Thermodynamics: Second Law Analysis - American Chemical Society

commodities that is used up as a process proceeds, and it is the available energy, then, that is worth paying for. In economic decision making, it thu...
3 downloads 6 Views 1MB Size
9 Available-Energy Costing

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

GORDON M. REISTAD Department of Mechanical Engineering, Oregon State University, Corvallis, OR 97331 RICHARD A. GAGGIOLI Department of Mechanical Engineering, Marquette University, 1515 W. Wisconsin Ave., Milwaukee, WI 53233

It is the available energy content of the commonly labeled "energy" commodities, not their energy, which really represents their potential to cause changes such as to do work, heat, convert chemicals, etc. Consequently, it is the available energy of these commodities that is used up as a process proceeds, and it is the available energy, then, that is worth paying for. In economic decision making, it thus makes sense to do available energy accounting rather than the energy accounting that is quite often done. The available-energy concept associated with the Second Law of Thermodynamics goes back to Maxwell (1) and Gibbs (2) and has had many names such as available-work, energie-utilisable, exergy, essergy, potential energy, a v a i l a b i l i t y . . . (The authors feel that the lack of a uniformly adopted appropriate nomenclature has been a significant factor in the resistance to widespread use of the available energy concepts.) It is ironical that, although the concept arose in English-speaking countries, and even though a few American thermodynamicists have been emphasizing its importance for some time, only in the last several years has available energy started to receive serious interest in the U.S., at least at the practical level. It was Keenan (3) who f i r s t emphasized that cost accounting should be based on available energy, not energy. Consequently, Obert and followers (5-13) have made straightforward applications of available-energy costing in some uncomplicated cases of practical importance, while Tribus and followers (14,15,16) have made important theoretical contributions. This paper reviews the use and advantages of using the available-energy concept for costing "energy" commodities. The basic principles which underlie available energy accounting are presented and explained. Also, various uses of such accounting are also described--in particular, applications to (1) cost accounting, ( i i ) design optimization, and ( i i i ) system operation and maintenance. The aim, then, is to provide a good understanding of the principles and the realm of available energy accounting.

O-8412-0541-8/80/47-1224143$05.00/0 © 1980 American Chemical Society Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

144

THERMODYNAMICS: SECOND LAW ANALYSIS

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

Available Energy Available energy is the thermodynamic property which measures the potential of a system to do work when restricted by the inevit­ able surroundings at TQ and PQ and yj Q . . . Unlike energy, a v a i l a b i l i t y is not conserved, and any degradation, such as f r i c ­ tion or heat transfers through a temperature difference, or chemi­ cal conversions through chemical potential differences, results in destruction of a v a i l a b i l i t y . The destruction of a v a i l a b i l i t y is often called i r r e v e r s i b i l i t y and is a lost a b i l i t y to do work, heat, convert chemicals, etc. Derivation of the basic a v a i l a b i l i t y equa­ tions is straightforward (see for example (3) through (7)) and will not be repeated here. The significant results, for considera­ tions in this paper, are embodied in the steady-flow a v a i l a b i l i t y balance applicable to any steady process, device or system: {Net rate of a v a i l a b i l i t y supply to a process} = {Net rate of a v a i l a b i l i t y output from the process} +

{Net rate of a v a i l a b i l i t y loss in effluents}

+

{Net rate of a v a i l a b i l i t y consumption by the process}

Or, ΣΡ

Α

-ι · = ΣΡ 4 4 + ΣΡ + A . A,supplies A,outputs A,effluents consumed Α

A

(1)

r f 1

In this symposium volume, Petit and Gaggioli (17) present equations which relate the transports, P , to various commodities with which a v a i l a b i l i t y is commonly carried, and Rodriguez and Petit (18) present means for evaluating the P4 from thermodynamic property data. Comparing equation (1) to the steady-flow energy equation (equation (2)) i l l u s t r a t e s the significant difference between the two properties energy and a v a i l a b i l i t y : A

ΣΡ . = ΣΡ„ 4 4 + ΣΡ ~«. E,supplies E,outputs E,effluents Ε

Ε

Ί

v

(2) J

As indicated in equation (2), energy is conserved. But available energy need not be conserved and is, in fact, destroyed (consumed) in every real process, as reflected by the i r r e v e r s i b i l i t y , A in equation (1), which must always be positive. The performance parameter of a v a i l a b i l i t y analysis is the second-law efficiency (The second-law efficiency has been termed effectiveness (_3) ; but, to decrease confusion with the different "effectiveness of heat exchangers, the term second-law efficiency is preferred.), denoted by η 4 , and defined as c

11

η

_ a v a i l a b i l i t y of desired output ΙΙ ~ a v a i l a b i l i t y supplied

For example, in a simple mechanical-compression refrigeration sys­ tem, the refrigeration is the desired product, so the numerator in

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

9.

