Sorption Properties of a Single Wall Carbon Nanotube - Journal of

Sep 19, 2008 - The CO2 isotherm was measured at 273 K with the PSA up to 1 bar. The H2 isotherms was measured at 77 K in the PSA rig up to 1.05 bar an...
0 downloads 0 Views 63KB Size
J. Chem. Eng. Data 2008, 53, 2451–2453

2451

Sorption Properties of a Single Wall Carbon Nanotube C. Guan, Leslie S. Loo, C. Yang, and K. Wang* School of Chemical & Biomedical Engineering, Nanyang Technological University, Singapore

The sorption properties of a single wall carbon nanotube were measured for a number of gases. The N2 and H2 isotherms were measured at 77 K, while the CO2 isotherms were measured at 273 K. The data may serve the purpose of design and characterization of carbon nanotubes in sorption applications.

Table 1. Properties of the SWCNTa

Introduction Carbon nanotubes (CNTs) have found numerous applications due to their unique mechanical, electrical, and chemical properties. The sorption properties of CNTs were extensively explored in such applications as chemical/biosensors,1 sorbents for energy storage,2 and nanofillers in composite membranes,3 etc. For example, H2 storage in CNTs has been a much sought-after area, although both encouraging2 and discouraging4 results have been reported. CNTs consist of graphite pores of cylindrical configuration which may present both high sorption potential and selectivity for molecules with specific structure and dimension. Some experimental and simulation studies showed that CNTs have the potential to achieve high H2 capacity [(5 to 14) % weight percentage] at ambient temperature if the structure is optimized,5-8 while some other studies show that the optimal temperature for H2 storage delivery should be much lower at ∼ 115 K to meet the DOE (Department of Energy, U.S.A.) standard of 6 wt % at ambient conditions.9 The sorption mechanisms in CNTs are also a subject of controversy. While most researchers agree that the cylindrical graphite pores (inner tubes) offer most of the capacities for physical sorption,5 the role of the external surface, the corners within the tube bundles, the defects, and the functional groups, etc. were not fully understood.10-12 For example, Lee et al. found the existence of a strong steric barrier for the transport of H2 in nanotubes.13 Ye et al. observed a phase transition in single wall carbon nanotube (SWCNT) at 77 K.14 Lee and Lee reported that excessive H2 sorption may lead to the breakdown of the tube structure.7 The NREL (National Renewable Energy Laboratory, U.S.A.) demonstrated the ability for SWCNTs to store substantial quantities of hydrogen at ambient conditions via hydrogenation with reduced binding energies.15 This article will report the sorption properties of N2, H2, and CO2 on a high purity, commercial single wall carbon nanotube. These isotherms cover a range of experimental pressures and temperatures.

Experimental Section The SWCNT was acquired from CheapTube Inc., U.S.A. Table 1 lists the properties of the sample. A pore and surface analyzer (PSA, Quantachrome, Autosorb1) was used to measure the N2 isotherm at 77 K. The specific surface area (SBET) was determined using the Brunauer-Emmett* Corresponding author. E-mail: [email protected].

purity

ash

OD

surface area -1

> 90 % < 1.5 % (1 to 2) nm > 407 m · g 2

a

length

EC -2

(5 to 30) µm > 10

s · cm-1

Note: OD ) outer diameter; EC ) electrical conductivity.

Figure 1. N2 isotherm (a) and the derived PSD (b) on the SWCNT.

Teller (BET) method in the relative pressure range of 0.05 to 0.3. The CO2 isotherm was measured at 273 K with the PSA up to 1 bar. The H2 isotherms was measured at 77 K in the PSA rig up to 1.05 bar and in a high pressure volumetric rig up to 10 bar. Prior to measurements, the SWCNT samples were degassed at 250 °C overnight under high vacuum.

Results and Discussion Figure 1a shows the N2 isotherm measured at 77 K on the SWCNT. The measured SBET derived from the N2 is 420 m2 · g-1. The total pore volume of the sample is ∼ 0.70 cc · g-1, and the micropore volume is ∼ 0.12 cc · g-1. The embedded Figure 1b shows the pore size distribution (PSD) of the SWCNT derived from the N2 isotherm via the NLDFT (nonlocal density functional theory) which assumes a cylindrical graphite pore geometry. It is seen that the sample has a sharp volume peak at the pore diameter of ∼1.1 nm and a minor peak at ∼2.0 nm, which is consistent with the information in Table 1 that tube OD ) (1 to 2) nm. Meanwhile, a large portion of the pore volume (as well as surface area) was seen to be contributed by tubes with a diameter above 2 nm. This apparent discrepancy with the product specifications (confirmed by the SEM/TEM images) is probably due to the sorption at the external surface of the tubes and the void space formed among the CNT bundles,

10.1021/je800455a CCC: $40.75  2008 American Chemical Society Published on Web 09/19/2008

