Simple and Highly Sensitive Molecular Diagnosis ... - ACS Publications

Nov 15, 2016 - test in less than 5 min. The optimized RT-LAMP combined with the LFA allowed specific ZIKV RNA detection down to the single copy level ...
2 downloads 0 Views 1MB Size
Subscriber access provided by Universiteit Utrecht

Article

Simple and Highly Sensitive Molecular Diagnosis of Zika Virus by Lateral Flow Assays Dohwan Lee, Yong Shin, Seok Chung, Kyo Seon Hwang, Dae Sung Yoon, and Jeong Hoon Lee Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.6b03460 • Publication Date (Web): 15 Nov 2016 Downloaded from http://pubs.acs.org on November 15, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Simple and Highly Sensitive Molecular Diagnosis of Zika Virus by Lateral Flow Assays Dohwan Lee, 1, ‡ Yong Shin, 2, 3, ‡ Seok Chung, 4 Kyo Seon Hwang, 5 Dae Sung Yoon, *, 6 and Jeong Hoon Lee *, 1 1 2

Department of Electrical Engineering Kwangwoon University, 447-1 Wolgye, Nowon, Seoul 01897, Republic of Korea Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Republic of Korea

3

Biomedical Engineering Research Center, Asan Institute of Life Sciences, Asan Medical Center, 88 Olympicro-43gil, Songpa-gu, Seoul, Republic of Korea

4

School of Mechanical Engineering, Korea University, Seoul, 136-703, Republic of Korea Center for BioMicrosystem, Korea Institute of Science and Technology (KIST), Seoul 136-791, Korea 6 School of Biomedical Engineering, Korea University, Seoul, 136-703, Republic of Korea 5

ABSTRACT: We have developed a simple, user-friendly, and highly sensitive Zika virus (ZIKV) detection method by incorporating optimized reverse transcription loop-mediated isothermal amplification (RT-LAMP) and a lateral flow assay (LFA). The optimized RT-LAMP reaction was carried out using Bst 3.0 polymerase, which has robust and fast isothermal amplification performance even in the presence of high concentrations of inhibitors; this permitted the amplification of ZIKV RNA in pure water and human whole blood. In addition, the strong reverse transcription activity of Bst 3.0 polymerase enabled specific ZIKV RNA amplification without extra addition of reverse transcriptase. The RT-LAMP condition was optimized by adjusting the Mg2+ and dNTP mix concentration to extirpate non-target amplification, which is caused by nonspecific primer dimers amplification. After 30 min of RT-LAMP reaction, the resultant amplicons were simply and rapidly analyzed by the LFA test in less than 5 min. The optimized RT-LAMP combined with the LFA allowed specific ZIKV RNA detection down to the single copy level within 35 min.

INTRODUCTION In 2015, an outbreak of Zika virus (ZIKV) in Brazil resulted in more than 4,000 cases of microcephaly in newborns and the infection of 1.5 million people. Explosive spreading of ZIKV in the Americas triggered the World Health Organization to declare it a public health emergency of international concern in February 2016;1–4 this is since ZIKV is suspected as a major cause of congenital microcephaly,5,6 Guillain-Barré syndrome7,8 and other neurologic syndromes.3 ZIKV is a single-stranded, positive-polarity RNA virus of the family Flaviviridae and the genus Flavivirus; it is transmitted by Aedes mosquitoes, which also transmit dengue and chikungunya viruses across tropical and subtropical regions around the world.9 In addition, antigenic similarity between ZIKV and dengue virus gives rise to serological crossreactivity, precluding antibody-based assays from reliably distinguishing between ZIKV and dengue virus infections.10,11 Thus, reliable methods for distinguishing ZIKV from dengue and chikungunya viruses is essential in practical applications. The conventional method for specific ZIKV analysis is based on the reverse transcription-polymerase chain reaction (RT-PCR).12–14 However, RT-PCR requires a bulky and expensive thermal cycler, prolonged reaction time, and trained technicians; these resources are not available in many low and middle income countries.15–17 Moreover, the RT-PCR reaction is vulnerable to inhibitors (blood, plasma, and urine), demanding painstaking and cumbersome RNA extraction

