Subscriber access provided by CORNELL UNIVERSITY LIBRARY
Article
Radiative heat transfer conditions in a rotary kiln test furnace using coal, biomass and co-firing burners Adrian Gunnarsson, Daniel Bäckström, Robert Johansson, Christian Fredriksson, and Klas Andersson Energy Fuels, Just Accepted Manuscript • Publication Date (Web): 12 Jun 2017 Downloaded from http://pubs.acs.org on June 13, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
1
Radiative heat transfer conditions in a rotary kiln test
2
furnace using coal, biomass and co-firing burners
3
Adrian Gunnarssona*, Daniel Bäckströma, Robert Johanssona,
4
Christian Fredrikssonb, Klas Anderssona
5 6
a
Department of Energy and Environment, Chalmers University of Technology, SE-41296
7 8 9
Göteborg, Sweden b
Luossavaara Kiirunavaara Aktiebolag (LKAB), Box 952, SE-971 28, Luleå, Sweden
*Corresponding author. Tel.: +46 31 772 1442 e-mail address:
[email protected] 10
Abstract
11
This work studies the radiative heat transfer in a 580 kWth pilot scale test furnace that resembles a
12
full-scale rotary kiln for iron ore pellet production. The aim is to quantify the radiative heat transfer
13
in coal and co-firing flames, but also to study the possibility to model the radiative heat transfer
14
for such combustion conditions. Three combustion cases of coal and co-firing are studied and an
15
evaluation is made using a detailed radiation model. The test furnace is cylindrical and refractory
16
lined but does not rotate and no iron ore pellet bed material is included. In-flame measurements of
17
temperature, gas composition, particle concentration, radiative intensity and radiative heat flux are
ACS Paragon Plus Environment
1
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 2 of 34
18
conducted for the different fuels and fuel combinations. Overall, the differences in measured
19
radiative intensities and heat fluxes between the three studied fuel cases are minor, which implies
20
that introduction of renewable fuels by co-firing in a full-scale rotary kiln should be feasible with
21
respect to heat transfer conditions. In the model, the furnace is treated as an axisymmetric and
22
infinitely long cylinder and gas properties are calculated with a Statistical Narrow-Band model
23
while particle properties are calculated using Mie theory. The modeling results show reasonable
24
to good predictivity compared to the measured intensity data. This implies a good quality of the
25
collected experimental data, but also indicates the potential use of the model in full-scale rotary
26
kiln calculations in future work.
27
Keywords: radiative heat transfer, co-firing, rotary kiln, radiation measurements, particle radiation,
28
gas radiation
1. Introduction
29 30
Iron ore is a widely used resource with an estimated global production of 3320 million tonnes in
31
2015 according to the 2016 U.S. geological survey on mineral commodity summaries1. The
32
primary user of the iron ore is the steel industry and the large volume produced by the mining
33
companies has to be delivered in a suitable form for easy handling and often long transportations.
34
After crushing and refinement of the mined ore, it is common to deliver the iron ore in a pelletized
35
form. A common process to produce such pellets is the grate kiln process: raw iron ore pellets are
36
fed onto a travelling grate where they are partially dried and oxidized with hot air and flue gases.
37
Then, from the grate, the iron ore pellets enter a rotary kiln where they are further heated, oxidized
38
and sintered. The heated pellets finally leave the rotary kiln as they fall down onto a cooler, see
39
Figure 1. A portion of the air that is used to cool the pellets is introduced as heated secondary air
40
to the rotary kiln. Compared to a more conventional combustion process, the secondary air flow is
ACS Paragon Plus Environment
2
Page 3 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
41
considerably larger to allow oxidation of the iron ore pellets in the kiln, resulting in an oxygen
42
concentration in the stack of about 16%. For a more detailed description of a typical grate-kiln
43
process, see e.g. Jonsson et al.2.
44
Figure 1. Simplified schematic of the grate-kiln process showing the grate, rotary kiln and cooler
45
sections. The burner is located in a center position and is designed to create a jet-type flame. Gas
46
flows are indicated with dashed arrows.
47
During the recent COP 21 conference meeting in Paris 2015, a global target was set to keep the
48
increase of the mean temperature on earth below 2°C. In order to meet this target, the emission of
49
greenhouse gases from the stationary industrial sector need to be drastically reduced. A problem
50
connected to the production of iron ore pellets is the substantial emission of carbon dioxide that it
51
generates since heat is supplied to the process by a flame that is today commonly fueled using
52
fossil coal3. The use of coal in the iron ore pellets industry is mainly due to the availability,
53
composition, cost and high heating values. One way to meet the reduction target in the iron ore
54
pellet industry is to switch to less carbon intensive fuels. However, this may affect the heat transfer
55
conditions in the rotary kiln, thereby impacting the quality of the product.
56
This work focuses on the radiative heat transfer within the rotary kiln, used for iron ore pellets
57
production, and how it might be affected by a fuel switch and by co-firing. A change of fuel may
58
have large effects on the heat transfer within the kiln and it is important to consider possible effects
59
on the product quality. The heat transfer in the freeboard of the rotary kiln is dominated by
ACS Paragon Plus Environment
3
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 4 of 34
60
radiation that makes up for about 90% of the total heat transfer3, primarily due to the high
61
temperature of the flame. Thus, the radiative heat transfer in the rotary kiln has a large impact on
62
the product quality of the iron ore pellets. A number of different elements need to be considered
63
in the rotary kiln: heat is exchanged between the kiln wall and pellet bed as well as the present
64
gases and particles in the furnace that emits, absorbs and scatter radiation. Since a solid fuel is
65
used, the radiation emitted from the flame is anticipated to be dominated by hot particles being
66
present, mainly char but also some soot and ash particles. However, there is today little quantitative
67
knowledge of the heat transfer conditions in rotary kilns using any fuel, mainly due to the rotation
68
of the kiln, a fact that clearly complicates in-flame measurements.
69
The research on radiative heat transfer in combustion systems has been intense since the 1960’s
70
until today with large contributions by combustion scientists such as Hottel & Sarofim4, Siegel &
71
Howell5, Özisik6 and Modest7. From Modest7 we have used theory to build a model to study flame
72
radiation including both gases and particles. Our latest work investigates the radiative heat transfer
73
in coal and gas flames in cylindrical furnaces, using different measurement methodologies and
74
modeling work for different applications including oxy-fuel flames and rotary kilns8–11. Some
75
earlier modeling work of the heat transfer in a rotary kiln can also be found in the literature12–14.
