Subscriber access provided by FLORIDA ATLANTIC UNIV
Article
Polymeric Antimicrobial N-halamine-Surface Modification of Stainless Steel Buket Demir, R. M. Broughton, Tung-Shi Huang, Michael Bozack, and S. D. Worley Ind. Eng. Chem. Res., Just Accepted Manuscript • DOI: 10.1021/acs.iecr.7b02412 • Publication Date (Web): 26 Sep 2017 Downloaded from http://pubs.acs.org on October 4, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Industrial & Engineering Chemistry Research is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
1
Polymeric Antimicrobial N-halamine-Surface Modification of Stainless
2
Steel
3
Buket Demir,1 R. M. Broughton,2 T.S. Huang,3 M. J. Bozack,4 and S.D. Worley*,1
4
1
5
36849
6
2
7
Engineering, Auburn University, Auburn, AL, 36849
8
3
Department of Poultry Science, Auburn University, Auburn, Alabama 36849
9
4
Department of Physics, Auburn University, Auburn, Alabama 36849
10
*
11
6980
Department of Chemistry and Biochemistry, Auburn University, Auburn, Alabama
Center for Polymers and Advanced Composites, Department of Mechanical
Author to whom correspondence should be addressed.
[email protected] 334-844-
12
1 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
13
ABSTRACT: The surfaces of materials fabricated from stainless steel are challenging
14
to functionalize with antimicrobial moieties. This work demonstrates that stainless steel
15
surfaces can be modified with an N-halamine-based copolymer in order to obtain
16
antimicrobial activity. In this regard a copolymer (HACM) of 2-acrylamido-2-methyl-1-
17
(5-methylhydantoinyl)propane and 3-cloro-2-hydroxypropyl methacrylate was
18
synthesized and grafted onto a stainless steel surface via covalent attachment.
19
Synthesized monomers and copolymers were characterized by NMR, FTIR, and XPS
20
spectral analyses. Upon treatment with dilute bleach, the stainless steel surfaces were
21
rendered antimicrobial, possessing a sufficient amount of chlorine content and excellent
22
stability and durability. The modified stainless steel samples inactivated 6 logs of
23
Staphylococcus aureus and Escherichia coli O157:H7 bacteria within 15 min of contact
24
time. Stabilities of the coatings toward washing and UVA exposure were also studied.
25
The stainless steel samples showed superior washing stabilities and re-generabilities.
26
After 5 cycles of washing, there was a very minimal change in the initial chlorine
27
contents, and the chlorine content could be recharged to its initial number of Cl+
28
atoms/cm2. However, only a moderate stability of the coatings was observed after UVA
29
irradiation. These results indicate that N-halamine precursor polymers can be facilely
30
applied to stainless steel surfaces by covalent bonding, and that robust, re-generable
31
antimicrobial stainless steel surfaces could be prepared via the N-halamine technology.
32
This technology exhibits potential for use in food processing, prevention of biofilm
33
formation, and in biomedical and health-care industries to support the prevention and
34
reduction of cross-contamination and health-care related infections.
35
KEYWORDS: N-halamines, antimicrobials, stainless steel, food processing, health
36
care
37 38 39 40
2 ACS Paragon Plus Environment
Page 2 of 27
Page 3 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
41 42
Industrial & Engineering Chemistry Research
INTRODUCTION Prevention of cross contamination of microorganisms and microbial biofilm
43
formation on surfaces employed in water purification and delivery systems, food
44
processing equipment, hospital equipment, biomedical implants, and medical devices has
45
been a major concern in the food and biomedical industries.1-3 Stainless steel has been
46
widely used in these industries due to its mechanical properties and resistance to
47
corrosion and chemicals.4,5 However, it is difficult to prevent adhesion and growth of
48
bacteria, formation of stable biofilms, and the increased resistance to sanitization
49
methods when stainless steel is used for surface applications in food processing plants
50
and for biomedical applications. Microbial contamination is a source of chronic
51
infections and the transmission of infectious diseases, and as such, it raises major public
52
health risks in these industries.6 In addition, due to the negative impact on public health,
53
it causes economic and product losses. Current methods for biofilm removal require
54
usage of chemical disinfectants and heat. However, the methods do not prevent or control
55
bacteria growth and biofilm formation, and they are ineffective, expensive, and raise
56
environmental concerns.3 The chemical functionalization of stainless steel surfaces has
57
proven to be a challenging endeavor. A review of this subject as relates to biofouling in
58
the food industry has been presented.7 Therefore, there is a need for development of
59
antimicrobial stainless steel surfaces to prevent cross contamination, to reduce
60
microorganism adhesion and survival, and to inactivate microorganisms on stainless steel
61
surfaces.
62
Researchers have been exploring various surface modification strategies such as
63
deposition of biocidal metals like silver, copper, and nickel,8-10 biopolymers,9,11-13 or
64
inorganic oxides such as TiO2 anatase14 by electrolysis, plasma, chemical vapor
65
deposition, layer-by-layer assembly by charged polyelectrolytes, electroless nickel, or
66
sol-gel procedures on stainless steel surfaces.8-14 Also, encouraging studies have been
67
reported concerning covalent attachment of biopolymers and synthetic polymers15 as well
68
as antibacterial peptides bound to a chitosan layer16 for the prevention of bio-adhesion.
69
However, further development of antimicrobial materials for surface modification that
70
possesses long lasting, stable, non-toxic, and effective antimicrobial properties is 3 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
71
necessary. In general the strategies mentioned above are expensive to implement, and
72
contact times necessary to effect even modest log reductions of bacteria on stainless steel
73
tend to be hours, which render practical application questionable.
74
A class of biocidal materials known as the N-halamines has been employed in
75
recent times for rendering a variety of surfaces antimicrobial.17-19 Among the many
76
biocidal agents which have been employed for surfaces, N-halamines are generally the
77
most effective due to superior antimicrobial efficacies against a broad spectrum of
78
microorganisms in brief contact times (minutes), non-toxicities, stabilities, and re-
79
generabilities.17-21 Although much of the work has been performed in the laboratories of
80
the authors on a variety of novel antimicrobial N-halamine derivatives used in many
81
different applications such as in water disinfection and in antimicrobial treatment of
82
textiles,20,22-29 the field has been expanding into many other laboratories and
83
applications.21,30-37
84
To our knowledge the only work reported to date concerning N-halamine
85
antimicrobial coatings on stainless steel has originated from the laboratory of Goddard
86
and coworkers.37 In their work well characterized multilayer coatings of branched
87
poly(ethylene imine) and poly(acrylic acid) were covalently attached to the surface of
88
stainless steel by layer by layer deposition using a non-antimicrobial coupling layer to
89
provide the grafting of the antimicrobial layer. Upon chlorination to produce an N-
90
chloramine coating, the surfaces produced about a 1.5 log inactivation of Listeria
91
monocytogenes at a contact time of 6 h.37
92
In the current work a copolymer (HACM) of 2-acrylamido-2-methyl-1-(5-
93
methylhydantoinyl) propane and 3-cloro-2-hydroxypropyl methacrylate was synthesized
94
and covalently attached to stainless steel (see Scheme 1). Following chlorination with
95
dilute bleach the surfaces demonstrated excellent antimicrobial efficacies (6 logs) against
96
Staphylococcus aureus and Escherichia coli O157:H7 in contact times of 15 to 30 min. It
97
has also been shown that upon washing, the surfaces maintain adequate stabilities of the
98
oxidative chlorine and can be recharged following exhaustion of the chlorine. The work
99
illustrates the potential for N-halamine modification of stainless steel to create an 4 ACS Paragon Plus Environment
Page 4 of 27
Page 5 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
100
antimicrobial surface for a variety of possible applications in the food and biomedical
101
industries.
