Article
Precise analysis of Gallium isotopic composition by MC-ICP-MS Wei Yuan, Jiubin Chen, Jean-Louis Birck, Zuoying Yin, ShengLiu Yuan, HongMing Cai, Zhongwei Wang, Qiang Huang, and ZhuHong Wang Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.6b02317 • Publication Date (Web): 04 Sep 2016 Downloaded from http://pubs.acs.org on September 9, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
Table 1. Elution sequence of the two-step separation Eluant
Volume(ml)
Eluted
First column charged with 1.8 ml AG1-X4 resin H2O
10
Cleaning
0.1 M HCl 6 M HCl Sample (6 M HCl) 6 M HCl
10 10 1 10
Cleaning Cleaning + Conditioning Loading Matrix
0.5 M HCl
5
Ga (Fe and Mo)
Second column charged with 1.4 ml Ln-spec resin 0.5 M HCl 0.5 M HCl sample solution 1 M HCl
10 5 6
Conditioning loading + Ga Ga
0.25 M Oxalic acid + 3 M HCl 0.1 M HCl 4 M HCl
20 20 20
Cleaning (Mo, Fe) Cleaning Cleaning (Fe)
2 3
1
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 2 of 40
4 5
Table 2. Nu Plasma II ICP-MS Operating Conditions Component
parameter
Stage control Vocuum Capacitor Gas Panel
Back / Forward: 8.83; In / Out: 3.97; Up/Down: 2.93 Lighting: 2330; Running: 2160 Coolant (L/min): 13.0; Aux (L/min): 0.80; Neb (Psi): 27.6; Mix Gas (L/min): 0.00; Mix Gas 2 (L/min): 0.00 Forward (W): 1300 Quad1: 6.3; Quad2: 74.5 HV1: 5999; HV2: 4412; HV3: 3671; HV4: 1700; HV5: 2814; HV6:2408 146Ge2+ (H7); 71Ga (H4); 140Ce2+ (H2); 69Ga (Ax); 137Ba2+ (L1); 68Zn (L2); 135Ba2+ (L3); 67Zn (L4); 66Zn (L5)
RF Power Quads High Voltage Faraday cups setting
6 7
2
ACS Paragon Plus Environment
Page 3 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
8
Table 3. Neptune Plus ICP-MS Operating Settings Component
Parameter
Zoom Optics Parameter Center Cup Source lenses
Focus Quad [V] :10.00; Dispersion Quad [V] :0.00 Decelerator [V]:8199.9; Suppressor [V]:9965.0 Extraction [V] :-2000; Focus [V] :-611.0; X-Defl [V] :6.49; Y-Defl [V]:-4.30; Shape [V]:206.00 Rot Quad [V]:18.93; Source Offset [V]:-6.00 Cool gas [L/min]:16.00; Aux Gas [L/min] :0.88; Sample Gas [L/min]:1.065; Add. Gas1 [L/min]:0.00; Add. Gas 2 [L/min]: 0.00; X-Pos [mm]:0.010; Y-Pos [mm] :-3.300; Z-Pos [mm] :-1.850; Peri.Pump [rpm] :5.00; RF Power [W]:1200 71Ga (H4); 70Zn (H3); 69Ga (H2); 137Ba2+ ( H1); 67Zn (RPQ/IC1); 66Zn (L1); 65Cu (L2); 63Cu (L4)
Inlet System
Faraday cups setting 9
3
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 4 of 40
10 11
Table 4. Potential species interfering Ga isotope measurement on MC-ICP-MS Species
Mass-69
Mass-71
Monoisotopic species Argides (Hydro)-Oxides
69
71
Elemental species Double-charged species
Ga 40 Ar29Si+, 37Cl16O2+ 51 18 + 52 V O , Cr17O+, 68Zn1H+, 50 Ti 18O1H+, 50V 18O1H+, 50 Cr 18O1H+, 51V17O1H+, 52 Cr16O1H+, 33 36 S S 138Ba2+, 138La2+, 138Ce2+
Ga Ar15N16O 53 Cr18O+, 54Cr17O+, 55Mn16O+, 54 17 + 70 Fe O , Zn1H+, 52Cr18O1H+, 53 Cr17O1H+, 54Cr16O1H+, 54 16 1 + Fe O H 40
142Nd2+, 142Ce2+
12 13
4
ACS Paragon Plus Environment
Page 5 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47
Analytical Chemistry
14
Table 5. Results of comparison between Nu and Neptune mass spectrometers δ71Ga-SSB (‰)
Sample JB-2 (basalt) BHVO-2 (basalt) Gallium (III) nitrate hydrate GBW(E) 08056 G-2 (Granite) JG-2 (Granite) MAG-1 (Marine mud) GXR-2 (Soil) GXR-3 (Deposit) GBW 07405 (Soil) 15 16 17
δ71Ga-MEEN (‰)
Nu (mean ±2SD)
Neptune (mean ±2SD)
Neptune (mean ±2SD)
0.11 ±0.03 (n=9) 0.08 ±0.02 (n=9 ) 1.83 ±0.04 (n=10) 1.74 ±0.05 (n=21) 0.03 ±0.03 (n=5) 0.02 ±0.03 (n=3) 0.06 ±0.04 (n=5) 0.04 ±0.05 (n=4) 0.03 ±0.05 (n=4) 0.02 ±0.04 (n=5)
0.10 ±0.04 (n=10) 0.07 ±0.03 (n=10) 1.81 ±0.06 (n=6) 1.73 ±0.03 (n=5)
0.11 ±0.02 (n=9) 0.08 ±0.02 (n=10) 1.82 ±0.03 (n=9) 1.72 ±0.02 (n=9)
n, the number of repeated measurements for the same sample including different column procedures (2 or 3). 2SD, 2 times the standard deviation of the population of n repeated measurements.
5
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 6 of 40
18
Figure 1. Elution curve of Ga seperation from matrix on the AG 1×4 resin (A) and the Ln-spec
19
resin (B). Though most of the major and trace elements were removed in the first step, Ga fraction
20
still contained Fe and Mo, requiring a second purification, which was done on the column charged
21
with Ln-spec resin. The detail procedure was described in the text.
22
6
ACS Paragon Plus Environment
Page 7 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
23
Figure 2. The assessment of the influence of Ba (A), Ce (B), Cu (C), Zn (D), Fe (E) and Mo (F)
24
on Ga isotopic measurements. The δ71Ga data was the average value of 5 replicate analyses, and
25
the error bars represented the 2SD uncertainty of all measurements. The effect of Fe and Mo were
26
investigated on both Nu Plasma II (red dots) and Neptune Plus (blue rhombi) machines.
27
7
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 40
28
Figure 3. Reproducibility of Ga isotope ratio (δ71Ga) for long-term measurements of the standard
29
GBW(E) 08056 on the Nu Plasma II (A, red dots) and the Neptune Plus (B, blue rhombi) using
30
SSB correction method, respectively. The dashed lines and solid line represented the external
31
long-term standard deviations (2SD) and mean for all tests, respectively. The error bars (2SD)
32
were also given for each measurement and were generally better than 0.05‰.
33 34
8
ACS Paragon Plus Environment
Page 9 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
35 36
Figure 4. Standard addition experiment for validation of the whole purification and isotopic
37
analysis protocol. The experiment was carried out on six mixture solutions of GBW(E) 08056 Ga
38
and NIST 994 Ga. The δ71Ga values measured here (red points with red error bars, n = 5) for the
39
two pure standards (0.00 ± 0.05‰ and 1.75 ± 0.06‰) were consistent with the results (0.00 ± 0.04‰
40
and 1.74 ± 0.05‰) of long-term measurements. The linear fit attested the accuracy of Ga isotope
41
analysis. The blank dotted lines were the confidence interval of 6 measurements at 95%
42
confidence levels.