REisTAD AND GAGGiOLi

Avaihble-Energy

145

Costing

equation (3) becomes the a v a i l a b i l i t y of the refrigeration; the denominator, being the a v a i l a b i l i t y supplied to drive the system, is the power input to the compressor. To compare with the energy analysis, consider the energy or first-law efficiency n4:

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

η

_ energy of desired output Ι ~ energy input

4

The merit of the two performance parameters has been discussed elsewhere (3,_5,8) ; and, for purposes here, let it suffice to recap b r i e f l y the essence of these discussions. The second-law e f f i c ­ iency is the performance parameter which indicates the true thermo­ dynamic performance of the system. It is the n j j , not the nj, which measures how well a device (or system) is performing, compar­ ed to the optimum possible performance. In other words, - j j not 1 - η. is a measure of the potential for improvement. The first-law efficiency is useful only for comparing systems which have like (equal grade) inputs and like (equal grade) outputs, or for comparing two models of a device. 1

n

Available Energy Accounting Available energy accounting in "energy" systems is important in regard to a number of types of engineering-economic decision making. This section presents the rationale and basics of avail­ able-energy cost accounting. It summarizes material from refer­ ences (6) and (8-16), wherein additional examples and details may be found. The types of decision making to be considered here are (i) the proper costing of different energy u t i l i t i e s supplied from a common system, ( i i ) design optimization, and ( i i i ) component operation and maintenance strategies. Costing Energy U t i l i t i e s . In many instances, an industrial concern is engaged in the manufacture of products some of which are steam-intensive, some of which are electricity-intensive, others of which are compressed-air-intensive, and so on. In these cases, it is important for management to debit each product prop­ erly for the cost of the e l e c t r i c i t y , the steam, the compressed-air, etc., used in its manufacture. Similarly, a company which cogenerates may wish to s e l l excess steam or e l e c t r i c i t y to an outside concern: it needs to know the correct costs of these commodities. Also, an electric u t i l i t y may be distributing and selling steam or hot water. In each of these situations, a method must be devised to determine properly the costs of the "energy" flow streams. The following discussion i l l u s t r a t e s that the "energy" flows should not be costed on the basis of their energy content, but that costing them on the basis of their available-energy content does provide a rational method. Money Balances. The f i r s t step in costing "energy" flow streams is the application of money balances to the system of in­ terest. The cost (C) of the product of an energy-converter equals

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

THERMODYNAMICS: SECOND LAW ANALYSIS

146

the total expenditure made to obtain it--the fuel expense, plus the capital and other expenses: C = C =C +C product expended fuel capital, etc. The average unit cost, C p , of the product is the total cost, product °y output power: c Ξ C /P . Similarly, the fuel cost can be expressed as Cf i = C f P f where C fisthe unit cost of fuel and P f j is the power input to the converter. One may then write C

d i v i d e d

t

h

e

prod

ue

d

u e l

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

u e

P

°f fuel

ρ

4capital

~P—Τ

=

r

*

+

prod

λ

prod

Recall that the efficiency is simply Pprod4fuel' c

s o

t h a t

°f 4capital t

η

P

4 prod The f i r s t term on the right reflects fuel costs, and the second the capital (and other) costs. Costing on the Basis of Energy Content: It is common to cost power flows on the basis of energy content. Such costing with energy can lead to radical errors, which lead to misconceptions, poor decisions, and misappropriations. As emphasized by Keenan(3), the proper commodity to be costed is the available energy. The following example, for costing co-generated steam and shaft power, will i l l u s t r a t e these claims. When steam and e l e c t r i c i t y are co-generated, it is often c r i ­ t i c a l to know how much of the costs should be attributed to each commodity. The f i r s t step in determining the unit cost of the turbine shaft work and that of the "back-pressure steam" (the exhaust steam from the turbine) is to obtain the unit cost of the high-pressure steam supplied to the turbine. This cost can be determined by applying the foregoing expression for the unit cost of product, c , to the boiler:

Ρ

c

Q

coal boiler c„„ +' P HP steam = η, . 4 boiler HP steam In turn, the outputs of the turbine, driven by the high-pressure steam, are shaft-work and low-pressure steam. A money balance yields the total cost of these products as Ί

C

C

shaft work P

shaft shaft

+C

+

C

îlrk

LP,steam P

LP LP

=

C

=C

P

HP HP

expended +

C

= c P + C HP HP turbine

turbine

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

9.

