contrasts with the expected linear
55
dependence of the rate constant on photon flux under most environmental conditions.
56
There are several possible explanations for reaction rate constant differences in these
57
studies. First, differences in preparation method, usually intentional but sometimes inadvertent,
58
can have significant and sometimes unexpected impacts on solute location in laboratory sample
59
locations 21. If the air-ice interface or LLRs are different reaction environments than aqueous
60
solution, photodegradation rates may be different in each compartment, as found in some studies.
61
Second, the photodegradation rate constant depends on photon flux, which can vary within a
62
snowpack, with the surface snow actinic flux up to four times greater than the clear-sky actinic
63
flux 29. In order to accurately measure differences in photodegradation rate constants in the
64
laboratory, the local actinic flux must be measured, although this is not always done. McFall and
65
Anastasio 30 recently showed that solute location and sample container can have significant
66
impacts on local actinic flux, potentially biasing experimental results if photon fluxes are not
67
measured. Third, several studies 26, 31, 32 have found that light absorbance by some compounds in
68
QLLs and/or LLRs may red-shift slightly relative to aqueous solution, which would allow more
69
photons to be absorbed and therefore result in faster decay, although other studies did not find
70
red shifts in other compounds 33, 34. Finally, compounds present in QLLs and LLRs can
71
aggregate or form crystals 20, 31, 33, 35, which may change their chemical properties and alter the
72
kinetics of photodecay.
73
In this work we investigate the photodegradation rate constants of two common PAHs,
74
anthracene and pyrene, in laboratory ice samples prepared using several freezing methods to
75
preferentially place the solutes into either QLLs or LLRs. We have two main goals: (1) evaluate
76
the significance of reaction location on photodegradation rate constants and (2) determine the
ACS Paragon Plus Environment
Environmental Science & Technology
77
dependence of anthracene photodegradation rate constant on photon flux. We also look at the
78
impacts of solution ionic strength and sample exposure to laboratory air on photodegradation.
79
2 Methods
80
2.1 Materials
81
Acetonitrile (HPLC grade) was from Acros. Anthracene (ANT, 99%), pyrene (PYR,
82
99%), 2-nitrobenzaldehyde (2NB, 98%), and sodium chloride (NaCl, 99%) were from Sigma
83
Aldrich. High purity water (MQ) was from house-treated R/O water that was run through a
84
Barnstead International DO813 activated carbon cartridge and then a Millipore Milli-Q Plus
85
system (> 18.2 MΩ cm).
86
2.2 Sample preparation
87
We used two different containers for our samples: 2 mL screw-top HPLC autosampler
88
glass vials (12 mm outside diameter, 32 mm overall height) with plastic caps containing PTFE-
89
lined septa (Fisher Scientific) or 1.6 mL glass beakers, custom made by cutting off the threads
90
and neck of 2 mL glass vials. To minimize contamination with the beakers, we sealed them with
91
a piece of polyethylene film (Saran Wrap, Dow Chemical) secured with an O-ring.
92
We prepared four types of samples: aqueous, freezer, liquid nitrogen (LN2), and vapor
93
deposited (VD) (Figure 1). We prepared aqueous samples by first using a vapor deposition
94
apparatus (section 2.3) to bubble either ANT (for 10 minutes) or PYR (60 minutes) into 50 mL
95
of MQ in a 100 ml glass bottle to make a working solution of PAH with a concentration of ~10
96
nM. We used this solution as prepared for aqueous illumination samples. We made Freezer
97
samples by freezing 800 µL aliquots of working solution in a laboratory freezer (–20 oC). We
98
prepared LN2 samples by first adding 800 µL of working solution to a beaker or vial and then
99
placing the beaker or vial in a container of liquid nitrogen deep enough to just reach the liquid
100
level of sample in the beaker. Freezing time was typically less than 60 seconds. Based on
101
imaging work with similarly prepared samples containing CsCl 21 PAHs in our Freezer and LN2
102
samples are predominantly in liquid-like regions of the ices. VD samples were prepared by first
103
freezing 800 µL of MQ water in a beaker or vial at –20 oC and then depositing PAH to the ice
104
surface as described in the next section.
ACS Paragon Plus Environment
Page 4 of 27
Page 5 of 27
105 106
Environmental Science & Technology
2.3 Vapor deposition We used a custom-made apparatus to vapor deposit ANT and PYR to the surface of ice
107
samples (section 2.2). To make this apparatus (Figure S1), we first filled a 9 cm long piece of
108
1/16” ID Teflon tubing with either ANT or PYR; we used separate tubes for the two PAHs. The
109
ends of the tubes were closed with fittings containing stainless steel frits to constrain the solid
110
PAH. A 30-cm piece of 1/16” ID (1/8” OD) Teflon tubing downstream of the PAH-containing
111
tubing was threaded through the narrow end of a 5 mL, 10 cm long, polypropylene pipette tip,
112
with the unattached tubing end recessed 1 cm from the wider end of the pipette tip. We drilled
113
four 3 mm holes 4 cm from the wide end of the pipette tip to vent the nitrogen gas. The other
114
end of the PAH-containing tubing was attached to a nitrogen tank (99.998%, Praxair). To vapor
115
deposit PAH to the ice, we used a nitrogen flow rate of 0.1 liter per minute and placed the wide
116
end of the pipette tip over the sample container, with an interior ridge on the pipette tip resting
117
on the rim of the sample container. The nitrogen stream (containing either ANT or PYR)
118
impinged on the ice surface, depositing the PAH. During deposition the sample container was
119
placed in a freeze chamber at –20 oC and the tip of the apparatus was held over each ice sample
120
for 30 (ANT) or 60 seconds (PYR).
121
The amount of chemical actually deposited to the ice surface for VD samples varied
122
somewhat during each experimental day, with relative standard deviations (RSD, i.e., σ/mean) of
123
melted solution concentrations ranging from 5 to 15 %. Additionally, the average PAH amount
124
deposited varied from day to day, likely due to changes in the porosity of the solid PAH and in
125
laboratory temperature.
126
2.4 Sample illumination and chemical analysis
127
Samples were held in a custom-built freeze chamber (Paige Instruments) set at 5 oC
128
(aqueous samples) or –10 oC (frozen samples) and illuminated for 1 to 5 hours with a 1000-W
129
Xe lamp. The output of the lamp was filtered to simulate polar sunlight using a dichroic cold
130
mirror (to transmit 300-500 nm light but remove other wavelengths to reduce sample heating)
131
and an air mass 1.5 filter (Sciencetech) 36. Beakers were illuminated upright while being held in a
132
plastic lattice grid. Vials were illuminated horizontally in the machined grooves of a polished
133
aluminum plate (Figure S2) 28. We removed samples at periodic intervals for chemical analysis.