43 44 45
9
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
46
Page 10 of 40
for TOC only:
47 48
10
ACS Paragon Plus Environment
Page 11 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
Precise analysis of Gallium isotopic composition by MC-ICP-MS
2
Wei Yuan ab, JiuBin Chen *a, Jean-Louis Birck c, ZuoYing Yin a, ShengLiu Yuan ab,
3
HongMing Cai ab, ZhongWei Wang ab, Qiang Huang a and ZhuHong Wang a
4
a
5
Academy of Sciences (IGCAS), Guiyang 550081, China.
6
b
7
c
8
75252 Paris, France
9
* Corresponding author.
10
State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese
University of Chinese Academy of Sciences, Beijing 100049, China
Laboratoire de Géochimie et Cosmochimie, Institute de Physique du Globe de Paris (IPGP),
E-mail:
[email protected] Tel.: +86 851 85892669
11
1
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 40
12
ABSTRACT: Though an isotope approach could be beneficial for better
13
understanding the biogeochemical cycle of Gallium (Ga), an analogue of the
14
monoisotopic element aluminum (Al), the geochemistry of Ga isotopes has not been
15
widely elaborated. We developed a two-step method for purifying Ga from geological
16
(biological) samples for precise measurement of Ga isotope ratio using multi-collector
17
inductively coupled plasma mass spectrometry (MC-ICP-MS). Ga was thoroughly
18
separated from other matrix elements using two chromatographic columns loaded
19
with AG 1-X4 and Ln-spec resin, respectively. The separation method was carefully
20
calibrated using both synthetic and natural samples and validated by assessing the
21
extraction yield (99.8 ± 0.8%, 2SD, n = 23) and the reproducibility (2SD uncertainty
22
better than 0.05‰, n = 116) of the measured isotopic ratio (expressed as δ71Ga). The
23
validation of the whole protocol, together with instrumental analysis, was confirmed
24
by the investigation of the matrix effect, the result of a standard addition experiment
25
and the comparison of Ga isotope measurement on two mass spectrometers Nu
26
Plasma II and Neptune Plus. While the measurements using the sample-standard
27
bracketing (SSB) correction method on both instruments resulted in identical δ71Ga
28
values for reference materials, the modified empirical external normalization (MEEN)
29
method gave relatively better precision compared to SSB on Neptune. Our
30
preliminary results showed large variation of δ71Ga (up to 1.83‰) for ten standards,
31
with higher values in industrially produced materials, implying potential application
32
of Ga isotopes.
33 34
2
ACS Paragon Plus Environment
Page 13 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
35
INTRODUCTION
36
Discovered by P. E. Lecoq de Boisbaudran in 18751, Gallium (Ga) is a metallic
37
element close to the non-metals in the periodic table and has special physiochemical
38
characteristics and important economic value, thus is of great interest in many
39
research aspects. Over the past decades, significant advancements about Ga
40
geochemistry have been achieved based mainly on the analysis of Ga concentration
41
and species. Generally, Ga exists primarily in trivalent state (Ga3+) and its free
42
elemental form (Ga0) is rarely found in nature1,2. As the third element of the Group
43
IIIA, Ga has chemical properties similar to aluminum (Al), and is frequently used as a
44
geochemical analog of Al3-7. However, unlike Al which is a major element, the trace
45
element Ga sometimes behaves differently and the fractionation between Ga and Al
46
(Ga/Al ratio) was usually used to investigate the transport and behaviors of trace
47
elements in the ocean4,5,8,9, rivers5,10, and during weathering processes10,11. The ratio
48
of B/Ga was also employed in paleoclimate research, for example, to distinguish the
49
terrigenous from marine environment12. Though Ga is involved in many biological
50
processes and is detected in almost all plants and even enriched in some certain
51
species, the exact role of Ga in biological metabolism still remains unclear13.
52
Moreover, the distribution of Ga in the mantle and core of the earth may be an
53
indicator of the material source, physiochemical condition and dynamic processes
54
during differentiation14. Ga is also useful in the cosmochemical studies, for example,
55
the concentration measurement of Ga (with other elements) helps to classify iron
56
meteorites15-19. Though these studies significantly improved our knowledge on the Ga
57
geochemistry, many processes and mechanisms involved in the transportation and
58
transformation of Ga in nature remain unidentified and/or unquantified.
59
Economically, Ga is largely used in high-tech applications2,20, including electronics,
60
the missile industry and the power sector21-23. The wide application of Ga in human
61
activities would not only lead to a growing demand for Ga, resulting in the urgent
62
exploration of more potential sources beside bauxite or purification and enrichment
63
techniques for low level minerals24-26, but also modify the biogeochemical cycle of Ga 3
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 14 of 40
64
by for example increasing the continental input of Ga to the ocean. Thus, more
65
research is required to better constrain the anthropogenic impact on the
66
biogeochemical cycle of Ga.
67
Since the last decade, the development of multi-collector inductively coupled
68
plasma mass spectrometry (MC-ICP-MS) and the analyte purification techniques have
69
allowed for accurate and precise measurements of isotopic ratios of many metals27-32,
70
which significantly improved our knowledge on different sectors of earth science.
71
Theoretical, experimental and applicable studies have reported large variations of
72
metal stable isotope ratios in a variety of environments, and shown significant
73
fractionation of these isotopes induced by many biogeochemical processes, such as,
74
adsorption33,34, biological uptake35-38, diffusion39, precipitation40-43 and weathering44.
75
A Ga isotope approach could also provide a better understanding of Ga geochemistry.
76
Ga has two stable isotopes, 69Ga and 71Ga, with the abundances of 60.1% and 39.9%,
77
respectively19. Previous studies have demonstrated that the species as well as the
78
chemical bond (and lattice) that incorporate Ga could change under different
79
geological conditions (pH, temperature, etc.), or be modified in many physiochemical
80
processes6,7,45-47. These changes or processes may fractionate Ga isotopes and thus
81
induce different Ga isotopic signatures in diverse geological (and biological)
82
reservoirs. Ga isotopic composition may be also modified by some specific biological
83
processes, for example, the preferential uptake and accumulation of Ga by some
84
lichens and mosses than other plants could induce different isotopic effects13. Thus,
85
Ga isotopes may be useful for variable studies of its geochemical behaviors in nature.
86
However, apart from several comparative studies on the abundance and distribution of
87
Ga isotopes around the middle of last century19,48-52, the geochemistry of Ga isotopes
88
has not been widely elaborated up to now, due to probably the lack of an effective and
89
reliable method for separating Ga from complex matrices and measuring Ga isotope
90
ratio on the new generation mass spectrometers (MC-ICP-MS).
91
This work is devoted to a new chromatographic method to purify Ga from
92
geological (biological) samples for precise measurement of Ga isotopic composition
93
on MC-ICP-MS. The two -stage separation method is based on a series of tests using 4
ACS Paragon Plus Environment
Page 15 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
94
various types of elution and even resin, and carefully calibrated by assessing the
95
extraction yield and the reproducibility of the measured isotopic ratio. The whole
96
protocol, together with instrumental analysis is validated by the investigation of the
97
matrix effect, the results of a standard addition experiment and the comparison of Ga
98
isotope measurement on two mass spectrometers (Nu Plasma II and Neptune Plus).