76
These models have focused on the radiative and convective heat transfer of the gases in the
77
freeboard and the surfaces of the kiln, but neglecting the particles present in the freeboard
78
consisting of unburned fuel, soot and ash. However, flame radiation in cylindrical furnaces has
79
been investigated in works related to coal combustion15–17. These studies have investigated the
80
importance of different parameters for pulverized coal-fired furnaces such as scattering
81
efficiencies for different particle types, particle concentrations and size distributions15 as well as
82
the temperature distribution, extinction coefficients and single scattering albedo16. Measurements
ACS Paragon Plus Environment
4
Page 5 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
83
and modeling of the radiative heat flux in a pulverized coal-fired furnace were performed while
84
also evaluating the use of separate temperatures for gases and particles17. In these studies it was
85
found that the coal and char particles were the dominant contributors to the heat flux at the wall
86
and the importance of scattering was stressed15. However, the impact of soot particles on the
87
radiative heat flux to the wall was also stressed as well as the importance of using separate
88
temperatures for gases and particles17. It was further concluded that an accurate knowledge of the
89
temperature and particle concentration distributions were more critical when predicting the
90
radiative heat transfer in a coal fueled furnace than detailed information of gas concentration or
91
index of refraction16.
92
In the present work, measurements and modeling of radiation in a 580 kWth cylindrical test
93
furnace is conducted. The test furnace is built to resemble a full-scale rotary kiln and the burners
94
used are down- scaled models of those employed in the full-scale process. The specific aim of this
95
work is to quantify the radiative heat transfer in coal and co-firing flames, with a specific focus on
96
the influence from the fuel on flame radiation. The main interest is to obtain a better understanding
97
of the possibilities to apply biomass through co-firing in the great-kiln process. In addition, effort
98
is made to examine how well the radiative heat transfer can be modeled in this kind of combustion
99
process by using a detailed axisymmetric discrete transfer model. This model will later be used to
100
get a better understanding of the heat transfer conditions in full scale rotary kilns. In a previous
101
experimental campaign11, significant differences were observed with respect to the emitted flame
102
radiation when different fuels were burned in a test furnace, but the cause of those differences
103
proved difficult to assess due to lack of flame data. This was mainly due to problems in achieving
104
accurate flame temperatures since the suction pyrometer used was clogged with particles and a
105
high suction velocity could therefore not be achieved. Also, particle data was missing in positions
ACS Paragon Plus Environment
5
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 6 of 34
106
close to the burner. However, it was possible to conclude that the heat transfer from the flame was
107
clearly dominated by particle radiation for both coal and co-firing. In this work, a greater focus
108
has been on co-firing flames to better examine differences in temperature conditions and flame
109
structure when compared to a coal flame. Temperature measurements were improved since extra
110
care was taken to reach and sustain a sufficient suction velocity using a new suction pyrometer
111
and ejector system. Particles were sampled in the flame, close to the burner and radiative heat flux
112
was measured. The radiative intensity was also measured and, by using all the gathered data, the
113
modeling was conducted with a higher precision. Also, the test matrix is increased with respect to
114
the number of fuels and fuel combinations tested as well as introducing new measurement
115
techniques such as an FTIR for gas analysis and an infrared camera for temperature estimations.
116
To further improve the quality of the experiments, the test furnace was modified for better process
117
control and a new burner was installed to achieve more stable conditions with respect to biomass
118
feeding. The conducted measurement campaign included one reference coal and three additional
119
coals as well as co-firing of the reference coal and two different biomasses. In this paper, we have
120
selected three different fuels and fuel combinations for evaluation.
2. Experiments
121 122
A measurement campaign was conducted over two weeks during which different fuels and fuel
123
combinations were tested. The experiments were run in a cylindrical, refractory lined test furnace,
124
constructed as a down-scaled version of a full-scale rotary kiln used in a grate-kiln process, see
125
Figure 2. Throughout the campaign different measurements were performed to collect and
126
compare data considering the radiative heat transfer within the furnace between different fuels.
127
Compared to the previous campaign performed in 2013 significant changes regarding the furnace
128
and operating conditions were carried out. The same type of furnace was used in both campaigns,
ACS Paragon Plus Environment
6
Page 7 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
129
but a new facility was built with modifications to better represent the full scale rotary kiln. The
130
inner diameter in the first section (port MH1 to MH12) of the furnace was reduced from 0.8 m to
131
0.65 m, while keeping the second section unchanged. The furnace was tilted to achieve a slope of
132
3° and a cooling system was installed at the bottom of the first section of the furnace to achieve a
133
heat sink resembling the pellet bed. Six additional measurement ports were installed along the axis
134
of the furnace and all ports were numbered, with MH0 corresponding to the position closest to the
135
burner. All ports allow horizontal in-flame measurements using probes. The burner has six
136
registers where two of these were used for primary air, the first (axial air) and fourth (swirled air
137
with an angle of 30°) counted from the rim, and the other four were available for fuel. Secondary
138
air was introduced to the furnace in two large registers, one above and one below the burner, see
139
the works of Bäckström et al.11 and Edland et al.18 for descriptive figures of the burner orifice and
140
secondary air registers. In both campaigns the burner axis was the same as the furnace axis, but
141
the axial position of the burner was changed and the fuel feed was increased from 400 kWth to 580
142
kWth. In contrast to the full scale rotary kiln, the test furnace did not rotate as this would have
143
complicated the construction and operation of the test furnace, but, primarily since this would
144
prevent any in-flame measurements using probes. However, with the burner located at the center
145
of the furnace diameter and by aiming for an axisymmetric flame, the rotation of the kiln itself is
146
thought to have a minor effect on the radiative heat transfer in the furnace.