REisTAD AND GAGGiOLi

Avaihble-Energy

147

Costing

If the purpose of the steam turbine is to convert power sup­ plied in steam to shaft power, then the shaft power should be debited for the cost of the power extracted from the steam, [P p- P ] , as well as for capital and other costs: H

L p

C

shaft shaft

P

C

LP

=

C

P

P

HP 4 HP " LP4

+

C

turbine

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

while =

C

HP

Dividing the former equation by the shaft power ρ -Ρ r HP LP 4turbine shaft work HP Ρ, . Ρ, _ shaft shaft C

C

+

r4

Considering the co-generating power plant indicated in Figure 1 and Table I, and with the shaft power and steam costed on the basis of their energy content (i.e., the power flows will be measured with energy), the unit cost of the high-pressure steam is (neglecting the relatively low a v a i l a b i l i t y value of the water entering the boiler) 6

= C

HP

($1.60/10 Btu) 0.87

m 0

4

1

0

Btu kWh

6

0.08($10(10 )/yr)(3413 Btu/kWh) (180,000 lbm/hr)(0.7)(8760

hr/yr)(1377.8-18.l)Btu/lbm

= Ο.δΙφ/kWh and, per pound, c Ι Π

t U

c

= (0.8U/kWh) C

H p

3

7

4

1

8

'

1

jfljfo

= 0.32*/lbm .

f 0-08($70/kW)(10300 kW)/yr _ goé/kWh ((10300 kW) (0.7) (8760 hr/yr) " ° - * /

R

- 0 81*/kWh °shaft " ° - * /

+ k w h +

8 1

1

3

9 0

k W n

and C

LP

=

=

°HP

8 1

°- */

k W n

or, on a per pound of steam basis, c

L p

= (Ο.βΙί/kWh)

1 1 8 2 3 4

i3

1 8 , 1

î S = 0.276*/lbm

If such energy-based costing is valid under the above circumstances, with back-pressure steam being delivered at 50 psig, then it should also be appropriate when the back-pressure is 40 psig, or 30, 20, 10, . . . Figure 2, curve A, shows the results of just

American Chemical Society Library 1155 16th St. N. W. Washington, D. C. 20031 Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

THERMODYNAMICS: SECOND LAW ANALYSIS

148 Table I.

Basic Cost and Performance Data of a 10,000 kW, 50 psia Back Pressure Co-generating Power Plant.

Description:

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

Shaft work output Steam from boiler Boiler cost Turbine cost Unit cost of coal η

η

10,300 kW 180000 lbm/hr at 750°F, 650 psia $10(10 ): $5.6(10 )/103 (lbm/hr) $0.7(106): $70/kW $1.60/10 Btu 0.87 6

4

6

Ι,boiler

0.36

ΙΙ,boiler

0.85

η

ΙI,turbine Load factor Amortization factor

0.7 0.08

such costing. The curve indicates that steam at pressures like 0.5 psia (T = 80°F) would be worth about 0.21*/lbm--almost as much as 50 psia steam--even though it has v i r t u a l l y no usefulness for heating. Certainly this is wrong; there would be no buyers of 0.5 psia steam at 0.21*/lbm--at (0.21*/lbm)/((944 - 18.1) Btu/lbm) = $2.26 per million Btu of energy. There is no logical way to decide at which back-pressures energy costing would be appropriate and at which pressures it would not be. Essentially, this shows that the error is in the use of energy as the measure for the power flows. Costing on the Basis of Available Energy: This same procedure will now be followed, but with available energy to evaluate the power flows for the case in which the co-generating power plant exhausts 50 psia steam. For steam produced at 650 psia and super­ heated to 750°F, the available energy per pound is (in this work, T = 510°R, P = 1 atm.) Q

Q

a

f

= h - T s - y Q

Q

= h - T s - ( h 4 T 4 ) = 571 Btu/lbm . Q

Thus, the average unit cost of high pressure steam leaving the boiler is 6

=

HP +

($1.60/10 Btu)(3413 Btu/kWh) 0.36 (0.08($10(106j)/yr)(3413 Btu/kWh) _ ./ (18000 lbm/hr)(0.7)(8760 hr/yr)(561 Btu/lbm) *·»°φ/κ*η

The unit cost of shaft work is then given by

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

g 6

k w h

REisTAD AND GAGGiOLi

Available-Energy

20 •STEAM (75)

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

EFFLUENTS - 3 0 COMBUSTION 100

- 3 0 HEAT

1

s. (15)

TRANSFER

(100)

149

Costing

10

- 5

(10)

Ν

35 (85)

- S H A F T WORK

TURBINE

BOILER Figure 1.