ACS Paragon Plus Environment
Environmental Science & Technology
134
Dark samples were covered with aluminum foil and placed in the illumination chamber along
135
with illuminated samples.
136
We measured PAH concentrations using a Shimadzu HPLC with a SIL-20A HT
137
autosampler, LC-20AB pump, and SPD-M20A photodiode array detector with a Thermo
138
Scientific BetaBasic-18 250 mm × 3 mm diameter column (5 µm particle size). We used an
139
eluent of 80:20 acetonitrile:MQ water at a flow rate of 0.700 mL min–1 and a detection
140
wavelength of 250 nm (ANT) or 335 nm (PYR). We analyzed all samples in the same container
141
used for sample illumination. Frozen samples were melted prior to analysis. For samples in
142
beakers, the polyethylene film cover and O-ring were removed (since the film might clog the
143
autosampler needle) and replaced with aluminum foil formed tightly around the beaker opening
144
to prevent evaporation or contamination.
145
2.5 Actinometry
146
We used 2-nitrobenzaldehyde (2NB), a chemical actinometer, to normalize for
147
differences in photon fluxes between samples and sample treatments 28, 37. On each experiment
148
day we prepared 2NB samples with the same volume, freezing method, and sample container as
149
the corresponding PAH sample. A stock of 10 µM 2NB was stored in the refrigerator and used
150
for aqueous, freezer, and LN2 experiments. Vapor deposition 2NB samples were prepared in the
151
same manner as VD PAH samples, using a separate 2NB vapor deposition apparatus. We then
152
illuminated the 2NB samples at a reference position (e.g., “B2” for vertically illuminated
153
beakers) in our illumination system for times ranging from 0 to 150 s.
154
We illuminated each 2NB sample on each day using the same HPLC as for the PAH
155
analyses, with an eluent of 60:40 acetonitrile:MQ water at a detection wavelength of 258 nm. To
156
determine the original deposited 2NB concentration in vapor-deposited samples, 2NB was
157
analyzed using an acidic (pH 2) eluent of 60:40 acetonitrile:MQ water so that we could measure
158
concentrations of both 2NB and its only photoproduct, nitrosobenzoic acid (NBA), using a
159
detection wavelength of 277 nm 30. Relative standard deviations for VD 2NB concentrations
160
deposited on a given day ranged from 9 to 19 %.
161
Once analyzed, we calculated the j2NB value from a linear regression of
ACS Paragon Plus Environment
Page 6 of 27
Page 7 of 27
Environmental Science & Technology
[2NB] ln = − (1) [2NB]
162
where [2NB]t and [2NB]0 are the concentrations at times t and 0, respectively. Because the
163
actinic flux in our illumination system varies slightly between illumination positions, we also
164
performed a “mapping” to quantify how illumination varies with position: on a single day we
165
measured j2NB in aqueous solution in the reference position (e.g., B2) and at each other position
166
(x). The ratio of these values is the correction factor F2NB, x , i.e., the ratio of photon flux at a
167
given sample position relative to the reference position 28: , =
168
, (2) ,
On a given PAH experiment day we measured j2NB in the B2 reference position and then used
169
the correction factors at every other sample position (Table S1) to account for variations in
170
actinic flux across the series of samples (section 2.6).
171
2.6 Determining rate constants for PAH loss
172
We determined PAH photodegradation rate constants (jPAH) following the same general
173
approach found in Ram and Anastasio 28. For each experiment, we first illuminated the samples
174
(or placed the samples in the illumination system under aluminum foil for dark controls) and
175
then analyzed them to determine the PAH concentration (section 2.4). For a given experiment
176
we used the slope of the natural logarithm of the ratio of the measured concentration at each
177
illumination time t, [PAH]t, to the initial concentration, [PAH]0, in conjunction with the photon
178
flux correction factor for each sample position (section 2.5) to determine the photodegradation
179
rate constant, jPAH: [] ln , = − (3) []
180
We followed a similar procedure for dark controls to determine the rate constant for dark loss
181
(k’PAH, dark), without applying any correction factor for spatial variations in actinic flux. In those
182
cases where there was loss of PAH in the dark samples, we corrected the measured jPAH by
183
subtracting k’PAH, dark to give the dark-corrected photodegradation rate constant jPAH, exp. Finally,
184
to normalize the results to daily differences in photon flux, we divided jPAH, exp by the measured
ACS Paragon Plus Environment
Environmental Science & Technology
185
daily j2NB value for the same sample preparation method to give the photon flux-normalized rate
186
constant, j*PAH: "#$,%&' ∗ = "#$ (4)
187
3 Results and Discussion
188
3.1 Actinometry and example illumination experiment
189
Because our different sample preparation methods may lead to variations in local photon
190
flux, which affects the photodegradation rate, we measured the 2-nitrobenzaldehyde photolysis
191
rate constant (j2NB) for each sample type on each experiment day as a proxy for photon flux.
192
Figures 2a and 2b show the j2NB values measured for each anthracene illumination experiment
193
conducted under our four experimental conditions (aqueous, freezer, LN2, and vapor deposition)
194
in vertically and horizontally illuminated beakers, respectively. By measuring j2NB we can
195
normalize the PAH photodegradation rate constants to account for varying photon flux in each
196
experimental condition. As seen in Figures 2a and 2b, actinic fluxes within each treatment vary
197
somewhat from day to day, with RSD values of 13, 16, 17, and 21% for vertically-illuminated
198
aqueous, freezer, LN2, and VD samples, respectively; for horizontally-illuminated samples, RSD
199
values are lower (4, 3, 3, and 14%, respectively). These differences are likely caused by
200
variations in lamp output and sample preparation. There is generally good agreement of j2NB
201
values within a particular sample type for each illumination orientation, as well as across sample
202
types, consistent with McFall and Anastasio 30, who found sample container and preparation
203
method can create modest (< 50%) but statistically significant differences in j2NB values.
204
However, while differences within the vertically- or horizontally-illuminated samples are
205
modest, we see larger differences between these two approaches. Figure 2c shows the ratio of
206
the average horizontally- to vertically-illuminated j2NB value for each sample treatment. For
207
aqueous, freezer, and LN2 samples, j2NB values in the horizontally illuminated samples are
208
approximately 3 times larger than in vertically illuminated samples. This is likely because the
209
polished aluminum sample holder reflects more light onto the horizontal samples than the dull
210
copper plate does for the vertical samples. For vapor deposited samples, however, j2NB values
211
are only approximately two times greater for horizontal illumination compared to vertical
212
illumination. In this case, the 2NB was deposited as a layer on top of the frozen water ice
ACS Paragon Plus Environment
Page 8 of 27
Page 9 of 27
Environmental Science & Technology
213
surface. When turned horizontally, this layer would be the thin side of a “disk” relative to the
214
light source, reducing its effective cross-section to the light beam and resulting in a lower
215
calculated j2NB value.