2452 Journal of Chemical & Engineering Data, Vol. 53, No. 10, 2008 Table 2. Isotherm Data on SWCNT pressure

adsorbed

pressure

adsorbed

pressure

adsorbed

pressure

adsorbed

bar

STPcc · g-1

bar

STPcc · g-1

bar

STPcc · g-1

bar

STPcc · g-1

3.000 · 10-5 3.600 · 10-5 6.200 · 10-5 6.200 · 10-5 8.300 · 10-5 1.660 · 10-4 5.120 · 10-4 8.320 · 10-4 9.940 · 10-4 1.081 · 10-3 2.392 · 10-3 3.609 · 10-3 5.221 · 10-3 6.239 · 10-3 7.490 · 10-3 0.01345 0.01896 0.02553 0.02938 0.03959 0.05069 0.06185 0.06854 0.0748 0.08064 0.09267

3.089 3.298 3.508 3.927 4.595 12.1 21.36 33.42 59.45 62.66 70.84 74.33 77.22 78.64 80.05 84.67 87.61 90.34 91.72 94.95 98.01 100.8 102.5 103.9 105.3 108

0.09944 0.1256 0.1512 0.176 0.2008 0.2254 0.2499 0.2745 0.299 0.3235 0.3479 0.3725 0.4004 0.4225 0.4495 0.4746 0.4993 0.5233 0.5489 0.5721 0.5961 0.6233 0.6479 0.6716 0.6985 0.7232

274.9 286.4 299.8 313.5 329.2 344.8 360.6 376 387.7 401.7 419.8 409.8 397.9 388.6 382.7 375.4 369.4 360.3 349.7 338.6 324.2 311.4 297 282.6 270.1 257.4

0.6011 0.5757 0.5516 0.5255 0.5 0.4789 0.4513 0.4286 0.4037 0.3764 0.3528 0.3241 0.3009 0.2762 0.2512 0.225 0.1994 0.1739 0.1237 9.920 · 10-2 7.470 · 10-2 5.080 · 10-2 2.590 · 10-2 1.990 · 10-2 1.780 · 10-2 1.260 · 10-2

245.3 234.7 225.4 216.1 208 201.6 190.6 182.5 175.7 169.1 163.9 157.6 152.6 147.3 142 136.6 131.2 125.8 115.2 109.8 104.2 98.37 90.79 88.33 87.34 84.41

6.315 · 10-4 1.053 · 10-3 1.264 · 10-3 5.792 · 10-3 0.0575 0.0820 0.0938 0.1276 0.1415 0.1824 0.2099

0.067 0.097 0.11 0.331 2.848 3.729 4.103 5.117 5.491 6.056 6.725

0.2641 0.3273 0.3741 0.4261 0.4734 0.5313 0.5841 0.6374 0.6896 0.7428 0.7955

CO2 (T ) 273 K) 8.02 0.8477 9.448 0.9004 10.43 0.9527 11.53 1.0056 12.48 1.0520 13.58 14.61 0.9939 15.57 0.9405 16.5 0.8876 17.43 0.8351 18.33 0.7824

1.000 · 10-4 6.000 · 10-4 1.100 · 10-3 5.300 · 10-3 8.440 · 10-3 0.152 0.194 0.223

0.3136 0.9408 1.456 4.01 18.61 25.45 28.92 31.02

0.238 0.247 0.252 0.26 0.323 0.381 0.422 0.481

32.1 32.68 33.04 33.64 37.43 40.45 42.49 45.11

109.5 115.2 120.5 125.7 130.9 136 141.1 146.3 151.5 156.7 162 167.3 173.4 178.3 184.3 190 195.8 201.7 207.8 213.9 220.4 228.3 236.1 244.2 254 263.7

N2 (T ) 77 K) 0.7485 0.7724 0.7973 0.8214 0.847 0.8716 0.8967 0.924 0.9469 0.9726 0.992 0.9769 0.9525 0.9253 0.9039 0.8741 0.8537 0.8263 0.8015 0.7788 0.7514 0.7289 0.7029 0.6765 0.6532 0.6277

H2 (T ) 77 K) 0.531 0.583 0.636 0.689 0.741 0.793 0.844 0.901

which constitutes a major volume contribution of mesopores. The desorption hysteresis confirms the existence of mesopore volume in the sample. The data are listed in Table 2. Figure 2 shows the sorption isotherm of CO2 measured on the sample at 273 K (the sample cell was submerged in an ice bath during the experiment). As the sorption pressure is low (P0 ) 1.05 bar), CO2 adsorbed moderately, and no hysteresis was observed between the adsorption and desorption isotherms. A small hump was seen at P/P0 ) 0.18, which may be related to the transition of adsorption from the internal tubes to the external voids/surfaces.12 Simulation studies are needed to understand the underlying mechanisms at this point. The experimental data are listed in Table 2. Finally, the H2 isotherm measured on the SWCNT at 77 K is shown in Figure 3, which combines the data from the PSA (P < 1.05 bar, solid circles) and the high pressure volumetric rig (1.05 bar < P < 10 bar, open circles). It is seen that the isotherm data measured with the two rigs agree with each other reasonably well. The H2 isotherm data are listed in Table 2 and