ACS Paragon Plus Environment
7
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 34
Figure 2. The pilot scale test furnace used in the experimental campaign. Measurement ports are displayed in the figure including the distance [mm] to the burner. 147
The furnace was operated continuously during the campaign and operating conditions were
148
changed during night time so that the system had reached stable conditions in the morning of each
149
day. Seven different set-ups of fuels and fuel combinations were tested in total. This work is
150
focused on three of these cases: a reference coal and co-firing of the reference coal with two
151
different biomasses using a composition of 70% reference coal and 30% biomass. The percentage
152
numbers are based on the lower heating values. The reference coal (RC) is the coal normally used
153
on a daily basis in the full scale rotary kiln. It is a carbon rich coal which was milled to a volume
154
weighted mean diameter of 54 µm, similar to what is used in the full scale process. The two
155
biomasses are here referred to as biomass A (BA) and biomass B (BB). Biomass A was based on
156
wood treated with steam explosion while biomass B was untreated but grinded wood and delivered
157
in a pelletized form. The pellets were grinded before introduced to the burner with volume
158
weighted mean diameters of 210 µm and 443 µm for biomass A and B, respectively. A proximate
159
analysis of each fuel is presented in Table 1. Coal and biomass were fed in two different annular
160
registers in the burner, namely registers two and three from the rim; the biomass was fed in the
161
outer register. The total flow of primary air and fuel transport air to the burner was about 200
ACS Paragon Plus Environment
8
Page 9 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
162
Nm3/h at a temperature of about 20°C. The secondary air flow was about 2300 Nm3/h and was
163
preheated to about 1050°C. For more precise air flows see Edland et al.18.
164
Table 1. Proximate fuel analysis and lower heating values for the fuels studied
165
RC
BA
BB
166
Moisture
(as received) 0.9%
4.4%
7.8%
167
Volatiles
(dry basis)
21.6%
76.2%
83.9%
168
Fixed carbon
(dry basis)
65.1%
22.7%
15.7%
169
Ash
(dry basis)
13.3%
1.1%
0.37%
Lower heating value
(as received) 29.4 MJ/kg
19.3 MJ/kg
17.5 MJ/kg
170 171
For the three cases the thermal input was kept constant at 580 kWth. The mass flow of fuel and
172
the carbon dioxide emissions are shown in Table 2 for the three cases, calculated on the
173
composition as the fuels were received. It should be noted that, although the total amount of
174
emitted carbon dioxide was slightly increased from the furnace in the co-firing cases, the portion
175
originating from fossil coal was reduced by 30%.
176
Table 2. Mass flow of fuel and carbon dioxide emissions for the different cases Case
Fuel [g/s]
CO2 [mole/kg]
CO2 [g/MJ]
RC
19.7
62.8
93.9
RC + BA
22.8
54.7
94.6
RC + BB
23.7
52.9
95.2
177
3. Measurements
178 179
During the experimental campaign gas and wall temperatures, gas composition, particle
180
concentration, particle size distribution, radiative intensity and radiative heat flux were measured.
ACS Paragon Plus Environment
9
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 10 of 34
181
Most of these in-flame measurements were performed using probes to traverse the flame. All
182
probes described below were constructed in either stainless steel or titan and were water cooled.
183
For gas temperature measurements a triple shielded suction pyrometer of IFRF type with a Type
184
B thermocouple was used. The probe was traversed along the furnace diameter and the temperature
185
was measured at 7 positions distributed along the furnace diameter for ports MH0, MH1, MH3
186
and MH7, see Figure 2. The shields at the tip of the probe were constructed in ceramics (not cooled)
187
with a length of about 15 cm. To perform temperature measurements by means of using a suction
188
pyrometer is challenging in environments with high particle concentrations and high temperatures
189
since this might cause problems due to melting of ashes with subsequent blocking of the probe.
190
Severe such problems were encountered at some occasions during the campaign and the ceramic
191
tip was therefore regularly checked to see if it had been clogged and, if so, it was exchanged. The
192
opening in the ceramic tip was directed perpendicular to the probe and to decrease the particle load
193
in the suction line, it was directed towards the stack. Keeping it directed towards the burner caused
194
instant clogging and thus destruction of the ceramics. Further, a too low suction velocity or large
195
local temperature gradients may result in under- as well as over-predictions of the temperatures
196
due to radiative heat exchange with the surroundings and gas extraction from a too large
197
measurement volume.
198
For measurements of the gas composition, a gas extraction probe connected to a FTIR gas
199
analyzer was traversed through the flame in the same manner as the suction pyrometer and the
200
measurements were performed in the same positions as the temperature measurements.
201
Particle concentration and size distribution were measured by extracting samples in the flame.
202
This was done by using a probe connected to a low pressure impactor with thirteen size steps
203
ranging from 30 nm to 10 µm. Particles of a size larger than 10 µm were captured in a cyclone
ACS Paragon Plus Environment
10
Page 11 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
204
placed prior to the impactor. The opening of the particle sampling probe was directed towards the
205
burner, perpendicular to the port axis. The sample gas was diluted with nitrogen in the tip of the
206
probe, with a flow of about 10 times the sampling flow. The overall dilution rate was then
207
estimated by comparing the oxygen concentration in the diluted sampling gas with the oxygen
208
concentration in the measurement position. These particle measurements are practically
209
challenging, and with a limited number of low pressure impactor set-ups also time consuming.
210
This made it necessary to restrict the particle sampling to the center position in ports MH3 and
211
MH7, with one repetition at each position and fuel. To better resolve the particle size distribution,
212
particles collected in the cyclone were further analyzed after the campaign with laser diffraction.
213
In the analysis the particle diameter was estimated for 100 size steps between 0.010 and 10000
214
µm. During the particle extraction in the co-firing cases, condensation of tars caused blocking of
215
the probe suction line and data for these cases are therefore lacking. Due to these problems, the
216
particle data had to be discarded for the co-firing cases and only measurements on the reference
217
coal could be used.
218
Radiative intensity was measured using a narrow angle radiometer, see Figure 3. This instrument
219
measures in the line-of-sight of the probe, extinguishing incoming light that is not in the axis of
220
the probe, and has been used in several of our previous studies10,11,19,20. Rays of light reaches a
221
thermopile in the detector house of the probe (a). The detector was calibrated before and after the
222
measurement campaign using a black body oven. The direction of the probe was aimed towards a
223
quartz glass on the opposite wall of the furnace acting as a cold background to remove background
224
radiation from the hot wall. This allows us to isolate the flame radiation. However, due to
225
scattering, some radiation emitted from the wall will still reach the detector. The radiative intensity
226
was measured in 15 positions distributed along the furnace diameter for ports MH1, MH3 and
ACS Paragon Plus Environment
11
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 34
227
MH7. The radiative heat flux was measured at the inner wall of the furnace, at the port entrance,
228
using an ellipsoidal radiometer with a viewing field of 2π sr placed in the tip of a probe for ports
229
MH0, MH1, MH3 and MH7.