216
Figure 3 shows a typical illumination experiment, where samples of a solution of ANT
217
were frozen in sealed glass vials in a laboratory freezer and illuminated horizontally. Dark
218
controls show very little loss, probably attributable to volatilization, with a measured rate
219
constant (k’ANT, dark ± 1 SE) of 0.0022 ± 0.0009 s–1 (R2 = 0.67). ANT concentrations in
220
illuminated samples, however, show that photodegradation is much faster than dark loss, with a
221
calculated photodecay rate constant (jANT ± 1 SE) of 0.024 ± 0.0015 s–1 (R2 = 0.96).
222
3.2 ANT photodegradation rate constants with varying sample orientation
223
As described in section 2.4, we used two methods for illumination experiments: samples
224
in beakers illuminated vertically, i.e., through the top (diagram Figure 4b, photograph Figure
225
S2a), and samples in capped vials illuminated horizontally, i.e., through the side (diagram Figure
226
4d, photograph Figure S2b).
227
Figure 4a compares the ANT illumination experiments for each sample preparation
228
method, with all samples illuminated vertically in beakers. Rate constants are normalized to the
229
j2NB value measured for each experimental day. Here, we see no evidence of faster anthracene
230
photodegradation at the air-ice interface (i.e., for vapor deposited samples) compared to aqueous
231
solution, as was suggested by some previous studies 22-25: in fact, the vapor deposited sample
232
mean rate constant is 21 % lower than the aqueous mean, although the difference is not
233
statistically significant. Applying a single-factor ANOVA test shows that the means of all four
234
sample treatments for each illumination orientation are not the same. Applying the Tukey-
235
Kramer test for multiple comparisons (P < 0.05) shows two sample treatment pairs had the same
236
mean: aqueous and VD, and freezer and LN2. Sample preparation therefore appears to have a
237
small effect on j*ANT, with solutions frozen with a laboratory freezer or liquid nitrogen having a
238
j2NB-normalized photodegradation rate constant approximately 40 or 55% faster than aqueous
239
samples, respectively. Variability within each sample preparation method, as measured by RSD,
240
is 15, 18, 7, and 24% for the solution, freezer, LN2, and VD samples, respectively. Our
241
maximum VD ANT concentration (70 nM) corresponds to a surface loading of 1.1 ×1013
242
molecules cm–2, or roughly equal to a monolayer surface coverage if the ANT was spread evenly
ACS Paragon Plus Environment
Environmental Science & Technology
243
across the surface 23, 38; all other VD concentrations were lower, indicating sub-monolayer
244
conditions.
245
Comparing our results here to previous work requires an understanding of whether
246
solutes are in LLRs or at the air-ice interface. Some previous studies have crushed ice cubes into
247
granules to study compounds at the air-ice interface, stating that the crushing process increases
248
the surface area to volume ratio sufficiently to expose much of the (previously LLR-residing)
249
solute at the air-ice interface and that the increased surface area to volume ratio provides a
250
mechanism to study photolysis at the air-ice interface 24, 25, 27. While we agree that increasing the
251
surface area to volume ratio will increase the fraction of solute present at the air-ice interface, a
252
mathematical evaluation suggests that even in a finely ground powder most of the ice volume is
253
not in contact with the surface air, and that a uniformly distributed solute would be found almost
254
exclusively within the granule. Based on our evaluations of this sample preparation approach
255
(Supplemental section S1), we have chosen to identify the solute location in crushed granules as
256
LLRs, rather than at the air-ice interface as previously claimed.
257
Our finding that ANT at the air-ice interface is not more photochemically reactive than
258
anthracene in solution is contrary to the one previous result showing an enhancement (relative to
259
solution) of a factor of 6.2 23. Similarly, while past work reported that rate constants for ANT
260
photodegradation within ice cubes or granules (for solutes presumably in LLRs) are faster by
261
factors of 1.3 – 5.0 times compared to in solution 22-25, we see only a 40% increase in the LLR
262
(Freezer) samples compared to solution (Figure 4a). The faster reaction rate constants in these
263
past works could be partially explained by higher local photon fluxes, which were not measured.
264
Using 2NB as a chemical actinometer to evaluate photon fluxes in crushed ice samples, McFall
265
et al. 30 found a 1.8 ± 0.1 enhancement of photon flux relative to aqueous solution.
266
Figure 4c also presents ANT photodegradation data, but for samples prepared in capped
267
vials and illuminated horizontally, rather than the vertically-oriented beakers of Figure 4a. All
268
the horizontally illuminated j2NB-normalized rate constants were very similar: ANOVA indicates
269
no significant difference between the average rate constants for any of the sample preparations.
270
This is generally consistent with the vertically-illuminated ice samples, although the LLR
271
samples showed a modest rate constant enhancement of up to 55% relative to solution. Thus the
272
horizontally illuminated samples give additional evidence that anthracene at the air-ice interface
ACS Paragon Plus Environment
Page 10 of 27
Page 11 of 27
Environmental Science & Technology
273
is not significantly more photoreactive than ANT in solution. They also suggest that the modest
274
enhancement seen in the vertically-illuminated LLR samples in Figure 4a might not be real.