102
EXPERIMENTAL SECTION
103
Materials and Instrumentation. 2-acrylamido-2-methyl-4-pentanone was
104
purchased from Tokyo Chemical Industry, Co., LTD (Tokyo, JP). 3-cloro-2-
105
hydroxypropyl methacrylate (CM), potassium cyanide, and ammonium carbonate were
106
obtained from Acros Organics (NJ, USA). 2,2’-Azobis(2-methylpropionitrile) (AIBN)
107
was obtained from Sigma-Aldrich, Inc. (St. Louis, MO, USA). All of the other chemicals
108
were purchased from Aldrich Chemical Company (Milwaukee, WI), TCI America
109
(Boston, MA), or Alfa Aesar (Heysham, UK), and used as received unless otherwise
110
noted. Stainless steel 316L (ASTM A240/A240M standard) with 2B finish (Ra roughness
111
of the surface typically being between 0.3 -0.4 µm) was purchased from McMaster-Carr
112
(Chicago, IL). Clorox® brand (Clorox, Inc., Oakland, CA) household bleach (8.25%
113
NaOCl) was used for the chlorination process. Bacterial cultures of Staphylococcus
114
aureus ATCC 6538 and Escherichia coli O157:H7 ATCC 43895 were purchased from
115
American Type Culture Collection (Rockville, MD), and Trypticase soy agar was
116
obtained from Difco Laboratories (Detroit, MI).
117
ATR-IR data were recorded with 32 scans at 4 cm-1 resolution with an ATR-FT-
118
IR spectrometer (Model Spectrum 400, Perkin Elmer Co., Waltham, MA, USA). 1H
119
NMR spectra were obtained with a Bruker 400 MHz spectrometer (16 scans).
120
Photoemission measurements were performed with a load-locked Kratos XSAM 800
121
surface analysis system equipped with a hemispherical energy analyzer. UVA stability
122
testing was conducted using a Q-Panel accelerated weathering tester which provides
123
UVA irradiation in the 315-400 nm regions.
124
Synthesis of the HACM Copolymer for Stainless Steel Surface Modification.
125
2-acrylamido-2-methyl-1-(5-methylhydantoinyl)propane (HA) was synthesized according
126
to a protocol described previously (Supporting information, Figure S1).23 Briefly, 2-
127
acrylamido-2-methyl-4-pentanone (0.1 mol), potassium cyanide (0.2 mol), and 5 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
128
ammonium carbonate (0.6 mol) were reacted at room temperature under nitrogen
129
atmosphere for 5 d in a water/ethanol (1:1, v/v) solvent mixture. After evaporation of the
130
ethanol and adjustment of the pH to 7 with 6 N hydrochloric acid, a crude white product
131
was obtained by filtration. The product was purified by recrystallization from acetonitrile.
132
The purified HA was obtained by filtration and dried at 45 °C overnight.
133
HACM copolymer was synthesized by free radical polymerization (Scheme 1). In
134
100 mL round-bottom flask an equimolar amount of 3-cloro-2-hydroxypropyl
135
methacrylate (CM) (10 mmol) and HA (10 mmol) was dissolved in methanol. After 1 wt
136
% azobis(isobutyronitrile) AIBN was added to the flask, nitrogen gas was bubbled
137
through the solution for 15 min to remove any dissolved oxygen before initiating the
138
reaction. Then the mixture was reacted at 65 °C for 2 h in the presence of AIBN as an
139
initiator. The polymerization reaction was performed under reflux conditions under
140
nitrogen atmosphere. After completion of the copolymer reaction, the solvent was
141
removed by evaporation, and the HACM copolymer was obtained as a white solid in 92
142
% yield. The structure of the copolymer was confirmed by FTIR and NMR analyses (see
143
Figures 1 and 2).
144 145
Scheme 1. Synthesis of HACM copolymer.
146
Antimicrobial Stainless Steel Surface Modification. Stainless steel (SS) sheets
147
were cut into 6.45 cm2 coupons. Before surface modification with the synthesized
148
copolymer, the stainless steel coupons were subjected to cleaning by soaking first in 6 ACS Paragon Plus Environment
Page 6 of 27
Page 7 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
149
acetone, then in ethanol, and finally in deionized (DI) water for 10 min in each solvent to
150
remove oil and dirt. Cleaned SS coupons were dried in an oven for 1 h at 45 °C prior to
151
an oxidation treatment. In order to further clean and create hydroxyl groups on the
152
stainless steel surface, the SS coupons were treated by immersion in a piranha solution
153
composed of 30 % hydrogen peroxide and sulfuric acid (H2O2: H2SO4 in 7:3 volumetric
154
ratio)37 for 30 min and agitated at 120 rpm at 25 °C, and then the coupons were rinsed in
155
copious amounts of DI water. The SS coupons were then dried at 130 °C for 10 min and
156
kept in sealed poly(propylene) bags. Prior to functionalization with HACM copolymer,
157
the SS coupons were first treated in 2 N NaOH for 30 min while agitating at 120 rpm at
158
25 °C. The coupons were then rinsed with DI water and dried at 45 °C for 1 h.
159
In order to provide antimicrobial properties, the stainless steel coupons were
160
subjected to N-halamine chemical modification. Synthesized HACM copolymer was
161
dissolved in 3 % (w/v) DMF. Then the SS coupons were immersed in the copolymer
162
solution and shaken for 15 min at 25 °C at 120 rpm. Following treatment with the
163
HACM copolymer, the coupons were dried under nitrogen atmosphere and then cured at
164
130 °C for 1 h to promote covalent bond formation between the oxidized stainless steel
165
surface and the HACM copolymer (Scheme 2).
166 7 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 27
167
Scheme 2. N-halamine HACM modification onto stainless steel and subsequent chlorine
168
activation.