steps.18–20 Recently, a variety of isothermal RNA amplification techniques have been developed to overcome such limitations.21–25 Among them, reverse transcription loopmediated isothermal amplification (RT-LAMP) is a rapid, robust, and highly sensitive isothermal RNA amplification technique that uses four to six primers to amplify specific RNA sequences at 60°C–65°C even in the presence of the inhibitors.26–28 Despite these advantages, the conventional LAMP assays occasionally suffer from non-target amplification yielding false positive results. This is since the higher concentration of primers, ions, and dNTPs in RTLAMP compared with regular RT-PCR, as well as a relatively low reaction temperature, contribute to stabilization of nonspecific primer dimers.29–31 Besides, RT-LAMP inevitably requires the addition of reverse transcriptase to convert viral RNA to DNA. To overcome such drawbacks, we utilized a Bst 3.0 polymerase and optimized RT-LAMP conditions to specifically amplify ZIKV RNA without non-target amplification; the resultant amplicons were analyzed using a simple but highly sensitive lateral flow assay (LFA). The LFA is a superior nucleic acid diagnostic tool owing to its high sensitivity, simplicity, user-friendliness, and easy interpretation of results.32–34 The Bst 3.0 polymerase used in this study has robust and fast isothermal amplification performance even in the presence of high concentrations of inhibitors. It also has strong reverse transcription activity at

ACS Paragon Plus Environment

Analytical Chemistry

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

elevated temperatures up to 72oC. By utilizing these features of Bst 3.0 polymerase, we could rapidly and specifically amplify ZIKV RNA contained in pure water and human whole blood at relatively high temperatures; this was possible without addition of exogenous reverse transcriptase. We also completely eliminated non-target amplification (caused by excessive free Mg2+ ions) by strictly controlling the Mg2+ and dNTP mix concentration in RT-LAMP. In addition, we employed the LFA as an amplicon analysis tool to perform simple, rapid, and user-friendliness detection of ZIKV RNA by merely observing a colorimetric signal with the naked eye. To the best of our knowledge, this is the first demonstration that the combination of optimized RT-LAMP and the LFA can enable rapid and specific ZIKV RNA detection at the single copy level.

EXPERIMENTAL SECTION Materials. NATtrol™ Zika Virus External Run Control (Catalog# NATZIKV-ERCM, strain MR 766), which contains intact ZIKV particles that have been chemically modified to render them non-infectious and refrigerator stable, was purchased from ZeptoMetrix Corporation (NY, USA). ZIKV RNA was extracted using AccuPrep® Viral RNA Extraction Kit (Bioneer, Seoul, Korea). Bst 3.0 DNA polymerase, 10 × Isothermal Amplification Buffer II, and 100 mM MgSO4 were obtained from New England BioLabs (MA, USA). dGTP, dATP, dCTP, dTTP solutions (100 mM) and 1 mM of biotin18-dUTP were provided by Jena Bioscience (Jena, Germany). Primers specifically targeting ZIKV were synthesized by Bioneer (Seoul, Korea) and LFA kits and diluent buffer were purchased from Medisensor Inc. (Daejeon, Korea). Single donor human whole blood was obtained from Innovative Research, Inc. Design and Operation of the LFA. Figure 1A shows the detailed setup of the LFA in this study. The LFA platform contains a buffer loading pad, a conjugate pad, a test line, a control line, and an absorbent pad. Streptavidin-coated gold nanoparticles (AuNPs) were gathered in the conjugate pad, and anti-digoxigenin and biotin were also affixed at the test line and control line, respectively. The schematic illustration of the LFA operation procedures are shown in Figure 1B. First, 1 µL of digoxigenin and biotin-labeled RT-LAMP products was loaded into the conjugate pad, so that the biotinlabeled RT-LAMP products formed a complex with AuNPs via streptavidin-biotin interactions. Next, 45 µL of diluent buffer was added to the buffer loading pad, and the capillary flow transferred AuNPs from the conjugate pad to the test and control line. The AuNP/RT-LAMP complexes were immobilized at the test line by interaction between digoxigenin and anti-digoxigenin, whereas the AuNPs that did not form complexes were captured by biotin. Complexed and non-complexed AuNPs are indicated by violet bands at the test and control line, respectively. The colorimetric signal was easily visible to the naked eye within 5 min. Specific RT-LAMP Primer Design. To clearly distinguish ZIKV from other arboviruses such as dengue and chikungunya viruses, highly specific RT-LAMP primers that do not crossreact with other arboviruses is essential. The envelope protein coding region of ZIKV is highly homologous between ZIKV strains, but highly divergent from the other flaviviruses.35 Therefore, we selected the envelope protein coding region as a target gene. The genomic sequence of ZIKV (accession no.:

Page 2 of 8

AY632535) was obtained from Genbank and six RT-LAMP primers, including inner primers (FIP/BIP), outer primers (F3/B3), and loop primers (LF/LB), were designed using the Primer Explorer V4 program available on the Eiken website (https://primerexplorer.jp/e/), as shown in the Supplementary Data (Figure S-1). Then, each of six primers was checked to verify their specificity by conducting BLAST searches. Figure S-2 shows that the RT-LAMP primers were highly specific for ZIKV. LF and LB primers required for accelerating the amplification were labeled with digoxigenin, allowing the resultant amplicons to be captured on the test line. The primer sequences are shown in Table 1, and the ZIKV strains that can be detected using our primers are listed in Figure S-3. Since our primers were designed based on the ZIKV strain MR 766 (Uganda), most of African lineages are specifically detectable using our primers. However, these might not be suitable for Latin American and Asian lineages owing to several point of mismatch in the primer sequence. To cover all ZIKV lineages, extra primers based on Latin American and Asian lineages are expected to be required. Specific RT-LAMP-Dependent Amplification of ZIKV RNA. To amplify ZIKV RNA under isothermal conditions without non-target amplification, we utilized the optimized RT-LAMP reaction and Bst 3.0 DNA polymerase. Bst 3.0 DNA polymerase has improved isothermal amplification performance and strong reverse transcription at elevated temperatures (up to 72oC), so that total reaction time was reduced to 30 min, and addition of exogenous reverse transcriptase is not required. The stability of Bst 3.0 at elevated temperatures minimizes non-target amplification problem by preventing the formation of primer dimers. The RT-LAMP reaction was carried out in a 25-µL reaction mixture containing 1 × Isothermal Amplification Buffer II (20 mM Tris-HCl, 10 mM (NH4)2SO2, 150 mM KCl, 2 mM MgSO4, 0.1% Tween® 20), an additional 2 mM MgSO4, dNTP mix included with biotin-dUTP (2.2 mM dGTP, dATP, dCTP, 1.375 mM dTTP, and 0.0825 mM biotin-dUTP), targetspecific primer mixture (0.8 µM forward and reverse inner primers, 0.4 µM digoxigenin-labeled loop primers and 0.2 µM forward and reverse outer primers, see Table 1), 8 U of Bst 3.0 DNA polymerase, and 2 µL of a purified ZIKV RNA or human whole blood spiked with ZIKV RNA ranging from 106 copies to single copy. The RT-LAMP reaction mixture was incubated at 72oC for 30 min. Preparation of Purified ZIKV RNA and Human Whole Blood Sample Spiked with ZIKV RNA. Intact ZIKV particles in a purified protein matrix were artificially injected into human whole blood. ZIKV RNA was extracted using AccuPrep® Viral RNA Extraction Kit (Bioneer, Seoul, Korea) and the concentration of the purified RNA was quantified using a Colibri Microvolume Spectrometer (Titertek Berthold, Germany). Then, the extracted ZIKV RNA was serially diluted to control the concentration from 106 copies to single copy per 2 µL. In direct RT-LAMP experiments, the extracted ZIKV RNA was spiked into human whole blood to mimic real ZIKV blood specimens. Then, human whole blood was serially diluted with more blood to control the concentration from 106 copies to single copy per 2 µL and directly used as a sample without additional RNA extraction and purification steps. Optimization of the RT-LAMP Reaction. To optimize RT-LAMP assays, non-target amplification must be

ACS Paragon Plus Environment

Page 3 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

completely eliminated. This is achieved by strictly controlling the concentration of Mg2+ and dNTPs.30,31,36 We optimized the concentration of Mg2+ and dNTP mix, wherein the ratio of dTTP and biotin-dUTP in dNTP was fixed to 55:3.3 based on previous reports.34,37 Four different Mg2+ concentrations (2 mM, 4 mM, 6 mM, and 8 mM) and five different concentrations of dNTP (0.6 mM, 1 mM, 1.4 mM, 1.8 mM, and 2.2 mM) were examined to determine their optimal concentrations.