99
EXPERIMENTAL SECTION
100
Materials and Reagents. All materials and reagents including resins, Milli-Q
101
water (18.2 MΩ, Millipore, US), oxalic acid solution (made by oxalic powder) and
102
distilled acids (HCl, HNO3 and HF) were prepared in the clean room (Class 100). The
103
anion exchange resin AG1-X4 (200-400 mesh, Bio-rad) and the cation exchange resin
104
Ln-spec (50-100 µm, TrisKem) were used in this study for Ga separation. Both resins
105
were carefully washed with Milli-Q water and the fine floating grains were discarded
106
before loading into the column. All reagent blanks were determined after evaporation
107
of 10 ml solution and were 0.001, 0.001, 0.001, 0.002, 0.002, 0.009, 0.001 and 0.003
108
µg/L for H2O, 0.1 M HCl, 0.5 M HCl, 1M HCl, 4 M HCl, 6 M HCl, 2% HNO3 and “3
109
M HCl + 0.25 M oxalic acid”, respectively, being negligible in comparison to the
110
amounts of Ga in both standards and samples. NIST SRM 994 Ga concentration
111
standard (NIST, US), GBW(E) 08056 industrial synthetic concentrated solution
112
(prepared by Shandong Metallurgical Science Research Institute, China) were used as
113
Ga reference materials. The high pure Ga metal standard, NIST SRM 994, was
114
digested by concentrated HNO3 and HCl with heating, then diluted to 1000 ppm by
115
Mill-Q water. Multi-element standard GBW 081531 (National Institute of Metrology,
116
China), mono-element Fe standard (GBW(E) 080364, The Department of Water
117
Environment, IWHR, China) and Mo standard (GBW(E) 080218, National Institute of
118
Metrology, China) were employed to model natural samples or for matrix effect tests.
119
Cu standard (Alfa Aesar, Germany) was used for mass bias correction in the modified
120
empirical external normalization (MEEN) method. All Teflon labware was cleaned
121
with ultrapure HNO3 and rinsed with Mill-Q water just before their use.
122
Except for GBW(E) 08056 solution, nine reference standards were acid-digested 5
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 16 of 40
123
for the measurements of Ga isotope compositions. Except for the in-house Ga
124
standard solution (GBW(E) 08056), eight reference materials, including JB-2 (basalt),
125
JG-2 (granite), BHVO-2 (basalt), G-2 (granite), GXR-2 (soil), GXR-3 (Hot springs
126
deposit), MAG-1 (marine mud), GBW07405 (soil) and one Gallium (III) nitrate
127
hydrate (Alfa Aesar, Germany) were also prepared and measured for δ71Ga against the
128
international standard NIST 994 Ga. Before analysis, 100 mg of these geological
129
materials were digested with first 4 ml concentrated HNO3 and HF (1:1) in Teflon
130
vials (48 h at 140 ℃), then 1 ml concentrated HNO3 and finally 1 ml 6 M HCl,
131
respectively. After dryness, the last residue was dissolved in 1 ml 6 M HCl and ready
132
for the column chemistry. Elemental concentrations were measured on ICP-MS
133
NexlON 300X (PerkinElmer®, US), with the precision better than 5% (2SD) based on
134
repeated analysis of the geostandard SLRS-5.
135
Ga separation protocol. For precise Ga isotope measurement, it was crucial to
136
thoroughly separate Ga from the matrix and other elements in natural samples,
137
especially from Mg, Al, Fe, Ba, Ce, Cr and Zn, because the presence of these elements
138
could generate spectral effects on Ga isotopes in argide form (Mg, Al), hydro form
139
(Zn) (hydro)-oxide form (Cr, Fe) and double-charged species (Ba, Ce) (see below
140
“Matrix effect on Ga isotopic measurement”). For ensure matrix-matched principle on
141
Ga isotopic measurement Mo and Cu, which often present in natural samples, should
142
also be separated from Ga30,53. The protocol was composed of two chromatographic
143
steps: the first step for purifying Ga from most major and minor elements, and the
144
second step for separating Ga from Fe and Mo, respectively. The elution scheme for
145
the whole purification process was summarized in Table 1. Both steps were carried
146
out on a polypropylene column (inner diameter 0.8× 4 cm, length 9 cm, Bio-Rad).
147
For the first step, the column charged with 1.8 ml AG1-X4 resin was first rinsed
148
with 10 ml H2O and 10 ml 0.1 M HCl, then conditioned with 10 ml 6 M HCl, the
149
sample was loaded in 6 M HCl afterwards. After rinsing with 10 ml 6 M HCl, Ga was
150
eluted in 5 ml 0.5 M HCl. Since this Ga elution still contained substantial amounts of
151
Fe and Mo (measured by ICP-MS), a second purification was required.
152
Table 1 6
ACS Paragon Plus Environment
Page 17 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
153
The second separation of Ga from Fe and Mo was achieved on the column loaded
154
with 1.4 ml Ln-spec resin. The column was conditioned with 10 ml 0.5 M HCl. The
155
previously obtained 5 ml Ga-contained 0.5 M HCl solution was loaded onto the
156
column. Because Mo and Fe were well retained by the Ln-spec resin but not Ga, the
157
liquid passed through the column was immediately collected into Teflon vial. Another
158
6 ml 1 M HCl was introduced to elute the rest of Ga still retained in the resin into the
159
same Teflon vial. The 11 ml Ga elution was further evaporated to dryness and the
160
residual was dissolved in 2% HNO3 for isotope and concentration measurements. To
161
reuse the Ln-spec resin, the column was cleaned by 20 ml mixed solution of 0.25 M
162
oxalic acid and 3 M HCl, 20 ml 0.1 M HCl and 20 ml 4 M HCl to strip Fe and Mo.
163
The total procedure blank was 0.3 ng for the whole protocol and 0.2 ng and 0.1 ng for
164
the first and the second steps, respectively, being negligible compared to the mass (at
165
least 200 ng and 80 ng on Nu and Neptune MC-ICP-MS, respectively) needed for a
166
precise isotope analysis.
167
Ga isotope measurement on the Nu MC-ICP-MS. Ga isotope measurement was
168
performed on the Nu Plasma II MC-ICP-MS (Nu Instruments Ltd., UK) at the
169
Institute of Geochemistry, Chinese Academy of Sciences (IGCAS). The Ga standards
170
and samples were measured in 2% HNO3, and the concentration of Ga was fixed to 50
171
µg/L.
172
The instrument setting was shown in Table 2. For the cups configuration, mass
173
dispersion was adjusted to allow collection of two Ga isotopes (69Ga and 71Ga), three
174
Zn isotopes (66Zn,67Zn,68Zn) and four double-charged isotopes including 135Ba2+,
175
137
176
was used as sample introduction system and the low-resolution entrance slit was
177
chosen throughout the study. The instrumental baseline and peak centering were done
178
before every sample (standard) analysis. Each measurement included 60 integrations
179
of 6s in 5 blocks of 12 cycles, followed by a 3-minutes washing with 0.5 M HNO3 to
180
lower the Ga signal to insignificant level (< 1 mV). The instrumental sensitivity was
181
about 7 V on 69Ga for a 50 µg/L solution. In this study, the sample-standard bracketing
182
(SSB) method was employed to correct the mass bias for all measurements, because
Ba2+, 140Ce2+ and 146Ge2+ in variable cups. An Aridus II desolvator (CETAC, USA)
7
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 18 of 40
183
our Nu instrument mostly had a perfect stability, as reported in previous study30,53. Ga
184
isotope results in this study were expressed as δ71Ga, in units of per mil (‰):
185
δ71Ga = [(71Ga/69Ga)sample / (71Ga/69Ga)standard – 1] × 1000
186
here we chose the NIST SRM 994 solid metal Ga as the reference standard, as it was
187
well calibrated (Ga69/71 = 1.50676 ± 0.00039, at 95% confidence interval) and adopted
188
for an ideal international standard purpose54-56.
189
Table 2
(1)
190
Comparison between Nu and Neptune instruments. Ga isotope measurement
191
was also carried out on a Neptune Plus mass spectrometer, another commonly used
192
instrument for comparison. This was done on the Neptune Plus (Thermo Finnigan®,
193
Germany) at the Institute de Physique du Globe de Paris (IPGP), France. The machine
194
setting of Neptune Plus was summarized in Table 3. The desolvator Apex HF (without
195
nitrogen flow) was instead employed as sample inlet system, equipped with a
196
self-aspiring microconcentric PFA nebulizer. The samples (standards) were measured
197
also in 2% HNO3, but the Ga concentration was set to 20 µg/L, because the Neptune
198
Plus had a better sensitivity (8V on 69Ga for a 20 µg/L solution) compared to the Nu
199
Plasma II. Limited by the detector configuration of this particular Neptune Plus, the
200
Faraday cups were set for measuring two Ga isotopes (69Ga,
201
(63Cu,
202
isotope (137Ba2+) (see Table 3).