169
Chlorination Process and Analytical Titration of the N-Halamine-modified
170
Stainless Steel Surface. The stainless steel coupons, which were treated and
171
functionalized with HACM, were subjected to a halogenation process to activate N-H
172
sites and form N-Cl bonds on the HACM copolymer to provide antimicrobial properties.
173
The SS coupons were chlorinated in a 10 % (v/v) aqueous solution of household bleach
174
(8.25 % sodium hypochlorite) at a pH of 7 (adjusted by a 6 N HCl solution) for 30 min.
175
After the chlorination process, the samples were first rinsed with tap and then DI water,
176
and finally dried at 45 °C for 1 h to remove any occluded free chlorine from the material.
177
The amount of oxidative chlorine content (Cl+) of the N-halamine-modified stainless
178
steel coupons was determined by standard iodometric/thiosulfate titration.38 The available
179
Cl+ atoms/cm2 was calculated using the following equation:
180
Total chlorine content (atoms/cm ) =
× 6.02 × 10
(1)
181
where N and V are the normality (equiv /L) and volume (L) of the titrant (Na2S2O3),
182
respectively, and A is the area of both of the sides of the steel surface used in the titration.
183
It was determined that for those stainless steel coupons containing only un-chlorinated
184
HACM as controls, the titration procedure yielded no detectable Cl+.
185
Stability and Regenerability Testing. The washing stabilities and the re-
186
generabilities of the chlorine content of the SS-HACM-Cl coupons were determined. In
187
this test 1 v/v% Liqui-Nox solution was prepared in DI water. 50 mL tubes were filled
188
with 35 mL of this detergent solution, and the chlorinated coupons were immersed for 45
189
min in an orbital shaker at 60 rpm at 25 °C for each cycle. The chlorine contents were
190
determined using iodometric titration (eq 1) after each washing cycle and after
191
regeneration.
192 193
The UVA light stabilities of the N-halamine-modified SS coupons were also evaluated. A set of HACM coated SS coupons was prepared for the UVA testing. For this 8 ACS Paragon Plus Environment
Page 9 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
194
testing, the SS coupons were modified with HACM and then chlorinated as described
195
above with the chlorine contents determined by iodometric titration after several time
196
intervals of UVA irradiation using eq 1.
197
Antimicrobial Efficacy Testing. Biocidal efficacies of the HACM-modified SS
198
surfaces and the chlorine activated antimicrobial SS surfaces were evaluated against
199
Gram-positive S. aureus (ATCC 6538) and Gram-negative E. coli O157:H7 (ATCC
200
43895) bacteria. In this procedure25 the bacteria were suspended in 100 µM phosphate
201
buffer (pH 7) to produce a suspension of known population (colony forming units, CFU).
202
Briefly, each strain of bacteria was streaked onto a trypticase soy agar (TSA) plate and
203
incubated at 37 °C for 16 h. Bacterial suspensions were prepared by suspending bacterial
204
colonies swabbed from the TSA plates in 100 µM Butterfield's phosphate buffer (BPB).
205
Bacterial populations of the bacterial suspensions were estimated by using a microplate
206
spectrophotometer (Thermo Fisher Scientific, Pittsburgh, PA) at O.D.640 nm , and inocula
207
with determined populations of about 4x107 CFU/mL were prepared. Then, an aliquot of
208
25 µL of this suspension (containing ca. 6 logs of CFU) was placed in the center of a 2.54
209
cm x 2.54 cm square coupon (HACM-treated or a native non-treated control), and a
210
second identical coupon was placed on top. Both coupons were covered by a sterile
211
weight to ensure good contact with the bacteria. After predetermined contact times (5, 10,
212
15, 30 and 60 min), the coupons were quenched by 5.0 mL of sterile 0.02 N sodium
213
thiosulfate solution to neutralize any remaining oxidative chlorine and thus terminate the
214
disinfection action. The quenched samples were first vortexed for 2 min, and then ten-
215
fold serial dilutions were prepared using pH 7, 100 µM phosphate buffer. Then the
216
dilutions were plated on trypticase soy agar plates. After the plates were incubated at 37
217
°C for 24 h, bacterial colonies were counted for the biocidal efficacy analysis. The
218
number of bacteria (CFU/sample) of inoculum and number of bacteria at each contact
219
time was calculated as shown below:
220
CFU/sample = (Number of bacteria colonies counted on agar plate x Dilution
221
factor x 5 mL) / Plated volume (0.025 mL)
222
(2)
The results were reported as log CFU/sample reduction calculated from the equation 9 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
223 224
below: Log Reduction = log10 (A) - log10 (B)
(3)
225
Where A is the population of the bacteria before treatment (control sample) (bacterial
226
population of the inoculum obtained by the agar plate count method), and B is the
227
population of the bacteria after treatment (bacterial population of the inoculum obtained
228
by the agar plate count method at each contact time).
229
Two coupons were used in each experiment for each collected datum for each
230
type of treatment against one type of bacteria at each determined contact time (5, 10, 15
231
and 30 min). As a result, in each experiment 24 coupons were tested against one type of
232
bacterium. All experiments were performed at least three times (on different days) using
233
fresh bacterial inocula for each type of bacterium.
234
RESULTS AND DISCUSSION
235
Synthesis and Characterization of the HACM Copolymer. 2-acrylamido-2-
236
methyl-1-(5-methylhydantoinyl)propane (HA) precursor (Scheme 1) was synthesized
237
according to a protocol described previously23 and analyzed by 1H NMR and FTIR
238
spectra (Supporting information, Figures S2 and S3). In this study precursor HA was
239
used because of its ability to potentially store higher chlorine content as a result of three
240
N-H sites within its structure. HACM copolymer was synthesized by free radical
241
polymerization in the presence of AIBN catalyst as illustrated in Scheme 1. FTIR and
242
NMR spectra were employed to characterize the synthesized HACM copolymer. The 1H
243
NMR spectrum of the synthesized HACM copolymer is shown in Figure 1. The mole
244
fraction of HA in the copolymer was calculated by comparing the signal area of total
245
methylene group protons (g, 3.62 ppm), adjacent to the chlorine atom (-CH2-Cl) of the
246
CM moiety, to the imide proton signal area (m, 10.60 ppm) of the HA moiety.
247
Consequently, the reactivity ratio of HA was slightly lower than that for CM, resulting in
248
slightly higher CM amount (n) in the copolymers as compared to the feed ratio; m/n was
249
0.95, whereas the feed ratio was 1.00.
10 ACS Paragon Plus Environment
Page 10 of 27
Page 11 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
250 251
Industrial & Engineering Chemistry Research
Figure 1. 1H NMR spectra of the synthesized HACM copolymer (solvent: DMSO-d6).