RESULTS AND DISCUSSION Optimization of Mg2+ and dNTP Mix Concentrations. When new RT-LAMP assays are optimized, non-target amplification caused by nonspecific primer dimers must be confirmed. Although Mg2+ ions act as a cofactor for Bst polymerase, excessive free Mg2+ ions can stabilize nonspecific primer dimers, resulting in a pseudo-positive result even in the negative sample. Moreover, they can also bind to dNTPs and templates, which can also produce a misleading result. Owing to the multi-functionality of Mg2+ mentioned above, it is plausible that Mg2+ ions significantly affect the specificity of LAMP assays.15,30,36 In addition, dNTPs directly chelate a proportional number of Mg2+ ions, affecting the concentration of available free Mg2+ ions in LAMP reaction buffer.38–40 Accordingly, optimizing the concentration of Mg2+ and dNTP mix required to set up a reliable ZIKV bioassay. First, we performed agarose gel electrophoresis to optimize the concentration of Mg2+ ions in the RT-LAMP reaction (Figure 2A) and the LFA (Figure 2B); this was performed at a fixed (2.2 mM) concentration of dNTP mix. At 2 mM Mg2+, both positive and the negative controls failed to produce any amplification owing to insufficient Mg2+ ions. At 6 mM and 8 mM Mg2+, both of the positive and the negative controls displayed the amplification bands, indicating non-target amplification. The only concentration that clearly distinguished between positive and negative controls was 4 mM Mg2+. At this concentration, no bands or signals representing non-target amplification were present (this experiment was repeated 10 times). We also optimized the concentration of dNTP mix (Figure 3) while fixing the Mg2+ concentration at 4 mM. Although there was a slight difference in the amplification pattern between positive and negative controls in the gel electropherogram (Figure 3A), non-target amplification clearly occurred at dNTP mix concentrations less than 1.8 mM. Similar results were obtained in the LFA (Figure 3B). Specifically, distinctive ZIKV detection in the gel electropherogram and the corresponding LFA was obtained only with 2.2 mM dNTP mix. Importantly, the above tests were all conducted at 72oC for 30 min, using Bst 3.0 polymerase without addition of exogenous reverse transcriptase. From these results, we conclude that the optimal concentrations of Mg2+ and dNTP mix for optimized RTLAMP reaction are 4 mM and 2.2 mM, respectively. RT-LAMP Reaction-Time Control. After the optimization of Mg2+ and dNTP mix concentration, we investigated the minimal reaction time required to produce reliable bioassay results. Figure 4A shows that an amplification band first appeared after 30 min, and the band intensities appeared to saturate after 40 min. The trends of results from the LFA were similar (Figure 4B) and negative samples did not show the band on the test line (Figure 4C). The above results imply that a RT-LAMP reaction-time of less than 20 min is insufficient

to detect ZIKV. Accordingly, we selected 30 min as the minimum reaction time for subsequent tests. Limit of Detection Test using Extracted RNA. Encouraged by the successful optimization of ZIKV RTLAMP reaction, we performed a limit of detection test on the LFA to evaluate whether our method is indeed highly sensitive. The extracted ZIKV RNA was serially diluted to from 106 copies to a single copy per 2 µL. Figure 5A shows the ZIKV RNA detection results for the LFA. The signal intensities on the test line gradually declined as the concentration of ZIKV RNA decreased. Notably, the existence of even a single copy of ZIKV RNA could be detected with the LFA. The calibration curve indicated a linear relationship (R2 = 0.91139) between the colorimetric intensities on the test line and the copy number of extracted ZIKV RNA (Figure 5B). Although the quantitative accuracy of the LFA is debated, we believe that these results indicate that extracted ZIKV RNA can be simply quantified by measuring the colorimetric intensities on the test lines. Thus, the combination of our optimized RT-LAMP reaction and the LFA identifies ZIKV RNA more rapidly and with a higher sensitivity than previously reported methods (Table S-1). Limit of Detection Test using Non-purified RNA. Since Bst polymerase used in the conventional LAMP assays is less affected by inhibitors, the LAMP format can be used to amplify the target DNA even in the presence of biological fluids such as blood, plasma, urine, and saliva.26–28,37 The Bst 3.0 polymerase used in this study retains both improved isothermal amplification performance and strong reverse transcription activity, allowing us to avoid the inhibition of reverse transcription by biological substances. By utilizing the advantages of Bst 3.0 polymerase, we demonstrated a direct RT-LAMP reaction and LFA detection of ZIKV RNA in human whole blood, which did not require any RNA extraction steps (Figure 5C). In common with the results for extracted RNA, the LFA results from blood samples showed a gradual reduction of signal intensity on the test line as the concentration of ZIKV RNA was decreased. Again, even a single copy of ZIKV RNA was also detectable. Taken together, these results imply that our method has great potential utility for the effective diagnosis of ZIKV infections. Quantification analysis of the LFA for human whole blood was also conducted. There was a linear (R2 = 0.96498) relationship between the colorimetric intensities on the test line and the copy number of ZIKV RNA (Figure 5D).