Cogeneration power plant showing available energy and energy flows at one operating condition

PRESSURE, psia

018 ι

50

Q43 095 195 3.72 670 1 1 . 5 190 29.6 458 ι

75

1

1

1

1

1

1

ι

KX) 125 BO 175 200 225 TURBINE EXHAUST TEMPERATURE, F

250

1

I

670

275

E

Figure 2.

Unit steam costs as a function of steam exhaust pressure on the basis of energy and available energy

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

THERMODYNAMICS: SECOND LAW ANALYSIS

150

(0.08($70/kW) (10300kW)/yr) (10300 kW)(0.7)(8760hr/yr)

_

- _

Also, c = CHP = 1.96f/kWh. The available-energy content of the steam is 561 Btu/lbm and 331 Btu/lbm, respectively, for high- and low-pressure steam; and, hence,

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

L p

c

H p

=

(1.96*/kWh)

= 0.32*/lbm

c

L p

=

(1.96*/kWh) C j f f 4 ) =

O.Wt/lb.

Table II compares these available-energy based costs to the energy based costs. Notice the substantial difference in the cost per pound of low-pressure and high-pressure steam when costed on the available-energy basis, in great contrast to the closely equal costs from the energy-based costing. Indeed, the high-pressure (high-temperature) steam is more valuable and would maintain a significantly higher price.

Table II.

Results of Energy Costing and Available-Energy Costing of E l e c t r i c i t y and Steam from a Co-Generating Plant. (Table I l i s t s the basic data for the plant considered here.) Energy Costing

high pressure steam shaft work low pressure (50 psi) steam

0.32f/lbm 0.9*/kWh 0.2764/lbm

Available-Energy Costing 0.32{/lbm 2.44/kWh 0.19{/lbm

The results of repeating this available-energy costing scheme, applied to the co-generation system in which the exhaust pressure is gradually lowered, are shown on Figure 2. Available-energy costing yields that the cost per pound of low-pressure steam does go to zero as its usefulness goes to zero. This is precisely the result that any rational costing scheme should provide. This example has clearly illustrated that energy-based costing can lead to errors and that unit costs should be obtained from available-energy based costing methods. Costing Methods. Consider an energy-converter, for example a boiler, that takes in fuel and produces a single output such as steam. A money balance on the boiler gives C

HP

steam

=

P

°HP HP

=

C

fuel

+

Soiler

Once the fuel cost and boiler costs are known, all that remains is

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

9.

REisTAD AND

Avaifoble-Energy

GAGGiOLi

151

Costing

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

to choose a measure of the product and solve for the unit cost of product. For single-output devices it makes no difference which measure of product output is chosen; it could be mass, energy, available energy, and so on. For example, refer to Table II and note that the unit cost of high-pressure steam is the same for the energy and the available-energy based costing schemes. As in the case of the back-pressure turbine, some energyconverters yield multiple outputs. Recall that the money balance on the turbine of co-generation systems resulted in the expression P

°LP LP

+

C

P

shaft shaft

=

C

P

HP HP

+

C

turbine p

Generally the right-hand side and the power flows, P. and f > are known. This results in one equation with two unknowns : the unit costs c and c h f f Another equation is needed. There are various methods for obtaining a second equation. Which method is appropriate is outside the province of thermodynamics, and depends on economic considerations. The presentation which follows is for co-generation systems that have two or perhaps three outputs (say at two extraction points and shaft output; or steam, compressed-air and shaft power). The economic considerations underlying various methods for obtaining additional cost equations are discussed. The method used in the previous example, called the extraction method, assumes that the sole purpose of the turbine is to produce shaft power. Therefore, the shaft work is charged for the capital cost of the turbine and for the steam available energy used by the turbine to produce the work. With this rationale, the additional equation is obtained by equating the unit costs of high- and lowpressure steam available-energy, c = c . The result is that the shaft work bears the entire burden of the costs associated with the turbine process and capital expense. Insofar as the purpose of a turbine is to produce shaft work, the extraction method is appropriate since it charges the work for the turbine capital and inefficiency. However, i f there were no turbine, the efficiency of producing any required low-pressure steam would be lower and, hence, its unit cost higher. So, when both low-pressure steam and shaft work are required commodities it is appropriate to charge this steam proportionately for the costs attributable to the turbine. The equality method charges the shaft work available-energy and that of the low-pressure steam available-energy equally, for the cost of high pressure steam and turbine capital: c = C g 4 4 . Then, the money balance on the turbine gives p