65
Cu), three Zn isotopes (66Zn,
67
Zn,
70
71
Ga), two Cu isotopes
Zn), and only one double-charged Ba
203
Table 3
204
In addition to the conventional SSB, the modified empirical external normalization
205
(MEEN) method that has been well described and used in previous studies was also
206
employed for the mass bias correction on the Neptune Plus27,30,31,57-59. The general
207
observation from these studies was that, though SSB and MEEN gave similar results
208
for mass bias correction under relatively stable instrumental conditions (the case of
209
our Nu Plasma II), MEEN approach produces better precision when the Neptune
210
instrument was not very stable due to for example the instability of Apex
211
desolvator30,53,54. Two previous studies have reported the usefulness of Ga for
212
correcting mass bias in Cu and Zn isotope analysis60,61 Here, Cu was alternatively 8
ACS Paragon Plus Environment
Page 19 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
213
employed for the correction during Ga isotope determination. In this method, the AAS
214
Cu solution provided by IPGP (France)30 was used with the radio of Ga/Cu of 0.5 at
215
Ga concentration of 20 µg/L.
216
Results and discussion
217
The efficiency and reproducibility of Ga separation protocol. Ga was separated
218
from the geological matrix by two ion-exchange chromatography steps: a first
219
pre-concentration using AG 1-X4 resin and a second purification on the special
220
Ln-spec resin. The anion-exchange resin AG1-X4, which was a lower cross-linked
221
(4%) resin, has been successfully used to separate target elements such as Fe, Zn and
222
Hg from natural sample30,31,62. In this study, the resin volume was set to 1.8 ml to give
223
a compromise between a good purification (partially depending on the volume) and
224
the short elution time. The theoretical capacity of AG1-X4 resin was 1 meq/ml, thus
225
with 1.8 ml resin, 41.4 mg Ga3+ could be retained, which allows for separating Ga
226
from a large amount of geological samples, given the average Ga abundance of 17
227
ppm in the Earth Crust1.
228
For precise Ga isotope measurement, the identical matrix should be guaranteed
229
between standard and sample, thus natural samples need to be thoroughly purified,
230
with a particular goal of separating Ga from major (e.g. Fe) and trace elements such as
231
Ba, Ce, Zn, Cu, and Mo (see below discussion on the matrix effect). To establish an
232
appropriate elution scheme, the solution volume Velu needed for eluting the target
233
element can be calculated using the following equation:
234
V = V + M × Kd
235
where V0 is the dead volume of resin, M is the dry mass of resin, and Kd is the
236
partitioning coefficient of Ga in a given solution, defined as63:
237
Kd =
/ /
(9)
(10)
238
In hydrochloric acid medium, the partitioning coefficient Kd of Ga3+ between
239
AG1-X4 resin and the solution increase correspondingly64. As Kd was already higher
240
than 5×104 at 6 M HCl, we chose to load samples in this acidity in order to avoid the
241
volatility of concentrated HCl (> 7 M). Theoretically, 50 L of 6 M HCl could be 9
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 20 of 40
242
introduced into the column before Ga breakthrough. The Kd of Ga3+ was below 5 at
243
0.5 M HCl, thus Ga could be eluted in about 5 ml 0.5 M HCl. In order to test the
244
above theoretical calculations, a series of experiments were carried out on both
245
synthetic and natural sample solutions and element concentrations were measured for
246
every elution fraction collected 1 ml by 1 ml. The primary elution curves showed that
247
major elements, such as Na, Mg, Ba and Ca, were not retained by the resin at 6 M
248
HCl (Figure 1A). Figure 1A
249 250
However, almost all of Fe and some of Mo went into the 0.5 M Ga fraction (Figure
251
1A), because of the similar partition coefficient for Fe3+ and Mo6+
252
medium, their Kd were of about 104 and 5×102 at 6 M HCl , and both below 5 at 0.5
253
M HCl, respectively. A further separation step is thus needed to separate Ga from Fe
254
(and Mo). We first attempted to use the same resin (AG1-X4) to achieve this
255
separation by changing the concentration or kind of acid, and by adding other
256
reactants. Though the small Kd difference between Fe3+ and Ga3+ signified a
257
possibility to well separate these two elements by modifying the HCl concentration (1
258
M ~ 2 M), our experimental data showed that Fe3+ was promptly and almost
259
simultaneously eluted in Ga3+ solution. Alternatively, we performed the elution using
260
nitric acid and got similar results. Since the Kd of Fe2+ was very different from Ga3+
261
in HCl solution, we then tried to transfer Fe3+ to Fe2+ in column by adding reductants,
262
(ascorbic acid and hydrazine dihydrochloride), but the
263
of Fe3+ was reduced to Fe2+, likely caused by the loss of reducing ability for these
264
reductants in relatively concentrated acid. Finally, we tried to modify the Kd of metals
265
(here Ga, Fe and Mo) to get a good Ga isolation by adding oxalic acid, which
266
generally forms strong metal complexes in HCl elution65, . The tests showed that this
267
addition did change the Kds, but failed to achieve a complete separation, (Fe trailing
268
in Ga elution). Thus, another chromatographic column loaded with different resin
269
should be chosen and employed.
270 271
in the same HCl
results showed that only part
We first chose the column charged with 1.2 ml cation exchange AG 50W-X12 resin (200-400 mesh, Bio-rad) that was widely used
for separating metals in HF 10
ACS Paragon Plus Environment
Page 21 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
272
medium66. Though Ga would theoretically beseparated from Fe on this resin in dilute
273
HF, the tests using 1 M or 1.5 M HF for both loading and eluting showed that,
274
although most of Fe3+ was eventually eluted prior to Ga3+, there was still a small Fe3+
275
fraction present in the following Ga eluent.
276
Finally, the Ln-spec resin that was commonly used to separated radium and
277
lanthanides from geological samples67. Given the theoretical capacity of 0.16
278
mmol/ml for this resin, up to 15 mg Ga could be retained with a resin volume of 1.4
279
ml. Interestingly, Ga3+,Fe3+ and Mo6+ displayed quite different Kd on this resin in
280
dilute HCl or HNO3 medium, for example, their Kds were about 0.3 (Ga3+) and 5×103
281
(Fe3+) at 0.5 M HCl, and 0.8 (Ga3+), 5×103 (Fe3+) and 7×102 (Mo6+) at 0.5 M HNO3,
282
respectively. In fact, the specific "phosphoric acid" from the Ln-Spec resin form more
283
stable complexes with Fe (having incomplete “d” electron shell) than Ga (with
284
complete “d” electron donor). Loading in 0.5 M HCl, Fe3+ (and Mo6+) could be
285
retained by the resin but Ga3+ should directly go through. Thus, the last 0.5 M HCl
286
elution containing Ga, Fe and Mo from the first pre-concentration step could be
287
loaded directly on the Ln-spec column without any additional step (e.g. evaporating to
288
dryness and/or changing the acid medium), which allowed for completing the two step
289
separation in a single day. However, the first tests showed that a small fraction of Ga3+
290
still remained in the Ln-spec resin posterior to the loading, requiring another eluent.