CONCLUSIONS In this study, we successfully identified ZIKV RNA in pure water and human whole blood by a combination of RT-LAMP and the LFA. The procedure is highly sensitive, rapid, and simple to perform. Optimizing the RT-LAMP reaction by controlling the concentrations of Mg2+ and dNTP mix completely eliminated non-target amplification. In addition, the direct RT-LAMP reaction could directly amplify ZIKV RNA from human whole blood without the need of special equipment such as an ultracentrifuge or thermal cycler. The resultant amplicons were also easily quantifiable by the LFA. We thus report a simple, rapid, and user-friendly ZIKV detection method that can be exploited as part of an economic and simple point-of-care (POC) system. Although we have developed new effective ZIKV assay, we conceded that evaluation of real infected patients’ blood as

ACS Paragon Plus Environment

Analytical Chemistry

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

well as validation of other samples such as urine, semen, amniotic fluid, cerebrospinal fluid are seen to be necessary. We are now trying to do on-going works for addressing these issues by cooperating with hospital.

Page 4 of 8

Larre, P.; Vial, A.-L.; Decam, C.; Choumet, V.; Halstead, S. K.; Willison, H. J.; Musset, L.; Manuguerra, J.-C.; Despres, P.; Fournier, E.; Mallet, H.-P.; Musso, D.; Fontanet, A.; Neil, J.; Ghawché, F. Lancet 2016, 387, 1531–1539. (8)

Oehler, E.; Watrin, L.; Larre, P.; Leparc-Goffart, I.; Lastere, S.; Valour, F.; Baudouin, L.; Mallet, H.; Musso, D.; Ghawche, F. Euro Surveill. 2014, 19, 7–9.

(9)

Surveillance and Control of Aedes aegypti and Aedes albopictus in the United States. http://www.cdc.gov/chikungunya/resources/ vector-control.html (accessed July 25)

(10)

Revised diagnostic testing for Zika, chikungunya, and dengue viruses in US Public Health Laboratories. https://www.cdc.gov/ zika/pdfs/denvchikvzikv-testing-algorithm.pdf (accessed July 25)

(11)

Dejnirattisai, W.; Supasa, P.; Wongwiwat, W.; Rouvinski, A.; Barba-spaeth, G.; Duangchinda, T.; Sakuntabhai, A.; Malasit, P.; Rey, F. A.; Mongkolsapaya, J.; Screaton, G. R. Nat. Immunol. 2016.

* [email protected]

(12)

Faye, O.; Faye, O.; Dupressoir, A.; Weidmann, M.; Ndiaye, M.; Alpha Sall, A. J. Clin. Virol. 2008, 43, 96–101.

* [email protected]

(13)

Faye, O.; Faye, O.; Diallo, D.; Diallo, M.; Weidmann, M.; Sall, A. A. Virol. J. 2013, 10, 311.

Author Contributions

(14)

Gourinat, A. C.; O'Connor, O.; Calvez, E.; Goarant, C.; DupontRouzeyrol, M. Emerg. Infect. Dis. 2015, 21, 84–86.

(15)

Zhao, Y.; Chen, F.; Li, Q.; Wang, L.; Fan, C. Chem. Rev. 2015, 115, 12491–12545.

(16)

Chang, C. C.; Chen, C. C.; Wei, S. C.; Lu, H. H.; Liang, Y. H.; Lin, C. W. Sensors 2012, 12, 8319–8337.

(17)

Connelly, J. T.; Rolland, J. P.; Whitesides, G. M. Anal. Chem. 2015, 87, 7595–7601.

(18)

Schrader, C.; Schielke, A.; Ellerbroek, L.; Johne, R. J. Appl. Microbiol. 2012, 113, 1014–1026.