L p

s

s h a

t

a

L p

H p

L p

C

shaft

=

(c

P

HP HP

+

C

turbine

) / ( P

LP

+

P

shaft

)

Sometimes an industrial concern may view the shaft-work as a by-product-- say because it produces vast amounts of required steam

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

THERMODYNAMICS: SECOND LAW ANALYSIS

152

and/or for historical reasons. The by-product work method assumes that the steam delivered by the turbine would have to be produced anyhow (say to meet process requirements), even i f no power were produced. The available-energy in steam is, therefore, costed as i f it, alone, were produced--in a hypothetical low-pressure boiler which would deliver steam at the pressure and temperature at which it is needed: P

C

°fuel fuel C

+

Ρ

TP

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

*LP

LP boiler _

C

°fuel

" η

P

*LP

LP boiler Ρ

n

II,LP boiler

LP

The low-pressure boiler has a lower efficiency, n j j , than does a high-pressure boiler; and, as a result, the cost c of low-pressure steam available-energy will be greater than for high-pressure steam. Once this c is known, the money balance on the turbine can be solved for Cg4aff This method results in unit cost values for the low-pressure steam that are substantially higher than the equality or extraction methods. Conversely, the cost of shaft work will be lower. An example of an instance when it would be proper to use the by-product method for costing shaft work would be the follow­ ing. Suppose a concern has determined that it will be adding sub­ stantial steam generation capacity. It is considering the prospects of cogenerating power for its own use. Then, i f the prospective cost of the power, determined by the by-product method, proves to be less than the cost of purchased power, the concern ought to cogenerate. Once the decision to co-generate is made, then it is another matter--a different economic problem--to determine how the steam and power should be costed in order to charge the "consumers" within the concern properly. For examples, the extraction or equality method might be appropriate. Similarly, there are instances in which the steam should be considered as a by-product. The by-product steam method charges the shaft work on the basis of the cost to produce shaft work from a condensing turbine or on the cost of purchased shaft work (really e l e c t r i c i t y plus the cost of a motor), whichever is cheaper: L p

L p

c

=

shaft

c

shaft, condensing

or c

shaft

= c

shaft, purchased

The cost of low-pressure steam, c4p, can then be obtained from the turbine money balance. This scheme will yield a low unit cost of steam and a high unit cost of shaft work. The choice of a costing method depends upon the object of economic study and/or upon the circumstances under which it is being made. Up to this point the methods discussed involve only average unit costs of flow streams. A different problem is one in which, for example, an economic study has the purpose of ascertaining the

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

9.

REisTAD AND CACCiOLi

Available-Energy

Costing

153

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

desirability of increasing (or decreasing) the manufacture of some product, which results in additional power requirements. The incremental method--which charges the additional units of power required for the cost of producing them—is then appropriate. The use of the average cost of producing all of the units would be inappropriate (except in the special, though not infrequent, cases when incremental costs are close to average costs). Another instance when incremental costs are appropriate is in the case of design optimization. Design Optimization. The goal in design optimization of energy conversion systems as considered here is to select the equipment which strikes the best balance between overall capital (and other) costs and the cost of the a v a i l a b i l i t y input for the particular type of system operating under the given constraints. That is, the aim is to minimize the total expenditure for capital and fuels. The rationale of the use of available energy in such optimization is that it allows a large complex system to be optimized by parts, s p l i t t i n g the overall system into much less complex subsystems (perhaps unit operations and/or individual components thereof) and optimizing these individually, rather than optimizing the whole system at once. In such situations, much insight can be applied because of dealing with the much simpler subsystems, leading to easier optimization. The use of available energy in optimization of a complex energy system is quite similar to its use in costing of energy flows as presented above, inasmuch as the keys are (i) the use of money balances, and ( i i ) the assignment of unit costs to available energy. On this basis, a cost or value of the available energy flows at the various junctures within the system can be determined (iteratively). Then i f , for example, a particular component needs to deliver some specified output, knowing the unit cost of the a v a i l a b i l i t y supplied to the component, the component and its operating conditions can be selected (or designed) so that the total costs--of a v a i l a b i l i t y supplied thereto and of capital costs thereof, (etc.)--can be minimized. Typical parameters (decision variables) of a component which can be adjusted in order to attain the optimum system are efficiency, operating pressure and temperature, speed, and so on and so forth. Evans, Tribus and co-workers (14,15,16) have treated this subject under the t i t l e of Thermoeconomics. They express each explicit variable of the overall system money balance as a function of the design parameters—those variables which could be a r b i t r a r i l y selected by the designer in order to obtain a workable design, but which ought to be rationally selected in order to obtain an optimal design. Applying the usual calculus methods, they determine the conditions which would minimize the total expenditure. It is shown that, as long as a system operates at steady (or quasi-steady) conditions, it is possible to separate a complex "energy" intensive system into subsystems which, when individually optimized by