252
FTIR spectra of the 3-chloro-2-hydroxypropyl methacrylate (CM) and hydantoin
253
acrylamide (HA) precursors and synthesized HACM copolymer are shown in Figure 2. It
254
was observed that vinyl bands at 1636 cm-1 and 1621 cm-1 on the CM and HA spectra,
255
respectively, disappeared in the copolymer spectra indicating a complete
256
polymerization.23 Carbonyl stretching bands of the imide and heterocyclic and acyclic
257
amide groups of HACM could clearly be observed at 1767, 1708, and 1656 cm-1,
258
respectively. Vibrational stretching mode bands characteristic of the hydantoin carbonyl
259
moieties of HA and HACM were observed at 1767 and 1708 cm-1.39 In addition the C-N
260
vibrational stretching mode band for the acyclic amide group of HA and HACM was
261
observed at 1537 cm-1. The ester carbonyl stretching mode band for CM was identified at
262
1707 cm-1. The band due to C-Cl bond stretching on the CM monomer and the HACM
263
copolymer was observed at 751 cm-1.
11 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
100
%T
80 60
A 3444
%T
100
751
1636 1707
40 B
80 1767
60
3206
40 100
%T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 27
731
1664 1708
C
80 60
1621 1537
1767 3290
1537 1656
1708
40
3500 3000 2500 2000
1500
Wavelength cm
751
1000
-1
264 265
Figure 2. Representative ATR-FTIR spectra of precursor A: 3-cloro-2-hydroxypropyl
266
methacrylate (CM); precursor B: hydantoin acrylamide (HA) and C: synthesized
267
copolymer (HACM).
268
Characterization of HACM Copolymer-modified Stainless Steel (SS).
269
Attachment of the HACM copolymer onto the stainless steel surface was confirmed by
270
ATR-FTIR spectroscopy as shown in Figure 3. Unmodified native stainless steel (SS),
271
HACM modified but unchlorinated (SS-HACM), and HACM-modified and chlorinated
272
stainless steel (SS-HACM-Cl) spectra were observed. As expected the unmodified native
273
SS sample provided no vibrational bands. After chlorination of the HACM-treated
274
stainless steel surface, the N-H bonds were transformed into N-Cl bonds. As a result, the
275
vibrational stretching bands of the hydantoin carbonyl groups (amide and imide) in the
276
1720 to 1780 cm-1 region were shifted to higher wavenumber as observed previously for
277
chlorinated hydantoin moieties.23,28,29 In addition, as seen in the close up FTIR spectra of
278
the 3800-2500 cm-1 region the broad N-H band of the SS-HACM at 3235 cm-1 got
279
weaker and shifted to higher wavelength in the spectrum of SS-HACM-Cl. O-H
12 ACS Paragon Plus Environment
Page 13 of 27
280
vibrational band was detected centered at about 3355 cm-1 which can be attributed to the
281
presence of residual water.
95
90 85 100
%T
A
95 A
B
95 3235
90 85 100 90 80 70
1764
751
1655
1725 C 3355
% Transmission
%T
100
%T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
90
B C
3355
751
1783 1732
1662
85 4000
3235
2967
3500 3000 -1 Wavelength cm
2500
4000 3500 3000 2500 2000 1500 1000 -1 Wavelength cm
282 283
Figure 3. ATR-FTIR spectra of A: native stainless steel (SS); B: N-halamine HACM
284
modified, but un-chlorinated, stainless steel (SS-HACM); and C: N-halamine HACM
285
modified and chlorinated stainless steel (SS-HACM-Cl).
286
Further surface characterization was effected using XPS. The XPS analyzer was a
287
127 mm radius double-focusing concentric hemispherical energy analyzer (CHA)
288
equipped with an aberration compensated input lens (ACIL). XPS spectra were recorded
289
in the fixed analyzer transmission (FAT) mode with a pass energy of 80 eV, appropriate
290
for acquisition of medium resolution, high signal-to-noise spectra. The magnification of
291
the analyzer in the FAT mode was selected to collect electrons from the smallest
292
allowable (2 mm2) area on the specimen. The resolution of the instrument at the operating
293
parameters was measured from FWHM of the Ag3d5/2 peak to be 1.0 eV. The XPS
294
energy scale was calibrated by setting the Ag3d5/2 line on clean silver to exactly 368.3 eV
295
referenced to the Fermi level. Due to specimen charging during X-ray irradiation, the
296
energy axis of each XPS spectrum has been shifted to make the C1s binding energy line
297
equal to 285.0 eV, which is a standard hydrocarbon energy, (C-H and C-C bonds) used to
298
reference charge affected materials. The potential measured on a typical sample was 1-3
299
V. The photoelectrons were excited by a water-cooled, conventional (ie., non-
300
monochromatic) dual anode X-ray gun equipped with an Al window. The angle of the 13 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
301
incidence of the X-ray beam with the specimen normal was 51.5o. MgKα (1253.6 eV)
302
radiation was used exclusively. The XPS surface composition was calculated based on
303
the Scofield cross-sectional values accounting for the instrumental transmission function
304
in the FAT mode of operation.40
305
Survey XPS spectra in the 0 – 600 eV binding energy (BE) region for SS, SS-
306
HACM, and SS-HACM-Cl coupons are shown in Figure 4. The BE values to be
307
discussed below were measured from expanded spectra. The two primary bands
308
displayed for SS are at 531.9 and 285.0 eV for O1s and C1s, respectively. The O1s band
309
is the most intense representing 44.2 % of the spectrum as compared to 35.7 % for the
310
C1s band. This can be attributed to the surface oxidation treatment with piranha solution
311
followed by aqueous base creating O- groups on the SS surface. Upon treatment with
312
copolymer HACM to form SS-HACM, the relative contribution of the O1s band
313
decreases to 13.9 % as compared to the C1s band at 69.5 %. The O1s band also shifts to
314
higher BE at 532.1 eV. This observation is consistent with O- groups on the SS surface
315
reacting with C-Cl functionalities on HACM to form covalent bonds in a nucleophillic
316
substitution with Cl- ions as leaving groups. The O- groups, now losing their formal
317
negative charge, would be expected to provide bands at higher O1s BE as observed. The
318
resolution of the XPS was not sufficient to distinguish between the several types of
319
covalently bound oxygen on the copolymer and surface. Also appearing in the XPS
320
spectrum for SS-HACM were prominent bands for nitrogen (N1s at 399.8 eV, 5.3 %) and
321
chlorine (Cl2p at 200.6 eV, 9.1 %), which were not present in the XPS spectrum for SS.