ASSOCIATED CONTENT Supporting Information The Supporting Information is available free of charge on the ACS Publications website at DOI: Figure S-1: Primer design; Figure S-2: Specificity validation using BLAST program; Figure S-3: Detectable ZIKV strains; Table S-1: The comparison with other ZIKV assays (PDF)

AUTHOR INFORMATION Corresponding Author



These authors contributed equally.

Notes The authors declare no competing financial interests.

ACKNOWLEDGMENTS This work was supported by the National Research Foundation of Korea Grant funded by the Korean Government (MEST) (NRF2015R1D1A1A01059806) and by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (Grant number: HI16C0272). J. H. Lee was also supported by a Research Grant from Kwangwoon University in 2016.

REFERENCES

(1)

(2)

(3)

Lessler, J.; Chaisson, L. H.; Kucirka, L. M.; Bi, Q.; Grantz, K.; Salje, H.; Carcelen, A. C.; Ott, C. T.; Sheffield, J. S.; Ferguson, N. M.; Cummings, D. A. T.; Metcalf, C. J. E.; Rodriguezbarraquer. Science 2016, 353, aaf8160. Zika virus outbreak: These places are most at risk. http://www. cbsnews.com/pictures/zika-virus-outbreak-these-places-are-most -at-risk/ (accessed July 25) WHO statement on the first meeting of the International Health Regulations (2005) (IHR 2005) Emergency Committee on Zika virus and observed increase in neurological disorders and neonatal malformations. http://www.who.int/mediacentre/news/ statements/2016/1st-emergency-committee-zika/en/ (accessed July 25)

(4)

Focosi, D.; Maggi, F.; Pistello, M. Clin. Infect. Dis. 2016, 63, 1– 26.

(5)

Schuler-Faccini, L.; Ribeiro, E.; Feitosa, I.; Horovitz, D.; Cavalcanti, D.; Pessoa, A.; Doriqui, M.; Neri, J.; Neto, J.; Wanderley, H.; Cernach, M.; El-Husny, A.; Pone, M.; Serao, C.; Sanseverino, M. MMWR Morb Mortal Wkly Rep 2016, 65, 5962.

(6)

Victora, C. G.; Schuler-Faccini, L.; Matijasevich, A.; Ribeiro, E.; Pessoa, A.; Barros, F. C. Lancet 2016, 387, 621–624.

(7)

Cao-Lormeau, V.-M.; Blake, A.; Mons, S.; Lastère, S.; Roche, C.; Vanhomwegen, J.; Dub, T.; Baudouin, L.; Teissier, A.;

(19)

Alaeddini, R. Forensic Sci. Int. Genet. 2012, 6, 297–305.

(20)

Khan, G.; Kangro, H. O.; Coates, P. J.; Heath, R. B. J. Clin. Pathol. 1991, 44, 360–365.

(21)

Compton, J. Nature 1991, 350, 91–92.

(22)

Notomi, T.; Okayama, H.; Masubuchi, H.; Yonekawa, T.; Watanabe, K.; Amino, N.; Hase, T. Nucleic Acids Res. 2000, 28, e63.

(23)

Vincent, M.; Xu, Y.; Kong, H. EMBO Rep. 2004, 5, 795–800.

(24)

Piepenburg, O.; Williams, C. H.; Stemple, D. L.; Armes, N. A. PLoS Biol. 2006, 4, 1115–1121.

(25)

Fire, a; Xu, S. Q. Proc. Natl. Acad. Sci. U. S. A. 1995, 92, 4641–4645.

(26)

Safavieh, M.; Kanakasabapathy, M. K.; Tarlan, F.; Ahmed, M. uddin; Zourob, M.; Asghar, W.; Shafiee, H. ACS Biomater. Sci. Eng. 2016, 2, 278-294.

(27)

Nyan, D.-C.; Ulitzky, L. E.; Cehan, N.; Williamson, P.; Winkelman, V.; Rios, M.; Taylor, D. R. Clin. Infect. Dis. 2014, 59, 16–23.

(28)

Nie, K.; Qi, S. xiang; Zhang, Y.; Luo, L.; Xie, Y.; Yang, M. jie; Zhang, Y.; Li, J.; Shen, H.; Li, Q.; Ma, X. jun. PLoS One 2012, 7, e52486.

(29)

Senarath, K. D.; Usgodaarachchi, R. B.; Navaratne, V.; Nagahawatte, A.; Wijayarathna, C. D.; Alvitigala, J.; Goonasekara, C. L. J. Tuberc. Res. 2014, 2, 168–172.