Figure 3. Schematic of the narrow angle radiometer which was used to measure the total radiative intensity. The probe includes the following components: a thermopile, b focusing lens, c shutter, d PT-100, e water cooled sensor housing, f collimating tube and g water cooled probe. 230
The inner wall temperatures were studied using an infrared camera. The camera used was a FLIR
231
A655SC with the possibility to measure temperatures up to 2000°C at a sampling frequency of
232
200 Hz and for 640x120 pixels. The camera was placed outside the ports, looking into the furnace,
233
and videos were recorded for ports MH0-MH10. By analyzing the recorded videos in the software
234
FLIR Research IR Max, the wall temperatures could be estimated using temperature field
235
resolution. Boundaries for such temperature fields were set from observing the presence and
236
absence of particles; streaks of particles could be observed when passing the measurement ports.
237
The average temperature within this field was then estimated using a set emissivity for the wall of
238
0.80 and a set reflected temperature to match the wall temperature. Flame temperatures could
239
possibly also be estimated from the infrared camera but are not considered in this work.
ACS Paragon Plus Environment
12
Page 13 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
4. Modeling
240 241
The radiation model used in this work is an axisymmetric discrete transfer model for cylindrical,
242
infinitely long furnaces considering the contribution from both gases and particles. Gas properties
243
are modeled on a spectral basis using the Malkmus Statistical Narrow-Band model for gases21,
244
with parameters from the work of Rivière and Soufiani22, and particle properties using Mie
245
theory23. Complex indices of refraction are required using Mie theory, and data presented by Foster
246
and Howarth24 was used in this work, and a representative particle diameter was calculated from
247
the size distribution of the fuel. Scattering of radiation due to the presence of particles was
248
considered to be isotropic, but this assumption is also tested in a sensitivity analysis. The
249
assumption of the infinitely long furnace leads to neglected gradients along the axis of the furnace,
250
parameters such as temperature or gas concentration. However, considering the radial and axial
251
dimensions of the furnace, axial gradients are estimated to have a limited effect on a radial cross
252
section of the furnace. Required inputs to the model are mainly radial profiles of temperature, gas
253
composition and projected surface area of particles. The output from the model of main interest in
254
this work was the radiative intensity from the gases and particles separately, as well as a total
255
intensity, which corresponds to the intensity measured with the narrow angle radiometer. The
256
model is described in more detail in the work of Johansson et al.25.
257
Measurements from the suction pyrometer were used for the temperature profile. The
258
surrounding wall temperature was estimated based on data from the infrared camera, but a cold
259
background was used at the position directly opposite of the ports. Gas profiles were obtained from
260
the FTIR data for the gases considered in the model i.e. water vapor and carbon dioxide. Particle
261
measurements were in this work performed in the center position of the flame where the largest
262
portion of the sampled particles was unburnt fuel. Ash particles were also present, but to a much
263
lower degree and are thus not considered in the model. Any particles measured with the low-
ACS Paragon Plus Environment
13
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 14 of 34
264
pressure impactor with a size smaller than 0.2 µm were assumed to be soot and emit and scatter
265
radiation according to Rayleigh theory10. All particles larger than 0.2 µm were considered to be
266
unburnt fuel particles and from here, the term “particles” refers to these unburnt fuel particles. The
267
surface area of the particles within the furnace is required to calculate the absorption coefficient
268
of the particles and therefore a projected particle area per surrounding furnace volume was
269
calculated23, based on the particle size distributions for the different cases and ports. For these
270
calculations some assumptions had to be made. Since no particles were extracted from port MH1,
271
and due to the short distance from the burner, the fuel was assumed to be oxidized to some degree.
272
For most of the results shown in this paper it was set to be 20% based on a good fit to the measured
273
radiative intensity. That is, the total projected surface area of the particles at port MH1 accounted
274
for 80% of the total projected surface area of the fuel inserted through the burner, as calculated
275
from the fuel analysis. To test this assumption, the degree of oxidation was varied in a sensitivity
276
analysis and the impact on the modeled radiative intensity was studied. Based on the extractive
277
particle measurements in ports MH3 and MH7 the total projected surface area of the particles was
278
estimated. Since particle data in the co-firing cases was not available, the projected surface area
279
was assumed similar for all three cases. This was based on the fact that the co-firing cases still
280
contained 70% reference coal. Since the coal particles are smaller, the largest portion of the total
281
projected surface area will arise from these particles. It was assumed that the total projected surface
282
area was decreased at the same rate for all three cases along the axis of the furnace. That is, a total
283
projected surface area was calculated separately for each fuel at port MH1, based on fuel analyses,
284
but the relative decrease between downstream ports is assumed to be the same for the three cases
285
in this study. This assumption leads to higher uncertainties in the co-firing cases compared to the
286
reference coal case.
ACS Paragon Plus Environment
14
Page 15 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
287
As the radiative emission of the particles is strongly dependent on the flame temperature it is
288
important to consider how the particles may be distributed over a cross section of the furnace. The
289
fuel stream was introduced at the burner orifice in the center of the furnace and particles are then
290
spread over the furnace diameter. How they are spread is indicated by the radiative intensity
291
measurements. In port MH1, relatively close to the burner, the particle stream was assumed to be
292
widened in the form of a cone growing from the burner, with a constant particle concentration in
293
the whole cross section of the particle cone. This distribution may be described using a step
294
function of the projected surface area. That is, the projected surface area was set to a constant value
295
for a certain radial distance between the furnace centerline and the furnace wall, after which it is
296
set to zero; this distance is referred to as the flame radius. Downstream, in port MH3, particles
297
were assumed to be spread over a larger radius but also with concentration gradients over the cross
298
section of the furnace. This distribution was assumed to follow a cosine profile with a peak value
299
at the center of the furnace, and, set to zero at Rf, i.e. the radius from the center within which
300
particles are present. The projected particle surface area per furnace volume at a distance r from
301
the furnace center is, in port MH3, given by: 0 ≤ 𝑟 ≤ 𝑅𝑓 𝑅𝑓 < 𝑟 ≤ 𝑅
𝐴𝑝 (𝑟) = 𝑓𝑝 ∙
𝑅2 𝜋∙𝑟 2 ∙ 1.681 (cos ( 𝑅 ) + 1) 𝑅𝑓 𝑓
(1)
𝐴𝑝 (𝑟) = 0
302
where fp is the projected surface area per reactor volume when the particles are distributed equally
303
over a disk with radius R, as in port MH1. The total projected surface area from the particles is
304
kept constant in the cross section of the furnace using this profile when assuming a cosine profile
305
instead of a constant value. The peak value assumption of the projected surface area, located at the
306
center position of the furnace, was assessed in a sensitivity analysis. The peak value was relocated
ACS Paragon Plus Environment
15
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 16 of 34
307
to appear at some distance from the center axis, to study the effect on the modeled radiative
308
intensity.