322
The presence of nitrogen is firm evidence that HACM is indeed attached to the surface of
323
SS to form SS-HACM. The presence of chlorine indicates that not all of the C-Cl
324
functionalities in HACM were reacted with O- groups on SS. This form of chlorine is not
325
oxidative (Cl+) and, as such, its presence can not be determined by our titration
326
procedure. Upon oxidative chlorination with dilute bleach to form N-Cl polar covalent
327
bonds in producing SS-HACM-Cl, little change in the XPS spectrum other than an
328
increase in the contribution of the Cl2p band would be expected. This was the case as
329
bands for oxygen (O1s at 532.1 eV, 13.8 %), carbon (C1s at 285.0 eV, 64.0 %), nitrogen
330
(N1s at 399.8 eV, 6.1%), and chlorine (Cl2p at 200.6 eV, 16.1 %) were obtained. The
14 ACS Paragon Plus Environment
Page 14 of 27
Page 15 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
331
resolution of the XPS spectra was not sufficient to distinguish slight changes in oxidation
332
states of the elements present, eg. N-H, N-Cl, and C-Cl. The only accurate means to
333
quantitate the amount of oxidative chlorine, the source of antimicrobial activity, is with
334
an iodometric/thiosulfate titration as has been done in this work. In summary, XPS
335
provides evidence consistent with our hypothesis that the copolymers HACM and
336
HACM-Cl are covalently bound to the surface of SS.
337
338 339
Figure 4. XPS of native stainless steel (SS); N-halamine HACM modified, but un-
340
chlorinated, stainless steel (SS-HACM); and N-halamine HACM modified and
341
chlorinated stainless steel (SS-HACM-Cl).
342
The effect of chlorination condition on active chlorine loadings of the HACM
343
modified SS coupons was determined (Table 1). The active chlorine content of the
344
HACM-SS coupons chlorinated for 30 min at different household bleach concentrations
345
(1, 5, and 10 v/v %) was observed. As seen in Table 1, the active chlorine content was 15 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
346
increased from 5.05 x1016 atoms/cm2 to 1.47 x1017 atoms/cm2 with an increase of the
347
sodium hypochlorite concentration. In the previous study of SS modified with branched
348
poly(ethyleneimine) and poly(acrylic acid), a layer-by-layer deposition enabled the
349
authors to obtain a chlorine loading of about 2.2 x 1016 atoms/cm2. We have noted
350
previously that a chlorine loading of at least 1 x 1016 atoms/cm2 is necessary to obtain
351
antimicrobial efficacy for any surface modified by a chloramine.41
352
Table 1. Chlorine loadings of the HACM modified SS coupons at different
353
concentrations of sodium hypochlorite. Each datum represents an average of three
354
SS coupons (2.54 cm x 2.54 cm in size). SS-HACM-Cl
355
Bleach concentration
Cl+
(wt %)
(atoms/cm2)
1
5.05 x 1016 ± 6.77 x 1015
5
7.73 x 1016 ± 1.13 x 1016
10
1.47 x 1017 ± 4.04 x 1016
In addition, the chlorination reaction times of the modified SS coupons were
356
evaluated. The coupons were chlorinated in 10 v/v % household bleach solution at
357
different time intervals for 15, 30, 45 and 60 min, respectively (Figure 5). The
358
chlorination time did not significantly influence the active chlorine content; only a slight
359
increase of the chlorine loading was observed at extended times. A chlorination time of
360
30 min was chosen the remainder of the study.
16 ACS Paragon Plus Environment
Page 16 of 27
Page 17 of 27
2.000E+17
Cl+ atoms/cm2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
1.800E+17 1.600E+17 1.400E+17 1.200E+17 1.000E+17 0
20
40
60
80
Time (min) 361 362
Figure 5. Chlorine loadings of the HACM modified SS coupons at different chlorination
363
time intervals. Each datum point represents an average of three SS coupons (2.54 cm x
364
2.54 cm in size).
365
Stability Testing. Washing and re-chargeability of the chlorine activated HACM
366
modified stainless steel samples were evaluated, and the results are illustrated in Table 2.
367
It was found that after 5 washing cycles SS-HACM-Cl samples possessed most of their
368
initial chlorine loadings. Re-chargeability of the chlorine content of the HACM-Cl-
369
modified samples was also measured. The samples were capable of being reactivated to
370
their initial contents after the re-chlorination procedure. These data showed that HACM
371
attachment onto stainless steel is stable, and after exhaustion of the chlorine, the N-Cl
372
bond can be regenerated repeatedly over numerous cycles without the necessity of
373
reapplication of the HACM coating.
374
The stabilities of the un-chlorinated and chlorinated HACM modified stainless
375
steel samples towards UVA light irradiation are presented in Table 3. The oxidative
376
chlorine content (Cl+ %) decreased significantly with the extension of UVA light
377
exposure time. After 1 h of UVA light exposure, SS-HACM-Cl samples lost about 44%
378
of the bound chlorine dropping from 9.19 x 1016 atoms/cm2 to 5.11 x 1016 atoms/cm2.
379
However, after 1 h the number of available chlorine atoms did not significantly change
380
upon continuous UVA exposure. Chlorine content of the samples remained at around 5 to
381
4 x 1016 atoms/cm2 until a 12 h exposure time. After 12 h of UVA light irradiation, 63%
382
of the bound chlorine was lost. A portion of the oxidative chlorine could not be recovered 17 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
383
after exposing to dilute sodium hypochlorite. This could be due to the intramolecular
384
rearrangement of the chlorine atoms onto carbon atoms of the copolymer followed by
385
decomposition and detachment from the SS surface. This phenomenon has been observed
386
by Worley and coworkers in previous studies of hydantoinyl siloxane polymers attached
387
to cellulose.42 It has been reported that decomposition and the loss of the chlorine moiety
388
of Si-alkyl functional N-halamine-coated cotton substrates due to a scission reaction can
389
be improved by addition of TiO2 moieties into the structure.43 Further studies need to be
390
conducted in order to confirm the mechanism of this decomposition process for HACM
391
on stainless steel.
392
Table 2. Washing stability of HACM copolymer modified stainless steel (SS-HACM-
393
Cl). Washing cycle
X
Y
Cl+ atoms/cm2
Cl+ atoms/cm2
Initial
5.14 x 1016
5.14 x 1016
1
6.42 x 1016
6.13 x 1016
2
4.52 x 1016
7.00 x 1016
3
4.38 x 1016
5.54 x 1016
5
4.52 x 1016
6.85 x 1016
394
X: HACM modified SS coupons were chlorinated before washing and titrated after
395
washing; Y: HACM modified SS coupons were chlorinated before washing and re-
396
chlorinated after washing and titrated. Each datum represents an average of three SS
397
coupons (2.54 cm x 2.54 cm in size).