291
We chose 6 ml 1 M HCl to elute the remained Ga3+, because at 1 M HCl, the Kd of
292
Ga3+ reached its minimum value of about 0.2, much lower than that of Fe3+ (about
293
103). The concentration measurement showed that Fe and Mo were still retained on
294
the Ln-spec resin and were not found in the 11 ml (5 ml loading 0.5 M HCl plus 6 ml
295
1 M HCl eluent) Ga fraction at all (Figure 1B). Finally, in order to reuse the Ln-spec
296
resin and avoid the possible presence of Fe (and Mo) in Ga fraction65, a mixture of
297
0.25 M oxalic acid and 3 M HCl was used to elute all Mo and most of Fe, the rest of
298
Fe was further removed from the column in 4 M HCl, because the Kd of Fe in this
299
acid medium was the lowest (about 15). A 0.1M HCl solution was inserted before 4 M
300
HCl to clean the possible presence of other elements (such as REEs) (Table 1).
301
Figure 1B 11
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 22 of 40
302
In order to check the recovery of Ga, a series of experiments (n = 23) were done
303
using our purification protocol on synthetic solutions (5 ng to 100 µg GBW(E) 08056
304
Ga mixed with other elements such as Fe, Mo, Ba, Na, Zn, etc.). The recoveries of Ga
305
varied from 98.8% to 100.6% with a mean value of 99.8 ± 0.8% (2SD, n=23). Except
306
for some synthetic samples with very low Ga concentration (< 200 ng), Ga isotopic
307
ratios were measured on the Nu Plasma II instrument (see “the measurement of Ga
308
isotopes of reference materials” section) for all elution derived from the above tests.
309
The results showed that δ71Ga varied from 1.69‰ to 1.78‰, averaging 1.74 ± 0.05‰
310
(2SD, n=21).
311
Matrix effect on Ga isotopic measurement. The effect of matrix such as Ga
312
concentration and other species that may interfere Ga isotopic measurement were
313
systematically investigated. The primary experiments on varying Ga concentration
314
from 5 µg/L to 50 µg/L showed that the Ga content should be set to higher than 20
315
µg/L, because a continuous decrease of δ71Ga with Ga concentration down to 5 µg/L
316
was determined, probably due to the instrumental blank effect, as reported in previous
317
work30.
318
Removing the possible spectral interferences derived from elemental isobars, major
319
argides, trace oxides and doubly-charged species was another critical issue for precise
320
Ga isotopic analysis. The potential spectral interferences were summarized in Table 4.
321
According to this table, Ga should be thoroughly separated from elements such as Ba,
322
Ce, Zn, Fe, because they may generate spectral interferences in doubly-charged
323
species (138Ba2+,
324
70
325
138
Ce2+ and
142
Ce2+) or polyatomic forms (54Fe16O1H+,
68
Zn1H+ and
Zn1H+). Table 4
326
Though our two-step method would well purify Ga from other major and trace
327
elements, we still investigated the effect of the possible presence of certain elements
328
such as Ba, Ce, Cu, Zn, Fe and Mo on Ga isotope measurements. This was done by
329
fixing Ga concentration to 50 ppb and by changing the ratios of element/Ga (thus the
330
percentage) in standard solutions. As shown in Figure 2A and Figure 2B, the presence
331
of Ba and Ce induced a significant deviation of δ71Ga from the actual value (around 12
ACS Paragon Plus Environment
Page 23 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
332
zero) of the initial Ga standard. This is caused by the doubly-charged interferences of
333
138
334
result in lower and higher δ71Ga values, respectively. Therefore, Ga isotope analysis
335
should be done on solutions absolutely free of Ba and Ce. In the study, the final Ga
336
eluent from the two-column purification contained hardly any Ba and Ce. The effects
337
of the presence of Cu, Zn, Fe and Mo on δ71Ga were also shown in Figure 2C to 2F.
338
Unlike Ba and Ce, no clear influence was found within the measurement uncertainty
339
(0.05‰, see below) for the given element/Ga ratio range, except for Zn that could
340
interfere with Ga isotopes in hydride forms (68ZnH+ and
341
Zn/Ga was higher than 10%. The fact that the abundance of
342
higher than 70Zn (0.62%) might explain the lower δ71Ga values in test solutions with
343
higher Zn/Ga ratio (> 10%), supposing that both Zn isotopes trended to equally form
344
hydrides. In fact, the concentration ratios of Cu/Ga, Zn/Ga, Fe/Ga and Mo/Ga in the
345
last elution of all tests were very small (far below 2%) for both synthetic and sample
346
solutions, implying no significant impact on Ga isotopic measurement. The tests on
347
the Neptune gave similar results to those on Nu instrument (Figure 2E and 2F).
348
Finally, our measurement data showed no argide interferences (e.g.
349
40
350
mV. Though the presence of Mo did not show clear influence on Ga isotopic
351
measurement (Figure 2F), Mo was removed in our protocol in order to guarantee the
352
identical medium in sample to standard solution and avoid unexpected matrix effect.
353
Ba (71.698)2+,
138
Ce (0.251)2+ on
69
Ga and
142
Ce (11.114)2+ on
70
71
Ga, which would
ZnH+) when the ratio of 68
Zn (18.75%) is much
40
Ar29Si+ and
Ar15N16O) on Ga isotopes, as the background Ga level was generally lower than 0.1
Figure 2
354
The validation of Ga isotopic measurement. The standard GBW(E) 08056 was
355
calibrated against the international standard NIST 994 Ga and was measured regularly
356
as in-house standard on the Nu plasma II to control the analysis quality. The Figure
357
3A showed the results of δ71Ga for 116 measurements in one year. All measurements
358
gave an average δ71Ga of 1.74‰ with a long-term external 2SD uncertainty of 0.05‰
359
(Figure 3A). In order to confirm the accuracy and precision of this calibration (Ga
360
isotopic measurement), a standard addition experiment, similar to a previous study68,
361
was carried out by making six mixture solutions of GBW(E) 08056 Ga and NIST 994 13
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 24 of 40
362
Ga, with GBW(E) 08056 Ga proportions of 0% (pure NIST 994 Ga solution), 10%,
363
20%, 50%, 80%, and 100% (pure GBW(E)08056 Ga), respectively. The Ga isotope
364
ratio (and concentration) of all mixtures was measured on Nu MC-ICP-MS using the
365
SSB method. The results showed similar δ71Ga values for both pure standards as the
366
long-term measurements, and more important, a linear correlation between δ71Ga and
367
Ga fraction with the correlation coefficient (R2) of 0.997 (Figure 4), attesting the
368
accurate analysis of this in-house standard and that the use of SSB method for mass
369
bias correlation was adequate.
370
Figure 3A, Figure 4
371
Application to the reference materials. Ga was carefully purified from the ten
372
standards using our newly-developed protocol and Ga isotopic composition was
373
measured on either Nu or Neptune ICP-MS or both (Table 5). As seen in Table 5, our
374
shorter-term measurements gave the external 2SD uncertainty of < 0.05‰ for all
375
samples, comparable to the long-term reproducibility (0.05‰, 2SD, n = 116, Figure 3).
376
As a whole, all reference materials displayed a large δ71Ga variation of about 1.83‰,
377
with generally higher values for standards of industrial processes than natural
378
geological materials. Though the exact mechanism enriching heavier Ga isotopes in
379
industrial materials remains unknown, the large difference of δ71Ga between artificial
380
standards and natural materials implies the usefulness of Ga isotopes in studying some
381
aspects of Ga geochemistry, for example for distinguishing natural from
382
anthropogenic sources.
383
Table 5
384
Nu vs. Neptune. For comparison, Ga isotope measurement was carried out on both
385
Nu and Neptune MC-ICP-MS, but with completely different instrumental setting (see
386
Table 2 and Table 3). Concomitant with the best optimization (tuning) of instrument
387
conditions, the Neptune had a better sensitivity (e.g. 8V on 69Ga for 20 µg/L solution)
388
compared to the Nu ICP-MS (about 7 V on
389
Neptune consumed relatively less Ga mass (to give the same signal intensity and
390
results with good precision, see below) and was more adaptable for dilute samples.