309
Since the projected surface area of the particles was calculated from the size distribution of the
310
fuel at port MH1, the total projected particle surface area was fixed and a smaller flame radius
311
resulted in a higher peak value, see Figure 4 a. At ports downstream of MH1 the projected surface
312
area was instead calculated from the extractive particle measurements using the collected masses
313
in the low pressure impactor and cyclone. Since particles were collected at the center line of the
314
furnace, the peak value of the projected surface area was a fixed value and a particle distribution
315
was calculated for a smaller flame radius resulted in a smaller total projected particle surface area,
316
as in Figure 4 b for port MH3. In port MH7 particles were assumed to have developed a more even
317
distribution, but throughout the whole furnace diameter and a plug flow of particles was assumed
318
in the model. The plug flow concentration of particles in port MH7 can be seen in Figure 4 c.
319
Figure 4. Distributions of the projected surface area per volume within the furnace for the three
320
ports. The flame radius (Rf) is varied for different appropriate values considering the studied cases.
321
a) Port MH1, assuming a fixed total projected surface area, b) and c) using a fixed peak value as
322
measured with a low-pressure impactor and cyclone but different types of distribution profiles for
323
ports MH3 and MH7 respectively.
ACS Paragon Plus Environment
16
Page 17 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
5. Results and Discussion
324 325
Interpolated temperature maps for the axial cross section at the center of the furnace, seen from
326
above, are shown in Figure 5 for the three studied cases. Temperature measurements were
327
performed at four axial positions, i.e. ports MH0, MH1, MH3 and MH7, indicated with black
328
dashed lines in the figure with the burner to the left and port MH7 to the right. To achieve the
329
temperature maps, the temperature was first extrapolated to reach all the way to the opposite wall
330
of the port entrance in the furnace, i.e. at 0.65 on the diameter axis, using the two temperature
331
measurements performed closest to the wall. Between the measurement ports, temperatures were
332
calculated at axial positions corresponding to all ports between MH1 and MH7, i.e. with an equal
333
axial distances of 250 mm. These values were linearly interpolated using measured temperatures
334
at the same radial positions for axially upstream and downstream ports of the evaluated position.
335
The gas temperature of the secondary air entering at the axial position of the burner was set to
336
1045°C, since the air was preheated to that temperature. At the center position, 0 m from the
337
burner, cold fuel enters the furnace with primary air not being preheated, and the temperature at
338
this position was set to 20°C. It can be seen that the flames were tilted slightly towards the furnace
339
wall located opposite of the port entrances, i.e. the flames were not perfectly centered in the
340
furnace. It should be noted that some temperature measurements in the center, and/or next to the
341
center position, in port MH0 and MH1 appears to be unexpectedly low. This was due to high
342
concentrations of particles clogging the suction pyrometer. However, the measured radial
343
temperature profiles were used as input to the radiation model assuming the flame to be
344
axisymmetric using an average value of temperatures, measured at equal distances on the right and
345
left side of the furnace center, according to:
ACS Paragon Plus Environment
17
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 18 of 34
1
4 4 4 𝑇𝑅𝑖𝑔ℎ𝑡 + 𝑇𝐿𝑒𝑓𝑡 ̅ 𝑇=( ) 2
(2)
346
The measured gas compositions were also not radially symmetric, and gas composition profiles
347
were introduced to the model using a simple averaging for positions on equal distances from the
348
center.
349
Figure 5. Linearly interpolated temperature maps [°C] for the three cases studied using
350
measurements from the suction pyrometer. Each contour line corresponds to a temperature step of
ACS Paragon Plus Environment
18
Page 19 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
351
50°C. Top - reference coal, middle - co-firing with biomass A and bottom - co-firing with biomass
352
B. Black dashed lines indicates port axis where measurements where performed with port MH7
353
located at the right end of the figures.
354
Throughout the campaign the infrared camera was used to estimate the inner wall temperature
355
of the furnace, but also to study the flame and presence of particles along the axis of the furnace.
356
For the three cases studied in this work a narrow and dense stream of particles was observed close
357
to the burner at MH0 where the particles had yet not ignited. The particle stream was broadened
358
downstream of port MH0, but still consisted of “cold” particles, which had not yet fully ignited in
359
MH1. However, it should be noted that single particles could not be studied, while fields of
360
particles could be observed. Downstream of MH1 the particle concentration appeared to be
361
reduced for each port farther from the burner, see Figure 6 a – d. a)
b)
c)
d)
362
Figure 6. Representative snapshots for the reference coal case showing the interior of the furnace
363
with hot gases and particles from recorded videos using the infrared camera. The suspension flow
364
moves from the left to the right in the figures. Particles can be observed as more "dense fields"
365
passing the ports. a) Port MH0 with a high density of particles, b) port MH1 with considerable
ACS Paragon Plus Environment
19
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 20 of 34
366
amounts of particles, c) port MH3 and d) port MH7 with fewer particles. The ports on the opposite
367
side of the furnace acting as cold backgrounds can be seen as the dark circles located close to the
368
center of figures b)-d).
369
After analyzing the extracted particles, the total projected surface area from the particles were
370
estimated and could be compared to the total projected surface area as calculated from the fuel
371
analyses. This was done under the assumptions that particles are spread according to a cosine
372
profile in port MH3 but equally spread along the furnace diameter in port MH7, and all three fuel
373
cases to be combusted at the same rate. The total projected surface area was estimated to be reduced
374
to about 50% and 45% of the total projected surface area introduced to the burner for ports MH3
375
and MH7 respectively. This reduced area is due to fewer particles being present for each
376
downstream port. It should be noted that the particle amount close to the wall at port MH7 is
377
probably overestimated due to the plug flow assumption, but this has a minor impact on the
378
radiation analysis.