(30)

Wang, D. G.; Brewster, J. D.; Paul, M.; Tomasula, P. M. Molecules 2015, 20, 6048–6059.

(31)

Liu, J.; Xu, L.; Guo, J.; Chen, R.; Grisham, M. P.; Que, Y. Biomed Res. Int. 2013.

(32)

Posthuma-Trumpie, G. A.; Korf, J.; Van Amerongen, A. Anal. Bioanal. Chem. 2009, 393, 569–582.

(33)

Sajid, M.; Kawde, A. N.; Daud, M. J. Saudi Chem. Soc. 2015, 19, 689–705.

ACS Paragon Plus Environment

Page 5 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Figure 1. Design and operation procedures of the LFA. (A) The detailed structure of the LFA. (B) The schematic illustration of the LFA operation procedures: (i) 1 µL RT-LAMP products was loaded into the conjugate pad, (ii) 45 µL of diluent buffer was dropped to buffer loading pad, and (iii) The capillary flow transferred AuNPs from conjugate pad to the test and control line. (34)

Jung, J. H.; Oh, S. J.; Kim, Y. T.; Kim, S. Y.; Kim, W.-J.; Jung, J.; Seo, T. S. Anal. Chim. Acta 2015, 853, 541–547.

(35)

Song, J.; Mauk, M. G.; Hackett, B. A.; Cherry, S.; Bau, H. H.; Liu, C. Anal. Chem. 2016, 88, 7289–7294.

(36)

Su, Y.; Yang, Y.; Peng, Q.; Zhou, D.; Chen, Y.; Wang, Z.; Xu, L.; Que, Y. Sci. Rep. 2016, 6, 23994.

(37)

Lee, D.; Kim, Y. T.; Lee, J. W.; Kim, D. H.; Seo, T. S. Biosens. Bioelectron. 2016, 79, 273–279.

(38)

Waterfall, C. M.; Cobb, B. D. Nucleic Acids Res. 2001, 29, e119.

(39)

Qiu, X.; Li, T.; Zhang, G.; Cao, J.; Jin, Y.; Xing, G.; Liao, M.; Zhou, J. Virol. J. 2012, 9, 318.

Figure 2. Optimization of Mg2+ concentrations. The indicated Mg2+ concentrations were examined by (A) agarose gel electrophoresis and (B) the LFA. The ‘+’ symbols and ‘-’ symbols indicate positive controls using 106 copies per 2 µL of ZIKV RNA and the negative control (no ZIKV RNA), respectively. (40)

Roux, K. H. Cold Spring Harb. Protoc. 2009, 4, 1–7.

ACS Paragon Plus Environment

Analytical Chemistry

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Figure 3. Optimization of dNTP mix concentrations. The indicated dNTP mix concentrations were examined by (A) agarose gel electrophoresis and (B) the LFA. The ‘+’ symbols and ‘-’ symbols indicate positive control using 106 copies per 2 µL of ZIKV RNA) and the negative control (no ZIKV RNA), respectively.

Page 6 of 8

Figure 4. RT-LAMP reaction time control. Reaction times between 10 min and 50 min were evaluated, and the amplicons were analyzed by (A) agarose gel electrophoresis and (B) the LFA with a single copy of ZIKV RNA. (C) Negative controls were also evaluated by the LFA. All experiments were repeated three times.

ACS Paragon Plus Environment

6

Page 7 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Analytical Chemistry

Figure 5. (A) Limit of detection test using extracted RNA. The extracted ZIKV RNA was serially diluted (from 106 copies to a single copy per 2 µL) and used as a template. (B) Calibration curve showing linear relationship (R2 = 0.91139) between the colorimetric intensities on the test line and the copy number of extracted ZIKV RNA. (C) Limit of detection test without RNA extraction. Human whole blood spiked with ZIKV RNA was serially diluted with blood (from 106 copies to a single copy per 2 µL) and directly used as a sample. (D) Calibration curve showing a linear relationship (R2 = 0.96498) between the colorimetric intensities on the test line and the copy number of ZIKV RNA in human whole blood. Table 1. Specific RT-LAMP Primer sequences.

ACS Paragon Plus Environment

7

Analytical Chemistry

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 8

For TOC only

ACS Paragon Plus Environment

8