391
Regarding the reference control, the cup configuration and the collector design of the
69
Ga for a 50 µg/L solution). Thus the
14
ACS Paragon Plus Environment
Page 25 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
392
Nu Plasma II at IGCAS allowed for measuring more isotopes (nine isotopes, Table 2)
393
than the Neptune Plus at IPGP (eight isotopes, Table 3). An especially important point
394
was the ability to measure
395
interferences of
396
complete removal of Ce must be guaranteed, or sample solution must be scanned prior
397
to Ga isotopic analysis on Neptune.
138
Ce2+ and
140
Ce2+ on the Nu Plasma II allowed recognition of the
142
Ce2+ on Ga isotopes (Figure 2B, Table 4). Therefore,
398
Despite the above mentioned difference, 53 measurements of GBW(E) 08056 Ga
399
using the SSB method on the Neptune displayed similar reproducibility (long-term
400
2SD < 0.05‰) as the Nu instrument (Figure 3B, Table 5). Moreover, the analysis of
401
four reference materials (JB-2, BHVO-2, Ga nitrate and GBW(E) 08056) on Neptune
402
using the same SSB correction gave almost identical δ71Ga values to those on Nu
403
(Table 5), implying that Ga isotope ratio can be readily measured on both instruments.
404
The Table 5 also showed that, though measured on the same Neptune ICP-MS at IPGP,
405
for the four references, the MEEN correction method gave relatively better precision
406
(0.02 to 0.03‰) than the SSB method (0.03 to 0.06‰). Figure 3B
407 408
CONCLUSION
409
The new two-step method allows for separating Ga from complex geological matrix,
410
especially from elements such as Ba, Ce, Zn, Cu, and Fe that may interfere with Ga
411
isotope measurement. The separation protocol was thoroughly calibrated and
412
optimized using both synthetic and natural samples, and has been proven to be
413
reproducible and satisfactory for precise Ga isotope ratio determination on
414
MC-ICP-MS. The short-term analysis performed on both Nu and Neptune
415
spectrometers gave identical δ71Ga values for natural materials, and a precision better
416
than 0.05‰, comparable to that (0.05‰, 2SD, n = 116) of the long-term in-house
417
standard calibration. Our preliminary results revealed large variation of δ71Ga (up to
418
1.83‰) in ten natural and industrial reference materials, stimulating further
419
investigation of Ga isotopic composition in natural reservoirs and the relative
420
fractionation mechanisms. The application of isotope approach would provide new 15
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
421
insight into the study of the geochemistry cycle of Ga.
422
ACKNOWLEDGMENTS
Page 26 of 40
423
This work was financially supported by the Natural Science Foundation of China
424
(U1301231, 41561134017) and the State Key Laboratory of Environmental
425
Geochemistry, IGCAS (SKLEG2016001). The authors acknowledge the associate
426
editor R. Niessner, reviewer T. Bullen and the anonymous referee who greatly
427
improved the quality of the manuscript. This is IPGP contribution No. XXX.
428 429
Figure captions:
430
Figure 1. Elution curve of Ga separation from matrix on the AG 1×4 resin (A) and the Ln-spec
431
resin (B). Though most of the major and trace elements were removed in the first step, Ga fraction
432
still contained Fe and Mo, requiring a second purification, which was done on the column charged
433
with Ln-spec resin. The detail procedure was described in the text.
434 435
Figure 2. The assessment of the influence of Ba (A), Ce (B), Cu (C), Zn (D), Fe (E) and Mo (F)
436
on Ga isotopic measurements. The δ71Ga data was the average value of 5 replicate analyses, and
437
the error bars represented the 2SD uncertainty of all measurements. The effect of Fe and Mo were
438
investigated on both Nu Plasma II (red dots) and Neptune Plus (blue rhombi) machines.
439 440
Figure 3. Reproducibility of Ga isotope ratio (δ71Ga) for long-term measurements of the standard
441
GBW(E) 08056 on the Nu Plasma II (A, red dots) and the Neptune Plus (B, blue rhombi) using
442
SSB correction method, respectively. The dashed lines and solid line represented the external
443
long-term standard deviations (2SD) and mean for all tests, respectively. The error bars (2SD)
444
were also given for each measurement and were generally better than 0.05‰.
445 446
Figure 4. Standard addition experiment for validation of the whole purification and isotopic
447
analysis protocol. The experiment was carried out on six mixture solutions of GBW(E) 08056 Ga
448
and NIST 994 Ga. The δ71Ga values measured here (red points with red error bars, n = 5) for the
449
two pure standards (0.00 ± 0.05‰ and 1.75 ± 0.06‰) were consistent with the results (0.00 ± 0.04‰ 16
ACS Paragon Plus Environment
Page 27 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
450
and 1.74 ± 0.05‰) of long-term measurements. The linear fit attested the accuracy of Ga isotope
451
analysis. The blank dotted lines were the confidence interval of 6 measurements at 95%
452
confidence levels.
453 454
Table captions:
455
Table 1. Elution sequence of the two-step separation Eluant
Volume(ml)
Eluted
First column charged with 1.8 ml AG1-X4 resin H2O 0.1 M HCl 6 M HCl Sample (6 M HCl) 6 M HCl 0.5 M HCl
10 10 10 1 10 5
Cleaning Cleaning Cleaning + Conditioning Loading Matrix Ga (Fe and Mo)
Second column charged with 1.4 ml Ln-spec resin 0.5 M HCl 0.5 M HCl sample solution 1 M HCl
10 5 6
Conditioning loading + Ga Ga
0.25 M Oxalic acid + 3 M HCl 0.1 M HCl 4 M HCl
20 20 20
Cleaning (Mo, Fe) Cleaning Cleaning (Fe)
456 457
17
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 28 of 40
458 459
Table 2. Nu Plasma II ICP-MS Operating Conditions Component
parameter
Stage control Vocuum Capacitor Gas Panel
Back / Forward: 8.83; In / Out: 3.97; Up/Down: 2.93 Lighting: 2330; Running: 2160 Coolant (L/min): 13.0; Aux (L/min): 0.80; Neb (Psi): 27.6; Mix Gas (L/min): 0.00; Mix Gas 2 (L/min): 0.00 Forward (W): 1300 Quad1: 6.3; Quad2: 74.5 HV1: 5999; HV2: 4412; HV3: 3671; HV4: 1700; HV5: 2814; HV6:2408 146 Ge2+ (H7); 71Ga (H4); 140Ce2+ (H2); 69Ga (Ax); 137Ba2+ (L1); 68 Zn (L2); 135Ba2+ (L3); 67Zn (L4); 66Zn (L5)
RF Power Quads High Voltage Faraday cups setting
460 461
18
ACS Paragon Plus Environment
Page 29 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
462 463
