Plasmoelectronic-Based Ultrasensitive Assay of Tumor Suppressor microRNAs Directly in Patient Plasma: Design of Highly Specific Early Cancer Diagnostic Technology Thakshila Liyanage, Adrianna N Masterson, Hector H. Oyem, Hristos Kaimakliotis, Hang Nguyen, and Rajesh Sardar Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.8b03768 • Publication Date (Web): 04 Jan 2019 Downloaded from http://pubs.acs.org on January 7, 2019

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Plasmoelectronic-Based Ultrasensitive Assay of Tumor Suppressor microRNAs Directly in Patient Plasma: Design of Highly Specific Early Cancer Diagnostic Technology Thakshila Liyanage,1 Adrianna N. Masterson,1 Hector H. Oyem,2 Hristos Kaimakliotis,3 Hang Nguyen,1 and Rajesh Sardar*,1,4 1Department

of Chemistry and Chemical Biology, Indiana University-Purdue University

Indianapolis, 402 N. Blackford Street, Indianapolis, Indiana 46202, United States 2School

of Chemistry, Newcastle University, NE1 7RU, United Kingdom

3Department

of Urology, Indiana University School of Medicine, 535 N. Barnhill Dr.

Indianapolis, Indiana 46202, United States 4Integrated Nanosystems Development Institute, Indiana University-Purdue University

Indianapolis, 402 N. Blackford Street, Indianapolis, Indiana 46202, United States

ACS Paragon Plus Environment

1

Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 32

ABSTRACT: It is becoming understood that microRNAs hold great promise for non-invasive liquid biopsies for screening for different types of cancer, but current state-of-the-art RT-PCR and microarray techniques have sensitivity limitations that currently restrict their use. Herein, we report a new transduction mechanism involving delocalization of photoexcited conduction electrons wavefunction of gold triangular nanoprism (Au TNP) in the presence of -ssDNA/microRNA duplexes. This plasmoelectronic effect increases the electronic dimension of Au TNPs and substantially affects their localized surface plasmon resonance (LSPR) properties that together allow us to achieve a sensitivity for microRNA assay as low as 140 zeptomolar concentrations for our nanoplasmonic sensors. We show that the position of a single base-pair mismatch in the -ssDNA/microRNA duplex dramatically alters the LSPR properties and detection sensitivity. The unprecedentedly high sensitivity of nanoplasmonic sensors has allowed us to assay four different microRNAs (microRNA-10b, 182, -143 and -145) from bladder cancer patient plasma (50 L/sample). For the first time, we demonstrate the utility of a label-free, nanoplasmonic sensor in quantification of tumor suppressor microRNAs - the level of tumor suppressor microRNAs goes down in cancer patient as compared to normal healthy individuals - in metastatic and non-metastatic bladder cancer patient plasma. Our statistical analysis of patient samples unequivocally suggests that the tumor suppressor microRNAs are more specific biomarkers (p-value of