275
However, it is surprising that the dark-corrected and j2NB -normalized rate constants for
276
ANT photodecay (i.e., j*ANT) for the horizontal samples are lower than values from samples
277
illuminated vertically in beakers (Figures 4 and S3). To understand these differences, we
278
examine both components of j*ANT: 1) the values for jPAH, exp, the anthracene photodegradation
279
rate constants prior to photon-flux normalization (but after dark correction), and 2) the j2NB
280
values. First, Figures S4a and S4b present jPAH, exp values for samples illuminated vertically and
281
horizontally, respectively, while Figure S4c shows the ratio between these rate constants for each
282
sample treatment. While there is some variation in jANT, exp for each sample preparation method,
283
the vertical and horizontal results are roughly equivalent. However, this result is different than
284
the j2NB results (Figure 2), which show 2-3-fold higher photon fluxes in the horizontal samples
285
compared to the corresponding vertical samples. These higher photon fluxes should result in
286
higher photodegradation rate constants for the horizontally illuminated ANT samples, but this is
287
not seen in Figure S4c. One possible explanation for the apparent discrepancy is that the
288
horizontal samples were illuminated through the glass walls of the vials, while the vertical
289
samples were illuminated through a much thinner sheet of polyethylene film. Figure S5 shows
290
that glass vials pass very little light below 300 nm, where the polyethylene film passes most of
291
the incident light. But Figures S6a and S6b show that a significant fraction of ANT light
292
absorbance in our system occurs around 250 nm, while 2NB absorbance is more widely
293
distributed. While the j2NB results may be accurately reflecting an increased photon flux in the
294
vials relative to beakers at wavelengths above 300 nm, the quantum yield for ANT
295
photodegradation may be significantly greater around 250 nm than at longer wavelengths,
296
resulting in similar photodegradation rate constants in vertically illuminated beakers and
297
horizontally illuminated vials. While several studies have examined wavelength-dependent
298
quantum yields for PAHs in aqueous solution at wavelengths greater than 300 nm 39-41,only one
299
measured quantum yields below that value, at 254 nm 42. For the single compound examined at
300
wavelengths both above and below 300 nm, phenanthrene, the quantum yield was approximately
301
50% faster at 313 nm than 254 nm. While this finding does not support our explanation of the
302
ANT results seen, further research would be needed to determine the true wavelength
303
dependence of ANT quantum yield. Despite the differences in the measured photodegradation
ACS Paragon Plus Environment
Environmental Science & Technology
304
rate constants between horizontally- and vertically-illuminated samples, both sets of data support
305
the conclusion that photodegradation rate constants are similar in aqueous solution, LLRs, and at
306
the air-ice interface. Our finding that anthracene photodegradation is similar in aqueous solution and at the
307 308
air-ice interface contradicts previous work 22-25, which found much faster anthracene
309
photodegradation at the air-ice interface and in LLRs, relative to in solution. While we have not
310
measured photoproducts, our kinetic results suggest (but of course do not prove) that the reaction
311
environment and photodegradation mechanism at the interface, as well as in liquid-like regions
312
of ice, are broadly similar to aqueous solution, at least for this PAH. However, our small but
313
statistically significant enhancement in ANT photodecay in Freezer and LN2 samples compared
314
to aqueous solution or vapor deposited samples (Figure 4a) suggests additional processes might
315
impact the overall chemical reaction rate constant, although we do not see this in the
316
horizontally-illuminated samples (Figure 4c). In both the Freezer and LN2 samples, reactants
317
should be in highly concentrated LLRs within the ice matrix 21, 43. This concentration effect can
318
increase the steady-state concentration of oxidants such as singlet oxygen 43-45, which (in
319
solution) is both formed by PAHs and acts as a sink for PAHs 46. It is possible that such an
320
effect is enhancing PAH loss in some ice cases.
321
3.3 Pyrene experiments
322
We next performed experiments using pyrene (PYR) instead of anthracene. Recent work
323
has reported some small enhancements in PYR photodecay for ice samples made by freezing 100
324
nM pyrene solution into 10 ml pellets and illuminating at –15 °C using the output of a 450 W arc
325
lamp filtered through water. For illuminated pellets (where solutes are expected to be in LLRs)
326
the rate constant was 1.9 (± 0.45, 1 SD) times faster than in solution at 23 °C, while pellets
327
crushed to 2 mm spheres had an enhancement of 1.3 (± 0.52, 1 SD) relative to solution 25. In the
328
latter case the authors suggested that PYR would be preferentially found at the air-ice interface
329
25
330
also had higher average photon fluxes as a result of increased reflection 30.
331
, although we expect that the solutes would still be in LLRs. The crushed samples probably
In Figure 5 we show results for our experiments using pyrene in vertically illuminated
332
beakers under conditions identical (except for PAH) to Figure 4a. While we see a slight (~10%)
333
enhancement in vapor-deposited samples relative to aqueous samples, neither of the mean rate
ACS Paragon Plus Environment
Page 12 of 27
Page 13 of 27
Environmental Science & Technology
334
constants in/on ice are statistically different from the solution value. As with ANT, and again in
335
contrast with previous work, we see no evidence for an enhancement in pyrene photodegradation
336
at the air-ice interface, or in liquid-like regions of ice, compared to aqueous solution.
337
Ram and Anastasio 28 also examined PYR photodegradation, in this case in slowly frozen
338
ice (where PYR should be in LLRs) illuminated in horizontally-oriented quartz tubes in/on the
339
same aluminum sample holder used in our current work for horizontal samples. They measured
340
a rate constant for photodegradation at –10 °C, normalized to noon conditions at Summit
341
Greenland on the summer solstice, of 28 × 10–5 ± 3 × 10–5 (± 1 SE) s–1. Converting units and
342
correcting for the Summit summer j2NB value used in Ram and Anastasio (2.2 × 10 –2 s–1) gives a
343
j2NB-normalized rate constant of 0.76 ± 0.11 min–1/s–1 for this past LLR work. In comparison,
344
our average Freezer (LLR) result in vertically-illuminated samples of frozen PYR solution is 1.3
345
± 0.3 (± 1 σ) min–1/s–1 (Figure 5). We note Ram and Anastasio’s sample illumination method
346
was different than ours, employing quartz tubes illuminated horizontally, and could account for
347
the differing values. But it is interesting that for both pyrene (comparing results from Ram and
348
Anastasio to ours here) and anthracene the photon-flux-normalized rate constant was greater in
349
vertically-illuminated samples.
350
Using their experimental results – combined with information from previous studies of
351
pyrene photodecay in aqueous solution – Ram and Anastasio 28 estimated an activation energy
352
(Ea) for pyrene photodegradation in LLRs of 30 ± 4 kJ mol–1 (which was incorrectly listed as
353
negative in their paper). Based on this value, the rate constant j*PYR should be smaller by a
354
factor of two in/on ice at – 10 °C compared to in solution at 5 °C. Instead, we find
355
photodegradation rate constants are roughly equivalent in solution and ice (Figure 5). Unlike
356
Ram and Anastasio, we measured photodegradation for both frozen and aqueous samples using
357
the same experimental system; since this approach is better, our results suggest that pyrene
358
photodegradation has a very small temperature dependence. Using our aqueous and frozen
359
(Freezer) rate constants we estimate that the apparent activation energy for PYR photodecay is 9
360
± 15 kJ mol–1, i.e., that this reaction is independent of temperature.
361
3.4 Rate constant dependence on photon flux
ACS Paragon Plus Environment
Environmental Science & Technology
362
One study reported that the photodegradation rate constant of anthracene is largely
363
independent of photon flux, with additional light past a certain intensity causing no increase in
364
photodegradation 24. This is unexpected. Because the photodegradation rate constant should be
365
directly proportional to the rate of photon absorption by a chemical, we expect photodegradation
366
rate constants to be proportional to photon flux. To test this, we measured rate constants for
367
PAH loss as a function of photon flux. To reduce the light intensity from our standard condition,
368
we inserted either 2 or 4 galvanized steel mesh screens (with approximately 1 mm grid spacing)
369
into the light path of the illumination system.