379
Particles collected in the cyclone were studied for the different cases in a microscope and it could
380
be observed that the collected biomass particles were considerably larger than the coal particles,
381
and, that the collected biomass particles had not yet ignited, Figure 7. Figure 7 a and b shows
382
particles extracted during co-firing with biomass A in ports MH3 and MH7 respectively; the red-
383
brown particles being biomass A. Particles collected from the co-firing case with biomass B can
384
be seen in Figure 7 c and d in ports MH3 and MH7 respectively. Biomass B particles were much
385
larger than the coal particles. Although it could be observed that the particles were not spherical,
386
especially the biomass particles, all particles were still assumed to be spherical for all three cases
387
and ports studied in the model. This assumption is for example justified by the work of Gronarz et
388
al.26, which shows that the particle shape has a negligible influence on the scattering and absorption
ACS Paragon Plus Environment
20
Page 21 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
389
coefficients. Further, the large biomass particles contained a lot of mass but a relatively small
390
emitting surface area. a)
b)
c)
d)
391
Figure 7. Particles extracted from the flame and collected in the cyclone studied in a light
392
microscope. a) & b) co-firing with biomass A at ports MH3 & MH7 respectively, c) & d) co-firing
393
with biomass B at ports MH3 and MH7 respectively.
394
Figure 8 shows the measured and modeled radiative intensity along the furnace diameter for the
395
three cases in ports MH1, MH3 and MH7. The narrow angle radiometer was traversed along the
396
diameter with incremental steps of 5 cm with an extra position at the center line. Measurements
397
are indicated with triangles in the figure. The inner wall of the furnace, at which the probe entered
398
the furnace, is positioned at the 0 m position. At the port entrance, high intensities were measured
399
as the line-of-sight of the detector was the entire furnace diameter. Measured intensities appearing
400
to show on a flat profile, close to the port entrances for ports MH1 and MH3, is mainly an effect
401
of the absence of particles close to the furnace wall. As the probe was traversed closer to the center
402
the radiative intensity decreased as the amount of particles in the line-of-sight between the probe
ACS Paragon Plus Environment
21
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 22 of 34
403
and the cold background decreased. At the opposite wall, located at the distance 0.65 m, the
404
intensity was close to zero due to the quartz window that was used as a cold background. The
405
measured intensities increased moving from port MH1 to MH3 and decreased again moving to
406
port MH7. This was an effect of cold fuel particles that had yet not been ignited at port MH1 while
407
particles had been ignited to a larger extent at port MH3, which resulted in higher flame
408
temperatures. In port MH7 the particle concentration was lower due to the progression of the
409
combustion and the contribution from particles to the radiative emission decreased. The gradient
410
of the radiative intensity plots decrease along the furnace axis as the particles become more evenly
411
distributed, i.e. when moving from port MH1 to MH3 and MH7. The size of the flame radius is
412
indicated when observing the distance between the furnace center and to where the measurement
413
profile flattens out. Based on this, the flame radius (where particles exist) was estimated to 0.15 m
414
in MH1 and 0.325 in MH3. In port MH7 a plug flow distribution of particles was assumed.
415
The narrow angle radiometer was calibrated using a black body oven before and after the
416
campaign and an averaged deviation of the measured radiative intensity from the two calibrations
417
was found to be 1.8 kW/m2sr in the signal interval 0.2-75 kW/m2sr. In the modeling of the radiative
418
heat transfer an extra distance of 0.285 m was added representing the measurement port on the
419
opposite side of the furnace. No particles were assumed to be present in the measurement ports
420
and the concentrations of water vapor and carbon dioxide were low, which results in an
421
insignificant contribution to the radiative intensity in the measurement ports. When comparing the
422
modeled contributions from gases and particles to the total radiative intensity, it becomes clear
423
that the particle radiation (dashed line) dominates and the portion arising from the gases (dash-
424
dotted line) was small for all cases and ports. In total, the agreement between measured and
ACS Paragon Plus Environment
22
Page 23 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
425
modeled radiative intensity was satisfactory for the different ports and cases. This implies that the
426
measurements of temperature and particle concentration were accurate in this campaign.
427
The radiative intensities for the case with the reference coal are shown in Figure 8 a – c. Overall,
428
the modeled data agrees well with the measurements, in particular with respect to ports MH3 and
429
MH7. Figure 8 d – f shows satisfactory agreement between modeled and measured intensities, for
430
the co-firing with biomass A, in ports MH1 and MH7, while the temperature or particle
431
concentration for port MH3 appeared to be underestimated. Comparing the reference coal and the
432
biomass A co-firing cases port by port, the radiative intensities were in the same order of
433
magnitude for all three ports, which indicates that the combustion process and the resulting heat
434
transfer conditions are similar for these fuel mixes. The modeled radiative intensity, with the
435
reference coal co-fired with biomass B are shown in Figure 8 g – i. For ports MH1 and MH7, the
436
model over-predicts the radiative intensity. The likely explanation is the projected surface area of
437
the particles being different than assumed. Smaller particles, with a high projected surface area per
438
mass, are likely combusted in a shorter time, while the large particles of biomass B are still
439
unburned, resulting in a lower total projected surface area. From a comparison of the reference
440
coal and the co-firing case with biomass B, the radiative intensities are lower for the co-firing case
441
in all three ports. However, the axial trends are similar, which indicates that the combustion
442
processes is similar to the reference coal case.
ACS Paragon Plus Environment
23
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 24 of 34
443
Figure 8. Modeled total radiative intensity as well as the contributions from gas and particles
444
represented with lines. Measured intensities are represented with triangles. a) – c) the reference
445
coal, d) – f) co-firing with biomass A and g) – i) co-firing with biomass B for ports MH1, MH3
446
and MH7 respectively.
447
During the campaign the radiative heat flux to the inner wall of the furnace was measured for
448
ports MH0, MH1, MH3 and MH7 for the three studied cases, Figure 9. As the heating of the iron
ACS Paragon Plus Environment
24
Page 25 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
449
ore pellets is largely influencing the product quality, the radiative heat flux directed to the wall of
450
the furnace is an important parameter. Figure 9 shows only small differences in the measured
451
radiative heat flux between the different fuel combinations at the different ports. In addition, it
452
should be noted that a large portion of the measured heat flux stems from the hot inner walls of
453
the furnace and the increased measured values are in line with the increased wall temperature as
454
estimated from the infrared camera. Although it was shown in Figure 8 that the radiative intensity
455
from the flame is due to particles, the dominating portion of the flux is emitted by the hot
456
surrounding wall.
457
Figure 9. Measured radiative heat flux to the inner wall of the furnace for the three studied cases
458
at ports MH0, MH1, MH3 and MH7.