Table 3. Neptune Plus ICP-MS Operating Settings Component Zoom Optics Parameter Center Cup Source lenses Inlet System
Faraday cups setting
Parameter Focus Quad [V] :10.00; Dispersion Quad [V] :0.00 Decelerator [V]:8199.9; Suppressor [V]:9965.0 Extraction [V] :-2000; Focus [V] :-611.0; X-Defl [V] :6.49; Y-Defl [V]:-4.30; Shape [V]:206.00 Rot Quad [V]:18.93; Source Offset [V]:-6.00 Cool gas [L/min]:16.00; Aux Gas [L/min] :0.88; Sample Gas [L/min]:1.065; Add. Gas1 [L/min]:0.00; Add. Gas 2 [L/min]: 0.00; X-Pos [mm]:0.010; Y-Pos [mm] :-3.300; Z-Pos [mm] :-1.850; Peri.Pump [rpm] :5.00; RF Power [W]:1200 71 Ga (H4); 70Zn (H3); 69Ga (H2); 137Ba2+ ( H1); 67Zn (RPQ/IC1); 66 Zn (L1); 65Cu (L2); 63Cu (L4)
464
19
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 30 of 40
465 466
Table 4. Potential species interfering Ga isotope measurement on MC-ICP-MS Species
Mass-69
Mass-71
Monoisotopic species Argides (Hydro)-Oxides
69
71
Elemental species Double-charged species
Ga 40 Ar29Si+, 37Cl16O2+ 51 18 + 52 V O , Cr17O+, 68Zn1H+, 50 Ti 18O1H+, 50V 18O1H+, 50 Cr 18O1H+, 51V17O1H+, 52 Cr16O1H+, 33 36 S S 138 Ba2+, 138La2+, 138Ce2+
Ga Ar15N16O 53 Cr18O+, 54Cr17O+, 55Mn16O+, 54 Fe17O+, 70Zn1H+, 52Cr18O1H+, 53 Cr17O1H+, 54Cr16O1H+, 54 Fe16O1H+ 40
142
Nd2+, 142Ce2+
20
ACS Paragon Plus Environment
Page 31 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
467 468
Analytical Chemistry
Table 5. Results of comparison between Nu and Neptune mass spectrometers δ71Ga-SSB (‰)
Sample JB-2 (basalt) BHVO-2 (basalt) Gallium (III) nitrate hydrate GBW(E) 08056 G-2 (Granite) JG-2 (Granite) MAG-1 (Marine mud) GXR-2 (Soil) GXR-3 (Deposit) GBW 07405 (Soil) 469 470
δ71Ga-MEEN (‰)
Nu (mean ± 2SD)
Neptune (mean ± 2SD)
Neptune (mean ± 2SD)
0.11 ± 0.03 (n=9) 0.08 ± 0.02 (n=9 ) 1.83 ± 0.04 (n=10) 1.74 ± 0.05 (n=21) 0.03 ± 0.03 (n=5) 0.02 ± 0.03 (n=3) 0.06 ± 0.04 (n=5) 0.04 ± 0.05 (n=4) 0.03 ± 0.05 (n=4) 0.02 ± 0.04 (n=5)
0.10 ± 0.04 (n=10) 0.07 ± 0.03 (n=10) 1.81 ± 0.06 (n=6) 1.73 ± 0.03 (n=5)
0.11 ± 0.02 (n=9) 0.08 ± 0.02 (n=10) 1.82 ± 0.03 (n=9) 1.72 ± 0.02 (n=9)
n, the number of repeated measurements for the same sample including different column procedures (2 or 3). 2SD, 2 times the standard deviation of the population of n repeated measurements
21
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 32 of 40
471 472
REFERENCES
473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513
(1) Shaw, D. M. Physics and Chemistry of the Earth 1957, 2, 164-211. (2) Moskalyk, R. R. Minerals Engineering 2003, 16, 921-929. (3) Burton, J. D.; Culkin, F.; Riley, J. P. Geochimica et Cosmochimica Acta 1959, 16, 151-180. (4) Orians, K. J.; Bruland, K. W. Nature 1988, 332, 717-719. (5) Shiller, A. M. Geochimica Et Cosmochimica Acta 1988, 52, 1879-1882. (6) Diakonov, II; Pokrovski, G. S.; Benezeth, P.; Schott, J.; Dandurand, J. L.; Escalier, J. Geochimica Et Cosmochimica Acta 1997, 61, 1333-1343. (7) Pokrovsky, O. S.; Pokrovski, G. S.; Schott, J. Journal of Colloid and Interface Science 2004, 279, 314-325. (8) Yamamoto, T.; Otsuka, Y.; Uemura, K. Journal of the Oceanographical Society of Japan 1976, 32, 182-186. (9) Orians, K. J.; Bruland, K. W. Geochimica Et Cosmochimica Acta 1988, 52, 2955-2962. (10) Shiller, A. M.; Frilot, D. M. Geochimica Et Cosmochimica Acta 1996, 60, 1323-1328. (11) Hieronymus, B.; Boulegue, J.; Kotschoubey, B. Chemical Geology 1990, 84, 78-82. (12) Chen, Z. Y.; Chen, Z. L.; Zhang, W. G. Quaternary Research 1997, 47, 181-191. (13) Poledniok, J. Chemosphere 2008, 73, 572-579. (14) McDonough, W. F.; Sun, S. s. Chemical Geology 1995, 120, 223-253. (15) Lovering, J. F.; Nichiporuk, W.; Chodos, A.; Brown, H. Geochimica et Cosmochimica Acta 1957, 11, 263-278. (16) Wasson, J. T. Geochimica et Cosmochimica Acta 1967, 31, 161-180. (17) Wasson, J. T.; Kimbeblin, J. Geochimica et Cosmochimica Acta 1967, 31, 2065-2093. (18) Wasson, J. T.; Schaudy, R. Icarus 1971, 14, 59-70. (19) De Laeter, J. R. Geochimica et Cosmochimica Acta 1972, 36, 735-743. (20) Lovik, A. N.; Restrepo, E.; Muller, D. B. Environmental Science & Technology 2015, 49, 5704-5712. (21) Font, O.; Querol, X.; Juan, R.; Casado, R.; Ruiz, C. R.; Lopez-Soler, A.; Coca, P.; Garcia Pena, F. Journal of Hazardous Materials 2007, 139, 413-423. (22) Gupta, B.; Mudhar, N.; Singh, I. Separation and Purification Technology 2007, 57, 294-303. (23) Chou, W.-L.; Wang, C.-T.; Yang, K.-C.; Huang, Y.-H. Journal of Hazardous Materials 2008, 160, 6-12. (24) Katrak, F.; Agarwal, J. JOM 1981, 33, 33-36. (25) Ibragimov, A.; Budon, S. ENRC Annual Report and Accounts 2010. (26) Gladyshev, S.; Akcil, A.; Abdulvaliev, R.; Tastanov, Y.; Beisembekova, K.; Temirova, S. Hydrometallurgy 2013, 140, 95-101. (27) Marechal, C. N.; Telouk, P.; Albarede, F. Chemical Geology 1999, 156, 251-273. (28) Zhu, X. K.; O'Nions, R. K.; Guo, Y.; Belshaw, N. S.; Rickard, D. Chemical Geology 2000, 163, 139-149. (29) Hintelmann, H.; Foucher, D.; Evans, R. D.; Dillon, P. Geochimica Et Cosmochimica Acta 2003, 67, A147-A147. (30) Chen, J.-B.; Louvat, P.; Gaillardet, J.; Birck, J.-L. Chemical Geology 2009, 259, 120-130. (31) Chen, J.-B; Hintelmann, H.; Dimock, B. Journal of Analytical Atomic Spectrometry 2010, 25, 22
ACS Paragon Plus Environment
Page 33 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557
1402-1409. (32) Liu, S.-A.; Teng, F.-Z.; Li, S.; Wei, G.-J.; Ma, J.-L.; Li, D. Geochimica Et Cosmochimica Acta 2014, 146, 59-75. (33) Pokrovsky, O. S.; Viers, J.; Freydier, R. Journal of Colloid and Interface Science 2005, 291, 192-200. (34) Juillot, F.; Maréchal, C.; Ponthieu, M.; Cacaly, S.; Morin, G.; Benedetti, M.; Hazemann, J. L.; Proux, O.; Guyot, F. Geochimica et Cosmochimica Acta 2008, 72, 4886-4900. (35) Weiss, D. J.; Mason, T. F. D.; Zhao, F. J.; Kirk, G. J. D.; Coles, B. J.; Horstwood, M. S. A. New Phytologist 2005, 165, 703-710. (36) Gélabert, A.; Pokrovsky, O. S.; Viers, J.; Schott, J.; Boudou, A.; Feurtet-Mazel, A. Geochimica et Cosmochimica Acta 2006, 70, 839-857. (37) Black, J. R.; Yin, Q.