370
Figure 6 shows our results for jANT (here, not dark corrected) versus the j2NB value
371
measured in each experiment for solution and ice samples. Results from the previous study 24,
372
which showed fast reactivity and a weak dependence on photon flux, are bounded by the narrow
373
vertical box along the y axis; to better visualize this past data, we also present this figure in a log-
374
log plot in Figure S7. As expected, our data shows a linear relationship between the
375
photodegradation rate constant and photon flux for all three of the sample types tested,
376
contradicting the previous work. Y-intercepts for all three sample treatments are statistically
377
indistinguishable from zero, although there does appear to be dark loss in some samples. The
378
slopes of the regression lines for VD and aqueous samples are statistically indistinguishable,
379
while the slopes for the aqueous and freezer lines are different; the slopes for the freezer and VD
380
lines are indistinguishable. For each sample treatment, the regression line slope in Figure 6
381
corresponds closely to and is statistically indistinguishable from the average photon flux-
382
normalized rate constant determined with full illumination (without metal screens) presented in
383
Figure 4a.
384
Taken together, these results suggest that photodegradation in all sample treatments
385
proceeds by a similar mechanism, but product measurements are needed to better constrain this.
386
In addition, we note that the photon fluxes in our work are dramatically higher than those
387
reported in the previous work, and are closer to (though still lower than) values representative of
388
midday summer conditions at Summit, Greenland (with a calculated j2NB value of 0.022 s–1) 28.
389
Our typical experimental j2NB value was 0.0020 s–1, corresponding to an incident photon flux of
390
1.8 × 1015 photons cm–2 s–1 over a wavelength range of 291 to 400 nm. On the other hand,
391
Kahan et al. 24 report photon fluxes ranging from 1.1 ×1012 to 2.2 × 1013 photons cm–2 s–1,
ACS Paragon Plus Environment
Page 14 of 27
Page 15 of 27
Environmental Science & Technology
392
approximately 80-1600 times lower than our typical experimental photon flux and another factor
393
of 10 lower than summertime photon fluxes in polar regions.
394
3.5 Impact of solutes and exposure to lab air Because the total solute amount in an ice sample impacts the volumes of LLRs and QLLs
395 396
47-49
397
PAH photodegradation rate constants. As shown in Supplemental Figure S8, the presence of
398
NaCl tends to increase j*ANT for all sample preparation methods, including solution, but this
399
behavior does not correlate well with NaCl concentration. The lowest concentration of NaCl
400
used (0.02 M) gives results similar to solutions made in pure water, but at higher concentrations
401
(0.2 M and above), the reaction rate constant is often faster than pure-water values. The ratios of
402
the average j*ANT value for salt concentrations above 0.02 M relative to the average j*ANT for
403
NaCl concentrations equal to or below 0.02 M are 2.2, 1.8, and 2.2 for aqueous solution, frozen
404
solution, and vapor-deposited samples, respectively. It is unclear why higher total solute
405
concentrations would increase PAH photodegradation rates in aqueous solution, but the effect
406
might be due to trace impurities in the salt. For ice samples made from solutions containing
407
higher total solute concentrations, the volume of the QLL or LLR should be larger, and therefore
408
any reactive solutes should be less concentrated compared to ice made from solution containing a
409
lower initial total solute concentration. For first-order reactions, such as direct photolysis, we
410
would expect the same reaction rate constant regardless of salt concentration. But for second
411
order reactions, the addition of salt should decrease the measured pseudo-first-order rate constant
412
(e.g., 44). Instead, in Figure S8 for ANT photodecay we see a slight increase in the measured rate
413
constant with higher salt concentration, inconsistent with either expectation. Although this effect
414
seems consistent across sample types, we do not have an explanation. Interestingly, our results
415
are the opposite of those found in another study using harmine as the test compound and either
416
sodium chloride or sodium bromide to control total solute concentration, which showed slower
417
photodecay with increasing salt concentration 50.
418
, we also examined whether varying the concentration of sodium chloride (NaCl) affects
Finally, we also examined whether contaminants present in laboratory air might partition
419
to the air-ice interface of our frozen samples and enhance the rate of PAH photodecay by making
420
singlet molecular oxygen, which can react rapidly with PAHs 46. We have previously found that
421
small amounts of contaminants in solution get concentrated during freezing and can generate
ACS Paragon Plus Environment
Environmental Science & Technology
422
high concentrations of 1O2* during illumination 43. We suspect that a similar mechanism might
423
occur at the air-ice interface. To test this, we first made ice samples (in our homemade beakers)
424
and then exposed the samples to laboratory air while keeping the samples at –18 oC in a
425
temperature-controlled chamber with the lid raised approximately 1 cm above the top edge of the
426
chamber. After exposing the ice sample to lab air we vapor-deposited ANT onto the ice surface
427
and illuminated with simulated sunlight. As shown in Supplemental Figure S9, there is a general
428
trend toward higher rate constants for ANT loss for samples exposed to lab air: three of the five
429
exposed samples have higher photodegradation rate constants, with enhancements ranging from
430
1.3- to 4.0-fold compared to the average j*ANT value for samples not exposed to lab air.
431
However, the rate constants are generally noisy, the enhancement does not correlate with
432
exposure time, and experiments on the same day show different results. Thus, while we see
433
some evidence that gaseous contaminants can enhance the photodegradation of anthracene at the
434
air-ice interface, more work is be needed to quantify this effect.
435
4 Implications
436
Our results show no enhancement in photodegradation rate constants for anthracene or
437
pyrene at the air-ice interface compared to in aqueous solution. Further, we find either no
438
enhancement, or only small enhancements (40-55%), in LLRs relative to aqueous solution. This
439
is in contrast to previous results for anthracene and naphthalene 23. Further, our findings support
440
the expected relationship that photodegradation rate constants are proportional to photon flux;
441
this is also in contrast to previous work 24. The reasons for the difference in our current results
442
compared to previous work are unclear, but the anthracene photodegradation loss rate constants
443
normalized for photon flux are far greater in the Kahan et al. study 24 than measured here (and in
444
another study 28), suggesting loss mechanisms other than photodegradation might have been
445
important in past work. We also note that our methods here are different than used in previous
446
work: our lamp intensities were substantially higher (and more similar to ambient actinic flux),
447
our PAH concentrations were lower (and more similar to ambient snow levels), and a much
448
smaller fraction of our sample surface area was exposed to air. While it is difficult to assess the
449
individual significance of these methodological differences, they could contribute to the overall
450
difference in results.