459
As discussed in the modeling section, the projected surface area from the particles was not
460
known in port MH1. This parameter was tested in the model for the reference coal case by varying
461
the fuel portion that is not combusted at this location, see Figure 10. It appears as the particle load
462
has to be reduced to 60% of what was introduced to the burner to achieve a good fit between
463
modeled and measured radiative intensities. However, this is not a likely explanation as the
464
distance between the burner and port MH1 is rather short. A more probable explanation is that for
465
the particles in the center not yet have ignited and therefore still have a low temperature, compared
466
to the surrounding gas.
ACS Paragon Plus Environment
25
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 26 of 34
467
Figure 10. Modeled total radiative intensity for the reference coal case in port MH1. The portion
468
of the fuel introduced to the burner not being combusted at the port is varied. Measurement data
469
is represented by triangles.
470
The axisymmetric assumption (see modeling section) was assessed in the modeling, see Figure
471
11. When comparing the modeled total radiative intensity profiles, it can be seen that the largest
472
deviation was found for the co-firing case with biomass A in port MH1. The modeled total
473
radiative intensities along the furnace diameter using the different temperature profiles for the co-
474
firing case with biomass A for the three ports are shown in Figure 11 a-c together with the
475
measured radiative intensity. The larger differences observed at port MH1 is mainly due to
476
problems with clogging of the suction pyrometer while measuring the temperature in positions
477
close to the center position of the port, as discussed previously. These problems resulted in
478
temperature differences of more than 300 K for the same radial distance but at different sides of
479
the furnace centerline. The differences were found to be smaller for the downstream ports MH3
480
and MH7. From these findings it is clear that the assumption of an axisymmetric flame does not
481
introduce significant errors in the modeling.
ACS Paragon Plus Environment
26
Page 27 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
482
Figure 11. Measured and modeled total radiative intensity along the furnace diameter for the co-
483
firing case with biomass A using three different temperature profiles in ports, a) MH1, b) MH3
484
and c) MH7.
485
The location of the peak value for the particle concentration was also assessed, see Figure 12.
486
Based on the particle extraction, the maximum value was relocated with 0.075 m from the center.
487
The new maximum value was set to be 120% of the value at the center position. It should be noted
488
here, that increasing the peak value increases the total projected surface area and hence increases
489
the modeled radiative intensity that originates from the particles. For a better comparison, it was
490
decided to change the flame radius to keep the total projected surface area in the cross section of
491
the furnace. This was tested for the reference coal case at port MH3, Figure 12. As shown, the
492
modeled radiative intensity is slightly increased as the projected surface area at the hot
493
temperatures close to the center line is increased, but the effect is small.
ACS Paragon Plus Environment
27
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 28 of 34
494
Figure 12. Variation of the peak value position of the projected particle surface area along the
495
furnace diameter. The peak value is located 0.075 m from the center with a) the distribution profiles
496
and b) comparison of modeled total radiative intensity for the reference coal case at port MH3.
497
Finally the isotropic scattering assumption was also assessed and results are present in Figure
498
13. In the sensitivity analysis the portion of the incoming radiation that was scattered forward was
499
varied to be between 40 and 80% of the total incoming radiation respectively, while the remaining
500
part was still considered to be isotropic scattering. Large deviations appear as the scattering
501
assumption was changed from being fully isotropic. The reason is that radiation that originates
502
from the hot wall is no longer scattered into the modeled diameter with the cold background. The
503
large differences observed in this parameter study motivates and shows on the importance to
504
further examine the particle scattering within suspension-fired systems as well as other solid fuel
505
combustion systems in future works.
ACS Paragon Plus Environment
28
Page 29 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
506
Figure 13. Variation of the portion of incoming radiation being forward scattered with 40 or 80%
507
compared to fully isotropic scattering for the reference coal case at port MH3.
6. Conclusions
508 509
The present work aims to examine the radiative heat transfer conditions in a 580 kWth rotary kiln
510
test furnace when burning coal and biomass-coal mixtures in suspension. The test furnace is
511
cylindrical and is constructed as a down-scaled version of a rotary kiln used for iron ore pellets
512
production. The possibility to exchange a portion of the fossil coal to renewable biomass is
513
evaluated as a possible measure to reduce greenhouse gas emissions without affecting the quality
514
of the pellet product in the full-scale process. This work presents measurements for three fuel cases
515
performed during one measurement campaign. These cases include a reference coal and two co-
516
firing cases using 70% (based on the lower heating value) of the same reference coal and 30% of
517
biomass (A: wood treated with steam explosion, and B: untreated but grinded and pelletized
518
wood).
519
Collected data of temperature, gas composition and particle concentration were used in a detailed
520
radiation model. The radiation model accounts for gases using a statistical narrow band model and
521
particles using Rayleigh and Mie-theory for soot and fuel particles respectively. The radiative
522
intensity was measured using a narrow angle radiometer and a good agreement between measured
523
and modeled radiative intensities was achieved. This implies that accurate measurements were
ACS Paragon Plus Environment
29
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 30 of 34
524
performed during the campaign, and that the model is a promising tool to be developed and used
525
to obtain a better understanding of full-scale rotary kiln processes. Based on the measured radiative
526
intensities, there are only small differences between the reference case and the co-firing case with
527
biomass A. The measured values for the co-firing case with biomass B are lower but the overall
528
combustion and heat transfer conditions are similar for all three fuel mixtures.
529
The incident radiative heat flux to the wall of the furnace has a large impact on the heating of
530
the pellets and the product quality and was measured using an ellipsoidal radiometer. The
531
differences between the three cases were minor for the studied ports, which indicates that changing
532
the fuel from the reference coal to co-firing with either biomass A or B is a possible option in the
533
full-scale process.
534
Sensitivity analyses were performed for some parameters of interest to test the impact on the
535
modeled total radiative intensity. The particle distribution was not known in the furnace, but by
536
varying the radial position of the particle concentration peak value it was shown that only minor
537
effects on the modeled radiative intensity was obtained. The scattering of radiation was also
538
assessed by varying the portion of the radiation being scattered in the forward direction, that is
539
instead of being isotropically scattered. Anisotropic scattering was shown to have a significant
540
impact on the modeled intensities and this motivates further studies on this important parameter in
541
particular for systems with high wall temperatures.
542
To conclude, from the results presented here it seems promising to use biomass for co-firing
543
purposes in rotary kilns; the heat transfer is not significantly affected while the carbon dioxide
544
emissions can be substantially reduced.