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

THERMODYNAMICS: SECOND LAW ANALYSIS

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

154

balancing costs of available energy dissipation against amortized capital costs, will optimize the overall system. As mentioned above, the key is that the proper value be assigned to the available energy at the various subsystem junctures. The work of Evans, et a l . , shows in general that these proper values are incremental costs, arising as adjoint Lagrange multipliers of the respective available energy streams. As expected, the values at junctures within the system are generally higher than the cost of available energy in the primary fuel inputs to the system. Consider an example of Evans, et a l . , which consists of three subsystems in an overall system, as shown in Figure 3a (14). Fig­ ure 3b shows the system with the subsystems separated and ready for economic optimization with the X s representing unit available energy values at the points indicated. To do this rigorously, the capital costs and input available energy rate of each subsystem must be expressed as functions of the output available energy rate and the decision variables {X} particular to that subsystem. Let us consider only two special cases among those considered by Evans, et a l . (14). For the case in which the subsystem capital costs are insensitive to the output available energy rate and each subsystem cost depends only on the thermodynamic efficiency n j j , then the result of the mathematical optimization is that = c4, !

λ

C

l = ΰ /η -, and λ_ = = . These are the expected 2 ι ii.i 3 n n n results since, i f changing the output doesn't change the capital cost, the only incremental cost for increasing the output of a sub­ system is the increase in " f u e l " (i.e., available energy input) cost, and this latter cost is proportional to the unit cost of the "fuel" and inversely proportional to the efficiency of " f u e l " u t i l i ­ zation. Consider the situation where the subsystem capital costs increase linearly with output available energy, λ

0

Ί

2

τ τ

H ) 2

C

n > 1

I I > 2

= a. + b.P. , l l l+l

i

and are functions of the variables η , [i.e., a = 4 C n j j 4 ) , b = g ( n j j 4 ) ] . Ι Τ

i

λ

1

=

i

i

1

, and njj Then the costs'are 2

3

C

l l = b. + — π,ι C

λ 2

1

η

and C

λ

= b„ +

2

. II,2 Notice that these costs also turn out as expected; the incremental cost is that associated with increased capital expenditure, pro­ portional to output in the case at hand, plus that associated with 3

2

n

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

Figure 3.

λ, Ρ, 4Pg 2

λ Ρ 2

Β

2

C2

* 8

λϊΡ 3

le,

*



χ

4

3

c

out

out

p

c

out P out

Journal of Engineering for Power

3

c3

« 3

System with three subsystems illustrating their separation (14)

I

c,

«ι

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

-

85

ι—·



Ο

ι

S

«*.