ACS Paragon Plus Environment
Page 16 of 27
Page 17 of 27
Environmental Science & Technology
Overall, our current work suggests that the kinetics of PAH photochemistry in/on snow
451 452
and ice are very similar to kinetics in aqueous solution. While the presence of other contaminants
453
in environmental snows and ices might alter PAH kinetics (e.g., 22, 25), the puzzle of polar PAHs
454
is not that they decay more quickly in snow than expected, but the opposite: PAHs in snow have
455
longer-than-expected lifetimes, probably because they are embedded in light-absorbing particles
456
28
457
molecular oxygen can be enormously enhanced in ice samples compared to solution 18, 43, 45, our
458
finding that PAHs in ice and solution have similar lifetimes suggests that 1O2* is not an
459
important sink for ANT and PYR in the ice samples studied here.
460
Supporting information
461 462
Supporting information is available free of charge on the ACS Publications website at DOI: 10.1021/acs.est.??????.
463 464 465
. Finally, since previous work has found that the steady-state concentrations of singlet
PAH location in crushed ice granules, summary of previous work, diagrams and pictures of experimental equipment, details on some experimental results, Figures S1 – S9, and Tables S1 and S2 (PDF)
466
Acknowledgments
467 468
We thank the National Science Foundation for funding (ECS-1214121 and AGS-PRF 1524857) and Ricky Obregon for experimental assistance.
ACS Paragon Plus Environment
Environmental Science & Technology
469
Figures
470
471 472 473 474
Figure 1. Diagram of the four different sample preparation methods: aqueous solution, solution frozen in a laboratory freezer, solution frozen in liquid nitrogen, and PAH vapor-deposited to a water ice surface.
475
ACS Paragon Plus Environment
Page 18 of 27
Page 19 of 27
Environmental Science & Technology
476 477
478 479 480
481
482 483 484 485 486 487 488 489 490 491 492 493
Figure 2. a) 2-nitrobenzaldehyde photolysis rate constants (j2NB) for the vertical orientation of each of the four experimental conditions (aqueous solution, samples frozen in freezer, samples frozen in liquid nitrogen, and samples with 2NB deposited to the air-ice interface). Each bar is an individual actinometry experiment, ordered chronologically within a particular experimental condition. In each case the 2NB sample was illuminated in a glass beaker oriented vertically (i.e., with the long axis of the beaker parallel to the incident light). Individual error bars are ± 1 standard error. Shaded areas represent the mean value for each treatment (dark line) with 95% upper and lower confidence intervals (UCL and LCL) above and below. Sample treatments with statistically indistinguishable average rate constants (P < 0.05) are labelled with the same capital letter (“A”, “B”, etc.); treatments with different letters are statistically different. b) Identical to
ACS Paragon Plus Environment
Environmental Science & Technology
494 495 496 497
a), but for samples illuminated horizontally in 2 ml vials. c) Ratio of average horizontal to average vertical j2NB values for a given experimental condition, using the individual data points shown in Figures 2a and b. Error bars are 95% confidence intervals for each ratio.
498
499 500 501 502 503 504 505 506
Figure 3. Illumination experiment for anthracene ice samples in horizontally-oriented glass vials prepared in the freezer with an initial ANT concentration of 1 nM. Illuminated samples are given by filled blue diamonds, while open diamonds are dark control samples. Each data point is from an individual sample container (we illuminated two samples for each time point). The value for j2NB is 0.0067 s–1.
ACS Paragon Plus Environment
Page 20 of 27
Page 21 of 27
Environmental Science & Technology
507
b)
508
d)
509 510 511 512 513 514 515 516 517 518 519 520 521 522
Figure 4. Results of anthracene photodegradation experiments. a) Dark-corrected (and j2NBnormalized) ANT photodegradation rate constants (j*ANT) for vertically illuminated samples. Results are given in chronological order within each sample preparation method; each vertical bar indicates a separate experiment. Individual error bars are ± 1 standard error. Shaded areas represent the mean value for each treatment (dark line) with 95% upper and lower confidence intervals (UCL and LCL) above and below. Sample treatments with statistically different average rate constants (P < 0.05) are labelled with different capital letters. b) Schematic of the vertical illumination setup with a beaker covered with polyethylene film. c) Identical to a), but for horizontally illuminated samples. Means for all four sample preparation methods were statistically indistinguishable (P > 0.05). d) Horizontal illumination setup showing capped vial; see Figure S2c for a diagram of vials in the polished aluminum sample holder.
ACS Paragon Plus Environment
Environmental Science & Technology
523
524 525 526 527 528 529 530 531 532
Figure 5. Comparison of dark-corrected pyrene (PYR) photodegradation rate constants for vertically-oriented samples. Results are individual experiments given in chronological order within each sample preparation method. Individual error bars are ± 1 standard error. Shaded areas represent the mean value for each treatment (dark line) with 95% upper and lower confidence intervals (UCL and LCL) above and below. Means for all three sample types were statistically indistinguishable (P > 0.05).
ACS Paragon Plus Environment
Page 22 of 27
Page 23 of 27
Environmental Science & Technology
533 534
535 536 537 538 539 540 541 542 543 544 545 546 547 548
Figure 6. Dependence of the ANT photodegradation rate constant (jANT, not dark corrected) on the photon flux, measured with j2NB, using various sample treatments in vertically-oriented beakers. Each point indicates a separate experiment. For comparison, the lower range of the data reported in Kahan et al. 24 is delineated by the narrow grey rectangle on the upper left portion of the plot. Bars on our data points are ± 1 standard error, determined from propagated errors. For our three datasets, the slope ± 95% confidence interval (CI) is given on the graph. The corresponding y-intercept (min–1) ± 95% CI and R2 values are: -0.00053 ± 0.00077, 0.97; 0.00074 ± 0.0016, 0.95; and 0.0021 ± 0.0022, 0.97 for aqueous (red diamonds), freezer (blue squares), and VD (black triangles) samples respectively. None of the y-intercept values are statistically different from zero.
ACS Paragon Plus Environment
Environmental Science & Technology
549
References
550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592
1.
2. 3.
4.
5. 6. 7.
8.
9. 10. 11.
12. 13. 14.