398 399
Table 3. UVA light stability of activated chlorine on the HACM modified stainless
400
steel coupons. Exposure Time
X
Y
(h)
Cl+ atoms/cm2
Cl+ atoms/cm2
0
9.19 x 1016
1
5.11 x 1016
2
4.96 x 1016
5.83 x 1016
18 ACS Paragon Plus Environment
Page 18 of 27
Page 19 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
3
5.98 x 1016
6
4.38 x 1016
4.96 x 1016
12
3.35 x 1016
4.38 x 1016
401
X: HACM-modified SS coupons were chlorinated before UVA exposure, the chlorine
402
remaining determined for the coupons after UVA exposure; Y: HACM-modified and
403
chlorinated SS coupons were re-chlorinated after UVA exposure. Each datum represents
404
an average of three SS coupons (2.54 cm x 2.54 cm size).
405
Antimicrobial Efficacy. The antimicrobial efficacy results for the native non-
406
modified SS, modified un-chlorinated HACM, and modified and chlorinated HACM-Cl
407
stainless steel samples have been summarized in Table 4. Average available chlorine
408
contents of the halogen-activated SS-HACM-Cl coupons, used for antimicrobial efficacy
409
analysis, were measured as 9.6 x 1016 ± 1.9 x 1016 atoms/cm2. All samples (control, SS-
410
HACM and SS-HACM-Cl) were challenged with S. aureus and E. coli O157:H7 at
411
approximately 6 logs (CFU/sample) of initial inoculum concentration for both S. aureus
412
and E. coli O157:H7.
413
As expected, control native stainless steel coupons and HACM modified stainless
414
steel (SS-HACM) coupons showed a limited degree of bacterial reduction. These results
415
are in agreement with those for N-halamine-modified textile surfaces for which some
416
viable CFU’s could not be recovered using the experimental procedure. The control
417
native stainless steel coupons and HACM modified stainless steel (SS-HACM) coupons
418
did not inactivate any bacteria; the variability in the data in Table 4 for these control
419
coupons and for the coupons of SS-HACM-Cl for which complete inactivation was not
420
obtained can be attributed to the challenging microbiology analysis procedure. The SS-
421
HACM-Cl stainless steel coupons provided a complete inactivation of about 6 logs (the
422
limit of detection for the antimicrobial assay) against S. aureus and E. coli O157:H7
423
bacteria within 15 min of contact time in all three replicate assays. To the best of our
424
knowledge, these results show superior inactivation time and efficacy against both Gram-
425
positive and Gram-negative bacteria when compared to previous antimicrobial modified
426
stainless steel surfaces. Probably these observations are a result of higher chlorine
427
loadings for the HACM-Cl on SS than was achieved in the study of SS modified by a 19 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
428
chlorinated copolymer of poly(ethyleneimine) and poly(acrylic acid).37
429
Table 4. Antimicrobial efficacy of control-SS (native non-modified), SS-HACM
430
(HACM modified and un-chlorinated), SS-HACM-Cl (HACM modified and
431
chlorinated) stainless steel coupons against E.coli 0157:H7 and S. aureus. Samples
Contact time (min)
Inoculum
Control-SS HACM-SS HACM-SS-Cl
60 60 5 10 15 30 60
Bacterial log reduction E.coli O157:H7 Exp1 Exp 2
Exp3
6.20
5.99
6.30
0.45 2.34 3.12 ND* 6.20 6.20 6.20
0.46 2.28 4.16 ND* 5.99 5.99 5.99
1.03 1.05 0.75 1.79 6.30 6.30 6.30
432 Samples
Contact time (min)
Inoculum
Bacterial log reduction S. aureus Exp1
Exp2
Exp3
6.24
5.85
5.83
Control-SS HACM-SS HACM-SS-Cl
433 434 435 436 437 438 439 440 441
60 1.46 1.34 1.27 60 2.21 2.16 1.32 5 3.71 3.72 0.96 * * 10 ND ND 5.83 15 6.24 5.85 5.83 30 6.24 5.85 5.83 60 6.24 5.85 5.83 1 Exp 1: The inoculum concentrations were 6.20, and 6.24 logs for E. coli O157:H7 and S. aureus, respectively. 2 Exp 2: The inoculum concentrations were 5.99, and 5.85 logs for E. coli O157:H7 and S. aureus, respectively. 3 Exp 3: The inoculum concentrations were 6.30, and 5.83 logs for E. coli O157:H7 and S. aureus, respectively. * ND: No determination.
FUTURE STUDIES 20 ACS Paragon Plus Environment
Page 20 of 27
Page 21 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
442
Industrial & Engineering Chemistry Research
Before the antimicrobial stainless steel modified with the newly synthesized N-
443
halamine coating discussed in this work can enter practical application, long-term
444
stability testing under hydrothermal conditions as well as toxicity/cytotoxicity and
445
biocompatibility data will need to be evaluated.44 It is encouraging that there are reports
446
of N-halamine polymer coatings on other surfaces which have indicated that toxicity
447
problems are not likely to be an issue for the N-halamine-treated stainless steel. 45-47
448
CONCLUSIONS
449
A new hydantoin copolymer, containing N-halamine forming moieties, was
450
synthesized and chlorinated in order provide antimicrobial stainless steel coatings. The
451
work demonstrated a successful stainless steel surface modification through covalent
452
attachment of HACM copolymer via grafting onto the surfaces. The stainless steel
453
surfaces provided excellent antimicrobial properties against S. aureus and E. coli
454
O157:H7 bacteria upon activation of the N-halamine sites by a chlorination process.
455
Compared to previous reported research, this newly developed antimicrobial N-halamine
456
copolymer-modified stainless steel exhibited superior antimicrobial properties and
457
deactivated 6 logs of Gram-negative and Gram-positive bacteria populations within only
458
15 min of contact time. Washing results showed excellent stability and durability of the
459
HACM-Cl stainless steel coating. In addition, after 5 cycles of washing, the test samples
460
could be recharged to their initial chlorine contents suggesting that a strong and stable
461
copolymer attachment onto the surface could be achieved. However, UVA irradiation
462
caused moderate decomposition of the coatings; after 12 h of UVA exposure time, a
463
sufficient amount of chlorine remained for bacterial inactivation, and the samples could
464
be partially re-chlorinated. Further work is ongoing to explore means of stabilizing the
465
coatings against photolytic decomposition. The antimicrobial stainless steel surfaces
466
developed in this study possesses reasonable potential for use in industries (such as food
467
and biomedical) in which cross contamination and biofilm formation is a continuous
468
problem.
469
ASSOCIATED CONTENT
470
Supporting Information 21 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
471
Proof of successful synthesis of monomer HA. This material is available free of charge
472
online at http://pubs.acs.org.
473
AUTHOR INFORMATION
474
Corresponding Author
475
*
476
Notes
477
The authors claim no competing financial interest.
478
REFERENCES
479
(1)
480
Nutr. Res. 2001, 43, 319-370.