ο

ο

CO

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

156

THERMODYNAMICS: SECOND LAW ANALYSIS

increased " f u e l " costs as before. Observe that, i f a- = 0 and b.4 is constant, then = £±/Ρ±+ι, and these costs are the same as the average costs used in the costing of energy u t i l i t i e s discussed. Many times the average costs adequately approximate the incremental costs., especially for devices in which the second-law efficiency is relatively constant. The restriction of the foregoing methods to steady systems can also be relaxed when the subsystem efficiencies change l i t t l e with system load. This second special case, with capital costs continuously proportional to subsystem output, is a reasonable approximation to the cost of equipment and installation for the usual subsystem. Therefore, it can be a quite useful assumption, especially for the f i r s t iterations of the design optimization. However, the usual subsystem cannot be purchased in continuously varying sizes but only in step-wise varying sizes with corresponding step-wise vary­ ing prices. Nevertheless, continuously varying subsystem outputs can be achieved by varying the operating parameters of a subsystem.) Therefore, the assumed proportionality can only be an approximation to the step-wise varying cost. The results of the optimization will then indicate which size of subsystem to i n s t a l l . Once the size is decided, then the optimization can be carried further, to determine the optimal operating conditions for this size of sub­ system in the system at hand; this further optimization would f o l ­ low the former special case, with capital costs independent of sub­ system output. It should be mentioned that other methods of design optimiza­ tion, employing the Second Law for costing, have been used. For example, without e x p l i c i t l y determining the cost of available energy at each juncture of a system, in 1949 Benedict (see 19) employed the Second Law for optimal design. He determined the "work penalties" associated with the i r r e v e r s i b i l i t i e s in an a i r separa­ tion plant. That is, the additional input of shaft power to the compressors required as a consequence of i r r e v e r s i b i l i t i e s was determined from the entropy production in each subsystem. Assoc­ iated with additional shaft power requirements are the costs of the power i t s e l f and the increased capital for larger compressors. Each subsystem could then be optimally selected on the basis of the tradeoff between increased capital expenditure for reducing sub­ system i r r e v e r s i b i l i t i e s on the one hand, and increased power and compressor costs on the other hand. Obert and Gaggioli (6) applied Second Law costing to the opti­ mal design of steam piping and its insulation in a power plant. In essence, they costed the consumption and loss of the steam's available energy in terms of the lost output of power. More recently Wepfer, Gaggioli and Obert (13) presented the methodology for economic design of piping and insûTation on the basis of available energy costs determined by the methods described earlier in the present a r t i c l e . The application of Second Law methods to design is in its infancy. However, it is clear from the few simple cases where it has been used for these purposes, and for decision-making in system

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

9.

REisTAD AND

GAGGiOLi

Available-Energy

Costing

157

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

maintenance and operation, that further development of available energy accounting for optimization is important. This development can best be achieved by tackling additional practical applications, beginning with the more manageable ones and proceeding to the more d i f f i c u l t ones as individual and collective experience is gained. Maintenance and Operation Decisions. The determination of an appropriate cost of available energy at various junctures of a system in a manner similar to that described above for Design Optimization is useful not only in design but also allows decisions regarding the repair or replacement of a specific subsystem to be readily made (£,410). The amortized cost of such improvements can be easily compared with the cost of the additional available energy that will be dissipated i f a component is l e f t to operate in the given condition. The proper decision then becomes very apparent. The cost of available energy that should be used in these maintenance applications is determined in a manner very similar to those described in the foregoing section. However, the exact procedure of treating capital costs depends on the nature of the overall system. If the system is to produce at a constant output and is presently able to do that, then the deteriorated condition of a specific component is merely resulting in extra usage of fuel available energy. In this situation, the sunk capital costs do not influence the unit a v a i l a b i l i t y costs at each juncture, and capital costs should be disregarded. For a series system, the unit availa b i l i t y costs would then start at the base fuel-available-energy cost and merely be increased by a factor equal to 1/nji i at each component i . If, on the other hand, an increased market is available for output from the system, then the unit available energy prices should be set by beginning with the output a v a i l a b i l i t y , setting its (incremental) unit cost equal to the market price. Then, proceeding backwards through the system, the unit cost of the input to subsystem i is njj 4 times that of the output therefrom. Conclusions It has not been the intent of this paper to give a thorough treatment of the theory of available energy accounting. Rather, the aim has been to introduce the subject simply, presenting the relationships and methods for applying such costing in simple applications and describing the various practical uses of Second-Law costing. If further elaboration on the fundamentals is desired, the reader may refer to (12,14) for examples. Neither has it been our purpose to present the specifics of one (or more) sample applications. For examples of applications in detail, see (4,1J0,14,13419) and the papers by Wepfer, Benedict and Gyftopoulos, and Petit in this volume. Thus, it is hoped that this paper and the companion paper by Wepfer will encourage and f a c i l i t a t e the practical use of availableenergy accounting by enhancing the understanding of the basic concepts.

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

THERMODYNAMICS: SECOND LAW ANALYSIS

158

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

In summary, available-energy costing can greatly f a c i l i t a t e (i) cost accounting of "energy" commodities, and ( i i ) the economics of alternative choices in design and operation of a system and/or its components. Often the same results can be achieved without recourse to available energy, but only through more d i f f i c u l t , indirect procedures.