Bartels-Rausch, T.; Jacobi, H. W.; Kahan, T. F.; Thomas, J. L.; Thomson, E. S.; Abbatt, J. P. D.; Ammann, M.; Blackford, J. R.; Bluhm, H.; Boxe, C.; Domine, F.; Frey, M. M.; Gladich, I.; Guzman, M. I.; Heger, D.; Huthwelker, T.; Klan, P.; Kuhs, W. F.; Kuo, M. H.; Maus, S.; Moussa, S. G.; McNeill, V. F.; Newberg, J. T.; Pettersson, J. B. C.; Roeselova, M.; Sodeau, J. R. A review of air-ice chemical and physical interactions (AICI): liquids, quasi-liquids, and solids in snow. Atmos. Chem. Phys. 2014, 14, (3), 1587-1633. Domine, F.; Shepson, P. B. Air-snow interactions and atmospheric chemistry. Science 2002, 297, (5586), 1506-1510. Grannas, A. M.; Jones, A. E.; Dibb, J.; Ammann, M.; Anastasio, C.; Beine, H. J.; Bergin, M.; Bottenheim, J.; Boxe, C. S.; Carver, G.; Chen, G.; Crawford, J. H.; Domine, F.; Frey, M. M.; Guzman, M. I.; Heard, D. E.; Helmig, D.; Hoffmann, M. R.; Honrath, R. E.; Huey, L. G.; Hutterli, M.; Jacobi, H. W.; Klan, P.; Lefer, B.; McConnell, J.; Plane, J.; Sander, R.; Savarino, J.; Shepson, P. B.; Simpson, W. R.; Sodeau, J. R.; von Glasow, R.; Weller, R.; Wolff, E. W.; Zhu, T. An overview of snow photochemistry: evidence, mechanisms and impacts. Atmos. Chem. Phys. 2007, 7, (16), 4329-4373. Beine, H. J.; Domine, F.; Simpson, W.; Honrath, R. E.; Sparapani, R.; Zhou, X. L.; King, M. Snow-pile and chamber experiments during the Polar Sunrise Experiment 'Alert 2000': exploration of nitrogen chemistry. Atmos. Environ. 2002, 36, (15-16), 2707-2719. Chu, L.; Anastasio, C. Quantum yields of hydroxyl radical and nitrogen dioxide from the photolysis of nitrate on ice. J. Phys. Chem. A. 2003, 107, (45), 9594-9602. Chu, L.; Anastasio, C. Formation of hydroxyl radical from the photolysis of frozen hydrogen peroxide. J. Phys. Chem. A. 2005, 109, (28), 6264-6271. Jacobi, H. W.; Bales, R. C.; Honrath, R. E.; Peterson, M. C.; Dibb, J. E.; Swanson, A. L.; Albert, M. R. Reactive trace gases measured in the interstitial air of surface snow at Summit, Greenland. Atmos. Environ. 2004, 38, (12), 1687-1697. Jacobi, H. W.; Annor, T.; Quansah, E. Investigation of the photochemical decomposition of nitrate, hydrogen peroxide, and formaldehyde in artificial snow. J. Photochem. Photobiol. A-Chem. 2006, 179, (3), 330-338. Dibb, J. E.; Arsenault, M. Shouldn't snowpacks be sources of monocarboxylic acids? Atmos. Environ. 2002, 36, (15-16), 2513-2522. Sumner, A. L.; Shepson, P. B. Snowpack production of formaldehyde and its effect on the Arctic troposphere. Nature 1999, 398, (6724), 230-233. Swanson, A. L.; Blake, N. J.; Dibb, J. E.; Albert, M. R.; Blake, D. R.; Rowland, F. S. Photochemically induced production of CH3Br, CH3I, C2H5I, ethene, and propene within surface snow at Summit, Greenland. Atmos. Environ. 2002, 36, (15-16), 2671-2682. Hutterli, M. A.; Rothlisberger, R.; Bales, R. C. Atmosphere-to-snow-to-firn transfer studies of HCHO at Summit, Greenland. Geophys. Res. Lett. 1999, 26, (12), 1691-1694. Grannas, A. M.; Shepson, P. B.; Filley, T. R. Photochemistry and nature of organic matter in Arctic and Antarctic snow. Glob. Biogeochem. Cycle 2004, 18, (1), GB1006. Grannas, A. M.; Hockaday, W. C.; Hatcher, P. G.; Thompson, L. G.; Mosley-Thompson, E. New revelations on the nature of organic matter in ice cores. J. Geophys. Res.-Atmos. 2006, 111, (D4), D04304.
ACS Paragon Plus Environment
Page 24 of 27
Page 25 of 27
593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638
Environmental Science & Technology
15. 16. 17.
18. 19.
20.
21. 22.
23. 24.
25.
26. 27. 28. 29. 30. 31.
32.
Satsumabayashi, H.; Nishizawa, H.; Yokouchi, Y.; Ueda, H. Pinonaldehyde and some other organics in rain and snow in central Japan. Chemosphere 2001, 45, (6-7), 887-891. Laniewski, K.; Boren, H.; Grimvall, A. Identification of volatile and extractable chloroorganics in rain and snow. Environ. Sci. Technol. 1998, 32, (24), 3935-3940. Barret, M.; Domine, F.; Houdier, S.; Gallet, J. C.; Weibring, P.; Walega, J.; Fried, A.; Richter, D. Formaldehyde in the Alaskan Arctic snowpack: Partitioning and physical processes involved in air-snow exchanges. J. Geophys. Res.-Atmos. 2011, 116, D00R03. Grannas, A. M.; Bausch, A. R.; Mahanna, K. M. Enhanced aqueous photochemical reaction rates after freezing. J. Phys. Chem. A. 2007, 111, (43), 11043-11049. Domine, F.; Albert, M.; Huthwelker, T.; Jacobi, H. W.; Kokhanovsky, A. A.; Lehning, M.; Picard, G.; Simpson, W. R. Snow physics as relevant to snow photochemistry. Atmos. Chem. Phys. 2008, 8, (2), 171-208. Ondruskova, G.; Krausko, J.; Stern, J. N.; Hauptmann, A.; Loerting, T.; Heger, D. Distinct Speciation of Naphthalene Vapor Deposited on Ice Surfaces at 253 or 77 K: Formation of Submicrometer-Sized Crystals or an Amorphous Layer. J. Phys. Chem. C 2018, 122, (22), 11945-11953. Hullar, T.; Anastasio, C. Direct visualization of solute locations in laboratory ice samples. Cryosphere 2016, 10, (5), 2057-2068. Malley, P. P. A.; Grossman, J. N.; Kahan, T. F. Effects of chromophoric dissolved organic matter on anthracene photolysis kinetics in aqueous solution and ice. J. Phys. Chem. A. 2017, 121, 7619−7626. Kahan, T. F.; Donaldson, D. J. Photolysis of polycyclic aromatic hydrocarbons on water and ice surfaces. J. Phys. Chem. A. 2007, 111, (7), 1277-1285. Kahan, T. F.; Zhao, R.; Jumaa, K. B.; Donaldson, D. J. Anthracene photolysis in aqueous solution and ice: Photon flux dependence and comparison of kinetics in bulk ice and at the air-ice interface. Environ. Sci. Technol. 2010, 44, (4), 1302-1306. Malley, P. P. A.; Kahan, T. F. Nonchromophoric organic matter suppresses polycyclic aromatic hydrocarbon photolysis in ice and at ice surfaces. J. Phys. Chem. A. 2014, 118, (9), 1638-1643. Kahan, T. F.; Donaldson, D. J. Benzene photolysis on ice: Implications for the fate of organic contaminants in the winter. Environ. Sci. Technol. 2010, 44, (10), 3819-3824. Stathis, A. A.; Hendrickson-Stives, A. K.; Kahan, T. F. Photolysis kinetics of toluene, ethylbenzene, and xylenes at ice surfaces. J. Phys. Chem. A. 2016, 120, (34), 6693-6697. Ram, K.; Anastasio, C. Photochemistry of phenanthrene, pyrene, and fluoranthene in ice and snow. Atmos. Environ. 2009, 43, (14), 2252-2259. Phillips, G. J.; Simpson, W. R. Verification of snowpack radiation transfer models using actinometry. J. Geophys. Res.-Atmos. 2005, 110, (D8), D08306. McFall, A. S.; Anastasio, C. Photon flux dependence on solute environment in water ices. Environmental Chemistry 2016, 13, (4), 682-687. Malongwe, J. K.; Nachtigallova, D.; Corrochano, P.; Klan, P. Spectroscopic properties of anisole at the air-ice interface: A combined experimental-computational approach. Langmuir 2016, 32, (23), 5755-5764. Kania, R.; Malongwe, J. K.; Nachtigallova, D.; Krausko, J.; Gladich, I.; Roeselova, M.; Heger, D.; Klan, P. Spectroscopic properties of benzene at the air-ice interface: A combined experimental-computational approach. J. Phys. Chem. A. 2014, 118, (35), 7535-7547.