481
(2)
482
Biodegrad. 2002, 49, 259-270.
483
(3)
484
Microorganisms on Contact. J. Mater. Chem. 2009, 19, 7796-7806.
485
(4)
486
Austenitic Stainless Steels. Wear 2000, 239, 48-58.
487
(5)
488
Cardiol. 2001, 14, 95-115.
489
(6)
490
between Biofilms and Metals. Curr. Opin. Biotechnol. 2004, 15, 181-186.
491
(7)
492
Cleanability: A Review with Special Reference to the Food Industry. Biofouling 1996,
493
10(4), 275-300.
494
(8)
495
Boughton, R. I. Chemical Assembly of Silver Nanoparticles on Stainless Steel for
496
Antimicrobial Applications. Surf. Coat. Technol. 2010, 204, 3871-3875.
S. D. Worley. E-mail:
[email protected].
Frank, J. F. Microbial Attachment to Food and Food Contact Surfaces. Adv. Food
Videla, H. A. Prevention and Control of Biocorrosion. Int. Biodeterior.
Ferreira, L.; Zumbuehl, A. Non-Leaching Surfaces Capable of Killing
Thomann, U. I.; Uggowitzer, P. J. Wear–Corrosion Behavior of Biocompatible
Cheatham, J. P. Improved Stents for Pediatric Applications. Prog. Pediatr.
Beech, I. B.; Sunner, J. Biocorrosion: Towards Understanding Interactions
Boulane-Petermann, L. Processes of Bioadhesion on Stainless Steel Surfaces and
Chen, L.; Zheng, L.; Lv, Y.; Liu, H.; Wang, G.; Ren, N.; Liu, D.; Wang, J.;
22 ACS Paragon Plus Environment
Page 22 of 27
Page 23 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
497
(9)
498
Weerdt, C.; Martial, J.; Duwez, A. S.; Detrembleur, C. Antibacterial Polyelectrolyte
499
Micelles for Coating Stainless Steel. Langmuir 2012, 28, 7233-7241.
500
(10)
501
Antimicrobial Coatings Prepared by Electroless Co-Deposition of Fluoropolymer and
502
Cationic Silica Nanoparticles on Stainless Steel: Efficacy against Listeria
503
Monocytogenes. ACS Appl. Mater. Interfaces 2016, 8, 15926-15936.
504
(11)
505
Inhibiting Sulfate-Reducing Bacteria in Biofilms on Steel with Antimicrobial Peptides
506
Generated in Situ. Appl. Microbiol. Biotechnol. 1999, 52, 267-275.
507
(12)
508
Minerals Substituted Porous Hydroxyapaptite/Poly(3,4-Ethylenedioxy Pyrrole-Co-3,4-
509
Ethylenedioxythiophene) Bilayer Coatings on Surgical Grade Stainless Steel and Its
510
Antibacterial and Biological Activities for Orthopedic Applications. ACS Appl. Mater.
511
Interfaces 2016, 8, 12404-12421.
512
(13)
513
Thromboresistant Surface on Biomedical Stainless Steel Via Layer-by-Layer Deposition
514
Anticoagulant. Biomaterials 2003, 24, 4699-4705.
515
(14)
516
Stainless Steel. Surf. Coat. Technol. 2007, 201, 9319-9324.
517
(15)
518
Grafting of Lysozyme and/or Poly(ethylene glycol) to Prevent Biofilm Growth on
519
Stainless Steel Surfaces. J. Phys. Chem. B. 2009, 113, 2101-2109.
520
(16)
521
Antimicrobial Peptides on Stainless Steel Surface and Biofilm Resistance Tests. Coll.
522
Surf. B: Biointerf. 2011, 84, 301-309.
523
(17)
Worley, S. D.; Sun, G. Biocidal Polymers. Trends Polym. Sci. 1996, 4, 364-370.
524
(18)
Kenawy, E.-R.; Worley, S. D.; Broughton, R. M. The Chemistry and Applications
525
of Antimicrobial Polymers: A State-of-the-Art Review. Biomacromolecules 2007, 8,
526
1359-1384.
Falentin-Daudre, C.; Faure, E.; Svaldo-Lanero, T.; Farina, F.; Jerome, C.; Van De
Huang, K.; Chen, J.; Nugen, S. R.; Goddard, J. M. Hybrid Antifouling and
Jayaraman, A.; Hallock, P.; Carson, R.; Lee, C.-C.; Mansfeld, F.; Wood, T.
Subramani, R.; Elangomannan, S.; Louis, K.; Kannan, S.; Gopi, D. Fabrication of
Tan, Q.; Ji, J.; Barbosa, M. A.; Fonseca, C.; Shen, J. Constructing
Evans, P.; Sheel, D. W. Photoactive and Antibacterial TiO2 Thin Films on Caro, A.; Humblot, V.; Methivier, C.; Minier, M.; Salmain, M.; Pradier, C-M.
Hequet, A.; Humblot, V.; Berjeaud, J-M.; Pradier, C-M. Optimized Grafting of
23 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
527
(19)
528
Coatings: A Review of Their Synthesis, Characterization, and Applications.
529
Biomacromolecules 2013, 14, 585-601.
530
(20)
531
Polymer. Ind. Eng. Chem. Res. 1994, 33, 168-170.
532
(21)
533
Coating by N-halamine Polyelectrolytes on A Cellulose Substrate. J. Mater. Chem. B.
534
2015, 3, 1446-1454.
535
(22)
536
Broughton, R. M.; Huang, T. S. N-Halamine Biocidal Coatings. J. Ind. Microbiol.
537
Biotechnol. 2007, 34, 157-163.
538
(23)
539
Halamine Acrylamide Monomer and Its Copolymers for Antimicrobial Coatings. React.
540
Funct. Polym. 2011, 71, 561-568.
541
(24)
542
Halamine Biocidal Coatings Via a Layer-by-Layer Assembly Technique. Langmuir 2011,
543
27, 4091-4097.
544
(25)
545
Halamine-Modified Antimicrobial Polypropylene Nonwoven Fabrics for Use against
546
Airborne Bacteria. ACS Appl. Mater. Interfaces 2015, 7, 1752-1757.
547
(26)
548
J.; Sun, G. Biocidal Poly (Styrenehydantoin) Beads for Disinfection of Water. Ind. Eng.
549
Chem. Res. 2003, 42, 280-284.
550
(27)
551
Antimicrobial Silica and Sand Particles Functionalized with an N Halamine
552
Acrylamidesiloxane Copolymer. J. Appl. Polym. Sci. 2016, 133, 43413.
553
(28)
554
Halamine Copolymers for Biocidal Coatings. React. Funct. Polym. 2012, 72, 673-679.
555
(29)
556
Polymeric Antimicrobial N-Halamine Epoxides. ACS Appl. Mater. Interfaces 2011, 3,
557
2845-2850.