19.22 20.1 20.99 21.85 22.63 21.68 20.8 19.91 19.01 18.11 47.13 49.1 50.98 52.77 54.32 55.84 57.32 58.96

0.7307 0.6256 0.5727 0.5206 0.4583 0.4145 0.3719 0.3138 0.2598

17.22 15.36 14.39 13.38 12.18 11.28 10.39 9.144 7.917

0.953 1.01

60.21 61.62

1.11 2.58 4.89 6.8 10.62

59.45 77.35 84.43 93.54 94.66

were fitted to the Langmuir equation [Cµ ) CµsbP/(1 + bP), where b is the sorption affinity, P is the pressure, and Cµs is the saturation capacity of the SWCNT]. The fitting parameters are listed in the caption of Figure 3. The isotherm data revealed

Figure 2. CO2 isotherm at 273 K on the SWCNT (P0 ) 1.05 bar).

Journal of Chemical & Engineering Data, Vol. 53, No. 10, 2008 2453

Figure 3. H2 isotherm on SWCNT at 77 K. The fitting parameters of the Langmuir isotherm are: Cµs ) 95 ccSTP · g-1, b ) 1.93 bar-1.

that the SWCNT presents an H2 sorption capacity of ∼ 0.9 wt % at 77 K and 10 bar. This capacity is mainly determined by the micropore volume and the tube sizes of the SWCNT sample.

Conclusion The sorption isotherms of N2 and H2 were measured for a SWCNT at 77 K, while the CO2 isotherm was measured at 273 K. The SWCNT was found to have a major tube diameter distribution at 0.11 nm, but the external surface and the void space among the CNT bundles constitute the major contribution of mesopore volume. The H2 sorption capacity of the sample is found to be ∼ 0.9 wt % at 77 K and 10 bar.

Literature Cited (1) Chopra, S.; McGuire, K.; Gothard, N.; Rao, A. M.; Pham, A. Selective gas detection using a carbon nanotube sensor. Appl. Phys. Lett. 2003, 83, 2280–2282.

(2) Dillon, A. C.; Heben, M. J. Hydrogen storage using carbon adsorbents: past, present and future. Appl. Phys. A: Mater. Sci. Proc. 2001, 72, 133–142. (3) Cong, H.; Zhang, J.; Radosz, M.; Shen, Y. Carbon nanotube composite membranes of brominated poly(2,6-diphenyl-1,4-phenylene oxide) for gas separation. J. Membr. Sci. 2007, 294, 178–185. (4) Zhang, C.; Lu, X.; Gu, A. How to accurately determine the uptake of hydrogen in carbonaceous materials. Int. J. Hydrogen Energy 2004, 29, 1271–1276. (5) Dillon, A. C.; Jones, K. M.; Bekkedahl, T. A.; Kiang, C. H.; Bethune, D. S.; Heben, M. J. Storage of hydrogen in single-walled carbon nanotubes. Nature 1997, 386, 377–379. (6) Zhou, L.; Zhou, Y.; Sun, Y. Studies on the mechanism and capacity of hydrogen uptake by physisorption-based materials. Int. J. Hydrogen Energy 2006, 31, 259–264. (7) Lee, S. M.; Lee, Y. H. Hydrogen storage in single-walled carbon nanotubes. Appl. Phys. Lett. 2000, 76, 2877–2879. (8) Chen, Y.; Shaw, D. T.; Bai, X. D.; Wang, E. G.; Lund, C.; Lu, W. M.; Chung, D. D. L. Hydrogen storage in aligned carbon nanotubes. Appl. Phys. Lett. 2001, 78, 2128–2130. (9) Bhatia, S. K.; Myers, A. L. Optimum Conditions for Adsorptive Storage. Langmuir 2006, 22, 1688–1700. (10) Cheng, H.-M.; Yang, Q.-H.; Liu, C. Hydrogen storage in carbon nanotubes. Carbon 2001, 39, 1447–1454. (11) Chen, C.-H.; Huang, C.-C. Hydrogen storage by KOH-modified multiwalled carbon nanotubes. Int. J. Hydrogen Energy 2007, 32, 237– 246. (12) Wongkoblap, A.; Do, D. D.; Wang, K., Adsorption of Polar and Non Polar Fluids in Nanotubes Bundles: Computer Simulation and Experiment Studies. Langmuir 2008. (13) Lee, S. M.; An, K. H.; Lee, Y. H.; Seifert, G.; Frauenheim, T. Novel mechanism of hydrogen storage in carbon nanotubes. J. Korean Phys. Soc. 2001, 38, 686–91. (14) Ye, Y.; Ahn, C. C.; Witham, C.; Fultz, B.; Liu, J.; Rinzler, A. G.; Colbert, D.; Smith, K. A.; Smalley, R. E. Hydrogen adsorption and cohesive energy of single-walled carbon nanotubes. Appl. Phys. Lett. 1999, 74, 2307–2309. (15) Heben, M. J. FY 2007 Annual Progress Report, DOE Hydrogen Program; DOE Hydrogen Sorption Center of Excellence: 2008; pp 525-530. Received for review June 24, 2008. Accepted August 18, 2008.

JE800455A