ACS Paragon Plus Environment
Environmental Science & Technology
639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683
33.
34.
35.
36.
37.
38. 39.
40. 41. 42.
43.
44.
45.
46.
47. 48.
Krausko, J.; Malongwe, J. K.; Bicanova, G.; Klan, P.; Nachtigallova, D.; Heger, D. Spectroscopic properties of naphthalene on the surface of ice grains revisited: A combined experimental computational approach. J. Phys. Chem. A. 2015, 119, (32), 8565-8578. Matykiewiczova, N.; Kurkova, R.; Klanova, J.; Klan, P. Photochemically induced nitration and hydroxylation of organic aromatic compounds in the presence of nitrate or nitrite in ice. J. Photochem. Photobiol. A-Chem. 2007, 187, (1), 24-32. Heger, D.; Jirkovsky, J.; Klan, P. Aggregation of methylene blue in frozen aqueous solutions studied by absorption spectroscopy. J. Phys. Chem. A. 2005, 109, (30), 67026709. Hullar, T.; Anastasio, C. Yields of hydrogen peroxide from the reaction of hydroxyl radical with organic compounds in solution and ice. Atmos. Chem. Phys. 2011, 11, (14), 7209-7222. Galbavy, E. S.; Ram, K.; Anastasio, C. 2-Nitrobenzaldehyde as a chemical actinometer for solution and ice photochemistry. J. Photochem. Photobiol. A-Chem. 2010, 209, (2-3), 186-192. Mmereki, B. T.; Chaudhuri, S. R.; Donaldson, D. J. Enhanced uptake of PAHs by organic-coated aqueous surfaces. J. Phys. Chem. A. 2003, 107, (13), 2264-2269. Zepp, R. G.; Schlotzhauer, P. F., Photoreactivity of selected aromatic hydrocarbons in water. In Polynuclear Aromatic Hydrocarbons: Third International Symposium on Chemistry and Biology – Carcinogenesis and Mutagenesis, Jones, P. W.; Leber, P., Eds. Ann Arbor Science,: Ann Arbor, 1979; pp 141–158. Mill, T.; Mabey, W. R.; Lan, B. Y.; Baraze, A. Photolysis of polycyclic aromatic hydrocarbons in water. Chemosphere 1981, 10, (11-1), 1281-1290. Fasnacht, M. P.; Blough, N. V. Aqueous photodegradation of polycyclic aromatic hydrocarbons. Environ. Sci. Technol. 2002, 36, (20), 4364-4369. Beltran, F. J.; Ovejero, G.; Garciaaraya, J. F.; Rivas, J. Oxidation of Polynuclear Aromatic Hydrocarbons in water. 2. UV radiation and ozonation in the presence in the presence of UV radiation. Ind. Eng. Chem. Res. 1995, 34, (5), 1607-1615. Bower, J. P.; Anastasio, C. Measuring a 10,000-fold enhancement of singlet molecular oxygen (1O2*) concentration on illuminated ice relative to the corresponding liquid solution. Atmos. Environ. 2013, 75, 188-195. Bower, J. P.; Anastasio, C. Using singlet molecular oxygen to probe the solute and temperature dependence of liquid-like regions in/on ice. J. Phys. Chem. A. 2013, 117, (30), 6612-6621. Bower, J. P.; Anastasio, C. Degradation of organic pollutants in/on snow and ice by singlet molecular oxygen (1O2*) and an organic triplet excited state. Environ. Sci.-Process Impacts 2014, 16, (4), 748-756. Wilkinson, F.; Helman, W. P.; Ross, A. B. Rate constants for the detay and reactions of the lowest electronically excited singlet-state of molecular oxygen in solution - an expanded and revised compilation. J. Phys. Chem. Ref. Data 1995, 24, (2), 663-1021. Cho, H.; Shepson, P. B.; Barrie, L. A.; Cowin, J. P.; Zaveri, R. NMR investigation of the quasi-brine layer in ice/brine mixtures. J. Phys. Chem. B 2002, 106, (43), 11226-11232. Hudait, A.; Allen, M. T.; Molinero, V. Sink or swim: Ions and organics at the ice-air interface. J. Am. Chem. Soc. 2017, 139, (29), 10095-10103.
ACS Paragon Plus Environment
Page 26 of 27
Page 27 of 27
684 685 686 687 688
Environmental Science & Technology
49. 50.
Moussa, S. G.; Kuo, M. H.; McNeill, V. F. Nitric acid-induced surface disordering on ice. Phys. Chem. Chem. Phys. 2013, 15, (26), 10989-10995. Kahan, T. F.; Kwamena, N. O. A.; Donaldson, D. J. Different photolysis kinetics at the surface of frozen freshwater vs. frozen salt solutions. Atmos. Chem. Phys. 2010, 10, (22), 10917-10922.
689
ACS Paragon Plus Environment