ACS Paragon Plus Environment
30
Page 31 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
545
Energy & Fuels
7. Acknowledgement
546
LKAB and the Swedish Energy Agency is acknowledged for the financial support of this work.
547
LKAB is also acknowledged for providing the experimental data from the ECF test facility and
548
for the inspiring experimental collaboration.
ACS Paragon Plus Environment
31
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 32 of 34
549 550
References (1)
U.S. Geological Survey. MINERAL COMMODITY SUMMARIES 2016; 2016.
551
(2)
Jonsson, C. Y. C.; Stjernberg, J.; Wiinikka, H.; Lindblom, B.; Boström, D.; Öhman, M.
552
Deposit formation in a grate-kiln plant for iron-ore pellet production. Part 1:
553
Characterization of process gas particles. Energy and Fuels 2013, 27 (10), 6159–6170.
554
(3)
555 556
2008. (4)
557 558
Hottel, H. C.; Sarofim, A. F. Radiative Transfer; McGraw-Hill, Inc.: United States of America, 1967.
(5)
559 560
Boateng, A. A. Rotary Kilns Transport Phenomena and Transport Processes; Burlington,
Siegel, R.; Howell, J. R. Thermal Radiation Heat Transfer; Clark, B. J., Damstra, D., Eds.; McGraw-Hill, Inc.: United States of America, 1972.
(6)
561
Özisik, M. N. Radiative Transfer and Interactions with Conduction and Convection; John Wiley & Sons, Inc.: United States of America, 1973.
562
(7)
Modest, M. F. Radiative Heat Transfer; Elsevier: United States of America, 2013.
563
(8)
Bäckström, D.; Johansson, R.; Andersson, K.; Johnsson, F.; Clausen, S.; Fateev, A. Gas
564
temperature and radiative heat transfer in oxy-fuel flames; Paper presented at 37th
565
International Technical Conference on Clean Coal & Fuel Systems. The Clearwater Clean
566
Coal Conference, Clearwater, FL, United States. 2012.
567
(9)
Bäckström, D.; Johansson, R.; Andersson, K.; Johnsson, F.; Clausen, S.; Fateev, A.
568
Measurement and modeling of particle radiation in coal flames. Energy and Fuels 2014, 28
569
(3), 2199–2210.
ACS Paragon Plus Environment
32
Page 33 of 34
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
570
Energy & Fuels
(10)
Bäckström, D.; Gall, D.; Pushp, M.; Johansson, R.; Andersson, K.; Pettersson, J. B. C.
571
Particle composition and size distribution in coal flames - The influence on radiative heat
572
transfer. Exp. Therm. Fluid Sci. 2015, 64, 70–80.
573
(11)
Bäckström, D.; Johansson, R.; Andersson, K.; Wiinikka, H.; Fredriksson, C. On the use of
574
alternative fuels in rotary kiln burners - An experimental and modelling study of the effect
575
on the radiative heat transfer conditions. Fuel Process. Technol. 2015, 138, 210–220.
576
(12)
577 578
Trans. B 1981, 12 (1), 55–70. (13)
579 580
(14)
(15)
(16)
Mengüc, M. P.; Viskanta, R. A sensitivity analysis for radiative heat transfer in a pulverized coal-fired furnace. Combust. Sci. Technol. 1987, 51, 51–74.
(17)
587 588
Marakis, J. G.; Papapavlou, C.; Kakaras, E. A parametric study of radiative heat transfer in pulverised coal furnaces. Int. J. Heat Mass Transf. 2000, 43 (16), 2961–2971.
585 586
Boateng, A. A.; Barr, P. V. A thermal model of the rotary kiln including heat transfer whitin the bed. Int. J. Heat Mass Transf. 1996, 39 (10), 2131–2147.
583 584
Barr, P. V.; Brimacombe, J. K.; Watkinson, A. P. A heat-transfer model for the rotary kiln: Part II. Development of the cross-section model. Metall. Trans. B 1989, 20 (3), 403–419.
581 582
Gorog, J. P.; Brimacombe, J. K.; Adams, T. N. Radiative heat transfer in rotary kilns. Metall.
Butler, B. W.; Denison, M. K.; Webb, B. W. Radiation heat transfer in a laboratory-scale pulverized coal-fired reactor. Exp. Therm. Fluid Sci. 1994, 9, 69–79.
(18)
Edland, R.; Normann, F.; Fredriksson, C.; Andersson, K. Implications of fuel choice and
589
burner settings for combustion efficiency and NOx formation in PF-fired iron ore rotary
590
kilns. Energy & Fuels 2017, 31 (3), 3253-3261
ACS Paragon Plus Environment
33
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
591
(19)
592 593
Page 34 of 34
Andersson, K.; Johansson, R.; Hjärtstam, S.; Johnsson, F.; Leckner, B. Radiation intensity of lignite-fired oxy-fuel flames. Exp. Therm. Fluid Sci. 2008, 33 (1), 67–76.
(20)
Andersson, K.; Johansson, R.; Johnsson, F.; Leckner, B. Radiation intensity of propane-
594
fired oxy-fuel flames: Implications for soot formation. Energy & Fuels 2008, 22 (3), 1535–
595
1541.
596
(21)
597 598
distribution function. J. Opt. Soc. Am. 1967, 57 (3), 323–329. (22)
599 600
(23)
(24)
Foster, P. J.; Howarth, C. R. Optical constants of carbons and coals in the infrared. Carbon N. Y. 1968, 6 (5), 719–729.
(25)
605 606
Modest, M. F. Radiative properties of particulate media. Radiat. Heat Transf. 3rd ed.; Academic Press, 2013; Chapter 12, 387–439.
603 604
Rivière, P.; Soufiani, A. Updated band model parameters for H2O, CO2, CH4 and CO radiation at high temperature. Int. J. Heat Mass Transf. 2012, 55 (13–14), 3349–3358.
601 602
Malkmus, W. Random Lorentz band model with exponential-tailed S-1 line-intensity
Johansson, R.; Leckner, B.; Andersson, K.; Johnsson, F. Influence of particle and gas radiation in oxy-fuel combustion. Int. J. Heat Mass Transf. 2013, 65, 143–152.
(26)
Gronarz, T.; Schnell, M.; Siewert, C.; Schneiders, L.; Schröder, W.; Kneer, R. Comparison
607
of scattering behaviour for spherical and non-spherical particles in pulverized coal
608
combustion. Int. J. Therm. Sci. 2017, 111, 116–128.
609
ACS Paragon Plus Environment
34