Hui, F.; Debiemme-Chouvy, C. Antimicrobial N-Halamine Polymers and
Sun, G.; Wheatley, W. B.; Worley, S. D. A New Cyclic N-Halamine Biocidal
Liu, Y.; Li, J.; Cheng X.; Ren, X.; Huang, T. S. Self-assembled Antibacterial
Liang, J.; Wu, R.; Wang, J. W.; Barnes, K.; Worley, S. D.; Cho, U.; Lee, J.;
Kocer, H. B.; Worley, S. D.; Broughton, R. M.; Huang, T. S. A Novel N-
Cerkez, I.; Kocer, H. B.; Worley, S. D.; Broughton, R. M.; Huang, T. S. N-
Demir, B.; Cerkez, I.; Worley, S. D.; Broughton, R. M.; Huang, T. S. N-
Chen, Y.; Worley, S. D.; Kim, J.; Wei, C.-I.; Chen, T.-Y.; Santiago, J.; Williams,
Jiang, Z.; Demir, B.; Broughton, R. M.; Ren, X.; Huang, T. S.; Worley, S. D.
Cerkez, I.; Kocer, H. B.; Worley, S. D.; Broughton, R. M.; Huang, T. S. N-
Kocer, H. B.; Cerkez, I.; Worley, S. D.; Broughton, R. M.; Huang, T. S.
24 ACS Paragon Plus Environment
Page 24 of 27
Page 25 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
558
(30)
559
Hydantoin-Containing Monomers onto High Performance Fibers by a Continuous
560
Process. J. Appl. Polym. Sci. 2003, 88, 1032-1039.
561
(31)
562
for Use in Dental Unit Water Lines. ACS Appl. Mater. Interfaces 2011, 3, 2895-2903.
563
(32)
564
of Antibacterial Coatings with N-Halamine/TiO2. Cellulose 2013, 20, 2151-2161.
565
(33)
566
of N-Halamine-Based Antimicrobial Fillers. Ind. Eng. Chem. Res. 2012, 51, 5148-5156.
567
(34)
568
and N-Halamine Character: Characterization and Biocidal Efficacy. J. Agric. Food Chem.
569
2015, 63, 4243-4251.
570
(35)
571
Polymeric Surface Modifiers. Biomaterials 2006, 27, 1316-1326.
572
(36)
573
Liu, F.; Harnoode, C. N-Halamine-Decorated Polystyrene Nanoparticles Based on 5-
574
Allylbarbituric Acid: From Controllable Fabrication to Bactericidal Evaluation. J.
575
Colloid Interface Sci. 2014, 413, 92-99.
576
(37)
577
Via Surface Modification with N Halamines: Characterization of Surface Chemistry and
578
N Halamine Chlorination. J. Appl. Polym. Sci. 2013, 127, 821-831.
579
(38)
580
Water and Wastewater 16th Ed., 1985, 298-300.
581
(39)
582
for Poly(Lactic Acid) Nonwoven Fabrics. Polymer 2013, 54, 536-541.
583
(40)
Scofield, J. H., Lawrence Livermore Laboratory Report No. UCRL-51326, 1973.
584
(41)
Worley, S. D.; Chen, Y.; Wang, J-W.; Wu, R.; Cho, U.; Broughton, R. M.; Kim,
585
J.; Wei, C-I.; Williams, J. F.; Chen, J.; Li, Y. Novel N-halamine Siloxane Monomers and
586
Polymers for Preparing Biocidal Coatings. Surf. Coat. Intern. Part B: Coat. Trans. 2005,
587
88, 93-99.
Sun, Y.; Sun, G. Novel Refreshable N-Halamine Polymeric Biocides: Grafting
Luo, J.; Porteous, N.; Sun, Y. Rechargeable Biofilm-Controlling Tubing Materials
Li, J.; Li, R.; Du, J.; Ren, X.; Worley, S. D.; Huang, T. S. Improved UV Stability
Padmanabhuni, R. V.; Luo, J.; Cao, Z.; Sun, Y. Preparation and Characterization
Bastarrachea, L. J.; Goddard, J. M. Antimicrobial Coatings with Dual Cationic
Makal, U.; Wood, L.; Ohman, D. E.; Wynne, K. J. Polyurethane Biocidal
Dong, A.; Huang, Z.; Lan, S.; Wang, Q.; Bao, S.; Siriguleng; Zhang, Y.; Gao, G.;
Bastarrachea, L. J.; Goddard, J. M. Development of Antimicrobial Stainless Steel
American Public Health Association. Standard Methods for the Examination of
Cerkez, I.; Worley, S. D.; Broughton, R. M.; Huang, T. S. Antimicrobial Coatings
25 ACS Paragon Plus Environment
Industrial & Engineering Chemistry Research
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
588
(42)
589
Mechanism of Photolytic Decomposition of N-Halamine Antimicrobial Siloxane
590
Coatings. ACS Appl. Mater. Interfaces 2010, 2, 2456-2464.
591
(43)
592
Characterization and Mechanism for the Protection of Photolytic Decomposition of N-
593
Halamine Siloxane Coatings by Titanium Dioxide. ACS Appl. Mater. Interfaces 2016, 8,
594
3516-3523.
595
(44)
We thank a reviewer for this observation.
596
(45)
Ma, K.; Liu. Y.; Xie, Z.; Li, R.; Jiang, Z.; Ren, X.; Huang, T-S. Synthesis of
597
Novel N-Halamine Epoxide Based on Cyanuric Acid and Its Application for
598
Antimicrobial Finishing. Ind. Eng. Chem. Res. 2013, 52, 7413-7418.
599
(46)
600
Membranes Based on Poly(3-hydroxybutyrate-co-4-hydroxybutyrate) and Quaternarized
601
N-halamine Polymer. RSC Adv. 2016, 6, 42600-42610.
602
(47)
603
polyacrylamide Multilayer Core-shell Nanoparticles for Antibacterial Ability. J. Mater.
604
Chem. B 2015, 3, 7203-7212.
Kocer, H. B.; Akdag, A.; Worley, S. D.; Acevedo, O.; Broughton, R. M.; Wu, Y.
Liu, Y.; Li, J.; Li, L.; McFarland, S.; Ren, X.; Acevedo, O.; Huang, T-S.
Fan, X.; Ren, X.; Huang, T-S.; Sun, Y. Cytocompatible Antibacterial Fibrous
Qiu, Q.; Liu, T.; Li, Z.; Ding, X. Facile Synthesis of N-halamine-labeled Silica-
605
26 ACS Paragon Plus Environment
Page 26 of 27
Page 27 of 27
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Industrial & Engineering Chemistry Research
83x40mm (150 x 150 DPI)
ACS Paragon Plus Environment