Nomenclature Symbol AC

- a v a i l a b i l i t y destruction

AQ

-

a v a i l a b i l i t y of heat transfer (positive into the system)

A4

-

a v a i l a b i l i t y of work transfer (positive into the system)

a4

-

a v a i l a b i l i t y per unit flowing mass (flow availability)

C c EQ E e4

-

annual cost rate ($/year for example) unit cost energy of heat transfer energy of work transfer energy per unit flowing mass

h nu Ρ ρ Ρφ

-

enthalpy per unit mass mass flow power, typically kWh/year pressure dead state pressure

s Τ TQ

-

entropy per unit mass temperature dead state temperature

W

V W X λ Uj

o

(irreversibility)

- volume of system - work transfer - decision variables of a subsystem - unit cost of available energy as Lagrange multiplier - dead state chemical potential of constituent j

Hj

-

f i r s t law efficiency

rijj

-

second law efficiency

Subscript e - exit i - inlet 0 - dead state condition Overline - per unit time

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.

9.

REISTAD AND

GAGGIOLI

Available-Energy

Costing

159

Literature Cited 1. 2. 3.

Downloaded by CALIFORNIA INST OF TECHNOLOGY on December 9, 2017 | http://pubs.acs.org Publication Date: May 28, 1980 | doi: 10.1021/bk-1980-0122.ch009

4. 5. 6. 7. 8, 9. 10.

11.

12.

13.

14.

15.

16. 17. 18. 19.

20.

Maxwell, J. C.,"Theory of Heat," Longmans Green, London, 1871 (also see later editions). Gibbs, J. W., 1875; see "Collected Works," vol. 1, p. 77, Yale U. Press, 1948. Keenan, J., "A Steam Chart for Second Law Analysis," Trans. A.S.M.E., 1932, 54, (195). Keenan, J. Η., "Thermodynamics," John Wiley and Sons, Inc., New York, 1941. Obert, E. F., "Thermodynamics," McGraw-Hill, New York, 1948. Obert, E. F. and Gaggioli, R. Α., "Thermodynamics," McGraw-Hill, New York, 1963 (Second Edition). Gaggioli, R. Α., "The Concept of Available Energy," Chem. Engr. Sci., 1961, 16, (87). Reistad, G. Μ., "Availability: Concepts and Applications," PhD Thesis, University of Wisconsin, 1970. Fehring, T. and Gaggioli, R., "Economics of Feedwater Heater Replacement," Trans. A.S.M.E., J. Eng. Power, 1977, 99. Gaggioli, R. and Fehring, T., "Economics of Boiler Feed Pump Drive Alternatives," Combustion, 1978, 49, (9). Also ASME Paper No. 77/JPGC-PWR-8. Gaggioli, R. Α., "Proper Evaluation and Pricing of Energy," Proc. Int. Conf. on Energy Use Management, 1977, II, Pergamon Press. Gaggioli, R. Α., and Wepfer, W. J., "Available Energy Account­ ing - A Cogeneration Case Study." Presented at the Α.I.Ch.Ε. Annual Meeting, June 1978. Gaggioli, R., and Wepfer, W., "Economic Sizing of Piping and Insulation," to be presented at ASME Winter Annual Meeting, San Francisco, Dec. 11-14, 1978. Evans, R. and El-Sayed, Y., "Thermoeconomics and the Design of Heat Systems," Trans. A.S.M.E., J. Eng. Power, 1970, 92, 27-35. Tribus, M., Evans, R., and C r e l l i n , G., "Thermoeconomics," Ch. 3 of "Principles of Desalinatio," edited by K. Spiegler, Academic Press, 1966. Tribus, M., and Evans, R., "Thermo-economics," UCLA Report No. 52-63, 1962. Petit, P., and Gaggioli, R., "Second Law Procedures for Evalu­ ating Processes," this volume. Rodriguez (S.J.), L., and Petit, P., "Calculation of AvailableEnergy Quantities," this volume. Gyftopoulos, E., Widmer, T., and Lazaridis, L., "Potential Fuel Effectiveness in Industry," Bollinger Publishing Co., Cambridge, MA, 1974. Wepfer, W., "Applications of Availability Accounting," this volume.

RECEIVED October 30, 1979.

Gaggioli; Thermodynamics: Second Law Analysis ACS Symposium Series; American Chemical Society: Washington, DC, 1980.