-z.; Rustad, J. R.; Casey, W. H. Journal of the American Chemical Society 2007, 129, 8690-8691. (38) Viers, J.; Oliva, P.; Nonell, A.; Gélabert, A.; Sonke, J. E.; Freydier, R.; Gainville, R.; Dupré, B. Chemical Geology 2007, 239, 124-137. (39) Rodushkin, I.; Stenberg, A.; Andrén, H.; Malinovsky, D.; Baxter, D. C. Analytical Chemistry 2004, 76, 2148-2151. (40) Galy, A.; Bar-Matthews, M.; Halicz, L.; O’Nions, R. K. Earth and Planetary Science Letters 2002, 201, 105-115. (41) Immenhauser, A.; Buhl, D.; Richter, D.; Niedermayr, A.; Riechelmann, D.; Dietzel, M.; Schulte, U. Geochimica et Cosmochimica Acta 2010, 74, 4346-4364. (42) Li, W.; Chakraborty, S.; Beard, B. L.; Romanek, C. S.; Johnson, C. M. Earth and Planetary Science Letters 2012, 333–334, 304-316. (43) Saulnier, S.; Rollion-Bard, C.; Vigier, N.; Chaussidon, M. Geochimica et Cosmochimica Acta 2012, 91, 75-91. (44) Bullen, T. D. 2014. (45) Baes, C. F.; Mesmer, R. E. Hydrolysis of cations; Wiley, 1976. (46) Van Gaans, P.; Oonk, H.; Somsen, G. Journal of Solution Chemistry 1990, 19, 831-854. (47) Benézéth, P.; Diakonov, I. I.; Pokrovski, G. S.; Dandurand, J.-L.; Schott, J.; Khodakovsky, I. L. Geochimica et Cosmochimica Acta 1997, 61, 1345-1357. (48) Aston, F. W. Proceedings of the Royal Society of London. Series A, Mathematical and Physical Sciences 1935, 149, 396-405. (49) Sampson, M. B.; Bleakney, W. Physical Review 1936, 50, 456. (50) Inghram, M. G.; Hess Jr, D. C.; Brown, H. S.; Goldberg, E. Physical Review 1948, 74, 343. (51) Hibbs, R., Mass spectrometric measurements of natural isotopic spectra; 1949. (52) Antkiw, S.; Dibeler, V. H. The Journal of Chemical Physics 1953, 21, 1890-1891. (53) Mason, T. F. D.; Weiss, D. J.; Horstwood, M.; Parrish, R. R.; Russell, S. S.; Mullane, E.; Coles, B. J. Journal of Analytical Atomic Spectrometry 2004, 19, 218-226. (54) Yang, L.; Meija, J. Analytical chemistry 2010, 82, 4188-4193. (55) Machlan, L.; Gramlich, J.; Powell, L.; Lambert, G. J. Res. Natl. Bur. Stand. 1986, 91, 323-331. (56) Brand, W. A.; Coplen, T. B.; Vogl, J.; Rosner, M.; Prohaska, T. Pure and Applied Chemistry 2014, 86, 425-467. (57) Woodhead, J. Journal of Analytical Atomic Spectrometry 2002, 17, 1381-1385. (58) Archer, C.; Vance, D. Journal of Analytical Atomic Spectrometry 2004, 19, 656-665. 23
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
558 559 560 561 562 563 564 565 566 567 568 569 570 571
Page 34 of 40
(59) Vance, D.; Archer, C.; Bermin, J.; Kennaway, G.; Cox, E. J.; Statham, P. J.; Lohan, M. C.; Ellwood, M. J. Geochimica Et Cosmochimica Acta 2006, 70, A666-A666. (60) Hou, Q.; Zhou, L.; Gao, S.; Zhang, T.; Feng, L.; Yang, L. Journal of Analytical Atomic Spectrometry 2016, 31, 280-287. (61) Roehl, R.; Gomez, J.; Woodhouse, L. R. J. Anal. At. Spectrom. 1995, 10, 15-23. (62) Strelow, F. W. E. Talanta 1980, 27, 727-732. (63) Kiriyama, T.; Kuroda, R. Fresenius' Zeitschrift für analytische Chemie 1988, 332, 338-340. (64) Tremillon, B. Mir, Moscow 1967, 33. (65) Strelow, F.; Weinert, C.; Eloff, C. Analytical Chemistry 1972, 44, 2352-2356. (66) Chang, V. T.-C.; Makishima, A.; Belshaw, N. S.; O'Nions, R. K. Journal of Analytical Atomic Spectrometry 2003, 18, 296-301. (67) Horwitz, E.; Bloomquist, C. Journal of Inorganic and Nuclear Chemistry 1975, 37, 425-434. (68) Huang, Q.; Liu, Y. L.; Chen, J. B.; Feng, X. B.; Huang, W. L.; Yuan, S. L.; Cai, H. M.; Fu, X. W. Journal of Analytical Atomic Spectrometry 2015, 30, 957-966.
572 573
24
ACS Paragon Plus Environment
Page 35 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
The list of table and figure
574 Number
Title
Table 1 Table 2 Table 3 Table 4 Table 5 Figure 1
Elution sequence of the two-step separation Nu Plasma II ICP-MS Operating Conditions Neptune Plus ICP-MS Operating Settings Potential species interfering Ga isotope measurement on MC-ICP-MS Results of comparison between Nu and Neptune mass spectrometers Elution curve of Ga separation from matrix on the AG 1×4 resin (A) and the Ln-spec resin (B) The assessment of the influence of Ba (A), Ce (B), Cu (C), Zn (D), Fe (E) and Mo (F) on Ga isotopic measurements Reproducibility of Ga isotope ratio (δ71Ga) for long-term measurements of the standard GBW(E) 08056 on the Nu Plasma II (A, red dots) and the Neptune Plus (B, blue rhombi) using SSB correction method, respectively Standard addition experiment for validation of the whole purification and isotopic analysis protocol
Figure 2 Figure 3
Figure 4 For TOC only 575 576 577 578
for TOC only:
579
25
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 36 of 40
1
Figure 1. Elution curve of Ga separation from matrix on the AG 1×4 resin (A) and the Ln-spec
2
resin (B). Though most of the major and trace elements were removed in the first step, Ga fraction
3
still contained Fe and Mo, requiring a second purification, which was done on the column charged
4
with Ln-spec resin. The detail procedure was described in the text.
5
1
ACS Paragon Plus Environment
Page 37 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
6
Figure 2. The assessment of the influence of Ba (A), Ce (B), Cu (C), Zn (D), Fe (E) and Mo (F)
7
on Ga isotopic measurements. The δ71Ga data was the average value of 5 replicate analyses, and
8
the error bars represented the 2SD uncertainty of all measurements. The effect of Fe and Mo were
9
investigated on both Nu Plasma II (red dots) and Neptune Plus (blue rhombi) machines.
10
2
ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 38 of 40
11
Figure 3. Reproducibility of Ga isotope ratio (δ71Ga) for long-term measurements of the standard
12
GBW(E) 08056 on the Nu Plasma II (A, red dots) and the Neptune Plus (B, blue rhombi) using
13
SSB correction method, respectively. The dashed lines and solid line represented the external
14
long-term standard deviations (2SD) and mean for all tests, respectively. The error bars (2SD)
15
were also given for each measurement and were generally better than 0.05‰.
16 17
3
ACS Paragon Plus Environment
Page 39 of 40
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
18 19
Figure 4. Standard addition experiment for validation of the whole purification and isotopic
20
analysis protocol. The experiment was carried out on six mixture solutions of GBW(E) 08056 Ga
21
and NIST 994 Ga. The δ71Ga values measured here (red points with red error bars, n = 5) for the
22
two pure standards (0.00 ± 0.05‰ and 1.75 ± 0.06‰) were consistent with the results (0.00 ± 0.04‰
23
and 1.74 ± 0.05‰) of long-term measurements. The linear fit attested the accuracy of Ga isotope
24
analysis. The blank dotted lines were the confidence interval of 6 measurements at 95%
25
confidence levels.
26 27 28
4
ACS Paragon Plus Environment
Analytical Chemistry